Altech PSC-60 Series Catalog Page

OUTPUT
PROTECTION
ENVIRONMENT
SAFETY & EMC
OTHERS
PSC-60 Series
Type
Approved
ENERGY
SAVER
Features:
• Universal AC input (88-264V AC)
• Protections: Short Circuit / Overload / Overvoltage
• Brown-out protection
E361935
205412
E
• Installed on DIN rail TS35 / 7.5 or 15
• True DC OK signal output
• All wiring 105°C long life electrolytic capacitors
• High operation temperature up to 70°C
• Withstands 2G vibration test
• High efficiency, long life and high reliability
• 3 year warranty
• UL1310 Class 2 Power unit / LPS pass
• UL508 (Industrial control equipment) listed
Cat. No. PSC-6012 PSC-6015 PSC-6024 PSC-6048
DC VOLTAGE 12V 15V 24V 48V RATED CURRENT 5A 4A 2.5A 1.25A CURRENT RANGE 0 ~ 5A 0 ~ 4A 0 ~ 2.5A 0 ~ 1.25A RATED POWER 60W 60W 60W 60W RIPPLE & NOISE (max) 100mVp-p 100mVp-p 120mVp-p 180mVp-p
VOLTAGE ADJ. RANGE 10.8 ~ 13.2V 13.5 ~ 16.5V 21.6 ~ 26.4V 43.2 ~ 52.8V VOLTAGE TOLERANCE ±1.0% ±1.0% ±1.0% ±1.0%
LINE REGULATION ±1.0% ±1.0% ±1.0% ±1.0% LOAD REGULATION ±1.0% ±1.0% ±1.0% ±1.0% SETUP, RISE TIME < 800ms, < 50ms / 230VAC at full load
HOLD UP TIME (Typ.) > 32ms / 230VAC; >16ms / 115VAC at full load VOLTAGE RANGE 88 ~ 264VAC; 124 ~ 370VDC
FREQUENCY RANGE 47~63Hz EFFICIENCY (Typ.) 86% 87% 87% 88% AC CURRENT (Typ.) 1.3 A / 115VAC; 0.6A / 230VAC INRUSH CURRENT (Typ.) COLD START 30A / 115VAC; 60A / 230VAC LEAKAGE CURRENT <1mA / 230VAC
OVER LOAD PROTECTION > 102% rated output power
OVER VOLTAGE PROTECTION 115% ~ 150% rated output voltage
OVER TEMPERATURE PROTECTION Power supply shut down at 70˚C constant current limiting / output voltage goes to 0;
WORKING TEMP. -20 ~ +70˚C (Refer to output load derating curve) WORKING HUMIDITY 20 ~ 90% RH non-condensing STORAGE TEMP. / HUMIDITY -40 ~ +85˚C; 10 ~ 95% RH TEMP. COEFFICIENT ±0.03% / ˚C (0 ~ 50˚C) VIBRATION 10 ~ 500Hz, 2G 10min. / 1cycle, 60 min. each long X,Y, Z axes
SAFETY STANDARDS UL508, TUV EN60950-1:2006+A11, UL1310 NEC class 2 compliant WITHSTAND VOLTAGE I/P-O/P: 4242DC, I/P-FG: 2121DC 1minute ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC EMI CONDUCTION & RADIATION EN55022: 2006 Class B HARMONIC CURRENT EN61000-3-2: 2006 Class A, EN61000-3-3: 1995+A1: 2001+A2: 2005 EMS IMMUNITY EN61204-3: 2000, EN55024: 1998+A1:2001+A2: 2003 light industry level, criteria A
DC OK Signal Relay contact (24VDC / 1A, 120VAC / 1A) MTBF 944.6K HRS MIL-HDBK-217F DIMENSION 40x90x99 mm (WxHxD) PACKING 0.3kg; 27pcs / 9.3kg CONNECTION I/P: 3 poles, O/P: 6 poles screw DIN terminal COOLING Free air convection
Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor
Tolerance: includes set up tolerance, line regulation and load regulation.
ength of set up time is measured at sold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
L
Derating may apply in low input voltage. Please check the derating curve for more details.
Protection type: Constant current limiting, recovers automatically after fault condition is removed
Protection type: latch-off mode
re-power on to recover
The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that is still meets EMC directives.
All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25˚C of ambient temperature.
26
For the latest on Altech Power Supplies please visit www.altechcorp.com/power.
Block Diagram
DC OK Relay Contact
Derating Curve
85
Ta=25°C
100 110 120 264VAC
40
50
60
70
80
Loa
d
( %)
Load V .S I/P V oltage
Input Voltage(VAC)60Hz
90
100
-20
Ambient Temperature (°C)
0 10 20 30 40 50 60 70
20
40
60
80
100
Loa d (% )
Load V .S Temp.
Mechanical Specification
N L
40
90
99
OO..VV..PP..
II //PP
EE MMII
FFIILLTT EERR
RREE CCTT IIFF IIEE RR SS
&
&
FFIILLTT EERR
PPOO WWEE RR
SS WWIITTCCHHII NNGG
DDEE TTEE CCTT IIOO NN
CC IIRRCC UUIITT
OO..LL ..PP ..
++VV
--VV
CC OO NNTTRR OOLL
RREE CCTT IIFF IIEE RR SS
&&
FFIILLTT EERR
OO..CC..PP ..
DDCC OO KK
DDCC OO KK
Contact Close
Contact Ratings (max.)
Contact Open
When the output voltage reaches the adjusted output voltage
When the output voltage drop below 90% rated output voltage
30V / 1A resistive load
U
nit : mm / inch
Pin No.
Pin No.
1
1,2
2
3,4
3
Assi gnment
Assignment
FG
AC/L
AC/N
DC OUTPUT +V DC OUTPUT -V
5,6
DC OK RELAY CONTACT
Terminal Pin. No Assign. (TB1)
Terminal Pin. No Assign. (TB2)
PSC-60 Series
Type
Approved
ENERGY
SAVER
E361935
205412
E
Altech Corp.®• 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490