Alpha NC150N, NC150-16, NC150-12, NC150-08, NC150-04 Specsheet

Product Specification Sheet A PS080 - Rev. 01/2014
NC150N Audio-Visual Nurse-Call System - Desk/Wall Type
42 Central Drive • Farmingdale • NY • 11735-1202 • Phone: (631) 777-5500 • Fax: (631) 777-5599
TOLL-FREE: (800) 666-4800 • Web: AlphaCommunications.com • Email: info@alphacommunications.com
Copyright© 1998-201 4 Alpha Communications® - All Rights Reserved.
Due to co ntinuous pro duct improvement, all colo rs, sizes, materials, finishes and specification s are subject to ch ange without n otice.
Typical 56-Zone NC150N Master & OF202 Fra me
(shown without TA150N handset )
Architects' And Engineers' Specifications
The audio-visual nurse- call system shall be Alpha Communications® / TekTone NC150N series, or approved equal. At each of t he bed locations, c ontrac tor shall furnish and install a model IR151B (single) or IR152B (dual) bedside station and the required SF301/8 call-cords (or ot her specialty type cords as required). At eac h bath location, contractor shall furnish and install a model SF155B (pull/push) or SF337C (push/pull shower type) emergency-c all station. At each remote location, c ontractor shall furnish and install a model LI381 single bulb corridor dome light. Where required, c ontrac tor shall furnish and install the necessary double bulb LI382 corridor zone light(s), and/or model
IR150B staff stations and/or LI150B remot e duty stations.
At each main nurse's location, contractor shall furnish and install one (1) model NC150N/XXX (XXX=number of lamp indicators must be in multiples of 4) annunciator with appropriate backbox or housing (specify flush, surface or desk mounting). Annunciator shall have indicator lights no less than 5/8" by 5/8" in size, to allow for positive room rec ognition, when ac tivat ed. Eac h lamp module shall have a 'TEST' button t o allow for testing of all indicator lamps on t hat module, as oft en as desired. Each NC150N master stat ion shall have a built-in voice amplifier with internal volume cont rols.
System shall be U.L. listed 1069 to t he latest st andards.
Contract or shall observe all local and national electrical and building codes.
NC150N Series Audio-Visual Nurse-Call System
The Alpha Communicat ions® / TekTone NC150N series audio-visual nurse-call system is designed for health-c are applicat ions where voice communicat ion and visual indication is required. T he
NC150N system can support only a single master stat ion per
system.
When a remote station is activated, the NC150N annunciator will sound an electronic tone and will light, indicating t he locat ion of t he call. The t one signal can be silenced at the master stat ion (and/or at t he optional LI150B remote duty stat ion(s) for non- emergency calls). The individual switch/light will remain lighted until the remote station is reset at the point of origination, or when answered by voice from the master st ation (for remotes with voice capability only).
The NC150N master annunciator is modular and can be flush, surface or desk mounted, and is available in any size, in multiples of four (4) lights/switc hes. The NC150N features built- in tone signal, and t one silence button and light. 'TEST' buttons are used on eac h annunciator lamp module for lamp t esting. A press­to- talk butt on enables the NC150N master to speak with any voice type remot e st ation. Each NC150N mast er has a built- in amplifier with voic e volume c ontrols. An opt ional model T A150N handset module, can be installed onto any master st ation, for privat e voic e c ommunication, or for very noisy environments.
Features
Modular (NC150N) Mast er Stat ion available for any size application (in multiples of 4 lights/switches) Built-in Electronic Tone Signal and Tone Silence Switc h (Tone Silenc e Over-Ride for Emergency-Calls) Wide Variety of Remote Pullcords/Push-button St ations Ideal for Hospital and Nursing Home Applications - U.L. 1069 Listed Optional Remote Annunciators c an be provided Master(s) can be Flush, Surface or Desk Mounted
Typical Components
These components are required for a typical NC150N Master Station.
NC150N Master St ation module w/c ontrols & amplifier NC150/XX Master Station module with xx number of lamps AM150/XX Lamp selector add-on module(s)-- xx lamps OF20X Series Aluminum Frame for NC150N Master OH20X Series Flush Housing for NC150N Master
or IH200 Series Surface Housing for NC150N Master
or IH30X Series Desk Housing for NC150N Master
PK152 Annunciator power control unit SS106 Power transformer IH151N Junc tion Box - Surfac e Mount (required for UL) RP021CM Custom lens cap and lens marking PK153 Third priority c ontrol unit (optional)
Optional Component: T A150N Privacy Handset Module