Altech UL1077, UL508, UL489 General Product Line Information

Altech UL1077
Altech UL489 Altech UL508
4
The Altech Advantage
In todayʼs very competitive marketplace you need reliability, so you need to use circuit breakers that are high quality and technically correct for your application. Altech is a US leader in DIN rail mounted breakers with ratings up to 63A. Only Altech offers DIN rail mounted breakers that meet UL489, UL508 or UL1077 approvals with a short circuit interrupt capacity of up to 10kA. No other manufacturer offers this complete line. This assures you the right product for your application requirements.
If your application requires a manual motor controller, Altech is the leading US supplier of UL508 Manual Motor Controllers (MMC). In AC, we offer up to 60A in 1 to 3 poles at 480Y/277VAC. With 6 trip curves, Altech has the largest selection in the industry. This ensures you the selectivity you require for your application designs. Our MMCs have a 10kA short circuit withstand capacity, this is the highest rating in the industry. The AC version is rated up to 60A and is DC rated in 2 poles up to 80VDC.
Modern Look and Color
Dark blue handle and terminal caps enhance appearance and match imprint.
Marking Window
Large marking area with clear swivel window screen.
Standard Dual Connection Terminal
Standard box & ring tongue terminal are unique for the industry.
Reinforced Housing
Added ridges and new housing design improves overall product strength.
UL508
Manual Motor Controllers (MMC)
Provides the following features according to NEC
®
:
•Overload protection
•Switching function
•Disconnect function*
*when suitable for disconnect means
508 listed
E137938
C22.2 No.14 certified
LR104391
(up to 25A certain trip curves)
22
Altech UL508
SHORT CIRCUIT WITHSTAND RATINGS FOR V-EA MANUAL MOTOR CONTROLLER
UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
DIN Rail Mounted
17.5mm width per pole
Thermal Magnetic
480Y/277V AC, 50/60Hz
10kA Short Circuit
Withstand Capacity
Applications Include:
AC Motor Starting, Across the Line
AC General Use
AC Resistance
AC Discharge Lamps (Ballast)
AC Incandescent Lamps (Tungsten)
508 listed
E137938
C22.2 No.14 certified
LR104391
V-EA Series
Vol tage Rat ing
Short Circuit Withstand Rating (UL/CSA - Ratings)
Group Short Circuit Withstand Rating (UL/CSA - Ratings)
Interrupting Capacity (VDE - Ratings) Calibration Temperature Operating Temperature Storage Temperature Terminal Size Acceptability Ter mina l Tor que Terminal Protection Degree Horse Power Ratings Mechanical Endurance Ratings
480Y/277VAC
0.3-25A: 1 pole - 42VDC; 2 Pole - 80VDC 30-60A: 1 pole - 24VDC; 2 Pole - 60VDC
0.3-60A (RC): 10kA with UL-listed RK5 back-up fuse or MCCB
0.3-10A (RC): 10kA; 12-60A (RC): 5kA no branch circuit protection required
0.3-63A (RC): 10kA 40°C (104°F)
-25°C to 55°C (-13°F to 131°F)
-40°C to 70°C (-40°F to 158°F) Top: 18-3 AWG; Bottom: 18-2 AWG (Line/Load reversible) 20 lb.in. IP20 see page 32 see page 33
Backup UL-Listed UL-Listed No BCP Trip Protection RK5-Fuse MCCB Required Curve Amp Range up to 10kA up to 10kA up to:
all 0.3 - 10A 4xRC* 4xRC* 10kA
min 15A, max 70A min 15A, max 70A
all 12 - 30/32A 4xRC* 4xRC* 5kA
max 125A max 125A
all 40 - 50A 4xRC* 4xRC* 5kA
max 200A max 200A
all 60 / 63A 4xRC* 4xRC* 5kA
max 250A max 250A
*up to nearest rated current