Sensing Range
Magnetic distance35mm/typ
Power source
Coin Cell Battery CR2032
Battery Lifetime
Approx. 2 years at 25 (77)
Operating Temperature
-10 ~ 50 [ °C]
Storage Temperature
-10 ~ 60
Relative Humidity
up to 85% non-condensing
RF Performance Requirements
- Protocols : Zigbee Green Power
: IEEE802.15.4 CH11 to CH26
Introduction
Entry Sensor is constructed on the basis of ZigBee HA1.2 standard.
The main body and subsidiary parts are installed respectively at the edge of the doors or windows.
immediately.
- Low cost Zigbee HA compliant solution
- Periodic zone status reporting
- Periodic battery status and low battery reporting
- Small form factor
- Magnet Sensor Switch type
- Whole home coverage
This product requires the Ethernet Gateway to connect to the Internet.
Specifications
Page 2 of 6
Pairing Mode
The entry sensor can be paired using either the mobile app or Ethernet gateway.
Pairing A APP
1. Start sensor registration wizard in the mobile app and follow steps.
Run applicationMenu icon ( )DevicesAdd DevicesAdd motion sensor(w/o QR code)
2. Remove battery tab on the motion sensor .The sensor will attempt to pair automatically. Note : The
green LED blinks while the sensor is on pairing mode (max. 30seconds.)
3. The application should advance when the sensor is registered.
You can change the device name after it is application to see if the sensor is registered.
Pairing BGateway
1. Press pairing button on gateway.
2. Gateway will trigger pairing mode automatically
Orange LED blinks while the gateway is on pairing mode.
3. Remove the battery tab on the entry sensor to put it into pairing mode.
Note : Green LED blinks while the sensor is on pairing mode (max. 30seconds.)
Pairing failure
The pairing is failed if the LEDs on device still blinks over 30 seconds or entry sensor is not registered on
mobile application within 30 seconds.
Please retry pairing with following instruction if it didnt work the first time.
1,2 Same as step 1 & 2 on pairing A, B
3. If battery tab is already removed, press pairing button on motion sensor to put it into pairing mode.(Green LED blinks while the
sensor is on pairing mode)
4.Once Green LED is turned off, please check application to see if the sensor is registered.
Page 3 of 6
Product Description
Dimension
(Sensor Module) 51x30x13mm
(Magnetic Module) 45x13x13mm
Page 4 of 6
Operation flow
~ If the sensor application is commissioned before. Commissioning will be restored au-
tomatically, ~otherwise : Powering up or Press the Pair button to start commissioning, and the
Green LED will be blink with 1s period ~ To start decommissioning, press and hold the Pair button for 3s, and decommission-
ing will be started and the Green LED will be on for 2s ~ If the entry sensor is commissioned
the sensor status will be reported to the target regularly
The Zone report will be send to the gateway when the door is opened/closed or the tamper switch is opened/closed. When the battery voltage is low than 2.4Vthe sensor send the low battery status to the gateway.
FCC Compliance Statement
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to pro­vide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the re­ceiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help. Changes or Modifications not expressly approved by the party responsible could void
the user’s authority to operate this device.
Page 5 of 6
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions : (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment complies with the FCC RF radiation exposure limits set forth for an un­controlled environment. This equipment should be installed and operated with a mini­mum distance of 20 centimeters between the radiator and your body.
Page 6 of 6
Loading...