Altinex DA103-217 User Manual

SPECIAL APPLICATION
MANUAL PART NUMBER: 400-0522-002
DA103-217
VGA LINE RECEIVER
WITH VIDEO EQUALIZATION, GAIN,
AND SYNC ADJUSTMENTS
TABLE OF CONTENTS
Page
PRECAUTIONS / SAFETY WARNINGS............... 2
GENERAL..........................................................2
HANDLING ........................................................2
CLEANING.........................................................2
FCC NOTICE .....................................................2
ABOUT YOUR DA103-217.....................................3
TECHNICAL SPECIFICATIONS.............................3
PRODUCT DESCRIPTION.....................................5
APPLICATION DIAGRAMS ....................................6
DIAGRAM1: TYPICAL SETUP ..........................6
DIAGRAM2: INTERNAL VIEW ..........................7
INSTALLING YOUR DA103-217...........................8
OPERATION.............................................................8
ADJUSTMENTS.................................................8
TROUBLESHOOTING GUIDE ............................... 9
LED IS NOT RED...............................................9
LED IS NOT GREEN..........................................9
NO REMOTE IMAGE .........................................9
REMOTE IMAGE QUALITY IS POOR ................9
ALTINEX POLICIES ..............................................10
LIMITED WARRANTY/RETURN POLICIES.....10
CONTACT INFORMATION ..............................10
SPECIAL APPLICATION
400-0522-002
1
SPECIAL APPLICATION

PRECAUTIONS / SAFETY WARNINGS 1

Please read this manual carefully before using your DA103-217 and keep it handy for future reference. These safety instructions are to ensure the long life of your DA103-217 and to prevent fire and shock hazards. Please read them carefully and heed all warnings.
1.1 GENERAL
Do not open the unit or power supply, there are
high-voltage components inside.
There are no user serviceable parts inside.
Qualified ALTINEX service personnel must perform all service on the DA103-217.
1.2 HANDLING
For best results, place the DA103-217 in a dry
area away from dust and moisture.
To prevent fire or shock, do not expose this unit
to water or moisture. Do not place the DA103-217 in direct sunlight, near heaters, or heat-radiating appliances, or near any liquid. Exposure to direct sunlight, smoke, or steam can harm internal components.
Handle the DA103-217 carefully. Dropping or
jarring can damage the unit.
Do not pull any cables that are attached to the
DA103-217.
Do not place heavy objects on top of the
DA103-217.
If the DA103-217 Interface is not used for an
extended period, disconnect the adapter from the wall to avoid fire, shock, and loss of power.
1.4 FCC NOTICE
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with instructions found herein, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Any changes or modifications to the unit not expressly approved by ALTINEX, Inc. could void the user’s authority to operate the equipment.
1.3 CLEANING
Unplug the DA103-217 adapter before cleaning.
Clean only with a dry cloth. Never use strong
detergents or solvents such as alcohol or thinner. Do not use a wet cloth or water to clean the unit. Do not open the unit to clean.
400-0522-002
2
SPECIAL APPLICATION

ABOUT YOUR DA103-217 2

DA103-217
VGA Line Receiver
Recover signal after 250 ft of ultra-thin VGA cable
Equalization/gain adjust for image optimization
Compact and sturdy
AGC control for sync restoration
Internal or external EDID selection
The DA103-217 is a VGA line receiver for long cable runs using RGBHV or VGA type cables. It connects to the display end and allows adjustment of video equalization, gain, and sync threshold to recover degraded analog signals and improve video quality. The DA103-217 can compensate for up to 250 ft (76 m) of ultra thin VGA cable.
Cable runs over 75 ft (23 m) probably need and should have this line receiver. In applications without the DA103-217, customers may complain about image smearing, blurriness, and other distortions. The DA103-217 eliminates smearing and other distortions while making letters and graphics sharp and legible.

TECHNICAL SPECIFICATIONS 3

Specifications are subject to change. See www.altinex.com for up-to-date information.
FEATURES/ DESCRIPTION
Inputs
VGA 15-pin HD F (1)
Output
Video 15-pin HD F (1)
Power
DC Power (adapter) DC power jack (1)
Compatibility
Signal Types Video Signal
Resolutions EDID Memory
Accessories Included
DA103-217
RGB, RGsB, RGBS,
RGBHV, YPbPr
VGA through UXGA
480p through 1080i
Selectable for
internal or external
It is recommended to install the DA103-217 at the display end for best results. Its small size allows easy installation behind a display or in a ceiling space while the metal enclosure provides strength and protection for long life and reliability.
Other features include a signal present indicator that shows when a signal is present, AGC control for sync recovery, and internal or external EDID selection for proper computer settings to match display resolution.
400-0522-002
Video Cable VGA to Display, 18 in Power Adapter +9VDC, 1.1 A
Optional Accessories
Ultra-Thin VGA Video Cable
Table 1. DA103-217 General
3
CB3000PV Series
SPECIAL APPLICATION
MECHANICAL DA103-217
Material 0.05 in Al Color Silver Height 0.7 in (18 mm) Width 3.8 in (97 mm) Depth 1.6 in (41 mm) Weight 0.2 lb (0.1 kg) Shipping Weight (approx.) 1.0 lb (0.5 kg) T° Operating 10°C-35°C T° Maximum 0°C-50°C Humidity MTBF (calculations) 40,000 hrs (min.)
Table 2. DA103-217 Mechanical
90% non-condensing
ELECTRICAL DA103-217
Video Adjustments
Gain 0 to 3 dB Sync Threshold 0.5 to 4.5 V Equalization Up to 250 ft (76 m)
Input
Video Signal 1.4 Vp-p max Video Impedance 75 ohms Sync Signal TTL (+/-)
Sync Impedance 10 kohms
Sync Threshold 4.5 V nominal
Output
Video Gain 0 dB +/- 0.5 dB nominal
Video Impedance 75 ohms Sync Signal TTL (+/-) Sync Impedance 22 ohms
Sync Polarity
Plus or Minus
(follows input)
Power Consumption
+9V 250 mA
Total Power 2.25 W max
Table 3. DA103-217 Electrical
400-0522-002
4

PRODUCT DESCRIPTION 4

SPECIAL APPLICATION
EDID SWITCH
INTERNAL/EXTERNAL
POWER 9V, 0.25A
POWER/SIGNAL PRESENT
RED = POWER GREEN = SIGNAL PRESENT
400-0522-002
INPUT
VIDEOVIDEO
OUTPUT
5

APPLICATION DIAGRAMS 5

DIAGRAM 1: TYPICAL SETUP
SPECIAL APPLICATION
400-0522-002
6
DIAGRAM 2: INTERNAL VIEW
SPECIAL APPLICATION
400-0522-002
7
SPECIAL APPLICATION

INSTALLING YOUR DA103-217 6

Step 1. Determine if the computer needs to
receive available video resolutions from the display device or from the internal memory of the DA103-217. Set the EDID switch to INT for using the DA103-217 internal memory or EXT to use the display resolutions.
The switch is located on the side of the unit and is accessible through a rectangular opening.
Step 2. Using the video cable provided, connect
one end to the display and the other end to the output of the DA103-217.
Step 3. Connect the long cable from the source to
the DA103-217 video input.
Step 4. Apply power to the DA103-217 using the
power adapter provided. The Power/Signal Present LED will be RED if there is power and no signal and GREEN if a signal is present.
Step 5. Set the adjustment potentiometers as
follows:

OPERATION 7

The DA103-217 will operate successfully as long as cables are attached properly and other technical specifications are followed.
The adjustments on the DA103-217 Line Receiver are available to fine-tune the output image and to compensate for errors induced by cable quality, cable length, and variations in equipment.
7.1 ADJUSTMENTS
7.1.1 EQ
Video equalization is provided to fine-tune the displayed image on the remote display. Typically, for short cable runs the equalization will be set to near minimum. Cable lengths up to 250 ft (76 m) will require near maximum equalization.
7.1.2 GAIN
Video gain is provided to restore signal level and brightness to the remote display. Typically, this adjustment is made after the equalization has been set.
7.1.3 SYNC ADJ
EQ ................. Minimum (full CCW)
GAIN .............Minimum (full CCW)
SYNC ADJ ....Midway (50%)
Step 6. If the image is visible, start by adjusting
the EQ until the image is clear. A 250 ft (76 m) cable will require near maximum equalization.
If there is no image, start by slowly increasing the SYNC ADJ. Stop adjusting when the image is visible.
Step 7. While viewing the image on the display,
fine-tune the image using the EQ and GAIN adjustments for the best image.
Step 7. Next, fine-tune the SYNC ADJ for the best
image/screen position.
Step 8. The DA103-217 is now operational.
400-0522-002
The sync threshold adjustment allows changes to be made in the sync processing circuitry and to help recover and compensate for degraded signals. Always start this adjustment with the potentiometer set to the 50% position and make adjustment in small increments.
8
SPECIAL APPLICATION

TROUBLESHOOTING GUIDE 8

We have carefully tested and found no problems in the supplied DA103-217; however, we would like to offer suggestions for the following:
8.1 LED IS NOT RED
The LED should be ON and RED when power is applied and there is no video signal present. If the LED is ON and GREEN, the unit is receiving power and a SYNC signal.
Cause 1: No AC power.
Solution: Verify the adapter is plugged into a
working AC outlet and that the outlet has power.
Cause 2: Adapter is not plugged into
DA103-217.
Solution: Verify the DC power plug coming
from the AC adapter is plugged all the way into the DA103-217.
Cause 3: The DA103-217 has a problem.
Solution: If there is AC power to the adapter
and the LED still does not turn on, call ALTINEX at (714) 990-2300.
8.2 LED IS NOT GREEN Cause 1: There is no power.
Solution: Disconnect the video input from the
DA103-217 and verify the LED is ON and RED indicating power is present. Reconnect the computer's video output. If the LED is still not GREEN see Cause 2.
Cause 2: There is no sync signal.
Solution: Verify the computer output is
operating correctly by connecting it directly to the local monitor. If the display is good, call ALTINEX at (714) 990-2300.
8.3 NO REMOTE IMAGE Cause 1: The source has a problem.
Solution: Check the image on the local
monitor and verify the quality is good. If the local image is good, see Cause 2.
Cause 2: Cable connections are incorrect.
Solution: Make sure that cables are
connected properly. Also, make sure that the continuity and wiring are good. If there is still no image present, see Cause 3.
Cause 3: Video equalization required.
Solution: Adjust the EQ potentiometer on the
DA103-217. In general, cable runs less then 50 ft
(15 m) require little or no video equalization and should be set to minimum to start. Cable runs up to 250 ft (76 m) will require maximum equalization.
8.4 REMOTE IMAGE QUALITY IS POOR Cause 1: The source has a problem.
Solution: Check the image on the local
monitor and verify the quality is good. If the local image is good, see Cause 2.
Cause 2 Poor signal transmission.
Solution: Check the cables for continuity and
make sure that connections are wired properly to verify that there is good signal transmission. If the image is still not correct, call ALTINEX at (714) 990-2300.
Cause 3: Video equalization required.
Solution: Slowly adjust the EQ, GAIN, and
SYNC ADJ potentiometers on the DA103-217 while viewing the display. If the image still cannot be set correctly, call ALTINEX at (714) 990-2300.
400-0522-002
9

ALTINEX POLICIES 9

9.1 LIMITED WARRANTY/RETURN POLICIES
Please see the ALTINEX website at
www.altinex.com for details on warranty and
return policies.
9.2 CONTACT INFORMATION ALTINEX, Inc.
592 Apollo Street Brea, CA 92821 USA
TEL: 714 990-2300 TOLL FREE: 1-800-ALTINEX WEB: www.altinex.com E-MAIL: solutions@altinex.com
SPECIAL APPLICATION
400-0522-002
10
Loading...