Alpha Omega Instruments 9510 Specifications

SERIES 9510
Carbon Dioxide Monitor
FEATURES BENEFITS
State-of-the Art Sensor Technology. High Precision Measurement.
Audible / Visual Alarm Indicators. Personnel Alerted Quickly of an Alarm Condition.
Three Adjustable Alarm Relays. Easy Set CO2 Threshold Values.
Rapid Speed of Response. Senses Changes in CO2 in Seconds.
Audible & Visual Alarm Indication. Alerts User of Abnormal Operating Conditions.
Optional RS-232 or 485. Interfaces with Serial Communication Equipment.
Minimum Maintenance. Low Cost of Ownership.
No Sample Pump Required. Higher Reliability with Better Level of Protection.
Factory Calibrated. Ensures Accurate Readings from the Start.
System Description
The Series 9510 Carbon Dioxide Safety Monitor is designed to provide continuous, unattended measurement of parts per million (PPM) concentrations of carbon dioxide in breathing air environments. The Series 9510 features an open sen­sor diffuser that allows free movement of ambient air to the sensor without the use of a sample pump. For monitors that require a sample pump to transport the sample, often the re­liability of the measurement is contingent on the pump work­ing properly which may not always be the case.
The focal point of the Series 9510 is its state-of-the-art sen­sor technology. Alpha Omega Instruments carbon dioxide sensor features a next generation NDIR (non-dispersive in­frared) measuring system. The carbon dioxide sensor incor­porates closed-loop control for enhanced long-term calibra­tion stability. The control signal is generated by means of an optical referencing element that monitors source intensity.
Specications
PERFORMANCE
Measurement Range: 0-5,000 Parts Per Million (PPM)
Measurement Error: ± 50 PPM CO2 or ± 2% of reading (whichever is greater)
Response Time: < 35 seconds to a 63% of step change
Sensor Type: Non-Dispersive Infrared
Gas Sampling Method: Diffusion
Warm-up Time: Less than one minute
Operating Temperature: 50-104 F (10-40 C)
Calibration: Single gas calibration
Calibration Interval: Once every two years
This methodology, coupled with a novel source homogeniz­ing gas sampling chamber, yields a system with greatly im­proved tolerance to changes in the infrared source outputs.
Options/Accessories
Battery Backup Operation
RS-232 OR RS-485
Built-in Datalogger
Applications
Food Processing
Pharmaceutical Monitoring
R&D
Greenhouse Monitoring
HVAC
ELECTRICAL
Display: 3-1/2 digit liquid crystal display
Power Source: 115/230 VAC/50-60 Hz or 18-32 VDC
(Battery Backup Options available with AC power sources)
Analog Output: 4-20 mADC and 0-2 VDC
Optional Serial RS-232C or RS-485
Communications:
Alarm Relays: Three (3) SPDT Form C contacts rated
10A @ 30VDC / 115/230 VAC
Audible and
Visual Alarm Indicators: Standard
CONSTRUCTION
Enclosure: Polycarbonate-rated NEMA 1
Dimensions: 10.9 in. (276.86 mm) Height
6.5 in. (165.10 mm) Width
6.0 in. (152.40 mm) Depth
Weight:  7.5lbs.(3.402kg)(Bench-topCongurationorWallMount)