Alpha DS100-04, DS100-04P, DS100-08, DS100-08P, DS100-12 Specsheet

...
Product Specification Sheet A PS040 - Rev. 01/2014
DS100 Series Latching Annunciator
42 Central Drive • Farmingdale • NY • 11735-1202 • Phone: (631) 777-5500 • Fax: (631) 777-5599
TOLL-FREE: (800) 666-4800 • Web: AlphaCommunications.com • Email: info@alphacommunications.com
Copyright© 1998-201 4 Alpha Communications® - All Rights Reserved.
Due to co ntinuous pro duct improvement, all colo rs, sizes, materials, finishes and specification s are subject to ch ange without n otice.
Model DS100/056 Shown
(50 Butto ns)
SF117/2A &
SF119/2A
SF154A IR019B
System Components
Power Supply: Model AC219 or PK2019A. One (1) required per DS100 master annunciator. Provides elect ronic tone signaling and form 'C' relay outputs. Requires model SS106 transformer. Frame: OF20X series annunciator frame. Use
OF201 for 1-gang, OF202 for 2-gang, etc.,
depending upon size of mast er annunciator. Housing: OH20X series (flush) or OH30X series (surface) or IH30X series (desk). Model depends upon size of OF20X series frame used. Tools Required: Model S1 Scrulox (Roberts head) sc rewdriver and model N553A lamp bulb extract or tool.
DS100 Series Latching Annunciator
The Alpha Communicat ions® / TekTone DS100 Door Sentry™ series latc hing annunciator is designed for alarm indications of an opening or a closing of a dry contact, or for other emergency-call/ panic t ype applicat ions.
When a remote contac t switch is activated, the DS100 annunciator will sound an elect ronic alarm (tone) and will light, indicating the locat ion of the alarm. The tone signal c an be silenced at the master station (and/or at the optional IR019B remot e alarm indicator). The individual switch/light will remain lighted until the remot e switch is reset, and the master switch is depressed twice, reset ting the light at the master annunciator.
The DS100 master annunc iator is modular and can be flush, surface or desk mounted, and is available in any size, in multiples of four (4) lights/switc hes. The
DS100 feat ures built- in tone signal speaker, and tone silence button and light.
NOTE: When using one or more CM800 Remote Annunciators, triggered from t he
DS100 Master Annunciator, please add t he Prefix "P" to each DS100 and AM100
module used for the Master Annunciator.
Features
Modular (DS100) Master Station available for any size application (in multiples of 4 lights/switc hes) Built-in Electronic Tone Signal and Tone Silence Switc h Wide Variety of Remote Pullcords/Push-button St ations Form 'C' Dry Contac t Relay output t o power remote devices Ideal for Elderly Housing and Emergency-Call Applications Individual selector switc hes c an be disabled (shunted) at t he master stat ion(s) Optional CM800 (non-latching) Remote Annunciators c an be provided Requires only 1-Common and 1- Select ive wire to each remot e c ontact switc h assembly
Architects' And Engineers' Specifications
The latching annunciator system shall be Alpha Communications® / TekTone®
DS100 series, or approved equal. At eac h of t he remote locat ions , c ontrac tor
shall furnish and install the required open OR closed c ircuit c ontac t switc h assembly.
At t he main sec urity location, contractor shall furnish and install one (1) model
DS100/XX (xx=number of lamp indicat ors-must be in multiples of 4) annunciator
console with appropriate backbox (spec ify flush, surfac e or desk mounting). Annunciator shall have indicator lights no less than 5/8" by 5/8" in size, t o allow for positive alarm recognition, when activated. Unit shall have model ST005D test button(s) t o allow for testing of all indicator lamps, as oft en as desired. Annunciator shall be latc hing type, and indicator lights will remain lighted until reset at t he master (once remote switc h has also been reset). Unit shall work on normally open OR normally closed switc hes, but all switches must be of the same activation/c onfiguration/type.
Contract or shall observe all local and national electrical and building codes.
Loading...