Alpha 240 Range, 280 Range Instruction

Supplementary LPG Boiler
Instructions
Alpha 240/280 Range
Wall Mounted, Fan Assisted, Room Sealed, Gas Fired
Combination Boiler
For Technical help or for Service call ...
ALPHA HELPLINE
Tel: 0870 3001964
0051
Wrotham Heath, Sevenoaks,
Kent TN15 7RS
For use with LPG (Propane) only
Leave these instructions with the User
1 INTRODUCTION
This supplement is for the LPG model of the boiler; it must be read in conjunction with the 'Installation and Servicing Instructions' supplied with the boiler and provides the extra information which is particular to LPG.
The Alpha 240/280 range of boilers are wall mounted, fan assisted room-sealed combination boilers. Heat output is controlled by a modulating gas valve.
The boiler, providing both central heating and domestic hot water at mains pressure, is designed for use with a fully pumped, sealed and pressurised heating system using only PROPANE gas.
2 TECHNICAL DATA
2.1 PERFORMANCE (Alpha 240 Range) - PROPANE GAS
Central Heating
Heat Input kW (Gross) Btu/h Heat Output (modulating) kW
Btu/h
Burner Pressure mbar Settings in wg
Room sealed chamber panel fitted
Gas Supply Pressure (LPG) mbar
in wg
Gas Rate m³/h
ft³/h
CH Water Temp. (Approx. max.) °C
°F
MAX.
28.63
97 700
23.3
79 500
36.6
14.6
1.1
39.1
MIN.
11.76
40 150
9.3
31 700
6.2
2.84
37.0
14.8
0.45
16.1
82
180
2.2 PERFORMANCE (Alpha 280) - PROPANE GAS
Central Heating
Heat Input kW (Gross) Btu/h Heat Output (modulating) kW
Btu/h
Burner Pressure mbar Settings in wg
Room sealed chamber panel fitted
Gas Supply Pressure (LPG) mbar
in wg
Gas Rate m³/h
ft³/h
CH Water Temp. (Approx. max.) °C
°F
MAX.
34.5
117 700
28.0
95 500
35.0
14.0
1.3
47.1
MIN.
11.76
40 150
9.3
31 700
4.0
1.6
37.0
14.8
0.45
16.1
82
180
Domestic Hot Water
Heat Input kW (Gross) Btu/h Output to Water (modulating) kW
Btu/h
Burner Pressure mbar Settings in wg
Room sealed chamber panel fitted
Gas Supply Pressure (LPG) mbar
in wg
Gas Rate m³/h
ft³/h
Flow Rate at 35°C Rise L/min
G.P.M.
Outlet Water Temp. (Approx. max.) °C
°F
Domestic Hot Water
Heat Input kW (Gross) Btu/h Output to Water (modulating) kW
Btu/h
Burner Pressure mbar Settings in wg
Room sealed chamber panel fitted
Gas Supply Pressure (LPG) mbar
in wg
Gas Rate m³/h
ft³/h
Flow Rate at 35°C Rise L/min
G.P.M.
Outlet Water Temp. (Approx. max.) °C
°F
MAX.
28.63
97 700
23.3
79 500
36.6
14.6
1.1
39.1
MAX.
34.5
117 700
28.0
95 5000
35.0
14.0
1.3
47.1
MIN.
11.76
40 150
9.3
31 700
6.2
2.84
37.0
14.8
0.45
16.1
9.5
2.1 62
144
MIN.
11.76
40 150
9.3
31 700
4.0
1.6
37.0
14.8
0.45
16.1
11.4
2.5 62
144
LPG Supplement
2