Product Specification Sheet A PS473 - Rev. 07/2013
NC351A / NC351A/2 Central Processing Equipment (CPE) (NC300II Series)
42 Central Drive • Farmingdale • NY • 11735-1202 • Phone: (631) 777-5500 • Fax: (631) 777-5599
TOLL-FREE: (800) 666-4800 • Web: AlphaCommunications.com • Email: info@alphacommunications.com
Copyright© 1998-201 5 Alpha Communications® - All Rights Reserved.
Due to co ntinuous pro duct improvement, all colo rs, sizes, materials, finishes and specification s are subject to ch ange without n otice.
Features
U.L. 1069 Listed, 4th Edition Standards
English Language Format
16 Paging Zones and All-Call
Programmable Alpha-Numerical Room Numbering
Programmable Bed Stat us
Master- to- Master Communications
Supervised Multiplexed Wiring - 32 Levels of Priority
Staff Locator and Follower
4 or 8 Simultaneous Talk Paths (depending upon CPE)
Master with SPILL-PROOF Membrane Switches
Modular c onstruction - easily expandable
2 isolated serial ports
Self-c ontained electronics and power supply
12 or 24 hour time display format
Buss connec tion for a single c ommon video out put
Architects' And Engineers' Specifications
The supplemental power supply shall be Alpha Communicat ions® /
TekTone PK305A or approved equal and will include t he nec essary
hardware to interface with the NC351A/2 Central Equipment to
provide additional power t o support up t o 512 patient stat ions.
The PK305A supplemental power supply shall be housed in a
durable metal enclosure with provisions for plug-in field wiring
connections.
The PK305A supplemental power supply shall be UL1069 Listed.
Contract or shall observe all local and national electrical and
building codes.
NC351A and NC351A/2 Central Processing Equipment
(CPE)
A major component of t he NC300II series microprocessor based
audio-visual nurse-call system, the Alpha Communicat ions®
NC351A and NC351A/2 CPE's supply the central equipment point
for syst em c omponent integration. The NC351A supports up t o 4
master consoles and 256 addressable stations, while t he NC351A/2
supports up to 8 mast er consoles and 512 addressable stations.
The NC351A and NC351A/2 house t he necessary firmware to
operate all the NC300II System funct ions. From a single durable
metal enclosure, the central equipment supports (2) isolated serial
ports, field st ation ports, master console ports, optional single
common video output, and power requirements for up to 512
patient, staff and duty stations.
Specifications
Dimensions:
19.50"W x 15.50"H x 5.25"D (496 x
394 x 134mm)
Capacity:
Up to 4 (NC351A) or 8 (NC351A/2)
masters and controllers, up t o 256
(NC351A) or 512 (NC351A/2) stations
Power Input: 115 V, 60 Hz, 125 W
Environment: 26°C; 0-80% relative humidity
Terminations: Plug-in connect ors
System Supervision:
Continuous polling of all stat ions.
Stat ion or wiring faults displayed at
master stat ion(s).
Audio:
Up to 4 (NC351A) or 8 (NC351A/2)
audio paths provided. Amplifiers rated
at 20 watt s. Overload and short
circuit protection included.
System Protection:
All outputs protect ed by selfresett ing current-limiting devices.
Required Components
PK305A Supplement al power supply. (1) Required for
each NC351A/2 CPE (not required for NC351A)