Alpha AC153 Specsheet

Product Specification Sheet APS1005 - Rev. 01/2017
AC153 3rd Priority Annunciator Control Unit (AlphaLinQ™ 100 series)AC153 3rd Priority Annunciator Control Unit (AlphaLinQ™ 100 series)
387 CANAL STREET • NEW YORK • NY • 10013-1615 • Phone: 212-431-5066 • Fax: 212-431-5422387 CANAL STREET • NEW YORK • NY • 10013-1615 • Phone: 212-431-5066 • Fax: 212-431-5422
Web: www.canalalarm.comWeb: www.canalalarm.com
Copyright © 1998-2 017 Alpha Communication s® - All Righ ts Reserved.
Due to c ontinuo us product i mprovement, all col ors, sizes, materials, finishes and sp ecifications are subject to change witho ut not ice.
AC153 3rd Priority Annunciator Control UnitAC153 3rd Priority Annunciator Control Unit
The Alpha Communicat ions® AC153 3rd Priority Annunciator Control Unit is used to provide a third level of signaling priority, for applications suc h as fire/heat/smoke detection and/or code call capabilities with the AlphaLinQ™ 100 series visual nurse-c all system, but can be used and is bac kwards c ompatible with some older systems as well.
One AC153 is required per system, in addition to t he AC152 control unit(s). No additional transformer is required. The AC153 contains the electronic circuitry necessary t o detect the presenc e of 3rd priority c alls, and to generate audible and visual control signals. It provides rapidly pulsating voltages t o operate visual signaling devices.
The AC153 shall also feat ure a built-in Form 'C' dry contac t relay which will act ivate when 3rd priority system calls are placed.
The AC153 is U.L. 1069 listed, to the latest st andards.
FeaturesFeatures
U.L. Listed 1069 - to the latest standards Easily Installs Right on Finished Wall Surfac e or in Optional Junction Box (model# CEC152) Positive Sc rew T erminal Connectors Built-in Form 'C' Dry Contact Relay to activate external devices Provides 3rd level of signaling priority (non-supervised)
SpecificationsSpecifications
Dimensions:
Height: 3.75" (96mm) Width: 4.25" (108mm) Depth: 2.375" (61mm) from mounting surface
Construction:
Electronic components mounted on a printed circuit board and housed in a rugged plastic case
Connections:
Positive Sc rew T erminal Connectors. Unit should be surface mounted and installed within 50 feet of master station.
Temperature: 0-50 degrees C
Typical System ComponentsTypical System Components
CDL101LED Corridor Dome Light w/1 White LED CDL102LED Corridor Zone Light w/1 White and 1 Red LED VPS101 Single Visual Patient Stat ion VPS102 Double Visual Patient St ation VSS110 Visual Staff Stat ion EPS155 Emergency Pull/Push Station (Toilet) EPS156 Emergency Pull/Push Station (Code Call / Code Blue) EPS337 Emergency Pull/Push Station (Shower) EPS339 Emergency Push Station (Mushroom Head) VDS150 Duty Station
Loading...