Altinex PNP402 User's Guide

DESIGNER SOLUTIONS
MANUAL PART NUMBER: 400-0109-005
PNP400
POP 'N PLUG TOWER
USER'S GUIDE
TABLE OF CONTENTS
Page
PRECAUTIONS / SAFETY WARNINGS .............. 3
ABOUT YOUR PNP400....................................... 4
TECHNICAL SPECIFICATIONS.......................... 4
PNP400 DIMENSIONS........................................ 5
APPLICATION DIAGRAMS .................................6
INSTALLATION ................................................... 8
OPERATION........................................................ 9
DESIGNER SOLUTIONS
DESIGNER SOLUTIONS
PRECAUTIONS / SAFETY WARNINGS 1
Please read this manual carefully before using your PNP400 Interconnect Tabletop Solution. Keep this manual handy for future reference. These safety instructions are to ensure the long life of your PNP400 and to prevent fire and shock hazard. Please read them carefully and heed all warnings.
1.1 GENERAL
Unauthorized personnel shall not open the unit since there are high-voltage components inside.
Qualified ALTINEX service personnel, or their authorized representatives must perform all service.
1.2 INSTALLATION
For best results, place the PNP400 Interconnect Box in a dry area away from dust and moisture, indoors only.
To prevent fire or shock, do not expose this unit to rain or moisture. Do not place the PNP400 Interconnect Tabletop Solution in direct sunlight, near heaters or heat radiating appliances, or near any liquid. Exposure to direct sunlight, smoke, or steam can harm internal components.
Handle the PNP400 Interconnect Tabletop Solution carefully. Dropping or jarring can damage internal components.
Be careful. Serious injury could result because of the sharp edges inside of the PNP400.
Do not place heavy objects on top of the PNP400. Do not use excessive force to push down on the top of the unit.
To turn off main power, disconnect the power cord, which powers the power socket on the PNP400 outlets.
We recommend using wall outlets with a Ground Fault Circuit Interrupter (GFCI) for maximum protection.
Install all cables according to the instructions. Do not force or pull out any cable or power
cord that is attached to the PNP400 Interconnect Tabletop Solution.
1.3 CLEANING
Surfaces should be cleaned with a dry cloth. Never use strong detergents or solvents, such as alcohol or thinner. Do not use a wet cloth or water to clean the unit.
DESIGNER SOLUTIONS
ABOUT YOUR PNP400 2
The PNP400 is designed for installation into a conference room table. The PNP400 Interconnect Tabletop Solution provides a means of connecting A/V, network and power sources into a presentation system. It is ideal for use together with ALTINEX computer video interfaces, such as VA6804FC. The PNP400 Interconnect Box can “pop up” into a raised position to provide access to connectors or it can be lowered into a table when not in use. The PNP400 uses a tower-type construction with gas spring suspension to accomplish this.
The PNP400 Interconnect Box has two openings on either side of the unit, servicing both sides of a table. Several optional sectional plates with Computer Video (15-pin HD); Composite Video (RCA), Audio (RCA), Computer Audio (Stereo Mini), Modem (RJ-11), 9-pin D-type RS-232 and Network (RJ-45) input connections can be used with the PNP400. For additional information regarding optional connectors, contact the ALTINEX Sales Department.
TECHNICAL SPECIFICATIONS 3
MECHANICAL PNP400 (standard) Mechanical
Base Width (inches) 6.600in (167mm) Height (opened) 8.690in (220mm) Height Above Table 2.956in (75mm)
Height Below Table Base Depth (inches) 4.834in (122mm)
Finish Black T° Operating 10°C-35°C T° Maximum 50°C Humidity
Table 1. PNP400 Mechanical
5.552in (141mm)
(minus table thickness)
90% non-condensing
The PNP400 Interconnect Box is designed for use with tables ranging from one to three inches thick. The PNP400 comes in a standard matte black color. Custom finishes for the top of the PNP400 allow the unit to accent any table top. This is available on a custom per order basis at an additional charge.
PNP400 DIMENSIONS 4
Diagrams: 1A, 1B, 1C, & 1D
DESIGNER SOLUTIONS
APPLICATION DIAGRAMS 5
Diagram 2: Application
DESIGNER SOLUTIONS
Note: Diagram 2 is shown with special connector plates and cables installed. Connectors and cables are not shipped with PNP400, they must be ordered separately. For more information regarding connectors and cables designed for the PNP400, contact the ALTINEX Sales Department at (714) 990-2300 or visit the ALTINEX website at www.altinex.com.
Diagram 3: Table Cutout Requirements
Note: Specifications subject to change without notice. Measurements are NOT to scale. Always confirm
DESIGNER SOLUTIONS
measurements before cutting to insure that specifications have not changed. Always make sure to orient cutout in the direction necessary for proper operation of the installed unit.
DESIGNER SOLUTIONS
INSTALLATION 6
Step 1. The PNP400 ships with a shipping screw.
To remove the shipping screw, push down and turn the spring retaining knob by 90 degrees. Then remove the knob from the PNP400. The spring retaining knob is the smallest silver colored knob that is located in the center on the bottom of the unit.
Re-engage the gas spring by pushing down on the retaining knob and turning it back to the original position, thereby locking the gas spring into place.
Step 2. Cut an opening into the table’s surface
Refer to diagram 3 on page 6 of the manual or the ALTINEX website at
www.altinex.com for table cutout
requirements. Note: The table can be 3 inches or less in thickness. Always confirm dimensions before cutting to ensure that specifications have not changed.
Step 3. Place the table support brackets under
the table and place them between the grooves on the side of the PNP400 unit. Place the brackets at the desired height and secure them to the bottom of the table using a setscrew. There are two support brackets, one for each side of the unit. (See Figure 1)
Step 4. Secure the cables by using a cable clamp.
Pass the power cord from the bottom of the housing and attach it to the table using the cable clamp supplied with the PNP400 unit. Do not keep the cord too tight or too loose. (See Figure 2)
Figure 2: Cable Clamp Installation for Service
Loop (diagram above shows only the power cord not the cables)
Step 5. Connect the appropriate cables with the
correct connectors of the media sources (video, audio, etc.) being used on the sectional plates.
Step 6. Once you have connected power and the
proper cables to the unit, you may raise the unit. To raise the PNP400 into position, press the top of the unit.
Figure 1: Attachment of the PNP400 to the
table using support brackets and set screws
Step 7. To lower the unit, push on the top of the
PNP400 until it fits into place.
For more information, please refer to the FAQ Section or the Troubleshooting Guide.
DESIGNER SOLUTIONS
In Here
OPERATION 7
7.1 HOW TO RELEASE GAS SPRING
In order to remove and install the gas spring, begin with the pop-up unit in the down position.
Apply some pressure in order to compress the gas spring so it will not be ejected with force.
While the gas spring is compressed, remove the side screws from the gas spring support bracket on the bottom of the base unit.
7.3 HOW TO INSTALL GAS SPRING
Screw the replacement spring into the top of the pop-up assembly. Do NOT over tighten. The spring should be finger tightened only.
Attach the spring support bracket to the compression rod portion of the spring.
Carefully compress the new spring while aligning the support bracket mounting holes with those in the base unit.
Fasten the compression rod using 4-40 hardware. Under normal conditions the gas spring will last more than five years.
Shock Screws
PNP400
Bottom
Remove Screw
Figure 3: Spring Support Bracket
7.2 HOW TO REMOVE GAS SPRING
Unscrew the support bracket from the gas spring.
On the bottom of the pop-up assembly, there is a support bracket. This bracket has a clearance hole the spring passes through.
Unscrew the gas spring from the top of the pop-up assembly.
Remove the spring by sliding through the clearance hole in the pop-up assembly support bracket.
Remove Screw
Shock Clearance Hole
Figure 4: Removing the Gas Spring
Top of Shock
DESIGNER SOLUTIONS
7.4 HOW TO INSTALL SECTIONAL PLATES
Install sectional plates in the empty slots on each side of the PNP400 until the plates snap into place. Secure the plates using the plastic reusable rivets as shown in figure 5.
Figure 5: Installing Sectional Plates (Internal view of PNP400)
FREQUENTLY ASKED QUESTIONS (FAQ) 8
No: Question Answer
1.
2.
3.
4.
5.
6.
What happens if the spring breaks? What do I do if the PNP400 won’t stay open? How much room is taken up on the underside of the table?
What if my table is thicker than 3 inches?
Are cables available for connecting a PC/laptop to the
PNP400
available? Does ALTINEX honor any warranty on field modifications?
The unit will not stay open.
Replace the gas spring. Call ALTINEX for service information. The unit is 5.5 inches deep maximum below the table; to this dimension add about 2.5 inches for cable clearance. Then the area under the table near the PNP400 must be reduced to 3 inches of thickness. Consider using MS8126CA (3ft) or MS8156CA (6ft) for VGA connection.
Anything modified by non-ALTINEX personnel is not covered by warranty.
DESIGNER SOLUTIONS
CABLES AND ACCESSORIES 9
Model No. Description
INPUT/OUTPUT LABELS
MS8301LB
CVR1001
SP2107US
SP2201UK SP2301CE
SP2401AU SP3102EP SP3103EP
SP3201AV
SP3202AV
SP3204AV
Cover cutouts for PNP or TNP units
SECTIONAL PLATES
Dual AC Power Outlet for United States & Canada with 2 slots and 12ft metal conduit AC Power Outlet for United Kingdom, Singapore & Hong Kong AC Power Outlet for Continental Europe AC Power Outlet for Australia & New Zealand Dual Empty Snap-in Ports with 1 slot Dual Empty Ortronics CAT-6 Snap-in Ports with 1 slot 15-pin HD-Female to Male + 3.5mm Stereo Female to Male 15-pin HD-Female to Female Gender Changer + 3.5mm Stereo Female to Terminal Block 4-pin Mini DIN + RCA Female 3.5mm Stereo with 1 slot (universal plate for PNP400)
Adhesive label with text
COVER CUTOUTS
TROUBLESHOOTING GUIDE 10
The PNP400 supplied unit was carefully tested and no problems were detected; however, we would like to offer the following suggestions:
Please make sure that the highest quality video, audio, network, and telephone cables or connectors are used.
If there has been damage, then do not use the PNP400 unit. Immediately contact the ALTINEX Sales Department to have the unit repaired.
ALTINEX POLICY 11
11.1 LIMITED WARRANTY / RETURN POLICY
Please see the Altinex website at
www.altinex.com for details on warranty and
return policy.
11.2 CONTACT INFORMATION
ALTINEX, INC
592 Apollo street Brea, CA 92821 USA
TEL: 714 990-2300 TOLL FREE: 1-800-ALTINEX WEB: www.altinex.com E-MAIL: solutions@altinex.com
Loading...