![](/html/46/4607/46076219908e67f2219df0fa2c25b8eea29734b2f7ddc1b05708069b687b9b09/bg1.png)
DEHUMIDIFIERS
Installation and Operations Manual
Registrate by scanning
ALO
R
A
I
R
AlorAir Dehumidifiers
E-mail: sales@alorair.c om
Add: Nor th C arolina USA
Armored 70L
![](/html/46/4607/46076219908e67f2219df0fa2c25b8eea29734b2f7ddc1b05708069b687b9b09/bg2.png)
※ ※Safety Notes
DEHUMIDIFIERS
The Series Dehumidifier must always be connected using a grounded
ALORAIR
electrical connection as required for all electrical appliances. The warranty is voided and all
responsibility for the operation transfers to the owner if non-grounded wiring is utilized.
ALORAIR
The Dehumidifiers must be maintained and serviced by qualified technicians.
The Dehumidifiers are intended for use only when the unit is installed in a
ALORAIR
level and upright position. Operating the unit in any other position could cause water to come
in contact with the electrical components.
Before moving the dehumidifier, turn off dehumidifier and allow pump to empty
reservoir. (Or if unit is already off, press “P” button to confirm drain reservoir is empty).
After the pump has finished operation, unplug the power cord and relocate unit to the desired
position.
If the inside of the unit has gotten wet for any reason, the unit should be opened and
allowed to dry thoroughly before reconnecting to electric and restarting.
For proper operation, neither the inlet or discharge should be positioned against a wall.
A minimum of 12” clearance between unit and any obstruction is required.
Do not insert any objects or fingers into the inlet or discharge.
All work on unit should be done with the unit “off” and unplugged.
Do not use water to clean unit exterior. Only use a damp cloth to clean exterior and
always unplug the unit first.
Do not use unit as shelf or device to hang clothes. This could cause damage to unit.
Do not stand on machine.
![](/html/46/4607/46076219908e67f2219df0fa2c25b8eea29734b2f7ddc1b05708069b687b9b09/bg3.png)
DEHUMIDIFIERS
DEHUMIDIFIERS
※ ※Table of Contents
Features/Specs.............................................................................................................................. 01
Identification................................................................................................................................. 01
How Your Armored Dehumidifier Works................................................................................ 02
Unit Overview................................................................................................................................ 03
Operating instructions................................................................................................................ 04
Preparing the Unit for Use.......................................................................................................... 10
Maintenance.................................................................................................................................. 11
Storing Your Dehumidifier.......................................................................................................... 12
Troubleshooting........................................................................................................................... 12
Warranty......................................................................................................................................... 17
※ ※Features/Specifications
The Armored Series dehumidifier operates based on the refrigerant principle of
dehumidification.
High Cop,3.0L/Kwh
Low Sound Levels <52dBA
Unit can be ducted, if necessary
Pump safety feature – overflow protection
Drain Pump with both Automatic and Manual Control
Automatic (Humidistat) or Manual Control
If power is interrupted during operation, the unit will automatically
restart when power is restored.
Eco-Friendly R410A Refrigerant
Self-monitoring system
Identification:
For future reference, write down the model, serial number, and date of purchase so you
can identify your unit when seeking assistance. NOTE: data label on back of unit includes
serial number.
Model Number Armored 70L
Serial Number__________________________
Date of Purchase__________________________
Customer Service:
For additional questions concerning the operation of your dehumidifier,
please:
Contact your installing contractor
Email: sales@alorair.com
-1-
![](/html/46/4607/46076219908e67f2219df0fa2c25b8eea29734b2f7ddc1b05708069b687b9b09/bg4.png)
DEHUMIDIFIERS
DEHUMIDIFIERS
How Your Armored Dehumidifier Works
The ALORAIR Armored Series Dehumidifier utilizes either its integral humidistat to
monitor the conditioned space or a manual on/off control to energize the compressor when
needed. Air is drawn across an evaporator coil. The evaporator coil is cooler than the dew
point of the air so water vapor will turn into liquid condensation. Air is then r eheated through
the condenser coil and distributed back into the room.
Installation:
WARNING!
1. Disconnect electrical power before servicing
2. Only plug unit into grounded electrical outlet
Power Supply: 220V, 50 Hz AC Only 1 Phase
Outlet Requirement: 3-Prong, GFI
Circuit Protector: 15 Amp Time Delay Fuse or Circuit Breaker
Alternatively, you can manually control unit to operate independent of space conditions.
Place unit in desired location. The inlet of unit should be at least 8”from any obstructions.
If unit is transported in the horizontal position, allow it to sit in upright position for at least 30
minutes before operating.
240 Volts AC may cause serious injury from electric shock.
3. Do not use extension cord
4. Do not use plug adapter
※ Front View
Front cover
Air Intake
Air iutlet
※ Rear View
※ Unit Overview ※
AL
O
RA
I
R
Handle
Door Latch
Wheel
WARNING!
It is recommended that the unit be removed from any location where corrosive or high
VOC content materials are applied.
-2-
Hose and
Cord Rack
Rear cover
Drain Tube
Connection
Control panel
Air Intake
Power Cord Input
-3-