Altinex TNP121C, TNP131, TNP121, TNP122, TNP151C User Manual

...
Page 1
TABLETOP SOLUTIONS
TNP121
Front View
TNP151
Front View
TNP151 / 151
C
MANUAL PART NUMBER: 400-0434-005
TNP121 / 121C
TNP122 / 131 / 142
TILT ‘N PLUG®JR.
INTERCONNECT BOXES
Page 2
INTRODUCTION
We greatly appreciate your purchase of the Tilt ‘N Plug Jr. (TNP JR.) Interconnect Box. We are sure you will find it reliable and simple to use.
Superior performance for the right price, backed by solid technical and customer support is what ALTINEX has to offer.
The product you are holding is designed using state-of-the-art technology and is superior to anything available on the market. You will find this and our other products reliable, long-lasting, and simple to operate.
We are committed to providing our customers with Signal Management Solutions demanding audiovisual installations at very competitive pricing.
We appreciate your selection of our products and are confident that you will join the ranks of our many satisfied customers throughout the world.
®
to the most
TABLETOP SOLUTIONS
TABLE OF CONTENTS
Page
PRECAUTIONS / SAFETY WARNINGS...............2
GENERAL .........................................................2
INSTALLATION PRECAUTIONS.......................2
CLEANING ........................................................2
FCC NOTICE.....................................................2
ABOUT YOUR TILT 'N PLUG JR...........................3
TECHNICAL SPECIFICATIONS ............................3
TILT 'N PLUG JR. DIMENSIONS...........................5
DIAGRAM 1: ROUND BEZEL DIMENSIONS.....5
DIAGRAM 2: SINGLE UNIT DIMENSIONS........6
DIAGRAM 3: DUAL UNIT DIMENSIONS...........6
DESCRIPTION DIAGRAM...................................... 7
DIAGRAM 4: STANDARD FACEPLATES .........7
MOUNTING DIAGRAM............................................8
DIAGRAM 5: MOUNTING A TNP JR.................8
INSTALLATION PROCEDURES............................9
TROUBLESHOOTING GUIDE............................... 9
ALTINEX POLICIES..............................................10
LIMITED W ARRANTY/RETURN POLICIES ....10
CONTACT INFORMATION ..............................10
400-0434-005 1
Page 3
TABLETOP SOLUTIONS

PRECAUTIONS / SAFETY WARNINGS 1

Please read this manual carefully before using your Tilt ‘N Plug Jr. Interconnect Box. Keep this manual handy for future reference. These safety instructions are to ensure the long life of your Tilt ‘N Plug Jr. and to prevent fire and shock hazards. Please read them carefully and heed all warnings.

1.1 GENERAL

Unauthorized personnel shall not open the unit as there are high-voltage components inside.
Qualified ALTINEX service personnel or their authorized representatives must perform all service.

1.2 INSTALLATION PRECAUTIONS

For best results, place the Tilt ‘N Plug Jr. in a dry area away from dust.
To prevent fire or shock, do not expose this unit to water or moisture. Do not place the unit in direct sunlight, near heaters or heat-radiating appliances, or near any liquid. Exposure to direct sunlight, smoke, or steam can harm internal components.
Handle the Tilt ‘N Plug Jr. carefully. Dropping or jarring can damage the bezel.
Never place fingers inside the opening on either side of the unit. This action could cause injury due to sharp edges inside.
Do not place heavy objects on top of the Tilt ‘N Plug Jr. Do not use excessive force to push down on the top of the unit.
Disconnect the power cord to turn off the power. This supplies power to the socket on the pop -up panel. The power outlet should be installed near the equipment and be easily accessible.
We recommend using wall outlets with a Ground Fault Circuit Interrupter (GFCI) for maximum protection.
Install all cables according to the instructions found herein. Do not force or pull any cable that is attached to the Tilt ‘N Plug Jr.

1.3 CLEANING

Surfaces should be cleaned with a dry cloth. Never use strong detergents or solvents such as alcohol or thinner. Do not use a wet cloth or water to clean the unit.

1.4 FCC NOTICE

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions found herein, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his expense.
Any changes or modifications to the unit not expressly approved by ALTINEX, Inc. could void the user’s authority to operate the equipment.
400-0434-005 2
Page 4
TABLETOP SOLUTIONS
*
Customizable on the TNP121C

ABOUT YOUR Tilt 'N Plug Jr. 2

TILT ‘N PLUG JR.
Designer Interconnect Solutions
All Tilt ‘N Plug Jr.’s belong to a family of compact interconnection solutions designed for installation into a table as part of a presentation system. They are designed for mounting into a table, podium, or other furniture to provide a way of connecting audiovisual equipment on top of the furniture to a presentation system below the furniture.
All use the same core element; a multimedia input plate that can be "tilted" open when needed and pushed closed when not needed.
The TNP122 and TNP142 each incorporate two Tilt ‘N Plug Jr. modules and are operated independently. The TNP142 is the same as a TNP122, but with the modules factory-installed facing in opposite directions. The TNP131 is the same as a TNP121, but with a round bezel instead of a square bezel.
All signals pass through the input plate directly to cables on the underside of the table with no intervening circuitry. The use of additional ALTINEX Signal Management Solutions®such as computer video interfaces, distribution amplifiers, and switchers may be desirable.
The input plate of the Tilt ‘N Plug Jr. is accessible by pushing down on the top cover. The unit then auto-tilts open with help from an internal pneumatic spring. Once open, the input plate remains securely in place. The input plate is hidden by pressing down on the top cover until the latching mechanism engages. In its closed position, the top panel lies flush with the tabletop, held in place by the latching mechanism.
All Tilt ‘N Plug Jr. Signal Management Solutions come with a standard top and bezel offering a high quality matte black finish. Other finishes or special bezel configurations are available upon request. Please contact an ALTINEX representative to discuss custom options.

TECHNICAL SPECIFICATIONS 3

Specifications are subject to change. See www.altinex.com for up-to-date information.
FEATURES/ DESCRIPTION
PASS-THROUGH AC Power
110 VAC, 60 Hz, 5 A NEMA F-M
Audio, Video, and Communication *
Computer Video 15-pin HD F-M (1) Stereo Audio 3.5 mm F-M (1) Network RJ-45 F-M (1) Modem RJ-11 F-M (1)
Accessories Included
Hardware
Table 1. TNP121/121C/131 General
FEATURES/ DESCRIPTION
PASS-THROUGH AC Power
110 VAC, 60 Hz, 5 A
Audio, Video, and Communication
Computer Video 15-pin HD F-M (2) Computer Audio 3.5mm F-M (2) Network CAT-6 (RJ-45) F-M (2) Modem RJ-11 F-M (2)
Accessories Included
Hardware
Table 2. TNP122/142 General
TNP121/121C/131
10 ft (3 m)
6 ft (2 m)
- Mounting screws and brackets
- Cable clamps/screws
TNP122/142
10 ft (3 m)
NEMA F-M
(2 female to 1 male)
6 ft (2 m)
- Mounting screws and brackets
- Cable clamps/screws
400-0434-005 3
Page 5
TABLETOP SOLUTIONS
*
Customizable on the TNP1
5
1C
FEATURES/ DESCRIPTION
PASS-THROUGH AC Power 10 ft (3 m)
110 VAC, 60 Hz, 5 A
Audio, Video, and Communication *
Network CAT-6 (RJ-45) F-M (2)
Accessories Included
- Mounting screws and
Hardware
- Cable clamps/screws
TNP151/151C
NEMA F-M
(2 female to 1 male)
6 ft (2 m)
brackets
Table 3. TNP151/151C General
MECHANICAL
Max. Table Thickness 2.3 in (58 mm) Height, opened 5.5 in (140 mm)
Width........(TNP121/151)
Diameter...(TNP131)
Depth........(TNP121/151)
TNP121/121C/
131/151/151C
4.6 in (117 mm)
5.8 in (147 mm)
4.9 in (124 mm)
MECHANICAL TNP122/1 42
Max. Table Thickness 2.3 in (58 mm) Height, opened 5.5 in (140 mm) Width 8.7 in (221 mm) Depth 4.9 in (124 mm) Finish Matte Black Weight (approx.) 3.7 lb (1.7 kg) Shipping Weight 5.4 lb (2.5 kg) T° Operating 10°C-35°C T° Maximum Humidity
90% non-condensing
40°C
Table 5. TNP122/142 Mechanical
ELECTRICAL (Single outlet panel)
Power Rating
(pass-through AC power)
TNP121/121C/
122/131/142
110VAC, 60Hz,
5A per connector
Weight (approx.) 2.8 lb (1.3 kg) Shipping Weight 4.5 lb (2.0 kg) Finish Matte Black T° Operating (T° Max) 10°C-35°C (40°C) Humidity
90% non-condensing
Table 4. TNP121/121C/131/151/151C Mechanical
400-0434-005 4
Table 6. TNP121/121C/122/131/142 Electrical
ELECTRICAL (Dual outlet panel)
Power Rating
(pass-through AC power)
TNP151 and
TNP151C
110VAC, 60Hz,
2.5A per connector
Table 7. TNP151/151C Electrical
Page 6
TABLETOP SOLUTIONS

Tilt 'N Plug Jr. DIMENSIONS 4

NOTE: Detailed dimensions, tabletop cutout templates, and drawings are available on the
ALTINEX website at www.altinex.com

DIAGRAM 1: ROUND BEZEL DIMENSIONS

5.75"
[146mm]
TNP131
Dimensions
1.97"
[50mm]
3.53"
[90mm]
400-0434-005 5
5.50"
[140mm]
Page 7

DIAGRAM 2: SINGLE UNIT DIMENSIONS

4.60"
[117mm]
4.90"
[124.5mm]
1.97''
[50mm]
3.53''
[90mm]
TABLETOP SOLUTIONS
TNP121, TNP121C,
TNP151, TNP151C
Dimensions
5.50''
[140mm]

DIAGRAM 3: DUAL UNIT DIMENSIONS

8.70''
[221mm]
4.90''
[124.5mm]
1.97''
[50mm]
3.53''
[90mm]
400-0434-005 6
TNP122, TNP142
Dimensions
5.50''
[140mm]
Page 8

DESCRIPTION DIAGRAM 5

DIAGRAM 4: STANDARD FACEPLATES

TNP121
TABLETOP SOLUTIONS
15-pin HD VGA
RJ-11 Phone Jack
Power
110VAC, 2.5A
3.5mm Audio Jack
Power 110VAC, 5A
CAT-6 (RJ-45) Network Jack
TNP151
Power 110VAC, 2.5A
400-0434-005 7
CAT-6 (RJ-45) Network Jack ( 2 )
Page 9

MOUNTING DIAGRAM 6

DIAGRAM 5: MOUNTING A TNP JR.

TABLETOP SOLUTIONS
Tabletop
Support
Bracket
Table
Securing
Screw
Support Bracket
Table
Securing
Screw
400-0434-005 8
Page 10
TABLETOP SOLUTIONS

INSTALLATION PROCEDURES 7

Step 1. Cut an opening into the table’s surface.
Refer to the ALTINEX website at
www.altinex.com for table cutout
requirements. Note: The table can be 2.25” or less in
thickness. Always confirm dimensions before cutting to insure that specifications have not changed.
Step 2. Insert the Tilt ‘N Plug Jr. into the table
cutout.
Step 3. Place the support brackets under the
table in between the support mount grooves on the side of the Tilt ‘N Plug Jr. (See Diagram 5 for details.) Attach the brackets to the groove at the desired height and secure them to the bottom of the table using the thumb screws provided.
Step 4. Secure the cables by using the provided
cable clamps and screws included with the unit. Pass the power cord from the bottom of the housing and attach it to the table using the cable clamp and screw supplied with the Tilt ‘N Plug Jr.

TROUBLESHOOTING GUIDE 8

The Tilt ‘N Plug Jr. supplied was carefully tested and no problems were detected. However, we would like to offer the following suggestions:
Please make sure that the highest quality network cables are used.
Make sure that no cable or power cord is damaged or pinched. If there has been damage, do not use the Tilt ‘N Plug Jr. Please call the ALTINEX Customer Service Department at (714) 990-2300 to have the unit repaired.
If the unit does not rise into position correctly, check the service loops for the signal and power cords on the bottom of the unit.
Leave enough slack in the service loop to allow for easy opening and closing, but not too much as to cause excess drooping of the service loop.
Step 5. Connect the appropriate cables with the
correct input connectors on the bottom of the unit.
Step 6. Once you have applied power and
connected the proper cables on the bottom of the unit you may raise the unit. To raise the Tilt ‘N Plug Jr. into position, push down on the front of the top cover; the latching mechanism will then release, allowing the pneumatic spring to raise it into position.
Step 7. To lower the unit, push on the top of the
Tilt ‘N Plug Jr. until it locks into place.
400-0434-005 9
Page 11

ALTINEX POLICIES 9

9.1 LIMITED WARRANTY/RETURN POLICIES

Please see the ALTINEX website at
www.altinex.com for details on warranty and
return policies.

9.2 CONTACT INFORMATION ALTINEX, Inc.

592 Apollo Street Brea, CA 92821 USA
TEL: 714 990-2300 TOLL FREE: 1-800-ALTINEX WEB: www.altinex.com E-MAIL: solutions@altinex.com
TABLETOP SOLUTIONS
400-0434-005 10
Loading...