Altinex FSP107, FSP101, FSP-101C User Manual

DESIGNER SOLUTIONS
001
MANUAL PART NUMBER: 400-0520-
SP107-101/101C
FURNITURE MOUNT
INTERCONNECT BOX
USER’S GUIDE
TABLE OF CONTENTS
Page
PRECAUTIONS / SAFETY WARNINGS...............2
GENERAL..........................................................2
INSTALLATION PRECAUTIONS .......................2
CLEANING.........................................................2
FCC NOTICE .....................................................2
ABOUT YOUR SP107-101......................................3
TECHNICAL SPECIFICATIONS.............................3
PRODUCT DESCRIPTION..................................... 5
APPLICATION DIAGRAMS ....................................6
DIAGRAM1: CUTOUT DIMENSIONS................6
DIAGRAM2: DIMENSIONS ...............................7
DIAGRAM3:SP107-101INSTALLATION..........8
INSTALLING YOUR SP107-101/101C.................. 9
OPERATION.............................................................9
TROUBLESHOOTING GUIDE ...............................9
ALTINEX POLICIES ................................................9
LIMITED WARRANTY/RETURNPOLICIES.......9
CONTACT INFORMATION................................9
DESIGNER SOLUTIONS
1
DESIGNER SOLUTIONS

PRECAUTIONS / SAFETY WARNINGS 1

Please read this manual carefully before using your SP107-101 AV Interconnect. Keep this manual handy for future reference. These safety instructions are to ensure the long life of your SP107-101 and to prevent fire and shock hazards. Please read them carefully and heed all warnings.
1.1 GENERAL
Unauthorized personnel shall not open the unit.
There are high-voltage components inside.
Qualified ALTINEX service personnel or their
authorized representatives must perform all service.
1.2 INSTALLATION PRECAUTIONS
For best results, place the SP107-101 in a dry
area away from dust.
To prevent fire or shock, do not expose this unit
to water or moisture. Do not place the SP107-101 in direct sunlight, near heaters or heat-radiating appliances, or near any liquid. Exposure to direct sunlight, smoke, or steam can harm internal components.
Handle the SP107-101 carefully. Dropping or
jarring can damage the bezel.
Never place fingers inside the opening on either
side of the unit. This action could cause injury due to sharp edges inside.
Disconnect the SP107-101’s power cord to turn
off the main power. This supplies power to the AC sockets on the panel. The power outlet should be installed near the equipment and should be easily accessible.
We recommend using wall outlets with a Ground
Fault Circuit Interrupter (GFCI) for maximum protection.
Install all cables according to the instructions
found herein. Do not force or pull any cable or power cord that is attached to the SP107-101.
1.3 CLEANING
Surfaces should be cleaned with a dry cloth. Never use strong detergents or solvents such as alcohol or thinner. Do not use a wet cloth or water to clean the unit.
1.4 FCC NOTICE
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions found herein, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his expense.
Any changes or modifications to the unit not expressly approved by ALTINEX, Inc. could void the user’s authority to operate the equipment.
2
DESIGNER SOLUTIONS

ABOUT YOUR SP107-101 2

SP107-101
Surface Mount AV Interconnect Plate
The SP107-101 is designed for use in a table, podium, or other piece of furniture and is part of the many interconnection solutions offered by ALTINEX. It provides a means of connecting a laptop or other audiovisual equipment on the surface to a presentation system below the furniture or in another room. The SP107-101 offers interconnections for the most frequently used presentation inputs.
AC power
Computer audio and video
Network and USB
Female receptacles for power and computer signals are provided in the panel. The AC power cable is permanently attached to the SP107-101 and has a cord length of 10 ft (3 m). Short adapter cables are preinstalled at the factory for computer audio, HDMI, S-Video, USB, and network connections for ease of installation. Bulkhead connectors are provided for computer video, composite video, and left and right audio. Six foot extension cables are provided for all signal connections.
The SP107-101C is customizable and allows different connector types to be selected at the time of purchase. The AC receptacle and circuit breaker are fixed, but the other connectors can be replaced with other video, audio, and communication type connectors. For example, the 15-pin HD computer video input connector can be replaced with a 9-pin D-sub connector for serial communication. There are several options available for use in the network location. See the ALTINEX website for a complete list of available connector types including: RCA jacks, LED indicators, 4-pin Mini-DINs, etc.

TECHNICAL SPECIFICATIONS 3

Specifications are subject to change. See www.altinex.com for up-to-date information.
FEATURES/ DESCRIPTION
PASS-THROUGH AC Power
10 ft (3 m)
110 VAC, 60 Hz, 5 A NEMA F-M
Audio, Video, USB, and Network
8 in (203 mm)
Computer Audio 3.5mm F-F (1) Digital Video HDMI F-F (1) S-Video 4-pin Mini DIN F-F (1) USB Type-A F-F (1) Network RJ-45 F-F (1)
Bulkhead Connector
Computer Video 15-pin HD F-F (1) Composite Video RCA F-F (1)
Left & Right Audio RCA F-F (2)
Accessories Included
§ VGA, M-M
§ S-Video, M-M
Extension cables
6 ft (2 m)
Miscellaneous Hardware
§ RCA x3 (V, L, R), M-M
§ CAT-5, M-M
§ HDMI, M-M
§ USB Type-A, M-M
§ Audio 3.5mm, M-M
§ Mountings brackets
§ Mounting screws
SP107-101
Table 1. SP107-101 Description
3
DESIGNER SOLUTIONS
MECHANICAL SP107-101
Max. Table Thickness 3.0 in (76 mm) Width 6.4 in (163 mm) Depth 4.4 in (112 mm)
Height
(from surface down,
not including cables)
Net Weight SP107-101 2.4 lb (1.1 kg) Net Weight Extension Cables 2.2 lb (1.0 kg) Shipping Weight (approx.) 6.1 lb (2.8 kg) Material 0.062 in Aluminum
Finish T° Operating (T° Max) 10°C-35°C (40°C)
Humidity
3.0 in (76 mm)
Black paint, Fine texture
90% non-condensing
Table 2. SP107-101 Mechanical
ELECTRICAL SP107-101
Power Rating
(pass-through AC power)
120VAC, 60Hz, 15A
Table 3. SP107-101 Electrical
4

PRODUCT DESCRIPTION 4

DESIGNER SOLUTIONS
5

APPLICATION DIAGRAMS 5

DIAGRAM 1: CUTOUT DIMENSIONS
DESIGNER SOLUTIONS
6
DIAGRAM 2: DIMENSIONS
DESIGNER SOLUTIONS
7
DIAGRAM 3: SP107-101 INSTALLATION
DESIGNER SOLUTIONS
8
DESIGNER SOLUTIONS

INSTALLING YOUR SP107-101/101C 6

Step 1. Cut an opening into the furniture’s
surface. Note: The furniture can be 3” or less in
thickness. Always confirm dimensions before cutting to insure that specifications have not changed.
Step 2. Insert the SP107 -101/101C into the table
cutout.
Step 3. Refer to Diagram 3 and from underneath
the furniture surface, attach the mounting brackets to the 6-32 studs on the bottom side of the SP107-101/101C using the screws provided.
NOTE: If the surface is too thick for the
screws provided, longer 6-32 screws can be used.
Step 4. Secure the audio/video cables by using
cable clamps, tie wraps, or other standard mounting hardware. Pass the power cord from the bottom of the housing and attach it to the furniture separately from the audio/video cables.
Step 5. Connect the appropriate cables with the
correct input connectors on the bottom of the unit.
Step 6. The SP107-101/101C is now operational.

OPERATION 7

TROUBLESHOOTING GUIDE 8

The SP107-101/101C supplied was carefully tested and no problems were detected. However, we would like to offer the following suggestions:
Please make sure that the highest quality network cables are used.
Make sure that no cable or power cord is damaged or pinched. If there has been damage, do not use the SP107-101/101C. Please call the ALTINEX Customer Service Department at (714) 990-2300 to have the unit repaired.

ALTINEX POLICIES 9

9.1 LIMITED WARRANTY/RETURN POLICIES
Please see the ALTINEX website at
www.altinex.com for details on warranty and
return policies.
9.2 CONTACT INFORMATION
ALTINEX, Inc.
592 Apollo Street Brea, CA 92821 USA
TEL: 714 990-2300 TOLL FREE: 1-800-ALTINEX WEB: www.altinex.com E-MAIL: solutions@altinex.com
The SP107-101/101C requires no adjustments for performance. Once set-up, the SP107-101/101C will work trouble-free without user intervention.
Connect external devices to the appropriate connector on the SP107-101/101C.
9
Loading...