ALPHA AV103-12 Datasheet

Alpha Industries, Inc. [781] 935-5150 • Fax [617] 824-4579 Email sales@alphaind.com www.alphaind.com 1
Specifications subject to change without notice. 12/99A
Parameter
1
Condition Frequency Min. Typ. Max. Unit
Switching Characteristics Rise, On (10/90% or 50% CTL to 90% RF) 130 nS
Fall, Off (90/10% RF or 50% CTL to 10% RF) 60 nS
Intermodulation Intercept Point (IIP3)3For Two-tone Input Power 0 dBm 0.9 GHz 12 dBm
Control Voltage (VC) 0.0 V
S
V
Supply Voltage (VS) 5.0 V
Control Current (IC) 1.1 x V
C
mA
Supply Current (IS) 150 µA
GaAs IC 35 dB Voltage Variable Attenuator Single Positive Control 0.5–2.5 GHz
Features
Single Positive +5 V Control Voltage
35 dB Attenuation Range @ 0.9 GHz
Less Than ±1 dB Attenuation Change Over
Temperature
Excellent Linearity Performance
SOIC-8
AV103-12
0.049
(1.24 mm)
0.016
(0.41 mm)
0.016 MAX.
(0.41 mm) x
45˚ CHAMFER
PIN 1
0.197 (5.00 mm)
0.189 (4.80 mm)
0.068
(1.73 mm) MAX.
0.010 (0.25 mm)
0.004 (0.10 mm)
0.010 (0.25 mm)
0.007 (0.17 mm)
0.158 (4.00 mm)
0.150 (3.80 mm)
MAX.
0.020 (0.51 mm) MAX.
0.244 (6.20 mm)
0.228 (5.80 mm)
0.050 (1.27 mm) BSC
PIN 8
PIN 1
INDICATOR
Description
The AV103-12 GaAs IC FET voltage variable attenuator provides 35 dB attenuation range at 900 MHz controlled by a single positive voltage.The VVA has a linear transfer curve of 9 dB/V slope, with input and output VSWR better than 2.1:1 over all states. Its attenuation range at 1900 MHz is 33 dB. It operates with supply voltage of +5 V and control voltage of 0 V to +5 V in a low cost SOIC-8 package. The RF ports require 100 pF DC blocking capacitors.
Parameter
1
Frequency Min. Typ. Max. Unit
Insertion Loss (VC = 5 V) 0.5–1.0 GHz 2.5 2.7 dB
1.0–2.0 GHz 2.8 3.0 dB
2.0–2.5 GHz 3.2 3.4 dB
Maximum Attenuation (VC= 0 V)
2
0.5–0.8 GHz 28 32 dB
0.8–1.0 GHz 31 35 dB
1.0–1.7 GHz 30 34 dB
1.7–2.0 GHz 29 33 dB
2.0–2.5 GHz 28 32 dB
VSWR (I/O)
3
0.5–2.5 GHz 2.1:1
Electrical Specifications at 25°C (VS= 5 V)
Operating Characteristics at 25°C (VS= 5 V)
1. All measurements made in a 50 system, unless otherwise specified.
2. Maximum attenuation includes insertion loss.
3. For worst case state.
Preliminary
2 Alpha Industries, Inc. [781] 935-5150 Fax [617] 824-4579 Email sales@alphaind.com • www.alphaind.com
Specifications subject to change without notice. 12/99A
GaAs IC 35 dB Voltage Variable Attenuator Single Positive Control 0.5–2.5 GHz AV103-12
0
-1
-2
-3
-4
2.52.0
Frequency (GHz)
Insertion Loss vs. Frequency
Insertion Loss (dB)
-5
0.5 1.0 1.5
V
C
Attenuation vs. Control Voltage
20
15
10
5
0
0.5
25
30
35
40
Attenuation (dB)
3.0 3.5 4.0 4.5 5.01.5 2.0 2.51.00
Frequency (GHz)
Maximum Attenuation vs. Frequency
0
5
10
15
20
25
30
35
40
2.51.5 2.00.5 1.0
Attenuation (dB)
Typical Performance Data @ 0.9 GHz
(Unless Otherwise Specified)
V
C
VSWR vs. Control Voltage
2.0
2.2
2.4
0.5
1.8
1.6
1.4
1.2
1.0
VSWR
3.0 3.5 4.0 4.5 5.01.5 2.0 2.51.00
Input VSWR
Output VSWR
V
C
Input IP3 vs. Control Voltage
25
30
35
0.5
20
15
10
5
0
IIP3 (dBm)
3.0 3.5 4.0 4.5 5.01.5 2.0 2.51.00
V
C
Attenuation vs. Control Voltage
Over Temperature
1
2
3
0.5
0
-1
-2
-3
Attenuation (dB)
3.0 3.5 4.0 4.5 5.01.5 2.0 2.51.00
+70˚C
+85˚C
-20˚C
Attenuation Normalized to 25˚C
Loading...