ALPHA AV113-12 Datasheet

Alpha Industries, Inc. [781] 935-5150 • Fax [617] 824-4579 Email sales@alphaind.com www.alphaind.com 1
Specifications subject to change without notice. 6/01A
HIP3™ Variable Attenuator
2.10–2.30 GHz
Features
Low Loss 1.4 dB Typical
Attenuation 18 dB Typical
Good VSWR <1.5:1 Typical
For IMT-2000 Applications
AV113-12
Description
The AV113-12 is a current controlled variable attenuator from Alpha’s series of HIP3™ components. It is designed to meet the wide dynamic range required in IMT-2000 applications. A monolithic quadrature hybrid is teamed with a silicon PIN diode pair in a plastic surface mount package reducing size and assuring consistency from part to part.
Parameter Min. Typ. Max. Unit
Frequency 2.1 2.3 GHz
Insertion Loss (0 mA Control Current) 1.4 1.6 dB
Attenuation @ 1.0 mA Control Current 16.5 18 dB
VSWR All Ports 1.5
Input 3rd Order Intercept Point 40 dBm
Group Delay 0.4 0.8 ns
Electrical Specifications at 25°C
Parameter
1
Condition Frequency Min. Typ. Max. Unit
Switching Characteristics
2
Rise, Fall (10/90% or 90/10% RF) 5 µs On, Off (50% CTL to 90/10% RF) 8 µs Video Feedthru (Peak) 2 mV
Maximum Input Power for <1 dB Attenuation Variation +15 dBm
Operating Characteristics at 25°C (0, +5 V)
1. All measurements made in a 50 system, unless otherwise specified.
2. 0–4 mA square wave total control current.
SOIC-8
SOIC-8
2 Alpha Industries, Inc. [781] 935-5150 • Fax [617] 824-4579 Email sales@alphaind.com www.alphaind.com
Specifications subject to change without notice. 6/01A
HIP3™ Variable Attenuator 2.10–2.30 GHz AV113-12
Characteristic Value
RF Input Power 0.5 W CW, 4 W @ 12.5%
Duty Cycle
Control Current 50 mA per Diode
Operating Temperature -40 to +85°C
Storage Temperature -40 to +85°C
Maximum Reverse Diode Voltage -10 V
Electrostatic Discharge +125 V
Absolute Maximum Ratings
Note: Operating this device above any of these parameters may cause irreversible damage.
123 4
CONTROL CURRENT
GND
220 pF
RF In
GND
680
876 5
GND
220 pF
22 nH 22 nH
RF Out
CONTROL CURRENT
GND
Pin Out
Loss (dB)
Attenuation vs. Control Current
Current (mA)
-40
-35
-30
-25
-20
-15
-10
-5
0
0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0
1.7 GHz
2.1 GHz
2.5 GHz
Loss (dB)
Attenuation vs. Frequency
Frequency (GHz)
-40
-35
-30
-25
-20
-15
-10
-5
0
1.7 1.8
1.9 2.0 2.1 2.2 2.3 2.4 2.5
0 mA
0.5 mA
1.0 mA
1.5 mA
Return Loss (dB)
Input Return Loss vs. Current Control
Current (mA)
-40
-35
-30
-25
-20
-15
-10
-5
0
0 0.2
0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0
1.7 GHz
2.1 GHz
2.5 GHz
Return Loss (dB)
Output Return Loss vs. Current Control
Current (mA)
-40
-35
-30
-25
-20
-15
-10
-5
0
0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0
1.7 GHz
2.1 GHz
2.5 GHz
Typical Performance Data
Loading...