Altinex PNP350, PNP300 User Manual

Page 1
TABLETOP SOLUTIONS
004
The PNP300 is shown above.
MANUAL PART NUMBER: 400-0114-
PNP300 & PNP350
POP ‘N PLUG®SLIM
USER’S GUIDE
Page 2
TABLE OF CONTENTS
Page
PRECAUTIONS / SAFETY WARNINGS................ 2
GENERAL..........................................................2
HANDLING ........................................................2
CLEANING.........................................................2
FCC NOTICE.....................................................2
ABOUT YOUR PNP300/350 ....................................3
TECHNICAL SPECIFICATIONS.............................. 3
PRODUCT DESCRIPTION ...................................... 4
APPLICATION DIAGRAMS ...................................... 5
DIAGRAM1: TYPICAL SETUP ..........................5
DIAGRAM2: DIMENSIONS ............................... 6
DIAGRAM3: MOUNTING ..................................7
DIAGRAM4: CABLE CLAMPS...........................8
INSTALLING YOUR PNP300/350.......................... 9
OPERATION............................................................... 9
OPERATING THE POP-UP PANEL ...................9
TROUBLESHOOTING GUIDE...............................10
ALTINEX POLICIES................................................10
LIMITEDWARRANTY/RETURNPOLICIES.....10
CONTACT INFORMATION ..............................10
TABLETOP SOLUTIONS
400-0114-004
1
Page 3
TABLETOP SOLUTIONS

PRECAUTIONS / SAFETY WARNINGS 1

Please read this manual carefully before using your PNP300/350 and keep it handy for future reference. These safety instructions are to ensure the long life of your PNP300/350 and to prevent fire and shock hazards. Please read them carefully and heed all warnings.

1.1 GENERAL

Do not open the unit or power supply case, there
are high-voltage components inside.
There are no user serviceable parts inside.
Qualified ALTINEX service personnel must perform all service on the Pop ‘N Plug.

1.2 HANDLING

For best results, place the PNP300/350 in a dry
area away from dust and moisture.
To prevent fire or shock, do not expose this unit
to water or moisture. Do not place the PNP300/350 in direct sunlight, near heaters, or heat-radiating appliances, or near any liquid. Exposure to direct sunlight, smoke, or steam can harm internal components.
Handle the PNP300/350 carefully. Dropping or
jarring can damage the unit.
Do not pull any cables that are attached to the
PNP300/350.
Do not place heavy objects on top of the
PNP300/350.
Never place fingers inside the openings of the
unit.
If the PNP300/350 interface is not used for an extended period, disconnect the unit from the wall to avoid fire, shock, and loss of power.
We recommend using wall outlets with a Ground Fault Circuit Interrupter (GFCI) for maximum protection.

1.3 CLEANING

Unplug the PNP300/350 before cleaning.
Clean only with a dry cloth. Never use strong
detergents or solvents such as alcohol or thinner. Do not use a wet cloth or water to clean the unit. Do not open the unit to clean.

1.4 FCC NOTICE

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with instructions found herein, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Any changes or modifications to the unit not expressly approved by ALTINEX, Inc. could void the user’s authority to operate the equipment.
400-0114-004
2
Page 4
TABLETOP SOLUTIONS

ABOUT YOUR PNP300/350 2

PNP300/350
Pop ‘N Plug Slim Interconnect Box
The PNP300/350 is designed for installation in a conference room table, podium, or anywhere computer audio, video, and communications connections are needed. The Pop ‘N Plug Slim provides a means of connecting audio, video, control, and computer video sources into a presentation system. It is ideal for use together with ALTINEX computer video interfaces.
The PNP300/350 Pop ‘N Plug Slim interconnect “pops up” into a raised position to provide access to connectors. When not in use, it is lowered into the tabletop providing a clean, smooth finish. The PNP300/350 uses a tower-type construction with a pneumatic suspension and a mechanical latching mechanism.
The PNP300 has one input plate on the front panel of the unit. The standard plate offers input connections for the following: AC power (NEMA 5-15R), computer video (15-pin HD), composite video (RCA), stereo audio (RCAx2), computer audio (3.5 mm stereo), modem (RJ-11), RS-232 (9-pin D-sub), and network (RJ-45). All signals pass from the interface plate, through standard cables, and terminate in the mating connector for easy connection to the audiovisual system.
The PNP350 Interconnect Box has one input plate on the front panel of the unit. The standard plate offers 2 AC power outlets and 6 RJ-45 network snap-in connectors. All interface connections include pass-through connectors and cables.
The Pop ‘N Plug Slim Interconnect Boxes are designed for use with tabletops ranging from
0.25 in (6 mm) to 3.75 in (95 mm) thick.

TECHNICAL SPECIFICATIONS 3

Specifications are subject to change. See www.altinex.com for up-to-date information.
FEATURES/ DESCRIPTION
PNP300 Connectors
AC (NEMA) 5-15R (1) 5-15P (1) Computer video 15-pin HD F (1) 15-pin HD M (1) Computer audio 3.5 mm F (1) 3.5 mm M (1) Composite video RCA F (1) RCA M (1) Stereo audio RCA F (2) RCA M (2) Modem RJ-11 F (1) RJ-11 M (1) Network RJ-45 F (1) RJ-45 M (1) RS-232 Control DB9 F (1) DB9 M (1)
PNP350 Connectors
AC (NEMA) 5-15R (2) 5-15P (2) Network RJ-45 F (6) RJ-45 M (6)
Table 1. PNP300/350 General
MECHANICAL PNP300/350
Minimum Table Thickness 0.25 in (6 mm) Maximum Table Thickness 3.75 in (95 mm) Length (bezel) 10.03 in (255 mm) Width (bezel) 3.39 in (86 mm) Height (opened, above table) 2.19 in (56 mm) Depth (below table top) 6.14 in (156 mm) Finish Black T° Operating (T° Max) 10°C-40°C (50°C) Humidity
INTERFACE
CONNECTION
90% non-condensing
UNDER TABLE
CONNECTION
400-0114-004
Table 2. PNP300/350 Mechanical
ELECTRICAL PNP300/350 PNP300 90-140 VAC, 5A Max.
PNP350 (each outlet) 90-140 VAC, 5A Max.
Table 3. PNP300/350 Electrical
3
Page 5

PRODUCT DESCRIPTION 4

TABLETOP SOLUTIONS
3.5mm JACK FOR STEREO AUDIO
DB9 F CONNECTOR
FOR COMPUTER PORT
15-PIN HD F CONNECTOR
FOR COMPUTER VIDEO
PNP300
RCA JACK
FOR VIDEO
RCA JACK FOR AUDIO LEFT
RJ-11 JACK FOR PHONE/MODEM
RCA JACK FOR AUDIO RIGHT
RJ-45 JACK FOR NETWORK
NEMA AC POWER OUTLET
R
PNP300
Slim
400-0114-004
NEMA AC POWER
OUTLET
PNP350
RJ-45 JACKS FOR NETWORK (6 PLACES)
NEMA AC POWER OUTLET
R
PNP350
4
Slim
Page 6

APPLICATION DIAGRAMS 5

DIAGRAM 1: TYPICAL SETUP

DVD PLAYER
RS-232 CABLE
VGA CABLE
STEREO AUDIO
CABLE
TABLETOP SOLUTIONS
AUDIO / VIDEO CABLES
STEREO AUDIO TO AUDIO DISTRIBUTOR
PNP300
OR AMPLIFIED SPEAKERS
DB9 CABLE TO REMOTE CONTROLLER
RJ-11 CABLE TO TELEPHONE LINE
RJ-45 CABLE TO NETWORK HUB
LAPTOP
AC ADAPTER
ETHERNET CABLE
RJ-11 MODEM CABLE
15-PIN HD CABLE TO DISTRIBUTION
AMPLIFIER OR COMPUTER DISPLAY
BLACK, RED, AND YELLOW
RCA CONNECTORS FOR
AUDIO / VIDEO
TO AC SUPPLY OUTLET
400-0114-004
5
Page 7

DIAGRAM 2: DIMENSIONS

The PNP300 faceplate is shown here.
TOP VIEW
TABLETOP SOLUTIONS
10.033"
[255mm]
3.390"
[86mm]
R
9.530"
[242mm]
FRONT VIEW
(OPEN POSITION)
PNP300
Slim
2.190"
[56mm]
6.140"
[156mm]
2.890"
[73mm]
SIDE VIEW
(OPEN POSITION)
400-0114-004
6
Page 8

DIAGRAM 3: MOUNTING

The PNP300 faceplate is shown here.
TABLE
TOP
TABLETOP SOLUTIONS
SUPPORT
BRACKET
SET SCREW
SUPPORT
BRACKET
SET SCREW
SUPPORT MOUNT GROOVES ON THE SIDES OF THE BOX
R
PNP300
Slim
SUPPORT
GROOVES
400-0114-004
MOUNT
7
Page 9

DIAGRAM 4: CABLE CLAMPS

TABLETOP SOLUTIONS
TABLE
POWER CORD
400-0114-004
ATTACH THE POWER CORD TO A SECURED SURFACE OR TO THE TABLE WITH A CABLE CLAMP
8
Page 10
TABLETOP SOLUTIONS

INSTALLING YOUR PNP300/350 6

Step 1. Cut an opening into the table’s surface.
Refer to the ALTINEX website at
www.altinex.com for the cutout
requirements. Note: The table can be 0.25 in (6 mm) to
3.75 in (95 mm) thick. Always confirm dimensions before cutting to ensure that specifications have not changed.
Step 2. Place the support brackets under the
table and place them between the support mount grooves on the side of the PNP300/350 unit. Attach the brackets to the groove at the desired height and secure them to the bottom of the table using the setscrew. There are two support brackets, one for each side of the unit.
See DIAGRAM 3 for details.
Step 3. Secure the cables by using the provided
cable clamps of the type shown below.
PNP300:
AC power cable = AC power Black RCA cable = audio left Red RCA cable = audio right Yellow RCA cable = composite video Black DB-15 HD = computer video DB-9 cable = serial data Red RJ-45 cable = network Silver RJ-11 cable = telephone/modem
A round gray cable is also provided for connection to a stereo audio line.
PNP350:
AC power cable (2) = AC power Red RJ-45 cables (6) = for independent
network connections

OPERATION 7

7.1 OPERATING THE POP-UP PANEL

To raise the unit, push down on the center of the top cover of the PNP300/350 until a click is heard and then let go. The connector panel will pop up to allow access to the connectors.
Step 4. Pass the power cord from the bottom of
the housing and attach it to the bottom of the table using the cable clamp and screw supplied with the PNP300/350. Do not clamp the cord too tight or too loose.
See DIAGRAM 4 for an example of cable mounting the cables.
Step 5. Connect the appropriate cables with the
correct input connectors on the bottom of the unit. The following standard connections are provided:
400-0114-004
To lower the unit, disconnect all cables on the front connector panel. Then push down on the center of the top cover until the latch engages and the unit is locked in place.
9
Page 11
TABLETOP SOLUTIONS

TROUBLESHOOTING GUIDE 8

The PNP300/350 supplied unit was carefully tested and no problems were detected; however, we would like to offer these suggestions.
Please make sure that the highest quality video, audio, network, and telephone cables or connectors are used.
Make sure that no cable or power cord is damaged or pinched. If there has been damage, then do not use the PNP300/350 unit. Immediately contact the ALTINEX Customer Service Department to have the unit repaired.

ALTINEX POLICIES 9

9.1 LIMITED WARRANTY/RETURN POLICIES

Please see the ALTINEX website at
www.altinex.com for details on warranty and
return policies.

9.2 CONTACT INFORMATION ALTINEX, Inc.

592 Apollo Street Brea, CA 92821 USA
TEL: 714 990-2300 TOLL FREE: 1-800-ALTINEX WEB: www.altinex.com E-MAIL: solutions@altinex.com
400-0114-004
10
Loading...