Alpha Industries, Inc. [781] 935-5150 • Fax [617] 824-4579 • Email sales@alphaind.com • www.alphaind.com 1
Specifications subject to change without notice. 3/99A
Parameter
1
Condition Frequency Min. Typ. Max. Unit
Switching Characteristics Rise, On (10/90% or 50% CTL to 90% RF) 1.0 µS
Fall, Off (90/10% RF or 50% CTL to 10% RF) 0.3 µS
Intermodulation Intercept Point (IIP3)3For Two-tone Input Power +0 dBm 0.9 GHz 10 dBm
Control Voltage (VC) 0.0 V
S
V
Supply Voltage (VS) 3V
Control Current (IC) 0.2 x V
C
mA
Supply Current (IS) 150 µA
GaAs IC 35 dB Voltage Variable Attenuator
Single Positive 3 V Control 0.5–2.5 GHz
Features
■ Single Positive +3 V Control Voltage
■ 35 dB Attenuation Range @ 0.9 GHz
■ Excellent Linearity Performance
SOIC-8
AV106-12
0.049
(1.24 mm)
0.016
(0.41 mm)
0.016 MAX.
(0.41 mm) x
45˚ CHAMFER
PIN 1
0.197 (5.00 mm)
0.189 (4.80 mm)
0.068
(1.73 mm) MAX.
0.010 (0.25 mm)
0.004 (0.10 mm)
0.010 (0.25 mm)
0.007 (0.17 mm)
0.158 (4.00 mm)
0.150 (3.80 mm)
8˚
MAX.
0.020 (0.51 mm) MAX.
0.244 (6.20 mm)
0.228 (5.80 mm)
0.050 (1.27 mm) BSC
PIN 8
PIN 1
INDICATOR
Description
The A V106-12 GaAs IC FET voltage variable attenuator
provides 35 dB attenuation range at 900 MHz controlled
by a single positive v oltage.The VVA has a linear transfer
curve of 12 dB/V slope, with input and output VSWR better
than 2:1 over all states.Its attenuation range at 1900 MHz
is 25 dB.It operates with supply v oltage of +3 V and control
voltage of 0 V to +3 V in a low cost SOIC-8 pac kage.The
RF ports require 25 pF DC blocking capacitors.
Parameter
1
Frequency Min. Typ. Max. Unit
Insertion Loss (VC = 0 V) 0.5–1.0 GHz 3.4 3.6 dB
1.0–2.0 GHz 3.5 3.8 dB
2.0–2.5 GHz 3.8 4.2 dB
Maximum Attenuation (VC= 3 V)
2
0.5–0.8 GHz 25 32 dB
0.8–1.0 GHz 34 37 dB
1.0–1.7 GHz 28 33 dB
1.7–2.0 GHz 25 30 dB
2.0–2.5 GHz 23 26 dB
VSWR (I/O)
3
0.5–2.5 GHz 1.8:1
Electrical Specifications at 25°C (VS= 3 V)
Operating Characteristics at 25°C (VS= 3 V)
1.All measurements made in a 50 Ω system, unless otherwise specified.
2.Maximum attenuation includes insertion loss.
3. For worst case state.
Preliminary
GaAs IC 35 dB Voltage Variable Attenuator Single Positive 3 V Control 0.5–2.5 GHz AV106-12
2 Alpha Industries, Inc.[781] 935-5150 • Fax [617] 824-4579 • Email sales@alphaind.com • www.alphaind.com
Specifications subject to change without notice. 3/99A
2.52.0
Frequency (GHz)
Insertion Loss vs. Frequency
Insertion Loss (dB)
0.5 1.0 1.5
-5.0
-4.5
-4.0
-3.5
-3.0
-2.5
-20.
-1.5
-1.0
-0.5
0.0
2.52.0 3.01.5
VC (V)
Attenuation vs. Control Voltage
Attenuation (dB)
0 0.5 1.0
-40
-35
-30
-25
-20
-15
-10
-5
0
2.502.00
Frequency (GHz)
Maximum Attenuation vs. Frequency
Maximum Attenuation (dB)
0.50 1.00 1.50
-40
-35
-30
-25
-20
-15
-10
-5
0
Typical Performance Data @ 0.9 GHz
(Unless Otherwise Specified)
VC (V)
VSWR vs. Control Voltage
VSWR
1.0
1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
1.9
2.0
Input
Output
2.52.0 3.01.50 0.5 1.0
2.0 2.5 3.01.5
VC (V)
Input IP3 vs. Control Voltage
IIP3 (dBm)
0 0.5 1.0
0
5
10
15
20
25
30
2.0 2.5 3.01.5
VC (V)
Attenuation vs. Control Voltage
Over Temperature
Insertion Loss (dB)
0 0.5 1.0
-5
-4
-3
-2
-1
0
1
2
3
4
5
25˚C
85˚C
70˚C
-20˚C
Attenuation Normalized to 25˚C