ACCESSORIES
MANUAL PART NUMBER: 400-0057-003 PRODUCT REVISION: 3
PNP200 P
Pop ‘N Plug™ Interconnect Box
USER'S GUIDE
Page 2
ACCESSORIES
INTRODUCTION
Your purchase of the PNP200 Interconnect Box is greatly appreciated. We are sure you will find it reliable and simple to use.
Superior performance for the right price, backed by solid technical and customer support is what Altinex has to offer.
The product you are holding in your hands is designed using state-of-the-art technology and is superior to anything available on the market. You will find this and our other products reliable, long lasting, and simple to operate.
We are committed to providing our customers with signal management solutions to the most demanding audio-visual installations at very competitive pricing.
We appreciate your selection of our products and are confident that you will join the ranks of our many satisfied customers throughout the world.
TABLE OF CONTENTS
Page
PRECAUTIONS / SAFETY WARNINGS .................
GENERAL..........................................................2
INSTALLATION..................................................2
CLEANING.........................................................2
FCC / CE NOTICE .............................................2
ABOUT YOUR PNP200.........................................3
TECHNICAL SPECIFICATIONS............................3
PNP200 DIMENSIONS..........................................4
DIAGRAM 1........................................................4
DIAGRAM 2........................................................5
APPLICATION DIAGRAM .......................................
DIAGRAM 3........................................................6
DIAGRAM 4........................................................7
DIAGRAM 5........................................................8
INSTALLATION.....................................................9
This manual covers:
PNP200 – Pop `N Plug™ Interconnect Box.
OPERATION .......................................................10
LOCK, RELEASE, AND STATUS
CONTROL PIN.................................................10
HOW TO RELEASE AND REPLACE THE
GAS SPRING...................................................10
ACCESSORIES...................................................11
TROUBLESHOOTING GUIDE ............................12
ALTINEX POLICY ...............................................12
LIMITED WARRANTY......................................12
RETURN POLICY ............................................12
CONTACT INFORMATION ..............................12
1
1
Page 3
ACCESSORIES
PRECAUTIONS / SAFETY WARNINGS 1
Please read this manual carefully before using your PNP200 Interconnect Box. Keep this manual handy for future reference. These safety instructions are to ensure the long life of your PNP200 and to prevent fire and shock hazard. Please read them carefully and heed all warnings.
1.1 GENERAL
Unauthorized personnel shall not open the unit since there are high-voltage components inside.
Qualified Altinex service personnel, or their authorized representatives must perform all service.
1.2 INSTALLATION
For best results, place the PNP200 Interconnect Box in a dry area away from dust and moisture.
To prevent fire or shock, do not expose this unit to rain or moisture. Do not place the PNP200 Interconnect Box in direct sunlight, near heaters or heat radiating appliances, or near any liquid. Exposure to direct sunlight, smoke, or steam can harm internal components.
Handle the PNP200 Interconnect Box carefully. Dropping or jarring can damage internal components.
Never place fingers inside the openings in the back of the unit. This action could cause serious injury because of the sharp edges inside of the PNP200.
Do not place heavy objects on top of the PNP200. Do not use excessive force to push down on the top of the unit.
To turn off main power, disconnect the power cord, which powers the power socket on the PNP200 pop-up panels only, and unplug the 9V 500mA-power supply. The power outlet socket should be installed as near to the equipment as possible, and should be easily accessible.
We recommend using wall outlets with a Ground Fault Circuit Interrupter (GFCI) for maximum protection.
Install all cables according to the instructions. Do not force or pull out any cable or power cord that is attached to the PNP200 Interconnect Box.
1.3 CLEANING
Surfaces should be cleaned with a dry cloth. Never use strong detergents or solvents, such as alcohol or thinner. Do not use a wet cloth or water to clean the unit.
1.4 FCC / CE NOTICE
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including that which may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant, to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Any changes or modifications to the unit not expressly approved by Altinex, Inc. could void the user’s authority to operate the equipment.
2
2
Page 4
ACCESSORIES
ABOUT YOUR PNP200 2
The PNP200 is designed for installation into a conference room table. The Pop ‘N Plug™ Interconnect Box (PNP200) provides a means of connecting audio, video, control, and computer video sources into a presentation system. It is ideal for use together with Altinex computer video interfaces. The Pop ‘N Plug™ Interconnect Box can either “pop up” into a raised position to provide access to connectors or it can be lowered into a table when not in use. Using a tower-type construction with pneumatic suspension and an electromagnetic latching mechanism does this.
The Pop ‘N Plug™ Interconnect Box provides easy access to system inputs when they are needed. It also removes system inputs when not needed, eliminating the obstruction. The Pop ‘N Plug™ Interconnect Box has two input plates on either side of the unit, servicing both sides of a table. Each standard plate offers Computer Video (15-pin HD); Composite Video (RCA), Audio (RCA), Computer Audio (Stereo Mini), Modem (RJ-11), 9-pin D-type RS-232 and Network (RJ-45) input connections. All signals are passed through to a set of female connectors or cables. Several optional connectors can be substituted for the standard set of connectors.
The Pop ‘N Plug™ Interconnect Box is designed for use with tables ranging from one to three inches thick. It offers an adjustable retaining ring to secure the unit flush with the table’s surface. The Pop ‘N Plug™ comes in a standard matte black color. The top of the unit can be finished to match the table or it can be painted another color. This is available on the custom per order basis at an additional charge.
TECHNICAL SPECIFICATIONS 3
FEATURES/DESCRIPTION PNP200 GENERAL Front Panel Standard
Configuration Connectors
(side without fuse box) Power 1 IEC (standard) Computer Video 1 15-pin HD-F Composite Video 1 Yellow RCA F Audio, left, right 1 Black, 1 Red RCA F Audio 1 3.5 mm stereo F Telephone 1-RJ-11 F (6-position) Network 1 RJ-45 F (8-position) Control 1 DB-9 F
Back Panel Standard Configuration Connectors
(side with fuse box ) Power 1 IEC with 10 A fuse Computer Video 1 15-pin HD-F Composite Video 1 Yellow RCA Audio, left, right 1 Black, 1 Red RCA Audio 1 3.5 mm stereo Telephone 1-RJ-11 Network 1 RJ-45 Control 1 DB-9 F
Table 1. PNP200 General
MECHANICAL PNP200 Mechanical
Width (inches) 6.030in (153mm) Height (inches) 8.230in (209mm) Finish Black T° Operating 10°C-35°C T° Maximum 50°C Humidity
Table 2. PNP200 Mechanical
90% non-condensing
Power
Power for Operation 9V 500mA DC Power Consumption Max 10 watts Power Rating (pass through connector)
90-140 VAC, 2A Max
Table 3. PNP200 Electrical
3
3
Page 5
PNP200 DIMENSIONS 4
Diagrams: 1A, 1B, 1C, & 1D
PNP200 DIMENSIONS *(con’t)
ACCESSORIES
Diagram 2: Back View
4
4
Page 6
Diagram 2: Back View of PNP200
ACCESSORIES
5
5
Page 7
APPLICATION DIAGRAM 5
Diagram 3: Application
ACCESSORIES
6
6
Page 8
Diagram 4: Final Installation
ACCESSORIES
7
7
Page 9
Diagram 5: Table Cutout Requirements
ACCESSORIES
8
8
Page 10
INSTALLATION 6
Step 1. Make sure the gas spring is not
compressed when you remove the locking screw. To release the gas spring, push down and turn the knob in the center of the bottom of the PNP200 by 90 degrees. Remove the lock down screw from the PNP200. The locking screw is the smallest silver colored screw that is located on the bottom of the unit. Re­engage the gas spring by pushing down on the knob and turning it back to the original position, thereby locking the gas spring into place.
ACCESSORIES
Figure 2: Support Plate Step 4. Insert the PNP200 into the table. The
PNP200 can be adjusted to be flush or at
exactly the same level as the tabletop. Turning the four-socket head set screws on the top of the PNP200 does this. An allen wrench provided with the PNP200 is used to adjust the height level.
Figure 1: Gas Spring Step 2. Cut an opening into the table’s surface
using the dimensions of 7.38 in x 6.05in. Refer to diagram 5 on page 7 of the manual for table cutout requirements.
Note: The table can be 3 inches or thinner in thickness. Always confirm dimensions before cutting to insure that specifications have not changed.
Step 3. Place the support plate into the hole in the
table. The support plate is the square flat plate that can fit into the hole in the table (See Figure 2).
Step 5.Insert the four screws, which are provided,
into the adjustable retaining ring from bottom side of the table. The adjustable retaining ring allows securing unit to the table. The adjustable retaining ring is a flat square plate with two bent edges, that will not fit into the hole in the table.
Figure 3: Insertion of Screws into the Adjustable Retaining Ring
Step 6. Secure the cables by using the provided
mounting brackets. There are two mounting brackets (See Figure 4). Pass the power cord from the side of the housing and attach it to the surface with the cable-clamp supplied with the PNP200
9
9
Page 11
ACCESSORIES
unit. Do not keep the cord too tight or too loose (See Diagram 4, page 6).
Figure 4: Mounting Brackets
Step 7. Make that the provided ground wire
assembly is secured to the threaded nut located on the bottom of the housing of the PNP200 with a star-washer and a 4-40 screw as shown in Diagram 4, page 6.
Step 8.Attach the other end of the ground wire
assembly to a Protective Earth Ground with provided 6-32 screw and star-washer.
Step 9.Connect the appropriate cables with the
correct input connectors. There are two RCA connectors on each side of the PNP200. The black connectors are known as audio left, whereas the red connectors are called audio right. On either side of the unit, there is also a RCA video connector, which is yellow in color. The network connection is red; In addition, the telephone or data connection is gray.
Step 10. Once you have applied power and
connected the proper cables on the bottom of the unit, you may raise the unit. To raise the PNP200 into position, press the top of the unit.
Step 11. To lower the unit, push on the top of the
PNP200 until it fits into place. When the 9V DC adapter is plugged in, 9 volts must be applied. Once the 9 volts have been applied, the release top connection will be engaged. This mechanism allows the unit to lock into place, and then pop up when pressure is put on the top of the unit.
CONGRATULATIONS! YOU ARE DONE. ENJOY YOUR Pop `N Plug™ Interconnect Box.
If you experience any problems, please call
1-800-258-4623 or 1-714-990-2300 for
international calls.
OPERATION 7
7.1 LOCK, RELEASE, STATUS CONTROL PINS
To lock the position of the PNP200, connect the LOCK pin of the terminal block to GND. Note: the power supply is rated at 9V, but since the current demand of the PNP200 is low, it will reach 12 volts at the terminal block. If a regulated power supply is used, it should be a 12-volt power supply. A regulated power supply is when the power supply is at 12 volts, and when the power supply is at 9 volts, it is known as unregulated.
To release the top connector assembly, connect the RELEASE pin of the terminal block to GND.
To determine the status of the PNP200, examine the STATUS pin. The status pin should be a TTL digital level only. When the PNP200 is in an up position 5 volts is present, whereas 0 volts represents the down position.
7.2 HOW TO RELEASE AND REPLACE THE GAS SPRING
To replace the spring, push up, and turn the knob in the center on the bottom of the PNP200 by 90 degrees, thereby releasing the gas spring.
Unscrew the knob, and then unscrew the gas spring itself from the PNP200. Replace the gas spring with a new one by screwing it in, and then replacing the knob.
Re-engage the new gas spring by pushing up, and turning the knob by 90 degrees. After you have finished this step, you have completed the installation.
10
10
Page 12
ACCESSORIES
Under normal conditions the gas spring will last up to five years.
ACCESSORIES 8
Model No. Description
VGA MALE TO MALE (HD-15) HIGH RESOLUTION CABLE
CB37xxMR
CB39xxMR
CB5000PL­5VMxxxVM
CB5000PL­5VMxxxVF
CB5100PL­5VMxxxVM
CB5100PL-
xx = available length of 3ft, 6ft, 15ft, 25ft, 50ft, 75ft, 100ft, 150ft
VGA MALE TO FEMALE (HD-
15) HIGH RESOLUTION CABLE
xx = available length of 3ft, 6ft, 15ft, 25ft, 50ft, 75ft, 100ft, 150ft, 200ft, 250ft
SUPER HIGH RESOLUTION PLENUM-FLEX MULTI­CHANNEL COAX CABLE VGA MALE TO VGA MALE (HD-15)
xxx = available length of 3ft, 6ft, 15ft, 25ft, 50ft, 75ft, 100ft, 150ft, 200ft, 250ft
SUPER HIGH RESOLUTION PLENUM-FLEX MULTI­CHANNEL COAX CABLE VGA MALE TO VGA FEMALE (HD-15)
xxx = available length of 3ft, 6ft, 15ft, 25ft, 50ft, 75ft, 100ft, 150ft, 200ft, 250ft
SUPER HIGH RESOLUTION PLENUM-FLEX MULTI­CHANNEL COAX CABLE VGA MALE TO VGA FEMALE (HD-15)
xxx = available length of 3ft, 6ft, 15ft, 25ft, 50ft, 75ft, 100ft, 150ft, 200ft, 250ft
SUPER HIGH RESOLUTION PLENUM-FLEX MULTI­CHANNEL COAX CABLE VGA MALE TO VGA FEMALE (HD-15)
xxx = available length of 3ft,
11
5VMxxxVF
PC5301US PC5302UK PC5303AU PC5304GR
6ft, 15ft, 25ft, 50ft, 75ft, 100ft, 150ft, 200ft, 250ft
POWER CABLES
Power Cable for US Power Cable for UK Power Cable Australia Power Cable Germany
OPTIONAL CONNECTORS
Blank Connector (Snap-in and 15-pin location) BNC Female
4-pin Mini-DIN 6-pin Mini-DIN
11
Page 13
ACCESSORIES
TROUBLESHOOTING GUIDE 9
The PNP200 supplied unit was carefully tested and no problems were detected; however, we would like to offer these suggestions.
Please make sure that the Fuse is of a 10 Amps rating.
Please make sure that the highest quality video, audio, network, and telephone cables or connectors are used.
Make sure that the 9V DC adapter or the external regulated 12 volts is plugged into the power.socket for proper operation.
Make sure that any cable or power cord is not damaged or pinched. If it has been damaged, then do not use the PNP200 unit. Immediately contact the Altinex Customer Service Department to have
ALTINEX POLICY 10
10.1 LIMITED WARRANTY
Altinex warrants that its products and cables are free from defects in materials under normal use and service. This warranty is limited to repairing at company’s factory any part or parts of the product that shall within 2 years (90 days for cables) from date of shipment to the purchaser be returned to company with transportation charges pre-paid. The company’s examination shall disclose product(s) to be thus defective. The warranty is expressly in lieu of all other warranties expressed or implied. Altinex neither assumes nor authorizes any other person to assume for it any other liability concerning the sale of the products. This warranty shall not apply to any product that shall have been repaired or altered outside of company’s factory in any way so as, in its judgment, to affect its stability or reliability, or that has been subject to misuse, negligence or accident.
that an Altinex product needs to be returned please follow the policies below:
Altinex will accept all product returns for a period of 30 days from authorized Altinex dealers in an unopened package.
If a product has been opened, the restocking fees will apply. For the restocking fee, please contact an Altinex Sales Representative.
If the product is in your possession for more than 30 days, the restocking fees will apply.
Altinex will not accept any returns on cables or custom products.
If your product is in warranty and needs service, contact the Altinex Sales Department for an RMA (Return Material Authorization). Products returned without an RMA number may experience a delay in service.
If your product is out of warranty and needs service, contact the Altinex Sales Department for an RMA (Return Material Authorization). Products returned without an RMA number may experience a delay in service. The service charges will be quoted to you before the actual repairs are done.
10.3 CONTACT INFORMATION Sales Department
Phone: 714-990-2300 Fax: 714-990-3303
Accounting Department
Phone: 714-990-6088 Fax: 714-990-5778
10.2 RETURN POLICY
It is very important to Altinex that you receive all products that you have ordered and that this product fulfills your needs. In the unlikely event,