ACCESSORIES
MANUAL PART NUMBER: 400-0117-001 PRODUCT REVISION: 1
TNP100UKUN
Tilt ‘N Plug™ Interconnect Box
FOR THE UNITED KINGDOM
USER'S GUIDE
Page 2
Page
PRECAUTIONS / SAFETY WARNINGS...............2
GENERAL..........................................................2
INSTALLATION .................................................2
CLEANING ........................................................2
FCC / CE NOTICE.............................................2
ABOUT YOUR TNP100UK ...................................3
TECHNICAL SPECIFICATIONS...........................3
TNP100UK DIMENSIONS ....................................4
DIAGRAMS 1A-1D.............................................4
DESCRIPTION DIAGRAM....................................5
DIAGRAM 2.......................................................5
APPLICATION DIAGRAM.....................................6
DIAGRAM 3.......................................................6
DIAGRAM 4.......................................................7
DIAGRAM 5.......................................................8
INSTALLATION.....................................................9
OPERATION.......................................................10
FREQUENTLY ASKED QUESTIONS.................10
CABLES AND ACCESSORIES...........................11
TROUBLESHOOTING GUIDE............................12
ALTINEX POLICY...............................................12
LIMITED WARRANTY.....................................12
RETURN POLICY............................................12
CONTACT INFORMATION..............................12
ACCESSORIES
1
Page 3
ACCESSORIES
PRECAUTIONS / SAFETY WARNINGS 1
Please read this manual carefully before using your TNP100UK Interconnect Box. Keep this manual handy for future reference. These safety instructions are to ensure the long life of your TNP100UK and to prevent fire and shock hazard. Please read them carefully and heed all warnings.
1.1 GENERAL
Unauthorized personnel shall not open the unit since there are high-voltage components inside.
Qualified ALTINEX service personnel, or their authorized representatives must perform all service.
Do not place heavy objects on top of the TNP100UK. Do not use excessive force to push down on the top of the unit.
To turn off the main power, disconnect the power cord, which powers the power socket on the TNP100UK pop up panel only. The power outlet socket should be installed as near to the equipment as possible, and should be easily accessible.
We recommend using wall outlets with a Ground Fault Circuit Interrupter (GFCI) for maximum protection.
Install all cables according to the instructions. Do not force or pull out any cable or power cord that is attached to the
TNP100UK Interconnect Box.
1.3 CLEANING
Surfaces should be cleaned with a dry cloth. Never use strong detergents or solvents, such as alcohol or thinner. Do not use a wet cloth or water to clean the unit.
1.2 INSTALLATION
For best results, place the TNP100UK Interconnect Box in a dry area away from dust and moisture.
To prevent fire or shock, do not expose this unit to rain or moisture. Do not place the TNP100UK Interconnect Box in direct sunlight, near heaters or heat radiating appliances, or near any liquid. Exposure to direct sunlight, smoke, or steam can harm internal components.
Handle the TNP100UK Interconnect Box carefully. Dropping or jarring can damage internal components.
Never place fingers inside the opening on each side of the unit. This action could cause serious injury because of the sharp edges inside of the TNP100UK.
1.4 FCC / CE NOTICE
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case
2
Page 4
ACCESSORIES
the user will be required to correct the interference at his own expense.
Any changes or modifications to the unit not expressly approved by ALTINEX, Inc. could void the user’s authority to operate the equipment.
ABOUT YOUR TNP100UK 2
The TNP100UK is designed for installation into a conference room table. The Tilt ‘N Plug™ Interconnect Box (TNP100UK) provides a means of connecting audio, video, control, and computer video sources into a presentation system. It is ideal for use together with ALTINEX computer video interfaces. The Tilt ‘N Plug™ Interconnect Box can either pop up and “tilt” to a raised position to provide access to the connectors or it can be lowered into a table when not in use. A pneumatic shock inside the TNP100UK’s tower type construction applies pressure to the panel mechanism, making it easy to raise and secure the unit firmly in an open position.
The Tilt ‘N Plug™ Interconnect Box has one input plate on the front panel of the unit. The standard plate offers Computer Video (15-pin HD); Composite Video (RCA), Audio (RCA), Computer Audio (Stereo Mini), 9-pin D-type RS-232 and Network (RJ-45) input connections. All signals are passed through to a set of female connectors or cables. For additional information regarding optional connectors, contact the ALTINEX Sales Department.
The Tilt ‘N Plug™ Interconnect Box is designed for use with tables ranging from one to three inches thick. It offers an optional mounting bezel to secure the unit flush with the table’s surface. The Tilt ‘N Plug™ comes in a standard matte black color. The top of the unit can be finished to match the table or it can be painted another color. This is available on a custom per order basis at an additional charge.
TECHNICAL SPECIFICATIONS 3
FEATURES/
DESCRIPTION GENERAL Front Panel
Standard Configuration Connectors
Power
Computer Video 1 15-pin HD-F 1 15-pin HD-F Composite Video Audio, left, right 1 Black, 1 Red
Audio 1 3.5 mm stereo Network 1 RJ-45 F (8­Control 1 DB-9 F 1 DB-9 F
Faceplate
1 receptacle
1 U.K. outlet with a 5 A circuit
1 Yellow RCA F 1 Yellow RCA F
RCA F
position)
Table 1. TNP100UK General
MECHANICAL TNP100UK
Width (inches) 6.05in (154mm) Height (closed) 4.79in (122mm) Height (opened) 8.05in (205mm) Depth (inches) 7.56in (192mm) Finish Flat Black T° Operating 10°C-35°C T° Maximum 50°C Humidity
Table 2. TNP100UK Mechanical
ELECTRICAL TNP100UK Power
Power Rating (pass through connector)
Table 3. TNP100UK Electrical
TNP100UK
F
Cable end
under table
1 plug with 6ft
cord
breaker
1 Black, 1 Red
RCA F
3-position terminal block 1 RJ-45 M (8-
position)
90% non-condensing
220-240V~5A,
50/60Hz
3
Page 5
TNP100UK DIMENSIONS 4
Diagrams: 1A, 1B, 1C, & 1D
ACCESSORIES
4
Page 6
DESCRIPTION DIAGRAM 5
Diagram 2: Label of Product
ACCESSORIES
5
Page 7
APPLICATION DIAGRAM 6
Diagram 3: Application
ACCESSORIES
6
Page 8
Diagram 4: Final Installation
ACCESSORIES
7
Page 9
Diagram 5: Table Cutout Requirements
ACCESSORIES
8
Page 10
ACCESSORIES
INSTALLATION 6
Step 1. Cut an opening into the table’s surface.
Refer to diagram 5 on page 8 of the manual for table cutout requirements. Note: The table can be 3 inches or thinner in thickness. Always confirm dimensions before cutting to ensure that specifications have not changed.
Step 2. Insert the TNP100UK into the opening in
the table.
Step 3. Place the support brackets under the table
and place them between the support mount grooves on the side of the TNP100UK unit. Attach the brackets to the groove at the desired height and secure them to the bottom of the table using the 6­32 screw. There are two support brackets, one for each side of the unit. (See Figure
1)
Step 5.Connect the appropriate cables with the
correct input connectors. There are two RCA audio connectors on the front panel of the TNP100UK. The black connector is known as audio left, whereas the red connector is called audio right. There is also an RCA video connector, which is yellow in color. In addition, the network connection is red.
Step 6. Once you have applied power and
connected the proper cables on the bottom of the unit, you may raise the unit. To raise the TNP100UK into position, lift the top by pulling upward at the notch in the top plate.
Step 7. To lower the unit, push on the top of the
TNP100UK until it fits into place.
For more information, please refer to the FAQ Section or the Troubleshooting Guide.
Figure 1: Attachment of the TNP100UK
to a table using support brackets and set screws
Step 4. Secure the cables by using the provided
cable clamp (See Figure 2). Pass the power cord from the bottom of the housing and attach it to the table using the cable clamp supplied with the TNP100UK unit. Do not keep the cord too tight or too loose (See Diagram 4, page 7).
Figure 2: Cable Clamp
9
Page 11
ACCESSORIES
OPERATION 7
The TNP100UK will operate successfully as long as all cables are attached properly and other technical specifications are followed.
FREQUENTLY ASKED QUESTIONS (FAQ) 8
No: Question Answer 1 Why are the
VGA connectors female on both ends of the cables?
2 Why is there a
DB-9 connector?
3 What happens if
the spring breaks?
4 What do I do if
the TNP100UK won’t stay open?
5 How much room
is taken up on the underside of the table?
6 What if my table
is thicker than 3 inches?
7 Are cables
available for connecting a PC/laptop to the
TNP100UK
available?
8 Does ALTINEX
honor any warranty on field modifications?
Female cables are more reliable.
The DB-9 connector is compatible with RS-232 serial communication. The unit will not stay open.
Replace the gas spring. Call ALTINEX for service information. The unit is 4.5 inches deep maximum below the table; to this dimension add about 2.5 inches for cable clearance. Then the area under the table near the TNP100UK must be reduced to 3 inches of thickness. Consider using MS8126CA (3ft) or MS8156CA (6ft) for VGA connection.
Anything modified by non-ALTINEX personnel is not covered by warranty.
10
Page 12
ACCESSORIES
CABLES AND ACCESSORIES 9
Model No. Description
VGA MALE TO MALE (HD-15) HIGH RESOLUTION CABLE
CB37xxMR
CB39xxHR
CB5000PL­5VMxxx5VM
CB5000PL­5VMxxxx5VF
xx = available length of 3ft, 6ft, 15ft, 25ft, öö50ft, öö75ft, öö100ft, & öö150ft
VGA MALE TO FEMALE (HD-
15) HIGH RESOLUTION CABLE
xx = available length of 3ft, 6ft, 15ft, 25ft, öö50ft, öö75ft, öö100ft, & öö150ft
SUPER HIGH RESOLUTION PLENUM-FLEX MULTI­CHANNEL COAX CABLE VGA MALE TO VGA MALE (HD-15)
xxx = available length of 3ft, 6ft, 15ft, 25ft, 50ft, 75ft, 100ft, 150ft, 200ft, & 250ft
SUPER HIGH RESOLUTION PLENUM-FLEX MULTI­CHANNEL COAX CABLE VGA MALE TO VGA FEMALE (HD-15)
xxx = available length of 3ft, 6ft, 15ft, 25ft, 50ft, 75ft, 100ft, 150ft, 200ft, & 250ft
TROUBLESHOOTING GUIDE 10
The TNP100UK supplied unit was carefully tested and no problems were detected; however, we would like to offer the following suggestions:
If there is no power, check to see if the circuit breaker is tripped.
Please make sure that the highest quality video, audio, and network cables or connectors are used.
Make sure that no cable or power cord is damaged or pinched. If there has been damage, then do not use the TNP100UK unit. Immediately contact the ALTINEX Customer Service Department to have the unit repaired.
ööIndicates super high resolution cable type
11
Page 13
ACCESSORIES
ALTINEX POLICY 11
11.1 LIMITED WARRANTY
ALTINEX warrants that its products and cables are free from defects in materials under normal use and service. This warranty is limited to repairing at company’s factory any part or parts of the product, which upon company’s examination shall disclose to be, thus defective. Products considered defective should be returned to company with transportation charges pre-paid within 2 years (90 days for cables) from date of shipment to the purchaser. The warranty is expressly instead of all other warranties expressed or implied. ALTINEX neither assumes nor authorizes any other person to assume for it any other liability concerning the sale of the products. This warranty shall not apply to any product that shall have been repaired or altered outside of company’s factory in any way so as, in its judgment, to affect its stability or reliability, or that has been subject to misuse, negligence, or accident.
If your product is out of warranty and needs service, contact the ALTINEX Sales Department for an RMA (Return Material Authorization). Products returned without an RMA number may experience a delay in service. The service charges will be quoted to you before the actual repairs are done.
11.3 CONTACT INFORMATION ALTINEX, Inc.
Phone: 714-990-2300 Fax: 714-990-3303
11.2 RETURN POLICY
It is very important to ALTINEX that you receive all products that you have ordered and that this product meets your expectations. In the unlikely event that an ALTINEX product needs to be returned, please follow the policies below:
ALTINEX will accept all product returns for a period of 30 days from authorized ALTINEX dealers in an unopened package.
If a product has been opened, the restocking fees will apply. For the restocking fee, please contact an ALTINEX Sales Representative.
If the product is in your possession for more than 30 days, the restocking fees will apply.
ALTINEX will not accept any returns on cables or custom products.
If your product is in warranty and needs service, contact the ALTINEX Sales Department for an RMA (Return Material Authorization). Products returned without an RMA number may experience a delay in service.
12