MANUAL PART NUMBER: 400-0118-001
PRODUCT REVISION: 1
TNP100UNUN
Tilt ‘N Plug™ UNIVERSAL
Interconnect Box
USER'S GUIDE
Page 2
ACCESSORIES
INTRODUCTION
Your purchase of the TNP100UN Tilt ‘N Plug™
Interconnect Box is greatly appreciated. We are sure
you will find it reliable and simple to use.
Superior performance for the right price, backed by
solid technical and customer support is what
ALTINEX has to offer.
The product you are holding in your hands is
designed using state-of-the-art technology and is
superior to anything available on the market. You will
find this and our other products reliable, long lasting,
and simple to operate.
We are committed to providing our customers with
signal management solutions to the most demanding
audio-visual installations at very competitive pricing.
We appreciate your selection of our products and are
confident that you will join the ranks of our many
satisfied customers throughout the world.
This manual covers:
TNP100UN – Tilt ‘N Plug™ Interconnect Box.
TABLE OF CONTENTS
Page
PRECAUTIONS / SAFETY WARNINGS............... 2
GENERAL ......................................................... 2
CONTACT INFORMATION ............................. 12
1
Page 3
ACCESSORIES
PRECAUTIONS / SAFETY WARNINGS1
Please read this manual carefully before using your
TNP100UN Interconnect Box. Keep this manual
handy for future reference. These safety instructions
are to ensure the long life of your TNP100UN and to
prevent fire and shock hazard. Please read them
carefully and heed all warnings.
1.1 GENERAL
• Unauthorized personnel shall not open the
unit since there are high-voltage
components inside.
• Qualified ALTINEX service personnel, or
their authorized representatives must
perform all service.
• Do not place heavy objects on top of the
TNP100UN. Do not use excessive force to
push down on the top of the unit.
• To turn off the main power, disconnect the
power cord, which powers the power socket
on the TNP100UN pop up panel. The power
outlet socket should be installed as near to
the equipment as possible, and should be
easily accessible.
• We recommend using wall outlets with a
Ground Fault Circuit Interrupter (GFCI) for
maximum protection.
• Install all cables according to the
instructions. Do not force or pull out any
cable or power cord that is attached to the
TNP100UN Interconnect Box.
1.3 CLEANING
• Surfaces should be cleaned with a dry cloth.
Never use strong detergents or solvents,
such as alcohol or thinner. Do not use a wet
cloth or water to clean the unit.
1.2 INSTALLATION
• For best results, place the TNP100UN
Interconnect Box in a dry area away from
dust and moisture.
• To prevent fire or shock, do not expose this
unit to rain or moisture. Do not place the
TNP100UN Interconnect Box in direct
sunlight, near heaters or heat radiating
appliances, or near any liquid. Exposure to
direct sunlight, smoke, or steam can harm
internal components.
• Handle the TNP100UN Interconnect Box
carefully. Dropping or jarring can damage
internal components.
• Never place fingers inside the opening on
each side of the unit. This action could
cause serious injury because of the sharp
edges inside of the TNP100UN.
1.4 FCC / CE NOTICE
• This device complies with part 15 of the
FCC Rules. Operation is subject to the
following two conditions: (1) This device
may not cause harmful interference, and (2)
this device must accept any interference
received, including interference that may
cause undesired operation.
• This equipment has been tested and found
to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide
reasonable protection against harmful
interference when the equipment is
operated in a commercial environment. This
equipment generates, uses, and can radiate
radio frequency energy and, if not installed
and used in accordance with the instruction
manual, may cause harmful interference to
radio communications. Operation of this
equipment in a residential area is likely to
cause harmful interference in which case
2
Page 4
ACCESSORIES
the user will be required to correct the
interference at his own expense.
• Any changes or modifications to the unit not
expressly approved by ALTINEX, Inc. could
void the user’s authority to operate the
equipment.
ABOUT YOUR TNP100UN2
The TNP100UN is designed for installation into a
conference room table. The Tilt ‘N Plug™Interconnect Box (TNP100UN) provides a means of
connecting audio, video, control, and computer video
sources into a presentation system. It is ideal for use
together with ALTINEX computer video interfaces.
The Tilt ‘N Plug™ Interconnect Box can either pop up
and “tilt” to a raised position to provide access to the
connectors or it can be lowered into a table when not
in use. A pneumatic shock inside the TNP100UN’s
tower type construction applies pressure to the panel
mechanism, making it easy to raise and secure the
unit firmly in an open position. Also, for safety, the
chassis of the TNP100UN is connected to the ground
pin of the power plug.
The Tilt ‘N Plug™ Interconnect Box provides easy
access to system inputs when they are needed. It
also removes system inputs when not needed,
eliminating the obstruction. The Tilt ‘N Plug™Interconnect Box has one input plate on the front
panel of the unit. The standard plate offers Computer
Video (15-pin HD); Composite Video (RCA), Audio
(RCA), Computer Audio (Stereo Mini), Modem (RJ-
11), 9-pin D-type RS-232 and Network (RJ-45) input
connections. All signals are passed through to a set
of female connectors or cables. Several optional
connectors can be substituted for the standard set of
connectors.
TECHNICAL SPECIFICATIONS3
FEATURES/
DESCRIPTION
GENERAL
Front Panel
Standard
Configuration
Connectors
The Tilt ‘N Plug™ Interconnect Box is designed for
use with tables ranging from one to three inches
thick. It offers an optional mounting bezel to secure
the unit flush with the table’s surface. The Tilt ‘NPlug™ comes in a standard matte black color. The
top of the unit can be finished to match the table or it
can be painted another color. This is available on a
custom per order basis at an additional charge.
PowerTNP100UN
Power Rating (pass
through connector)
220-240V~5A,
Table 3. TNP100UN Electrical
3
50/60Hz
Page 5
TNP100UN DIMENSIONS4
Diagrams: 1A, 1B, 1C, & 1D
ACCESSORIES
4
Page 6
DESCRIPTION DIAGRAM5
Diagram 2: Label of Product
ACCESSORIES
APPLICATION DIAGRAM6
5
Page 7
Diagram 3: Application
ACCESSORIES
6
Page 8
Diagram 4: Final Installation
ACCESSORIES
7
Page 9
Diagram 5: Table Cutout Requirements
ACCESSORIES
8
Page 10
ACCESSORIES
INSTALLATION6
Step 1. Cut an opening into the table’s surface.
Refer to diagram 5 on page 8 of the
manual for table cutout requirements.
Note: The table can be 3 inches or thinner
in thickness. Always confirm dimensions
before cutting to insure that specifications
have not changed.
Step 2. Insert the TNP100UN into the opening in
the table.
Step 3. Place the support brackets under the table
and place them between the support
mount grooves on the side of the
TNP100UN unit. Attach the brackets to the
groove at the desired height and secure
them to the bottom of the table using the 632 nut. There are two support brackets,
one for each side of the unit. (See Figure
1)
Step5.Connect the appropriate cables with the
correct input connectors. There are two
RCA audio connectors on the front panel
of the TNP100UN. The black connector is
known as audio left, whereas the red
connector is called audio right. There is
also an RCA video connector, which is
yellow in color. The network connection is
red. In addition, the telephone or data
connection is gray.
Step 6. Once you have applied power and
connected the proper cables on the bottom
of the unit, you may raise the unit. To raise
the TNP100UN into position, lift the top by
pulling upward at the notch in the top plate.
Step 7. To lower the unit, push on the top of the
TNP100UN until it fits into place.
For more information, please refer to the FAQ
Section or the Troubleshooting Guide.
Figure 1: Attachment of the TNP100UN to a
table using support brackets and set screws
Step 4. Secure the cables by using the provided
cable clamp (See Figure 2). Pass the
power cord from the bottom of the housing
and attach it to the table using the cable
clamp supplied with the TNP100UN unit.
Do not keep the cord too tight or too loose
(See Diagram 4, page 7).
Figure 2: Cable Clamp
9
Page 11
ACCESSORIES
OPERATION7
7.1 HOW TO RELEASE AND REPLACE THE GAS
SPRING
To replace the spring, push up, and turn the
knob in the center on the bottom of the
TNP100UN by 90 degrees, thereby releasing
the gas spring.
Unscrew the knob, and then unscrew the gas
spring itself from the TNP100UN. Replace the
gas spring with a new one by screwing it in,
and then replacing the knob.
Re-engage the new gas spring by pushing
up, and turning the knob by 90 degrees. After
you have finished this step, you have
completed the installation.
Under normal conditions the gas spring will
last up to five years.
FREQUENTLY ASKED QUESTIONS (FAQ)8
No:QuestionAnswer
1Why are the
VGA connectors
female on both
ends of the
cables?
2Why is there a
DB-9 connector?
3What happens if
the spring
breaks?
4What do I do if
the TNP100UN
won’t stay open?
5How much room
is taken up on
the underside of
the table?
6What if my table
is thicker than 3
inches?
7Are cables
available for
connecting a
PC/laptop to the
TNP100UN
available?
8Does ALTINEX
honor any
warranty on field
modifications?
Female cables are more
reliable.
The DB-9 connector is
compatible with RS-232
serial communication.
The unit will not stay
open.
Replace the gas spring.
Call ALTINEX for service
information.
The unit is 4.5 inches
deep maximum below
the table; to this
dimension add about 2.5
inches for cable
clearance.
Then the area under the
table near the
TNP100UN must be
reduced to 3 inches of
thickness.
Consider using
MS8126CA (3ft) or
MS8156CA (6ft) for VGA
connection.
Anything modified by
non-ALTINEX personnel
is not covered by
warranty.
CABLES AND ACCESSORIES9
10
Page 12
ACCESSORIES
Model No.Description
VGA MALE TO MALE (HD-15)
HIGH RESOLUTION CABLE
CB37xxMR
CB39xxHR
CB5000PL5VMxxx5VM
CB5000PL5VMxxxx5VF
CB5100PL5VMxxxx5VM
CB5100PL5VMxxxx5VF
xx = available length of 3ft, 6ft,
15ft, 25ft, öö50ft, öö75ft, öö100ft,
& öö150ft
VGA MALE TO FEMALE (HD-
15) HIGH RESOLUTION
CABLE
xx = available length of 3ft, 6ft,
15ft, 25ft, öö50ft, öö75ft, öö100ft,
& öö150ft
SUPER HIGH RESOLUTION
PLENUM-FLEX MULTICHANNEL COAX CABLE
VGA MALE TO VGA MALE
(HD-15)
xxx = available length of 3ft,
6ft, 15ft, 25ft, 50ft, 75ft, 100ft,
150ft, 200ft, & 250ft
SUPER HIGH RESOLUTION
PLENUM-FLEX MULTICHANNEL COAX CABLE
VGA MALE TO VGA FEMALE
(HD-15)
xxx = available length of 3ft,
6ft, 15ft, 25ft, 50ft, 75ft, 100ft,
150ft, 200ft, & 250ft
SUPER HIGH RESOLUTION
PLENUM-FLEX MULTICHANNEL COAX CABLE
VGA MALE TO VGA MALE
(HD-15)
xxx = available length of 3ft,
6ft, 15ft, 25ft, 50ft, 75ft, 100ft,
150ft, 200ft, & 250ft
SUPER HIGH RESOLUTION
PLENUM-FLEX MULTICHANNEL COAX CABLE
VGA MALE TO VGA FEMALE
(HD-15)
xxx = available length of 3ft,
6ft, 15ft, 25ft, 50ft, 75ft, 100ft,
150ft, 200ft, & 250ft
OPTIONAL CUSTOM
CONNECTORS
Blank Connector (Snap-in and
15-pin location)
BNC Female
4-pin Mini-DIN
6-pin Mini-DIN
ööIndicates super high resolution cable type
11
Page 13
ACCESSORIES
TROUBLESHOOTING GUIDE10
The TNP100UN supplied unit was carefully tested
and no problems were detected; however, we
would like to offer the following suggestions:
• If there is no power, check to see if any of the
two 5A circuit breakers are tripped. If only one
circuit breaker is tripped, power may be present
at one of the connector pins.
• Please make sure that the highest quality
video, audio, network, and telephone cables or
connectors are used.
• Make sure that no cable or power cord is
damaged or pinched. If there has been
damage, then do not use the TNP100UN unit.
Immediately contact the ALTINEX Customer
Service Department to have the unit repaired.
ALTINEX POLICY11
11.1 LIMITED WARRANTY
ALTINEX warrants that its products and cables
are free from defects in materials under normal
use and service. This warranty is limited to
repairing at company’s factory any part or parts
of the product, which upon company’s
examination shall disclose to be, thus defective.
Products considered defective should be returned
to company with transportation charges pre-paid
within 2 years (90 days for cables) from date of
shipment to the purchaser. The warranty is
expressly instead of all other warranties
expressed or implied. ALTINEX neither assumes
nor authorizes any other person to assume for it
any other liability concerning the sale of the
products. This warranty shall not apply to any
product that shall have been repaired or altered
outside of company’s factory in any way so as, in
its judgment, to affect its stability or reliability, or
that has been subject to misuse, negligence, or
accident.
It is very important to ALTINEX that you receive
all products that you have ordered and that this
product meets your expectations. In the unlikely
event that an ALTINEX product needs to be
returned, please follow the policies below:
Altinex will accept all product returns for a period
of 30 days from authorized ALTINEX dealers in
an unopened package.
If a product has been opened, the restocking
fees will apply. For the restocking fee, please
contact an ALTINEX Sales Representative.
If the product is in your possession for more than
30 days, the restocking fees will apply.
Altinex will not accept any returns on cables or
custom products.
If your product is in warranty and needs service,
contact the ALTINEX Sales Department for an
RMA (Return Material Authorization). Products
returned without an RMA number may
experience a delay in service.
If your product is out of warranty and needs
service, contact the ALTINEX Sales Department
for an RMA (Return Material Authorization).
Products returned without an RMA number may
experience a delay in service. The service
charges will be quoted to you before the actual
repairs are done.
11.3 CONTACT INFORMATION
Phone: 714-990-2300
Fax: 714-990-3303
11.2 RETURN POLICY
12
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.