Product Specification Sheet APS1005 - Rev. 01/2017
AC153 3rd Priority Annunciator Control Unit (AlphaLinQ™ 100 series)AC153 3rd Priority Annunciator Control Unit (AlphaLinQ™ 100 series)
387 CANAL STREET • NEW YORK • NY • 10013-1615 • Phone: 212-431-5066 • Fax: 212-431-5422387 CANAL STREET • NEW YORK • NY • 10013-1615 • Phone: 212-431-5066 • Fax: 212-431-5422
Web: www.canalalarm.comWeb: www.canalalarm.com
Copyright © 1998-2 017 Alpha Communication s® - All Righ ts Reserved.
Due to c ontinuo us product i mprovement, all col ors, sizes, materials, finishes and sp ecifications are subject to change witho ut not ice.
Architects' And Engineers' SpecificationsArchitects' And Engineers' Specifications
The 3rd Priority Annunciator Control Unit(s) shall be shall be Alpha
Communications® AlphaLinQ™ 100 series model AC153, or
approved equal. The AC153 shall provide the t hird level of signaling
priority. T he AC153 shall automatic ally override normal and
low level emergency calls.
The AC153 shall also feat ure a built-in Form 'C' dry contac t relay
which will act ivate when 3rd priority system calls are placed.
The AC153 shall be mountable right to the surface of the wall or in
the optional model CEC152 U.L.® Listed junct ion
box cabinet. The AC153 shall be UL® 1069 Listed to the latest
standards.
Contractor shall observe all local and national electrical and
building codes.
Required ComponentsRequired Components
AlphaLinQ™ 100 Annunciator unit and syst em components
AC152 Control Unit (req. SS106 Transformer)
CEC152 U.L.® Listed steel junction box cabinet, in a
painted Beige finish. Used t o house and protect t he
AC153 and its wiring c onnections.
AC153 3rd Priority Annunciator Control UnitAC153 3rd Priority Annunciator Control Unit
The Alpha Communicat ions® AC153 3rd Priority Annunciator
Control Unit is used to provide a third level of signaling priority, for
applications suc h as fire/heat/smoke detection and/or code call
capabilities with the AlphaLinQ™ 100 series visual nurse-c all
system, but can be used and is bac kwards c ompatible with some
older systems as well.
One AC153 is required per system, in addition to t he AC152 control
unit(s). No additional transformer is required. The AC153 contains
the electronic circuitry necessary t o detect the presenc e of 3rd
priority c alls, and to generate audible and visual control signals. It
provides rapidly pulsating voltages t o operate visual signaling
devices.
The AC153 shall also feat ure a built-in Form 'C' dry contac t relay
which will act ivate when 3rd priority system calls are placed.
The AC153 is U.L. 1069 listed, to the latest st andards.
FeaturesFeatures
U.L. Listed 1069 - to the latest standards
Easily Installs Right on Finished Wall Surfac e or in
Optional Junction Box (model# CEC152)
Positive Sc rew T erminal Connectors
Built-in Form 'C' Dry Contact Relay to activate external
devices
Provides 3rd level of signaling priority (non-supervised)
SpecificationsSpecifications
Dimensions:
Height: 3.75" (96mm)
Width: 4.25" (108mm)
Depth: 2.375" (61mm) from mounting surface
Construction:
Electronic components mounted on a printed
circuit board and housed in a rugged plastic
case
Connections:
Positive Sc rew T erminal Connectors. Unit should
be surface mounted and installed within 50 feet
of master station.
Temperature: 0-50 degrees C
Typical System ComponentsTypical System Components
CDL101LED Corridor Dome Light w/1 White LED
CDL102LED Corridor Zone Light w/1 White and 1 Red LED
VPS101 Single Visual Patient Stat ion
VPS102 Double Visual Patient St ation
VSS110 Visual Staff Stat ion
EPS155 Emergency Pull/Push Station (Toilet)
EPS156 Emergency Pull/Push Station (Code Call / Code Blue)
EPS337 Emergency Pull/Push Station (Shower)
EPS339 Emergency Push Station (Mushroom Head)
VDS150 Duty Station