
SERIES 3000
Trace Oxygen Analyzer
Product shown with optional ow meter and coalescing lter
FEATURES
Long-life Trace
Oxygen Sensor
Sealed Sensor
CO2 Resistant Sensor
Economically priced
Wide Measurement
Ranges
Factory Calibration
Visual and Audible Alarms
BENEFITS
Provides up to three times the functional life of most “fuel cell” type
sensors. Reliability is dramatically increased while maintenance costs
are reduced.
Eliminates handling potassium hydroxide (caustic), a hazardous material or having to frequently “recharge” the electrolyte.
Optional CO2 resistant sensor is designed to operate with sample gases
containing up to 100% CO2. Conventional “fuel cell” type sensors using
KOH electrolyte can be poisoned from CO2.
Affords savings of up to 50% over other manufacturers trace oxygen
analyzers.
Measure from under 1 PPM to as high as 10,000 PPM oxygen.
Factory calibration included at no additional charge. Upon request,
NIST calibration certicates available
Ensures the highest level of protection and reliability.

Product Description
The eloquence of the Series 3000 Trace Oxygen Analyzer is its ease of use.
The Series 3000 is a microprocessor- controlled instrument that is available in either a single range or three range conguration. Measurement
ranges are from 0-1 PPM to 0-10,000 PPM. For three range analyzers,
auto-ranging is included at no additional charge. The analyzer is housed
in a general purpose enclosure and is powered from either 115/230 VAC,
50-60Hz, or 18-32 VDC. Battery power is an option. Trace oxygen values
are displayed on a 0.4 inch (10.2 mm) high, 4-1/2 digit liquid crystal display
(LCD). The long-life trace oxygen sensor is installed in a high integrity-leak
tested metal housing that is equipped with 1/4” stainless steel compression
ttings on both the sample gas inlet and outlet. Also included are manual
isolation valves. The Series 3000 can be congured with an optional remote sensor that may be placed up to 1,000 feet (approx. 300 meters)
from the electronics. Available in a wide number of optional mechanical
congurations from explosion proof (NEMA 7) to watertight (NEMA 4), the
Series 3000 Trace Oxygen Analyzer affords maximum exibility to meet the
increasing demands of the industrial, commercial, and educational markets.
Depending the application, the Series 3000 can be equipped with a number of options including; battery operation, sample lters, sample pumps,
pressure regulators, data logger, block & bleed by-pass sampling systems,
serial communications, sensor heaters, solenoid valves with internal control
connections, ow meters, etc.
High Performance Trace Oxygen Sensor
The Series 3000 Trace Oxygen Analyzer features Alpha Omega Instrument’s long-life ambient temperature electrochemical sensor that has a
functional life of up to three times that of most “fuel cell” type sensors. The
enhanced mechanical design of the sensor ensures longer life, and virtually
eliminates leakage of caustic electrolyte, a nagging (and expensive) problem associated with sensors that require periodic electrolyte maintenance.
Specications
PERFORMANCE
Measurement Ranges (parts per million)
Single-range Three-range
0-10,000 0-100/1,000/10,000
0- 5,000 0- 50/500/5,000
0-1,000 0-10/100/1,000
0-100 0- 5/50/500
0- 50 0-1/10/100
Accuracy¹: ±1% of full scale (±5% FS 0-1ppm range)
Linearity: ±1%
Response Time: 90% of full scale response in less than 10 seconds
(typical). The response time for ranges of 0-50 PPM or less depend to a
great extent on the design of the sample delivery system including the
materials used.
Sensor Type: Long-life Ambient Temperature Electrochemical
Sensor(Optional CO2 Resistant Sensor Available).
Temperature Standard
Compensation:
Operating 40° to 104° F (5° to 40° C)
Temperature <40° F (5° C) use heated sensor enclosure
(both sensor >104° F (40°) cooling of sample gas/ sensor
and electronics): required
Warranty: 2 years electronics, 1 year sensor
ELECTRICAL
Display: 0.4” (10.2 mm) high, 4-1/2 digit LCD
Resolution of 0.1 ppm for ranges <100 ppm
Display: 1.0 ppm for ranges >100 ppm
Input Power: 115/230 VAC, 50-60Hz or 18-32 VDC. Optional
battery backup available
.
Outputs: 4-20 mADC and 0-2 VDC standard as is a TTL
output for range identication. RS-232C or RS-
485 serial communication optional.
Oxygen Alarm Three (3) SPDT Form C contacts rated 10 A@
Relays: 30 VDC/115/230 VAC. User selectable for fail-
safe or non fail-safe.
And, because the sensor is sealed, it is not position sensitive. In addition,
unlike some electrochemical sensors, Alpha Omega Instruments readings
from the Series 3000 do not require manual adjustment based on changes
in the molecular weights of the sample gas i.e. helium, hydrogen, etc. a
major advantage for continuous measuring applications. The output from
the sensor is both linear and temperature compensated to provide optimum
performance.
Now Featured a CO2 Resistant Sensor
A nemesis for many conventional “fuel cell” type trace oxygen sensors are
their inability to measure oxygen in gases containing carbon dioxide. Carbon dioxide reacts with potassium hydroxide electrolyte to form carbonic
acid and in short time destroys the sensor. Not anymore. Alpha Omega
Instruments offers an optional CO2 tolerant trace oxygen sensor with proprietary electrolyte. The CO2 tolerant sensor is capable of providing accurate
oxygen readings in gases containing up to 100% CO2 without shortening
the life of the sensor.
The Series 3000 Trace Oxygen Analyzer is equipped with three oxygen
alarm relays and one status alarm relay. All four relays are Form C (SPDT)
types rated at 10 amps at 115/230 VAC and 30 VDC. The relays are user
congurable for fail-safe operation. In addition to the four alarm contacts,
the Series 3000 Trace Oxygen Analyzer has a built-in audible alarm and
three red LED’s for visual indication of an oxygen alarm condition. The
audible alarm may be manually canceled at any time. The Series 3000
provides two standard analog outputs, 4-20 mADC and 0-2 VDC. For enhanced communications, the Series 3000 Trace Oxygen Analyzer can also
be equipped with optional RS-232C or RS-485 serial communications.
The Series 3000 Trace Oxygen Analyzer is priced signicantly less than
most other manufacturers. Before making a purchase decision, we would
be delighted to discuss the Series 3000 Trace Oxygen Analyzer.
Instrument Rated identically to the O2 relays
Status Alarm:
Audible Alarm: Internal buzzer with audible cancel
SAMPLE GAS CHARACTERISTICS
Flow Rate: 1.0 to 2.0 SCFH (0.5 to 1.0 liter/min)
Sample Gas 40° to 104° F (5° to 40° C)
Temperature:
Sample Gas 0.1 to 1.5 psig (0.007 kg/cm² to 0.1 kg/cm²)
Pressure:
Entrained Solids: <3 mg/ft³: no in-line lter required
>3 mg/ft³: in-line lter is required
Hydrocarbon Mist: <0.7 mg/ft³: no in-line lter required
>0.7 mg/ft³: in-line lter is required
CONSTRUCTION²
Electronics Control Polycarbonate with a hinged clear front cover,
Unit (Bench-top rated NEMA 4X (IP 66)
without optional
equipment):
Control Unit 9.45 in. (240.5 mm) height
Dimensions: 6.50 in. (165.1 mm) width
6.20 inches (157.5 mm)
Note: All dimensions are without optional equipment
Gas Connections: 1/4” stainless steel compression ttings.
Sensor Mounting: Local or optional remote mounting
Weight: 11lbs (4.98 kg) (Standard Bench-top Conguration)
¹ Stated at constant temperature and constant pressure.
² Other mechanical congurations available-consult the factory.
³ Alpha Omega Instruments reserves the right to change or modify its
product specications without notice.
40 Albion Road, Suite 100, Lincoln, RI 02865
Tel: 401.333.8580, 800.262.5977 Fax: 401.333.5550
Email: salescontact@aoi-corp.com Web: aoi-corp.com
Alpha Omega Instruments Accepts VISA, Mastercard, and AMEX