Alpha 4201B-V, A-4204, A-4208, A-4212, A-4216 Specsheet

...
Product Specification Sheet APS477 - Rev. 07/2013
4200 Series Audio-Visual Area of Rescue Assistance System4200 Series Audio-Visual Area of Rescue Assistance System
4201B/V Standard Anti-
Vandal Remote Station
4201B/VM Mushroom
A-4204 4-Station
Master Station (shown)
4200 Series Audio-Visual Rescue Assistance Systems4200 Series Audio-Visual Rescue Assistance Systems
The Americans with Disabilities Ac t (ADA) now being enforced, requires a Rescue Assist ance Syst em in all newly construct ed multi-story c ommercial buildings and public accommodations to provide a means to request evacuation assistanc e in the event of an emergency. The ADA also applies to significant renovations or alterations of existing multi-story fac ilities.
The most effec tive solution is the Alpha Communications® / Cornell 4200 series audio-visual Rescue Assistanc e System, which signals the need for evac uation assistanc e. T he 4200 series includes voice communicat ion which is initiated by simply depressing the call stat ion button, which transmits t he signal to a master stat ion. A single pulse tone and a flashing light signals the c aller that the alarm has been received. The master st ation may then t alk to t he caller. The caller need not take any other act ion to communicat e with the master stat ion, which is an important feature when a caller is under stress in an emergency situation. For additional safet y, a live 'fault' lamp will signal at the central (master) stat ion, if the wiring has been faulted.
The 4200 series is designed to accommodate up t o 44 remot e locations for each master st ation. The smallest master stat ion is a 4-unit and the capacities increment in groups of 4 to a maximum of 44 (or more with c ustom- sized masters). Master and remot e st ations are made of rugged Stainless Steel and Anodized Aluminum. Master st ations emit a loud, c lear tone signal that commands an immediate response.
The master st ation operator, upon receiving a c all stat ion signal activates a Zone button t hat illuminates both a flashing Red LED and a Green 'voice' LED. By depressing and releasing the 'Talk' button, voice c ommunication is established for as long as required.
Upon completion, the appropriate zone butt on is depressed again; however the flashing Red LED continues. If more than one zone is signaling, the master station ac c epts the call(s) in the same manner. When the emergency is resolved, the master station operator pushes a Reset butt on and restores the entire syst em to stand- by st atus. In the event of a wiring fault, each annunciator button is equipped with a Y ellow LED that will illuminate, and an alarm will sound, identifying the zone requiring service.
The standard audio-visual (anti- vandal) remot e c all station is the model 4201B/V. The 4201B/V is designed for indoor or outdoor use. The 4201B/V features a metal call butt on, heavy duty speaker and tamper-resistant mounting screws, and is designed for indoor or outdoor use. The new model 4201B/VM is the same as t he 4201B/V except for a large Red Mushroom head call butt on. Both models fit neatly into a two gang elec trical box (or plaster ring).
Each mast er st ation is powered by a model# B-5243A power supply. The B-5243A power supply c ontains the bac k-up bat teries and batt ery c harger required or specified. Because of the critical nature of these systems, t he battery back up should be used only as temporary power until this syst em can be c onnec ted to the building's emergency generator, should there be one.
We also offer a c omplete line of Rescue Assistance Signage. This includes a series of batt ery powered room identification signs, brand new photoluminesc ent signs, as well as direction and location signs. These signs meet ADA specifications for use with Areas of Rescue Assistance. See our specification sheet APS478 for more information on t he signage available.
Architects' And Engineers' SpecificationsArchitects' And Engineers' Specifications
The Area of Refuge (Area of Rescue) system(s) shall be Alpha Communications® / Cornell 4200 audio-visual series or approved equal. It shall have push- button controlled circuits and LED indicator lights for c all funct ions.
At the master location, c ontrac tor shall furnish and install one (1) model A-42xx mast er annunciator (xx=number of zones from 4 to 44 in multiples of 4) with the appropriate flush backbox. Each A-4200 series master stat ion shall have one (1) alternate ac t ion switc h with internal LED indicat or for eac h zone, to allow for positive c all-in recognition, when act ivated, as well as a 'Talk'
System FeaturesSystem Features
ADA Compliant (in many states - check with you local AHJ's) Clear 2-Way (simplex) Voice Communication Hands-Free Voic e Reply from Remote Station(s) Supervised Choice of Standard or Anti-Vandal Remotes Choice of Indoor or Outdoor Remot es Battery Back-up (optional) Choice of Master Stat ions Choice of ADA Compliant Signage available Remotes mount into standard electrical boxes Simple to wire
387 CANAL STREET • NEW YORK • NY • 10013-1615 • Phone: 212-431-5066 • Fax: 212-431-5422387 CANAL STREET • NEW YORK • NY • 10013-1615 • Phone: 212-431-5066 • Fax: 212-431-5422
Web: www.canalalarm.comWeb: www.canalalarm.com
Copyright © 1998-2 017 Alpha Communication s® - All Righ ts Reserved.
Due to c ontinuo us product i mprovement, all col ors, sizes, materials, finishes and sp ecifications are subject to change witho ut not ice.
button. Each master st ation shall emit a minimum sound level of 90db at 30cm. A Y ellow LED light on the master will illuminate and the alarm will emit a repeating sound if any of t he supervised lines are faulted. Each master st ation shall be c onstructed of natural anodized aluminum, with permanently silk sc reened designations on the panel as well as a designation strip.
At each of t he remote call-in locations, contract or shall furnish and install a model 4201B/V (anti-vandal) indoor/outdoor remot e stat ion or model 4201B/VM remote station with large Red Mushroom head c all button, and its assoc iated flush electrical back box (or plaster ring). Remote(s) shall consist of one (1) momentary switch with LED, built-in speaker, and one (1) audible alarm device with a minimum sound level of 90db at 30cm. Remote shall have Call-Placed and Call Answered L.E.D. indicators.
Contractor shall furnish and install one (1) model# B-
5243A combination power supply and batt ery bac k-up unit, for
each master stat ion, complete with met al housing.
Contractor shall observe all local and national electrical and building codes (and A.D.A. regulations).
Principle of OperationPrinciple of Operation
Activity At Master At Remote
Standby Mode No Light/T one No Light/T one
Alarm Sent
Steady Red LED / Intermittent T one
Lighted Button / One Time Tone
Alarm Acknowledged / Activated
Flashing Red LED / Steady Green
Flashing Button / One Time Tone
Intercom ON
Push to Talk / Release to Listen
Hands-Free Communic at ion
Intercom OFF
Flashing Red LED / OFF Access Zone Button
Flashing Button
Wiring F ault
Yellow LED at Zone/Intermittent T one
Button will not light
Special NoteSpecial Note
Area of Resc ue systems are known by several names... these include Area of Resc ue Assistance, Area of Rescue, Area of Rescue Assistanc e, Area of Refuge, Area of Refuge Assistance. These names are basically interchangeable.
Wiring RequirementsWiring Requirements
From the mast er st ation t o eac h remote call station run a t hree (3) conductor #22AWG cable AND one (1) twist ed Shielded pair #22AWG cable. Eac h c able run should not exceed 3,000 feet (914 meters). From the master station to the power supply (B-5243A) run a two (2) conductor #18AWG cable. Cable need not be shielded. Power supply cable run should not exceed 500 feet (152 meters).
Master Station Models / SizesMaster Station Models / Sizes
Model Master Station Flush Backbox
A-4204
(4-zo ne)
11.0"H x 10.0"W BB- 40: 10.0"H x 9.0"W
A-4208
(8-zo ne)
11.0"H x 14.0"W BB- 41: 10.0"H x 13.0"W
A-4212
(12-zone)
11.0"H x 18.0"W BB- 42: 10.0"H x 17.0"W
A-4216
(16-zone)
20.0"H x 14.0"W BB- 43: 19.0"H x 13.0"W
A-4220
(20-zone)
20.0"H x 14.0"W BB- 43: 19.0"H x 13.0"W
A-4224
(24-zone)
20.0"H x 18.0"W BB- 44: 19.0"H x 17.0"W
A-4228
(28-zone)
20.0"H x 18.0"W BB- 44: 19.0"H x 17.0"W
A-4232
(32-zone)
20.0"H x 22.0"W BB- 45: 19.0"H x 21.0"W
A-4236
(36-zone)
20.0"H x 22.0"W BB- 45: 19.0"H x 21.0"W
A-4240
(40-zone)
20.0"H x 26.0"W BB- 46: 19.0"H x 25.0"W
A-4244
(44-zone)
20.0"H x 26.0"W BB- 46: 19.0"H x 25.0"W