INDICATOR/ DIODE CIR-
CUITS
35 or 32mm DIN Rail
Altech offers different types of
terminals incorporating electronic components for signal
converting, circuit protection
and status indication. Based on
customer requirements, specially assembled terminals are
offered.
CDL4U(E)D1/D2 CDL4U(E)D3
With arc suppression circuit for
contactors and solenoid valves - DC
Diode circuit for
reverse polarity protection
CDL4U(O) - Double level terminal with open lower current bar
to accommodate electronic
components like diodes, resistors, LEDs, etc.
Diode Specifications
Diode 1N 4007
Diode Reverse Voltage 1000 V
Diode Current 1 A
COLOR BLOCKS
(other than grey standard)
When ordering please add
color suffix to Cat. No.
Example: CTS2.5U-N/R
Terminal Width
Height x Length
Terminal Voltage
Stripping Length
Approvals
Wire Range
Voltage Rating
Current Rating
Torque
Terminal Block
End Plate
DIN Rail
for ordering information
refer to page 62
End Stop
for ordering information
refer to page 63
Internal
Jumper
Current
Bars
10 pole (breakable)
Shorting Sleeve & Screw
Marking Tags (MT Type)
2 pole
3 pole
4 pole
10 pole
2 pole
3 pole
4 pole
10 pole
100 pole
6 mm
54 x 55.5 mm
300 V~
9 mm
E220514 E220514
22-10 AWG 0.5-4 sq.mm 22-10 AWG
600 V 400 V 600 V
25 A 32 A 35 A
7 lb-in 0.5 Nm 7 lb-in
Cat. No. Std. Pk.
CDL4U(E)D1 100
CDL4U(E)D2 100
EPCDL4U 50
CA702 50
CA802 50
CA727/2 10
CA727/3 10
CA727/4 10
CA727/10 10
CA703/1 100
CA704/1 100
CA705/1 100
CA732/10 100
CA732/10-A 100
CA732/100 10
CA607/S/Q 100
MT2 100
6 mm
54 x 55.5 mm
300 V~
9 mm
22-10 AWG 0.5-4 sq.mm 22-10 AWG
600 V 400 V 600 V
25 A 32 A 35 A
7 lb-in 0.5 Nm 7 lb-in
Cat. No. Std. Pk.
CDL4U(E)D3 100
EPCDL4U 50
CA702 50
CA802 50
CA727/2 10
CA727/3 10
CA727/4 10
CA727/10 10
CA703/1 100
CA704/1 100
CA705/1 100
CA732/10 100
CA732/10-A 100
CA732/100 10
CA607/S/Q 100
MT2 100
Color Ordering Suffix
Red R
Blue BU
Black BL
Orange O
Green G
Yellow Y
White W
Beige BG
Dark Brown DB
D1
D2
D3
CDL4U(E)DD1/DD2 CDL4U(E)DD3/DD4
CDL4U(E)D4 CDL4U(E)DD5
Diode circuit for lamp testing Diode circuit for lamp testing
6 mm
54 x 55.5 mm
300 V~
9 mm
E220514 E220514 E220514 E220514
22-10 AWG 0.5-4 sq.mm 22-10 AWG
600 V 400 V 600 V
25 A 32 A 35 A
7 lb-in 0.5 Nm 7 lb-in
Cat. No. Std. Pk.
CDL4U(E)DD1 100
CDL4U(E)DD2 100
EPCDL4U 50
6 mm
54 x 55.5 mm
300 V~
9 mm
22-10 AWG 0.5-4 sq.mm 22-10 AWG
600 V 400 V 600 V
25 A 32 A 35 A
7 lb-in 0.5 Nm 7 lb-in
Cat. No. Std. Pk.
CDL4U(E)DD3 100
CDL4U(E)DD4 100
EPCDL4U 50
Diode circuit for lamp testing with
LED series resistance
6 mm
54 x 55.5 mm
24 V–
9 mm
22-10 AWG 0.5-4 sq.mm 22-10 AWG
600 V 400 V 600 V
25 A 32 A 35 A
7 lb-in 0.5 Nm 7 lb-in
Cat. No. Std. Pk.
CDL4U(E)D4 100
EPCDL4U 50
Diode circuit for lamp testing with
LED series resistance
6 mm
54 x 55.5 mm
24 V~
9 mm
22-10 AWG 0.5-4 sq.mm 22-10 AWG
600 V 400 V 600 V
25 A 32 A 35 A
7 lb-in 0.5 Nm 7 lb-in
Cat. No. Std. Pk.
CDL4U(E)DD5 100
EPCDL4U 50
CA702 50
CA802 50
CA727/2 10
CA727/3 10
CA727/4 10
CA727/10 10
CA703/1 100
CA704/1 100
CA705/1 100
CA732/10 100
CA732/10-A 100
CA732/100 10
CA607/S/Q 100
MT2 100
DD2 DD4
CA702 50
CA802 50
CA727/2 10
CA727/3 10
CA727/4 10
CA727/10 10
CA703/1 100
CA704/1 100
CA705/1 100
CA732/10 100
CA732/10-A 100
CA732/100 10
CA607/S/Q 100
MT2 100
DD3 DD1
CA702 50
CA802 50
CA727/2 10
CA727/3 10
CA727/4 10
CA727/10 10
CA703/1 100
CA704/1 100
CA705/1 100
CA732/10 100
CA732/10-A 100
CA732/100 10
CA607/S/Q 100
MT2 100
D4
CA702 50
CA802 50
CA727/2 10
CA727/3 10
CA727/4 10
CA727/10 10
CA703/1 100
CA704/1 100
CA705/1 100
CA732/10 100
CA732/10-A 100
CA732/100 10
CA607/S/Q 100
MT2 100
DD5
CDL4U(E)N1 CDL4U(E)LD5*
CDL4U(E)LD3*
Terminal Width
Height x Length
Terminal Voltage
Stripping Length
Approvals
Wire Range
Voltage Rating
Current Rating
Torque
Terminal Block
End Plate
DIN Rail
for ordering information
refer to page 62
AC voltage indicator with neon lamp
6 mm
54 x 55.5 mm
100 V~ to 220 V
9 mm
E220514 E220514 E220514
22-10 AWG 0.5-4 sq.mm 22-10 AWG
600 V 400 V 600 V
25 A 32 A 35 A
7 lb-in 0.5 Nm 7 lb-in
Cat. No. Std. Pk.
CDL4U(E)N1 50
EPCDL4U 50
AC voltage indicator with LED
6 mm
54 x 55.5 mm
24 V~, 48 V~, 120V~, 220V~
9 mm
22-10 AWG 0.5-4 sq.mm 22-10 AWG
600 V 400 V 600 V
25 A 32 A 35 A
7 lb-in 0.5 Nm 7 lb-in
Cat. No. Std. Pk.
CDL4U(E)LD5* 50
EPCDL4U 50
AC/ DC voltage indicator with LED
6 mm
54 x 55.5 mm
12 V~, 24 V
~
9 mm
22-10 AWG 0.5-4 sq.mm 22-10 AWG
600 V 400 V 600 V
25 A 32 A 35 A
7 lb-in 0.5 Nm 7 lb-in
Cat. No. Std. Pk.
CDL4U(E)LD3* 50
EPCDL4U 50
End Stop
for ordering information
refer to page 63
Internal
Jumper
2 pole
3 pole
4 pole
10 pole
Current
Bars
2 pole
3 pole
4 pole
10 pole
10 pole (breakable)
100 pole
Shorting Sleeve & Screw
Marking Tags (MT Type)
CA702 50
CA802 50
CA727/2 10
CA727/3 10
CA727/4 10
CA727/10 10
CA703/1 100
CA704/1 100
CA705/1 100
CA732/10 100
CA732/10-A 100
CA732/100 10
CA607/S/Q 100
MT2 100
N1
CA702 50
CA802 50
CA727/2 10
CA727/3 10
CA727/4 10
CA727/10 10
CA703/1 100
CA704/1 100
CA705/1 100
CA732/10 100
CA732/10-A 100
CA732/100 10
CA607/S/Q 100
MT2 100
LD5
CA702 50
CA802 50
CA727/2 10
CA727/3 10
CA727/4 10
CA727/10 10
CA703/1 100
CA704/1 100
CA705/1 100
CA732/10 100
CA732/10-A 100
CA732/100 10
CA607/S/Q 100
MT2 100
LD3
* Add required voltage to part number as a suffix
i.e. CDL4U(E)LD5/110 is for 110V.
CDL4U(E)LD4* CDL4U(E)LD1/LD2
CDL4U(E)L1/L2* CDL4U(O)
AC/ DC voltage indicator with LED
6 mm
54 x 55.5 mm
~
24 V
9 mm
E220514 E220514 E220514 E220514
22-10 AWG 0.5-4 sq.mm 22-10 AWG
600 V 400 V 600 V
25 A 32 A 35 A
7 lb-in 0.5 Nm 7 lb-in
Cat. No. Std. Pk.
CDL4U(E)LD4* 50
EPCDL4U 50
DC voltage indicator with LED
6 mm
54 x 55.5 mm
24 V–
9 mm
22-10 AWG 0.5-4 sq.mm 22-10 AWG
600 V 400 V 600 V
25 A 32 A 35 A
7 lb-in 0.5 Nm 7 lb-in
Cat. No. Std. Pk.
CDL4U(E)LD1 50
CDL4U(E)LD2 50
EPCDL4U 50
DC voltage indicator with LED Electronic Component Carrier
6 mm
54 x 55.5 mm
6 V–, 24 V–, 60 V–
9 mm
22-10 AWG 0.5-4 sq.mm 22-10 AWG
600 V 400 V 600 V
25 A 32 A 35 A
7 lb-in 0.5 Nm 7 lb-in
Cat. No. Std. Pk.
CDL4U(E)L1* 50
6 mm
54 x 55.5 mm
–
9 mm
22-10 AWG 0.5-4 sq.mm 22-10 AWG
600 V 400 V 600 V
25 A 32 A 35 A
7 lb-in 0.5 Nm 7 lb-in
Cat. No. Std. Pk.
CDL4U(O) 100
CDL4U(E)L2* 50
EPCDL4U 50
EPCDL4U 50
CA702 50
CA802 50
CA727/2 10
CA727/3 10
CA727/4 10
CA727/10 10
CA703/1 100
CA704/1 100
CA705/1 100
CA732/10 100
CA732/10-A 100
CA732/100 10
CA607/S/Q 100
MT2 100
Altec h Corp. ® • 35 R oyal R oad • Flemington, NJ 08822-60 0 0 • Phone (908)806-940 0 • F AX (908)806-9490 • www .altec hcorp.com
CA702 50
CA802 50
CA727/2 10
CA727/3 10
CA727/4 10
CA727/10 10
CA703/1 100
CA704/1 100
CA705/1 100
CA732/10 100
CA732/10-A 100
CA732/100 10
CA607/S/Q 100
MT2 100
LD4
LD2
CA702 50
CA802 50
CA727/2 10
CA727/3 10
CA727/4 10
CA727/10 10
CA703/1 100
CA704/1 100
CA705/1 100
CA732/10 100
CA732/10-A 100
CA732/100 10
CA607/S/Q 100
MT2 100
L1 LD1
L2
CA702 50
CA802 50
CA727/2 10
CA727/3 10
CA727/4 10
CA727/10 10
CA703/1 100
CA704/1 100
CA705/1 100
CA732/10 100
CA732/10-A 100
CA732/100 10
CA607/S/Q 100
MT2 100
* Add required voltage to part number as a suffix