MINIATURE DIAZED NEOZED CYLINDER
Mini fuses in five sizes to 20 Amps.
•Slow Blow
•Medium Blow
•Fast Blow
•Super Fast Blow
Fuses
"Bottle" fuses in five sizes to 200 Amps.
• gL/gG -Slow Blow
-Fast Blow
• gR -Semiconductor
Fuses
4-5
Accessories
Protection
6-7
10-11
Compact fuses in three sizes to 100 Amps.
• gL/gG -Slow Blow
• gR -Semiconductor Protection
Fuses Accessories
8-9
10-11
Standard cylinder fuses are available in four sizes to 125 Amps, with or without blown fuse Indicator Pins.
• gI/gF-Line Protection
• aM -Motor Protection
• gR -Semiconductor Protection
Cylinder Bolt fuses are available in two diameters with multiple fixing centers.
• gR -Semiconductor Protection
Fuses - Standard Fuses - Bolt Accessories
12-13
NH
Knife Blade or Stud Mount designs in six sizes with cur­rent ratings of 2 to 1600 Amps.
• gL/gG-Line Protection
• aM -Motor Protection
• gR/aR -Semiconductor Protection
Fuses
14
Accessories
15
16-21
19
ITALIAN
Cylinder style fuses available in four sizes with current ratings from 2 to 100 Amps.
• gI -Line Protection
Fuses
Siemens Cross Reference
Altech Corp.
BRITISH ACCESSORIES
SQUARE BODY
British Line Proection fuses are available with four mounting plate designs with current ratings from 2 to 63 Amps.
•gG-Line Protection British Semiconductor fuses
are available in single and double body units with multiple diameters and fixing centers.
•aR -Semiconductor Protection
Fuses - Line
22
Fuses - Semi.
34-35
®
35 Royal Road Flemington NJ 08822-6000Phone (908) 806-9400Fax (908) 806-9490 www.altechcorp.com
24-25
Square body fuses for semi­conductor devices to 1000 Amps.
• aR -Semiconductor Protection
Fuses
23
Accessories
26-31
HIGH VOLTAGE
Fuses for distribution circuits in four sizes to 36KV.
Fuses
19
• Screw Caps
• Adapter Screws and Rings
• Fuse Base Covers
• Fuse Bases
• Tools
• End Plates
• Microswitches
• Terminal Covers
• Fuse Handles
32-33
10-11, 15, 19
3
NEOZED
PREVIOUS
HOME
NEXT
FIND IT
Neozed Fuses are more compact than the Diazed Fuses. Three sizes are available, D01 to 16 Amps, D02 to 63 Amps and D03 to 100 Amps. Fuse accessories are sized to match. Each size fuse body has a different diameter to fit only into the appropriate Screw Cap and Fuse Base. (See illustration pg
10.) Also, the fuse tips have different
diameters, depending on their current rating. The diameter of the tip matches the diameter of the hole in the Adapter Ring to insure that no fuse with a higher rating than intended for the circuit can be installed. This prevents damage to the circuit or equipment the fuse protects. Additionally, fuses and Adapter Rings are color coded to avoid mismatching; for example: 10 Amp Neozed fuses have red pop-out indicators on their head, matching the red 10 Amp Adapter Ring.
When a Neozed fuse has blown, the color coded indicator on the head of the fuse will pop out, giving visible indication through a glass window in the Screw Cap.
The Fuse is held in place by the Screw Cap, which is screwed into the Fuse Base. Neozed Fuse Bases are available in one and three pole designs. Fuse Bases can be panel mounted or snapped onto a standard 35mm DIN rail.
Operating Classes gL/gG - Slow Blow
Protect cable, conductors, and equip­ment from damage due to overload and short circuits.
Typical Markings: gL/gG
gR - Semiconductor Protection
Protects semiconductors like diodes, SCRs, etc. Current limiting super fast blow characteristic for short circuit protection.
Typical Markings: Ultra Rapid™, Ultra Quick™, Recticur™, gR,
Mostly red, orange, or blue imprint.
Ordering Information
Slow Blow - Operating Class gL/gG (VDE 0636 / IEC 269) Cable, Line , and Equipment Protection up to 380V AC and 250V DC
Semiconductor Protection - Operating Class gR (VDE 0636 / IEC 269) Semiconductor Protection up to 440V AC and 250V DC
Screw Cap (pgs 10-11)* Adapter Ring (pgs 10-11)*
(Install only with Adapter Ring Tool) Adapter Ring Tool (pgs 10-11)*
(for inserting or removing all Adapter Rings)
Fuse Base, Single Pole (pgs 10-11)* Fuse Base, Three Pole (pgs 10-11)*
Fuse Base Cover, Single Pole (pgs 10-11)* Fuse Base Cover, Three Pole (pgs 10-11)*
D01
Current/ Color Std.
Voltage Cat. No. Code Pk.
2/380V AC 2NZ01GL Pink 10 4/380V AC 4NZ01GL Brown 10
6/380V AC 6NZ01GL Green 10 10/380V AC 10NZ01GL Red 10 16/380V AC 16NZ01GL Gray 10
2/440V AC 2NZ01SC Pink 5
4/440V AC 4NZ01SC Brown 5
6/440V AC 6NZ01SC Green 5 10/440V AC 10NZ01SC Red 5 16/440V AC 16NZ01SC Gray 5
NZ01C 1
refer to pgs 10-11
NAT 1
NZ01B 1
NZ01B3 1
NZ01BC 1
NZ01BC3 1
Ø11mm (.43 in.)
Altech Corp.
8
36mm
(1.42in.)
*Refer to page indicated for additional selection and ordering information.
®
35 Royal Road Flemington NJ 08822-6000Phone (908) 806-9400Fax (908) 806-9490www.altechcorp.com