Alpha XP-EDH3 User Manual

Page 1
Alpha XP-EDH3 Transponder
Field Installation Instructions
Effective: February 2009
Alpha Technologies
Page 2
Overview to the eld installation instructions
The XP-EDH3 transponder provides the ability to manage network power through an existing cable modem infrastructure, for a variety of power supplies as shown in this document.
These instructions provide information important to the successful installation, connection and operational verication of the Alpha XP-EDH3 transponder in a variety of systems.
Save these instructons for future reference.
CAUTION!
Use a surge protector in the cabinet when the transformer is used to measure line voltage. Do not place the transponder on top of the power supply or batteries. Make all battery harness connections and connect the interface cable to the power supply before connecting the cables to the transponder.
Before eld installation, the transponder's MAC address should be loaded into the CMTS, and DOCSIS conguration le options should be set.
Alpha XM, XM2 and AM Models
See Subsequent Sections for power supply-specic setup instructions
NOTE:
Alpha AM power supplies with RPM interface cards marked 700-019-28, 700-019-31 and 700-019-40 are compatible with the DOCSIS HMS Analog Transponder.
XM - USM
P1 = 2 & 3
P2, P4, P5, P6 = Closed
P3 = Open
P7 = 5V
P8, P9, P13 = 1 & 2
P14 = N/A
SW4 = 0
XM2 - USM2
SW1-1, 2, 6, 8 = On
SW2-1, 3, 4 = On
JP1 = C & 1
JP2 = 1 & 2
XM2 - USM2.5
SW1-1, 2, 6 = On
NOTE:
Output Current switch settings are determined by the output current capability of the power supply and should be setup accordingly. See your power supply user manual for setting details.
USM: N/A
USM2: SW1-3 = Output #1, SW1-4 = Output #2
USM2.5: SW1-3 = Output Current Scaling, 15A or 22A
RPM : No switch setting required
2
745-419-C3-001 Rev. A (02/2009)
Page 3
Connection Instructions for the Alpha AM, XM Series Power Supply
NOTE:
A chipset upgrade may be required; contact Alpha for more information. Set the jumpers and calibrate the USM card before making connections and applying the load.
1. Switch Battery Breaker OFF prior to removing the Inverter Module for USM Card installation and conguration.
WARNING!
When installing Battery Sense Cable Kit (BSC) or AlphaGuard sense cable, do not connect the black (negative) wire of the BSC to the negative post on Battery 1.
2. It is advisable to install the Battery or Aux pwr cables (providing power to the External DOCSIS unit) and waiting until the RDY LED is ashing normally before installing the power supply interface kit. This will reduce the chances of the power supply transferring to inverter due to a low signal reference on the test control pin.
Tamper switch
connection point
Pin 1
AM SERIES POWER SUPPLY CONNECTION
When connecting to an AM Series power supply, plug the 13-pin connector so the black wire is in pin1 and two open pins are left at the left for tamper switch connection (as viewed from the front
of the unit)..
Legend
1 Generator Interface (as needed) Alpha p/n 874-975-20
2, 5 Battery Sense Wire Kit for: 36V single string, 6', Alpha p/n 874-842-21
36V single string, 9', Alpha p/n 874-842-27
36V dual string, 6', Alpha p/n 874-842-20
36V dual string, 9', Alpha p/n 874-842-28
48V single string, 6', Alpha p/n 875-841-21
48V single string, 9' Alpha p/n 875-841-25
48V dual string, 6', Alpha p/n 875-841-20
48V dual string, 9', Alpha p/n 875-841-24
3 Ignition Battery/Aux Power Cable Alpha p/n 874-976-20
XM Series 2 Power Supply Interface Cable
XM Series Power Supply
4
Interface Cable
AM Series Power Supply Interface Cable
6 Craft Port Cable (optional) Alpha p/n 875-349-10
7 RTS Cable (optional) Alpha p/n 745-178-21
8 Vin Sense (optional) Alpha p/n 875-493-21
9 Surge Protector Ground Block Alpha p/n 162-028-10
Plug-in Lightning Arrestor w/pass thru
10
(130V) L-G, L-N, N-G
Alpha p/n 875-335-20 (USM2/2.5)
Alpha p/n: 875-335-21 (USM)
Alpha p/n: 875-335-21 (RPM)
Alpha p/n 162-046-10
Pin 1
Tamper switch
connection point
XM SERIES POWER SUPPLY CONNECTION
When connecting to an XM Series power supply, plug the 13-pin connector so the black wire is in pin1 and two open pins are left at the bottom for tamper switch connection (as viewed from the front of the unit).
2
1
9
10
8
4
7
3
6
5
745-419-C3-001 Rev. A (02/2009)
Connections between transponder, power supply and laptop
3
Page 4
Connection Instructions for the Alpha XM Series 2 Power Supply
WARNING!
The XM2 batteries are isolated from chassis ground by design. Any voltage potential difference between battery (-) and chassis ground must be eliminated before installing the transponder to avoid potential transponder damage. To accomplish this, attach a ground jumper between battery (-) and chassis ground before installing the transponder. Once the transponder is installed the jumper may be removed if desired.
Switch Battery Breaker OFF prior to removing the Inverter Module for USM2/USM2.5 Card installation and conguration.
Tamper switch
XM SerieS 2 Power SuPPly ConneCtion note:
When connecting to an XM Series 2 power supply, plug the 13-pin connector so the black wire is in pin1 and two open pins are left at the top for tamper switch connection.
connector
Pin 1
Legend
1 Generator Interface (as needed) Alpha p/n 874-975-20
2, 5 Battery Sense Wire Kit for: 36V single string, 6', Alpha p/n 874-842-21
36V single string, 9', Alpha p/n 874-842-27
36V dual string, 6', Alpha p/n 874-842-20
36V dual string, 9', Alpha p/n 874-842-28
48V single string, 6', Alpha p/n 875-841-21
48V single string, 9' Alpha p/n 875-841-25
48V dual string, 6', Alpha p/n 875-841-20
48V dual string, 9', Alpha p/n 875-841-24
3 Ignition Battery/Aux Power Cable Alpha p/n 874-976-20
XM Series 2 Power Supply Interface Cable
XM Series Power Supply
4
Interface Cable
AM Series Power Supply Interface Cable
6 Craft Port Cable (optional) Alpha p/n 875-349-10
7 RTS Cable (optional) Alpha p/n 745-178-21
8 Vin Sense (optional) Alpha p/n 875-493-21
9 Surge Protector Ground Block Alpha p/n 162-028-10
Plug-in Lightning Arrestor w/pass thru
10
(130V) L-G, L-N, N-G
Alpha p/n 875-335-20 (USM2/2.5)
Alpha p/n: 875-335-21 (USM)
Alpha p/n: 875-335-21 (RPM)
Alpha p/n 162-046-10
2
1
9
10
8
4
7
3
6
5
Connections between transponder, power supply and laptop
4
745-419-C3-001 Rev. A (02/2009)
Page 5
Input and Output Connections, ZTT and ZTT+ Models
SPI
ZTT/+
CAUTION!
Installation of the Vout and Iout sense harness requires powering down the power supply. Use an alternate source of power during this procedure.
7
1
6
4
9
5
8
2
2 3
745-419-C3-001 Rev. A (02/2009)
Connections between transponder, power supply and laptop
Legend
Power Supply Interface Alpha P/N: 875-335-22 (ZTT and ZTT+ Post 1998)
1
2 Battery Sense Wire Kit for: 36V single string, 6', Alpha p/n 874-842-21
3 Craft Port Cable (optional) Alpha p/n 875-349-10
4 RTS Cable (optional) Alpha p/n 745-178-21
5 Vin Sense (optional) Alpha p/n 875-493-21
6 Surge Protector Ground Block Alpha p/n 162-028-10
7 Vout Iout Sense Harness Alpha p/n 875-456-10
8 Tamper Wire Kit Alpha p/n 875-493-21
Plug-in Lightning Arrestor w/pass thru
9
(130V) L-G, L-N, N-G
Alpha P/N: 875-335-23 (ZTT+ Pre 1998)
36V single string, 9', Alpha p/n 874-842-27
36V dual string, 6', Alpha p/n 874-842-20
36V dual string, 9', Alpha p/n 874-842-28
48V single string, 6', Alpha p/n 875-841-21
48V single string, 9' Alpha p/n 875-841-25
48V dual string, 6', Alpha p/n 875-841-20
48V dual string, 9', Alpha p/n 875-841-24
Alpha p/n 162-046-10
5
Page 6
SPI
Input and Output Connections, Generic Models
CAUTION!
Installation of the Vout and Iout sense harness requires powering down the power supply. Use an alternate source of power during this procedure.
7
4
9
5
1
8
2
6
2
3
Connections between transponder, power supply and laptop
Legend
6
1 Power Supply Interface Alpha P/N: 875-335-25
2 Battery Sense Wire Kit for: 36V single string, 6', Alpha p/n 874-842-21
36V single string, 9', Alpha p/n 874-842-27
36V dual string, 6', Alpha p/n 874-842-20
36V dual string, 9', Alpha p/n 874-842-28
48V single string, 6', Alpha p/n 875-841-21
48V single string, 9' Alpha p/n 875-841-25
48V dual string, 6', Alpha p/n 875-841-20
48V dual string, 9', Alpha p/n 875-841-24
3 Craft Port Cable (optional) Alpha p/n 875-349-10
4 RTS Cable (optional) Alpha p/n 745-178-21
5 Vin Sense (optional) Alpha p/n 875-493-21
6 Surge Protector Ground Block Alpha p/n 162-028-10
7 Vout Iout Sense Harness Alpha p/n 875-456-10
8 Tamper Wire Kit Alpha p/n 875-493-21
Plug-in Lightning Arrestor w/pass thru
9
(130V) L-G, L-N, N-G
Alpha p/n 162-046-10
745-419-C3-001 Rev. A (02/2009)
Page 7
Verifying Installation and Network Connectivity (applies to all power supplies)
Method 1: Status LEDs
After the initial transponder power-up, network communication can be veried by the following behavior:
Rx LED on Solid, occasionally ickering off, indicating CMTS communication Tx LED off, but will icker when transmitting data to CMTS
Method 2: Local Port using Craft Port Cable, Alpha P/N: 875-349-10
Connect laptop to ‘Local’ port and set terminal emulator software settings to:
19200 Baud; 8-N-1; No Flow Control Type >STATUS for transponder IP Address Type >PSDATA 1 for power supply measurements
Method 3: Remote via HTTP Web Page
Place IP Address into Internet Web Browser to verify remote HTTP communication
Method 4: Remote via SNMP (Simple Network Management Protocol)
Use SNMP MIB Browser software to query power supply’s input voltage. [OID: 1.3.6.1.4.1.5591.1.4.2.1.23.1] A valid response veries remote SNMP communication.
745-419-C3-001 Rev. A (02/2009)
7
Page 8
Alpha Technologies
Power
®
Alpha Technologies
3767 Alpha Way Bellingham, WA 98226 USA Tel: +1 360 647 2360 Fax: +1 360 671 4936 Web: www.alpha.com
Alpha Technologies Ltd. 4084 McConnell Court Burnaby, BC, V5A 3N7 CANADA Tel: +1 604 430 1476 Fax: +1 604 430 8908
Alpha Technologies
Europe Ltd. Twyford House Thorley Bishop's Stortford Hertfordshire CM22 7PA UNITED KINGDOM Tel: +44 0 1279 501110 Fax: +44 1 279 659870
Alpha Technologies GmbH Hansastrasse 8 D 91126 Schwabach GERMANY Tel: +49 9122 79889 0 Fax: +49 9122 79889 21
Alphatec, Ltd 339 St. Andrews Street Suite 101 Andrea Chambers 3307 Limassol CYPRUS Tel: +357 25 375675 Fax: +357 25 359595
AlphaTEK ooo Khokhlovskiy Pereulok 16 Stroenie 1, Ofce 403 109028 Moscow RUSSIA Tel: +7 495 916 1854 Fax: +7 495 916 1349
Alphatec Baltic
S. Konarskio Street G.49-201 Vilnius LT-03123 LITHUANIA Tel: +370 5 210 5291 Fax: +370 5 210 5292
Alpha Technologies
34, Grande Rue Bétheny, F-51450
France
Phone: +33 32 64990 54 Fax: +33 67 54289 44
Copyright © 2009 Alpha Technologies, Inc. All rights reserved. Alpha is a registered trademark of Alpha Technologies. 745-419-C3-001, Rev. A.
Due to continuing product improvements, Alpha reserves the right to change specications without notice.
Loading...