Altech TSF1.5, TSF2.5 Catalog Page

FEED-THROUGH
PREVIOUS
HOME
NEXT
FIND IT
EUROSTRIPS
300V and 600V Standoff Feet Panel Mount
For wire-to-wire connections in HVAC, appliance, equipment, power distribution and other industrial applications with restricted budget and space requirements.
Easy to use double row terminal strips are a cost-effective alternative to barrier strips or other types of terminal blocks. Simply strip the wire, insert, and tighten the screw. feature tubular screw clamps, with or without wire protectors, and recessed screws and contacts to prevent shocks and shorts. The wire protectors include an integral wire stop in the center of the terminal. The stainless steel wire protectors exhibit excellent memory and the wire stop insures the most efficient connection.
Eurostrips described on this and the following page are available with standoff feet for increased wiring efficiency. They can be panel mounted or left to free float. Offered in easy to cut 12 pole strips, they can also be ordered precut with the required number of poles.
• Tubular Screw Clamp
• With or Without Wire Protectors
• Panel Mount or Free Float
• Housing Material: Polyamide 6.6
• Color: Opaque White
• Marking Plates or Factory Imprinted
®
a
Eurostrips
®
A
D
C
G
E
H
L
B
F
K
I
TSF1.5
Standoff Feet Pole Spacing 8mm (.315) Mounting Hole Diameter 2.8mm (.110) Stripping Length 5mm (.197)
A
D
C
J
M
O
N
G
E
H
L
B
F
I
J
K
O
N
M
TSF2.5
Standoff Feet Pole Spacing 10mm (.394) Mounting Hole Diameter 3.5mm (.138) Stripping Length 6mm (.236)
Ratings
IEC/VDE
(File No. E148805) (File No. LR38962)
Wire Range Current Voltage Wire Range Current Voltage
1.5mm
2
18A 380V 2.5mm
2
26A 380V 22-12 AWG 20A 600V 22-10 AWG 30A 600V 22-16 AWG 15A 300V 18-12 AWG 30A 600V
No. of Length (L) Std. Length (L) Std.
Ordering Information Poles Type Cat. No. mm (in.) Pk. Type Cat. No. mm (in.) Pk. Eurostrip®, Standoff Feet 2 TSF1.5/2wp 40.102 13.6 ( .53) 100 TSF2.5/2wp 40.302 17.0 ( .67) 100
with Wire Protector 3 TSF1.5/3wp 40.103 21.5 ( .85) 100 TSF2.5/3wp 40.303 27.0 (1.06) 100
4 TSF1.5/4wp 40.104 29.5 (1.16) 100 TSF2.5/4wp 40.304 37.0 (1.46) 100 5 TSF1.5/5wp 40.105 37.4 (1.47) 100 TSF2.5/5wp 40.305 47.0 (1.85) 100 6 TSF1.5/6wp 40.106 45.4 (1.79) 50 TSF2.5/6wp 40.306 57.0 (2.24) 50 7 TSF1.5/7wp 40.107 53.3 (2.10) 50 TSF2.5/7wp 40.307 67.0 (2.64) 50 8 TSF1.5/8wp 40.108 61.3 (2.41) 50 TSF2.5/8wp 40.308 77.0 (3.03) 50
Eurostrip®, Standoff Feet 2 TSF1.5/2 40.152 13.6 ( .53) 100 TSF2.5/2 40.352 17.0 ( .67) 100
without Wire Protector
b
3 TSF1.5/3 40.153 21.5 ( .85) 100 TSF2.5/3 40.353 27.0 (1.06) 100
4 TSF1.5/4 40.154 29.5 (1.16) 100 TSF2.5/4 40.354 37.0 (1.46) 100
For Accessories, please refer to pages 50, 51
Dimensions mm (in.)
I = 7.4 (.292) 0 = 14.0 (.552)
a
Clamp screws are zinc chromated steel. Stainless steel or nickle plated brass screws are available, consult Altech for ordering information.
b
Use for solid wire or wire with a ferrule.
A = 8.0 (.315) E = Ø2.8 (.110) J = 7.5 (.296) B = M2.5 x 4.3 F = Ø5.35 (.211) K = 10.1 (.398) C = 5.6 (.221) G = 8.0 (.315) M = 17.0 (.670) D = 2.4 (.095) H = Ø3.0 (.118) N = 18.2 (.716)
Dimensions mm (in.)
I = 6.1 (.240) O = 12.0 (.472)
A =10.0 (.394) E = Ø3.5 (.138) J= 9.5 (.374) B = M3 x 5.8 F = Ø5.7 (.225) K = 12.0 (.472) C = 6.4 (.252) G = 10.0 (.394) M = 19.4 (.764) D = 3.5 (.138) H = Ø3.6 (.142) N = 22.3 (.879)
46