SERIES 9510
Carbon Dioxide Monitor
FEATURES BENEFITS
State-of-the Art Sensor Technology. High Precision Measurement.
Audible / Visual Alarm Indicators. Personnel Alerted Quickly of an Alarm Condition.
Three Adjustable Alarm Relays. Easy Set CO2 Threshold Values.
Rapid Speed of Response. Senses Changes in CO2 in Seconds.
Audible & Visual Alarm Indication. Alerts User of Abnormal Operating Conditions.
Optional RS-232 or 485. Interfaces with Serial Communication Equipment.
Minimum Maintenance. Low Cost of Ownership.
No Sample Pump Required. Higher Reliability with Better Level of Protection.
Factory Calibrated. Ensures Accurate Readings from the Start.

System Description
The Series 9510 Carbon Dioxide Safety Monitor is designed
to provide continuous, unattended measurement of parts per
million (PPM) concentrations of carbon dioxide in breathing
air environments. The Series 9510 features an open sensor diffuser that allows free movement of ambient air to the
sensor without the use of a sample pump. For monitors that
require a sample pump to transport the sample, often the reliability of the measurement is contingent on the pump working properly which may not always be the case.
The focal point of the Series 9510 is its state-of-the-art sensor technology. Alpha Omega Instruments carbon dioxide
sensor features a next generation NDIR (non-dispersive infrared) measuring system. The carbon dioxide sensor incorporates closed-loop control for enhanced long-term calibration stability. The control signal is generated by means of an
optical referencing element that monitors source intensity.
Specications
PERFORMANCE
Measurement Range: 0-5,000 Parts Per Million (PPM)
Measurement Error: ± 50 PPM CO2 or ± 2% of reading (whichever is greater)
Response Time: < 35 seconds to a 63% of step change
Sensor Type: Non-Dispersive Infrared
Gas Sampling Method: Diffusion
Warm-up Time: Less than one minute
Operating Temperature: 50-104 F (10-40 C)
Calibration: Single gas calibration
Calibration Interval: Once every two years
This methodology, coupled with a novel source homogenizing gas sampling chamber, yields a system with greatly improved tolerance to changes in the infrared source outputs.
Options/Accessories
Battery Backup Operation
RS-232 OR RS-485
Built-in Datalogger
Applications
Food Processing
Pharmaceutical Monitoring
R&D
Greenhouse Monitoring
HVAC
ELECTRICAL
Display: 3-1/2 digit liquid crystal display
Power Source: 115/230 VAC/50-60 Hz or 18-32 VDC
(Battery Backup Options available with AC power sources)
Analog Output: 4-20 mADC and 0-2 VDC
Optional Serial RS-232C or RS-485
Communications:
Alarm Relays: Three (3) SPDT Form C contacts rated
10A @ 30VDC / 115/230 VAC
Audible and
Visual Alarm Indicators: Standard
CONSTRUCTION
Enclosure: Polycarbonate-rated NEMA 1
Dimensions: 10.9 in. (276.86 mm) Height
6.5 in. (165.10 mm) Width
6.0 in. (152.40 mm) Depth
Weight: 7.5lbs.(3.402kg)(Bench-topCongurationorWallMount)
40 Albion Road, Suite 100, Lincoln, RI 02865
Tel: 401.333.8580, 800.262.5977 Fax: 401.333.5550
Email: salescontact@aoi-corp.com Web: aoi-corp.com