Altinex PNP547, PNP527C, PNP515, PNP547C, PNP527 User Manual

...
Page 1
TABLETOP SOLUTIONS
003
PNP537C
, PNP547, PNP547C
PNP515
PNP517
MANUAL PART NUMBER: 400-0464-
PNP515, PNP517,
PNP527, PNP527C, PNP537,
®
CUSTOMIZABLE POP 'N PLUG
WITH CUSTOM TABLETOP SURFACE
Page 2
TABLETOP SOLUTIONS
TABLE OF CONTENTS
Page
PRECAUTIONS / SAFETY WARNINGS................ 2
GENERAL..........................................................2
INSTALLATION PRECAUTIONS.......................2
CLEANING.........................................................2
FCC NOTICE.....................................................2
ABOUT YOUR PNP515/517 ....................................3
TECHNICAL SPECIFICATIONS.............................. 3
PRODUCT DESCRIPTION ...................................... 4
APPLICATION DIAGRAMS...................................... 5
DIAGRAM1: TYPICAL SETUP ..........................5
DIAGRAM2: CUTOUT DIMENSIONS................6
DIAGRAM3: CLOSED DIMENSIONS................6
DIAGRAM4: FRONT VIEW DIMENSIONS.........7
DIAGRAM5: SIDE VIEW DIMENSIONS.............8
DIAGRAM6: STANDARD PLATES US & UK .....9
DIAGRAM7: STANDARD PLATES AU & GR...10
INSTALLING YOUR PNP515................................. 11
OPERATION.............................................................11
OPENING AND CLOSING THE PNP515..........11
POWER/SIGNAL CONNECTIONS...................11
TROUBLESHOOTING GUIDE...............................11
ALTINEX POLICIES ................................................ 11
LIMITEDWARRANTY/RETURNPOLICIES.....11
CONTACT INFORMATION ..............................11
This manual also covers the following:
PNP527 and PNP527C for UK, PNP537 and PNP537C for Australia, PNP547 and PNP547C for Germany
PNP527 and PNP527C for UK
PNP527: PNP515 with 2 x DS901-122 PNP527C: PNP515 with 2 x DS901-125
PNP537 and PNP537C for Australia
PNP537: PNP515 with 2 x DS901-123 PNP537C: PNP515 with 2 x DS901-126
PNP547 and PNP547C for Germany
PNP547: PNP515 with 2 x DS901-124 PNP547C: PNP515 with 2 x DS901-127
400-0464-003 1
Page 3
TABLETOP SOLUTIONS

PRECAUTIONS / SAFETY WARNINGS 1

Please read this manual carefully before using your PNP515/517 Interconnect Box. Keep this manual handy for future reference. These safety instructions are to ensure the long life of your PNP515/517 and to prevent fire and shock hazards. Please read them carefully and heed all warnings.

1.1 GENERAL

Unauthorized personnel shall not open the unit
since there are high-voltage components inside.
Qualified ALTINEX service personnel, or their
authorized representatives, must perform all service.
To turn off the main power, disconnect the power cord which powers the AC socket on the PNP515/517 pop-up panel. The power outlet used should be installed as near to the equipment as possible and should be easily accessible.
ALTINEX recommends using wall outlets with a Ground Fault Circuit Interrupter (GFCI) for maximum protection.
Install all cables according to the instructions. Do not force or pull out any cable or power cord that is attached to the PNP515/517.

1.3 CLEANING

Surfaces should be cleaned with a dry cloth. Never use strong detergents or solvents such as alcohol or thinner. Do not use a wet cloth or water to clean the unit.

1.4 FCC NOTICE

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

1.2 INSTALLATION PRECAUTIONS

For best results, place the PNP515/517 in a dry area away from dust and moisture.
To prevent fire or shock, do not expose this unit to water or moisture. Do not place the PNP515/517 in direct sunlight, near heaters or heat-radiating appliances, or near any liquid. Exposure to direct sunlight, smoke, or steam can harm internal components.
Handle the PNP515/517 carefully. Dropping or jarring can damage the unit.
Never place fingers inside the openings of the unit. This action could cause serious injury due to sharp edges inside the PNP515/517.
Do not place heavy objects on top of the PNP515/517. Do not use excessive force to push down on the top of the unit.
400-0464-003 2
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions found herein, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his expense.
Any changes or modifications to the unit not expressly approved by ALTINEX, Inc. could void the user’s authority to operate the equipment.
Page 4
TABLETOP SOLUTIONS

ABOUT YOUR PNP515/517 2

PNP515/517
Pop ‘N Plug with Custom Tabletop Surface
Customizable to almost any table top
Several standard international configurations
Smooth new look on all sides
Cutout always matches table surface
Simple, slide-in installation
Opens/closes by pressing on top
Gas spring lift mechanism
This Pop ‘N Plug uses a custom tabletop cutout surface, and hardware is attached underneath the cutout. When closed, the PNP515/517 lays flat and matches the grain on your table.
The PNP515/517 design allows the connector panels to be easily installed. Just remove the top and slide the connector panels into place. In the open position, the PNP515/517 is functional yet maintains a smooth, clean appearance. A simple press on the lid closes the unit flush with the tabletop.
The PNP515 can be purchased with preconfigured options available that include two standard sectional plates.* Each plate includes one or more of the following: AC power, computer video, stereo audio, modem, or network connections. The AC power receptacles on the face plates are available with US or international connections.
All connectors on the face plates are female receptacles. Each signal connector is connected via a 6-foot cable to its corresponding male plug at the opposite end. The AC power cables are 9-foot cords terminated with standard NEMA plugs for the US version, or with the applicable plug for international versions.

TECHNICAL SPECIFICATIONS 3

Specifications are subject to change. See www.altinex.com for up-to-date information.
FEATURES/ DESCRIPTION
Inputs (female) / Outputs (male)
AC Power NEMA 5-15 (8) Video 15-pin HD (4) Computer Audio 3.5mm (4) Network RJ-45 (4) Modem RJ-11 (4) C-Video RCA (2)
Compatibility PNP515
DS901-122 for UK, Accepts DS901 STANDARD sectional plates. *
Accepts DS901 CONFIGURABLE sectional plates. *
Table 1. PNP515 General
MECHANICAL PNP515/517
Min. Table Thickness 0.750 in (19 mm) Max. Table Thickness 1.125 in (29 mm) Max. weight of custom top 22 oz (0.624 kg) Width 5.65 in (144 mm) Depth 5.45 in (138 mm) Height, opened 5.10 in (130 mm) Height (below tabletop) 8.75 in (222 mm) Width (below tabletop) 8.50 in (216 mm)
DS901-123 for Australia,
DS901-124 for Germany,
DS901-128 blank,
DS901-130 for US
DS901-125 for UK,
DS901-126 for Australia,
DS901-127 for Germany,
DS901-131 for US
PNP515/517
PNP517
* See DIAGRAM 6 and DIAGRAM 7 for the available standard plates on both US and international units.
400-0464-003 3
Depth (below tabletop) 6.125 in (156 mm) Finish Matte Black T° Operating 10°C-35°C T° Maximum 40°C Humidity
Table 2. PNP515/517 Mechanical
90% non-condensing
Page 5
ELECTRICAL PNP515/517
TABLETOP SOLUTIONS
Power Rating (pass through AC power)
Table 3. PNP515/517 Electrical

PRODUCT DESCRIPTION 4

120VAC, 60Hz, 5A
Table Surface
RJ-45 (2) RJ-11 (2)
AC Power (4)
Yellow RCA (1)
3.5 mm Stereo (2)
15-PIN HD (2)
Table Surface Table Surface
NOTE: One side of the PNP517 connector installation is shown in the above diagram. The
PNP517 has another of the same sectional plates facing the opposite side of the table. Various combinations of connectors, along with the applicable cable types, may be selected for customization at the time of purchase.
Please, refer to the ALTINEX website (www.altinex.com) for specific customization options and instructions.
400-0464-003 4
Page 6

APPLICATION DIAGRAMS 5

DIAGRAM 1: TYPICAL SETUP

PNP517*
TABLETOP SOLUTIONS
Notebook Computer
Floor box
Notebook Computer
* The PNP517 is shown as in the above diagram. The PNP517 is a standard configuration that includes the
PNP515 and two DS901-301 standard face plates.
400-0464-003 5
Page 7

DIAGRAM 2: CUTOUT DIMENSIONS

TABLETOP SOLUTIONS
5.650"
[144 mm]
5.850"
[149 mm]

DIAGRAM 3: CLOSED DIMENSIONS

5.450"
[138 mm]
5.650"
[144 mm]
3
9
''
4
[248 mm]
3
8
''
4
[222 mm]
400-0464-003 6
Page 8

DIAGRAM 4: FRONT VIEW DIMENSIONS

5 1/10''
[130 mm]
6 1/10''
[155 mm]
TABLETOP SOLUTIONS
TABLE THICKNESS
MIN. 3/4'' MAX. 1 1/8''
[19 mm] [29 mm]
1
6
''
8
[156 mm]
FRONT VIEW
400-0464-003 7
Page 9

DIAGRAM 5: SIDE VIEW DIMENSIONS

7
14
''
8
[378 mm]
TABLETOP SOLUTIONS
SIDE VIEW
3
9
''
4
[248 mm]
1
8
''
2
[216 mm]
400-0464-003 8
Page 10

DIAGRAM 6: STANDARD PLATES US & UK

TABLETOP SOLUTIONS
DS901-130
Standard on PNP517 for United States.
DS901-122
DS901-131
PNP517C with configurable snap-ins.
DS901-125
Standard on PNP527 for United Kingdom.
400-0464-003 9
PNP527C with configurable snap-ins.
Page 11

DIAGRAM 7: STANDARD PLATES AU & GR

TABLETOP SOLUTIONS
DS901-123
Standard on PNP537 for Australia.
DS901-124
DS901-122
PNP537C with configurable snap-ins.
DS901-127
Standard on PNP547 for Germany.
400-0464-003 10
PNP547C with configurable snap-ins.
Page 12
TABLETOP SOLUTIONS

INSTALLING YOUR PNP515 6

Step 1. Refer to the ALTINEX website,
www.altinex.com, to download the latest
templates and instructions for tabletop cutting requirements and installation instructions.
In order to do this, locate the PNP515 on the website and go to its detail page. The links to the templates, user’s guide, and more are on the left-hand side of the screen.
Step 2. Print all information applicable to the
installation of the PNP515, including the templates and any detailed installation instructions.
Step 3. Cut an opening into the table’s surface.
This operation should be performed by experienced professionals in order to insure accuracy and to be aesthetically pleasing.
NOTE: Always confirm dimensions before cutting to insure that specifications have not changed.
Step 4. Install the PNP515 into the table per the
installation instructions provided on the website.
Step 5. Connect all cables to their appropriate
sources and/or destinations. The PNP is now ready for operation.

7.2 POWER/SIGNAL CONNECTIONS

Connect external devices to the appropriate connector on the PNP. Remember, the devices plugged into the AC power connectors should not draw more than 5A AC.

TROUBLESHOOTING GUIDE 8

The PNP unit supplied was carefully tested and no problems were detected. However, we would like to offer the following suggestions:
Please make sure that the highest quality network cables are used.
Make sure that no cable or power cord is damaged or pinched. If there has been damage to the unit, do not use the PNP. Please contact ALTINEX at (714) 990-2300 to have the unit repaired.

ALTINEX POLICIES 9

9.1 LIMITED WARRANTY/RETURN POLICIES

Please see the ALTINEX website at
www.altinex.com for details on warranty and
return policies.

9.2 CONTACT INFORMATION

ALTINEX, Inc.
592 Apollo Street Brea, CA 92821 USA
TEL: 714 990-2300

OPERATION 7

7.1 OPENING AND CLOSING THE PNP515

The PNP will open easily when the top is pressed down and then released.
When the PNP is not in use, simply press the top down until it is level with the surface of the table and then release. The unit will remain hidden until needed again.
400-0464-003 11
TOLL FREE: 1-800-ALTINEX WEB: www.altinex.com E-MAIL: solutions@altinex.com
Loading...