Alpha NC506ES Specsheet

Product Specification Sheet A PS777 - Rev. 07/2013
NC506ES Remote Receiver and 4 Relay Unit (TC500 Series)
42 Central Drive • Farmingdale • NY • 11735-1202 • Phone: (631) 777-5500 • Fax: (631) 777-5599
TOLL-FREE: (800) 666-4800 • Web: AlphaCommunications.com • Email: info@alphacommunications.com
Copyright© 1998-201 4 Alpha Communications® - All Rights Reserved.
Due to co ntinuous pro duct improvement, all colo rs, sizes, materials, finishes and specification s are subject to ch ange without n otice.
Architects' And Engineers' Specifications
The NC506ES shall provide remote annunciation of call activity within the Tek-CARE®500 (TC500) Wireless Emergency Call System.
It shall funct ion independently of the TC500 master station computer. It shall provide dry c ontact outputs which are Form-C and capable of driving a typical 24-volt dome lamp as used in the call systems. The NC506ES shall also allow t he use of an external, model TAK-4202 or T AK-4208 dialer, that accept s dry c ontac t input(s). The NC506ES shall also enable SF501ES, SF501/2ES and
SF502ES transmitters to t rigger t he external dialer.
All programming shall be non- volatile. The unit shall provide for easy connec tion of field wiring. Ac cess to the interior of the case shall be sec ured by a built-in tamper switc h - for easy connection to a t hird-party alarm syst em. The NC506ES shall be designed for indoor use only, and shall feat ure hidden cable connections and acc ess. The current st atus of all outputs shall be visually indicat ed on the fac e of the unit.
TekTone® has designed the Tek- CARE®500 (TC500) t o work as a system. Its NC501ES Master Stat ion Computer has been carefully designed and matc hed t o work with T C500 wireless and wired peripherals. TekTone® will not warrant or support c omponents of T C500 that are purchased separately unless the components are add-ons to previously sold syst ems. TekTone® will also not warrant or support a system that is a mix of TekTone® and Non­TekTone® parts, unless prior writt en permission has been obtained. In order to t rack our syst ems and to inform fac ilities of software upgrades, full site information (site name, address and phone number) will be required when ordering. Site information and
NC501ES warranty number will also be required when requesting
tec hnical support.
NC506ES Remote Receiver
The Alpha Communicat ions® / TekTone NC506ES is designed to allow users of t he Tek-CARE®500 (TC500) Wireless Emergency Call System to c onnec t external dome lamps and dialers to the system. This provides for an alternate annunciation path, in addition to t he normal T C500 screen. The NC506ES is not dependant upon the Tek-CARE®500's master station c omputer. It features 4 separate, dry-c ontac t outputs that can be programmed for activation by up to 4 transmitters.
The c ase has built-in tamper det ec tion outputs for c onnection to an external alarm system. All dry contact outputs are individually configurable for latc hing, follower or momentary ac tivation modes. The unit is designed for indoor use only, and cable access and connections are hidden. The fac e of the unit feat ures a c lean appearance with visual indication of the st atus.
The SF501ES and SF502ES transmitters c an be used with the
NC506ES to trigger an external dialer, but these momentary
transmitters do not support dome light annunciation.
Features
4 dry-c ontac t Form-C outputs Screw terminal connec tions Wiring access via hidden port Built-in tamper switc h LEDs display current stat us of transmitters Funct ions independently of Tek-CARE®500 Clean appearance for interior mounting
Specifications
Dimensions:
6.50"W X 3.50"H X 1.00"D (166mm X 89mm X 26mm)
Environment:
32°F–140°F, 0%–90% non-condensing relative humidity
Construction: Beige plastic outer casing
Connections: Barrier type sc rew t erminals
Mounting: Surface mount via 2 sc rews (included)
Power: 10-14VDC @ 50mA (supplied by PK505)
Required Components
PK505 Power Supply (1 per NC506ES required)