Alpha TTVM4W User Manual

On this style of illuminated (lighted) buttons, connect the UPPER screwson the bulb assemblies to the 8-16VAC power from the system transformer. The LOWER screws are the actual button contact screws. DO NOT wire the UPPER screws
to the LOWER screws!
PLEASE NOTE: There are two (2) styles of illuminated (lighted) buttons used on the S.T.R.™ series lobby entry panel stations. Surface style panels usually have small bulb modules that actually snap onto the back of the call buttons, as shown in Fig. 1. Flush panels and larger capacity panels usually have larger (fuse style) bulbs actually mounted onto the flush back box, as shown in Fig. 2. Wire your panel as per one of the configurations shown above!
INSTALLATION GUIDELINES and GENERAL INFORMATION:
1. All low voltage wiring is #22 AWG, unless otherwise noted.
2. See actual system wiring diagram for balance of system wiring information.
4. All terminals connections shown may not be in the order that they appear on the equipment.
TYPICAL WIRING DIAGRAM FOR
S.T.R.™ style Lobby Entry Panels with
42 Central Drive, Farmingdale NY 11735-1202
(631) 777-5500 Fax: (631) 777-5599
TOLL-FREE Technical Line 1-800-666-4800
Email:info@alphacommunications.com
Copyright© 2000-2004, Alpha Communications®, All Rights Reserved
illuminated (lighted) call buttons.
AWD022 Rev. 2 (02/2004)