CONTACT INFORMATION ..............................10
SPECIAL APPLICATION
400-0522-002
1
SPECIAL APPLICATION
PRECAUTIONS / SAFETY WARNINGS1
Please read this manual carefully before using your
DA103-217 and keep it handy for future reference.
These safety instructions are to ensure the long life
of your DA103-217 and to prevent fire and shock
hazards. Please read them carefully and heed all
warnings.
1.1 GENERAL
•Do not open the unit or power supply, there are
high-voltage components inside.
•There are no user serviceable parts inside.
Qualified ALTINEX service personnel must
perform all service on the DA103-217.
1.2 HANDLING
•For best results, place the DA103-217 in a dry
area away from dust and moisture.
•To prevent fire or shock, do not expose this unit
to water or moisture. Do not place the
DA103-217 in direct sunlight, near heaters, or
heat-radiating appliances, or near any liquid.
Exposure to direct sunlight, smoke, or steam can
harm internal components.
•Handle the DA103-217 carefully. Dropping or
jarring can damage the unit.
•Do not pull any cables that are attached to the
DA103-217.
•Do not place heavy objects on top of the
DA103-217.
•If the DA103-217 Interface is not used for an
extended period, disconnect the adapter from
the wall to avoid fire, shock, and loss of power.
1.4 FCC NOTICE
•This device complies with Part 15 of the FCC
Rules. Operation is subject to the following two
conditions: (1) This device may not cause
harmful interference, and (2) this device must
accept any interference received, including
interference that may cause undesired
operation.
•This equipment has been tested and found to
comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable
protection against harmful interference when the
equipment is operated in a commercial
environment. This equipment generates, uses,
and can radiate radio frequency energy and if
not installed and used in accordance with
instructions found herein, may cause harmful
interference to radio communications. Operation
of this equipment in a residential area is likely to
cause harmful interference in which case the
user will be required to correct the interference
at his own expense.
•Any changes or modifications to the unit not
expressly approved by ALTINEX, Inc. could void
the user’s authority to operate the equipment.
1.3 CLEANING
•Unplug the DA103-217 adapter before cleaning.
•Clean only with a dry cloth. Never use strong
detergents or solvents such as alcohol or
thinner. Do not use a wet cloth or water to clean
the unit. Do not open the unit to clean.
400-0522-002
2
SPECIAL APPLICATION
ABOUT YOUR DA103-2172
DA103-217
VGA Line Receiver
• Recover signal after 250 ft of ultra-thin VGA cable
• Equalization/gain adjust for image optimization
• Compact and sturdy
• AGC control for sync restoration
• Internal or external EDID selection
The DA103-217 is a VGA line receiver for long
cable runs using RGBHV or VGA type cables. It
connects to the display end and allows adjustment
of video equalization, gain, and sync threshold to
recover degraded analog signals and improve
video quality. The DA103-217 can compensate for
up to 250 ft (76 m) of ultra thin VGA cable.
Cable runs over 75 ft (23 m) probably need and
should have this line receiver. In applications
without the DA103-217, customers may complain
about image smearing, blurriness, and other
distortions. The DA103-217 eliminates smearing
and other distortions while making letters and
graphics sharp and legible.
TECHNICAL SPECIFICATIONS3
Specifications are subject to change.
See www.altinex.com for up-to-date information.
FEATURES/
DESCRIPTION
Inputs
VGA15-pin HD F (1)
Output
Video15-pin HD F (1)
Power
DC Power (adapter)DC power jack (1)
Compatibility
Signal Types
Video Signal
Resolutions
EDID Memory
Accessories Included
DA103-217
RGB, RGsB, RGBS,
RGBHV, YPbPr
VGA through UXGA
480p through 1080i
Selectable for
internal or external
It is recommended to install the DA103-217 at the
display end for best results. Its small size allows
easy installation behind a display or in a ceiling
space while the metal enclosure provides strength
and protection for long life and reliability.
Other features include a signal present indicator
that shows when a signal is present, AGC control
for sync recovery, and internal or external EDID
selection for proper computer settings to match
display resolution.
400-0522-002
Video CableVGA to Display, 18 in
Power Adapter+9VDC, 1.1 A
Optional Accessories
Ultra-Thin VGA
Video Cable
Table 1. DA103-217 General
3
CB3000PV Series
SPECIAL APPLICATION
MECHANICALDA103-217
Material0.05 in Al
ColorSilver
Height0.7 in (18 mm)
Width3.8 in (97 mm)
Depth1.6 in (41 mm)
Weight0.2 lb (0.1 kg)
Shipping Weight (approx.)1.0 lb (0.5 kg)
T° Operating10°C-35°C
T° Maximum0°C-50°C
Humidity
MTBF (calculations)40,000 hrs (min.)
Table 2. DA103-217 Mechanical
90% non-condensing
ELECTRICALDA103-217
Video Adjustments
Gain0 to 3 dB
Sync Threshold0.5 to 4.5 V
EqualizationUp to 250 ft (76 m)
Input
Video Signal1.4 Vp-p max
Video Impedance75 ohms
Sync SignalTTL (+/-)
Sync Impedance10 kohms
Sync Threshold4.5 V nominal
Output
Video Gain0 dB +/- 0.5 dB nominal
Video Impedance75 ohms
Sync SignalTTL (+/-)
Sync Impedance22 ohms
Sync Polarity
Plus or Minus
(follows input)
Power Consumption
+9V250 mA
Total Power 2.25 W max
Table 3. DA103-217 Electrical
400-0522-002
4
PRODUCT DESCRIPTION4
SPECIAL APPLICATION
EDID SWITCH
INTERNAL/EXTERNAL
POWER 9V, 0.25A
POWER/SIGNAL PRESENT
RED = POWER
GREEN = SIGNAL PRESENT
400-0522-002
INPUT
VIDEOVIDEO
OUTPUT
5
APPLICATION DIAGRAMS5
DIAGRAM 1: TYPICAL SETUP
SPECIAL APPLICATION
400-0522-002
6
DIAGRAM 2: INTERNAL VIEW
SPECIAL APPLICATION
400-0522-002
7
SPECIAL APPLICATION
INSTALLING YOUR DA103-2176
Step 1. Determine ifthe computer needs to
receive available video resolutions from
the display device or from the internal
memory of the DA103-217. Set the EDID
switch to INT for using the DA103-217
internal memory or EXT to use the display
resolutions.
The switch is located on the side of the
unit and is accessible through a
rectangular opening.
Step 2. Using the video cable provided, connect
one end to the display and the other end
to the output of the DA103-217.
Step 3. Connect the long cable from the source to
the DA103-217 video input.
Step 4. Apply power to the DA103-217 using the
power adapter provided. The
Power/Signal Present LED will be RED if
there is power and no signal and GREEN
if a signal is present.
Step 5. Set the adjustment potentiometers as
follows:
OPERATION7
The DA103-217 will operate successfully as long
as cables are attached properly and other technical
specifications are followed.
The adjustments on the DA103-217 Line Receiver
are available to fine-tune the output image and to
compensate for errors induced by cable quality,
cable length, and variations in equipment.
7.1 ADJUSTMENTS
7.1.1 EQ
Video equalization is provided to fine-tune the
displayed image on the remote display.
Typically, for short cable runs the equalization
will be set to near minimum. Cable lengths up to
250 ft (76 m) will require near maximum
equalization.
7.1.2 GAIN
Video gain is provided to restore signal level and
brightness to the remote display. Typically, this
adjustment is made after the equalization has
been set.
7.1.3 SYNC ADJ
EQ ................. Minimum (full CCW)
GAIN .............Minimum (full CCW)
SYNC ADJ ....Midway (50%)
Step 6. If the image is visible, start by adjusting
the EQ until the image is clear. A 250 ft
(76 m) cable will require near maximum
equalization.
If there is no image, start by slowly
increasing the SYNC ADJ. Stop adjusting
when the image is visible.
Step 7. While viewing the image on the display,
fine-tune the image using the EQ and
GAIN adjustments for the best image.
Step 7. Next, fine-tune the SYNC ADJ for the best
image/screen position.
Step 8. The DA103-217 is now operational.
400-0522-002
The sync threshold adjustment allows changes
to be made in the sync processing circuitry and
to help recover and compensate for degraded
signals. Always start this adjustment with the
potentiometer set to the 50% position and make
adjustment in small increments.
8
SPECIAL APPLICATION
TROUBLESHOOTING GUIDE8
We have carefully tested and found no problems in
the supplied DA103-217; however, we would like to
offer suggestions for the following:
8.1 LED IS NOT RED
The LED should be ON and RED when power is
applied and there is no video signal present. If
the LED is ON and GREEN, the unit is receiving
power and a SYNC signal.
Cause 1:No AC power.
Solution:Verify the adapter is plugged into a
working AC outlet and that the outlet
has power.
Cause 2:Adapter is not plugged into
DA103-217.
Solution:Verify the DC power plug coming
from the AC adapter is plugged all
the way into the DA103-217.
Cause 3:The DA103-217 has a problem.
Solution:If there is AC power to the adapter
and the LED still does not turn on,
call ALTINEX at (714) 990-2300.
8.2 LED IS NOT GREEN
Cause 1:There is no power.
Solution:Disconnect the video input from the
DA103-217 and verify the LED is
ON and RED indicating power is
present. Reconnect the computer's
video output. If the LED is still not
GREEN see Cause 2.
Cause 2:There is no sync signal.
Solution:Verify the computer output is
operating correctly by connecting it
directly to the local monitor. If the
display is good, call ALTINEX at
(714) 990-2300.
8.3 NO REMOTE IMAGE
Cause 1:The source has a problem.
Solution:Check the image on the local
monitor and verify the quality is
good. If the local image is good, see
Cause 2.
Cause 2:Cable connections are incorrect.
Solution:Make sure that cables are
connected properly. Also, make sure
that the continuity and wiring are
good. If there is still no image
present, see Cause 3.
Cause 3:Video equalization required.
Solution:Adjust the EQ potentiometer on the
DA103-217.
In general, cable runs less then 50 ft
(15 m) require little or no video
equalization and should be set to
minimum to start. Cable runs up to
250 ft (76 m) will require maximum
equalization.
8.4 REMOTE IMAGE QUALITY IS POOR
Cause 1:The source has a problem.
Solution:Check the image on the local
monitor and verify the quality is
good. If the local image is good, see
Cause 2.
Cause 2Poor signal transmission.
Solution:Check the cables for continuity and
make sure that connections are
wired properly to verify that there is
good signal transmission. If the
image is still not correct, call
ALTINEX at (714) 990-2300.
Cause 3:Video equalization required.
Solution:Slowly adjust the EQ, GAIN, and
SYNC ADJ potentiometers on the
DA103-217while viewing the
display. If the image still cannot be
set correctly, call ALTINEX at
(714) 990-2300.