Almost Heaven Saunas KIP-30-W1/FIN-30, KIP-45-W1/FIN-45, KIP-30-W3/FIN-30-3, KIP-45-B1/FLB-45, KIP-45-W3/FIN-45-3 Owner's/operator's Manual

...
14112012
MODEL MODEL MODEL
KIP-30-B1/FLB-30 KIP-30-W1/FIN-30 KIP-30-W3/FIN-30-3 KIP-45-B1/FLB-45 KIP-45-W1/FIN-45 KIP-45-W3/FIN-45-3 KIP-60-B1/FLB-60 KIP-60-W1/FIN-60 KIP-60-W3/FIN-60-3 KIP-80-B1/FLB-80 KIP-80-W1/FIN-80 KIP-80-W3/FIN-80-3
KIP-30-B3/FLB-30-3 KIP-45-B3/FLB-45-3 KIP-60-B3/FLB-60-3 KIP-80-B3/FLB-80-3
CONTROLS CONTACTORS
F-1T FL-402 F-2T FL-303 F-2
Sauna heater installation, wiring, operating instructions, trouble shooting, maintenance and guarantee.
IMPORTANT! This manual must be left with owner, manager or operator of Sauna after it is used by electrician!
Importer:
Almost Heaven Saunas HC66, 465-A Highway 219 North Renick, West Virginia 24966 304-497-3991
2
3
THE SAUNA ROOM SHALL BE PROVIDED WITH PROPER VENTILATION
INSTALLATION OF WALL MODEL HEATER, CONTROL, CONTACTOR
1. Remove heater from carton and attach heater to wall with screws are supplied. If wall thickness is less than 3/4”, use 2”x 4” backing behind heater. Observe proper clearances as per page 4 and table 1.
2. See applicable wiring diagram g. 5–8 for
heater model. Heater must be permanently installed (no pigtails or plug allowed) and wiring must be done by a licensed electrician, who must follow wiring diagram provided and adhere to local codes. Use proper A.W.G. rated wire size and use copper wire suitable for 90°C within Sauna walls. Use grounding terminals provided in Sauna heater, control system, and contactor to properly ground the equipment as per NEC and local codes.
3. See g. 5–8 to match control to heater model. Locate control in wall, 5’ up from oor, so that
panel faces outward from room. Punch out one of knockouts in roughin box and push rubber grommet (provided) into knockout hole. Bring capillary tubing
with sensing bulb out through grommet and through stud wall, so that capillary bulb is located 6’’ from ceiling inside Sauna room and as close to Sauna heater as possible, taking care to avoid sharp bends in tubing (to prevent damage to tubing and liquid within). Extra tubing can be coiled up inside wall. Nail or screw bulb guard to wall to secure sensing bulb.
4. Install contactor 4’’ up from oor behind Sauna
heater, on outside wall of Sauna room. Wire from contactor to heater must be within seal tight
exible conduit. (Contactor may also be located in
an equip. room or closet, but must be accessible, for servicing.
5. Inside the heater box there are two signs. Please place the metal ”CAUTION” sign on the interior wall of the Sauna room directly above the heater in a visible place. Place the metal ”WARNING” sign outside, on the door of the Sauna room. ”MAINTENANCE INSTRUCTIONS” are at the end of this manual.
Figure 1.
4
Figure 2.
Figure 3.
Figure 3a.
Figure 4.
THE SAUNA ROOM SHALL BE PROVIDED WITH PROPER VENTILATION WALL-MOUNTED HEATERS-MINIMUM CLEARANCES, MIN-MAX SPACE, ADEQUATE VENTILATION
MODEL INPUT
kW
MIN. HEIGHT
FLOOR AREA SAUNA
ROOM
MIN. SPACING FROM ADJACENT SURFACES, INCHES
Min. Sq.Ft
Max. Sq.Ft
Min. Cu.Ft
Max. Cu.Ft
KIP-30-B/W FLB/FIN-30
3.0 6’ 2” 10 20 84 130 3”
KIP-45-B/W FLB/FIN-45
4.5 6’ 2” 16 30 100 210 3”
KIP-60-B/W FLB/FIN-60
6.0 6’ 2” 28 40 170 300 4”
KIP-80-B/W FLB/FIN-80
8.0 6’ 2” 40 65 250 425 5”
Table 1.
5
Figure 5.
SAUNA HEATER (240 V) WITH BUILT IN CONTROLS
Model kW Amps Voltage Phase Wire size
KIP-30-B1 FLB-30
3.0 12.5 240 1 12
KIP-45-B1 FLB-45
4.5 18.8 240 1 10
KIP-60-B1 FLB-60
6.0 25.0 240 1 10
KIP-80-B1 FLB-80
8.0 33.3 240 1 8
SAUNA HEATER (208 V) WITH BUILT IN CONTROLS
Model kW Amps Voltage Phase Wire size
KIP-30-B3 FLB-30-3
3.0 8.3 208 3 14
KIP-45-B3 FLB-45-3
4.5 12.5 208 3 14
KIP-60-B3 FLB-60-3
6.0 16.7 208 3 12
KIP-80-B3 FLB-80-3
8.0 22.2 208 3 10
1 2
3
1 2 3
KIP-30-B1 / KIP-45-B1 / KIP-60-B1 / KIP-80-B1 FLB-30 / FLB-45 / FLB-60 / FLB-80
240 V 1 PHASE HEATER
HEATING
ELEMENTS
TIMER
CONTACTOR THERMOSTAT
LIMIT CONTROL
LINE 1
LINE 2 GND
GROUND
Internal wiring only
1 2
3
1 2 3
KIP-30-B3 / KIP-45-B3 / KIP-60-B3 / KIP-80-B3 FLB-30-3 / FLB-45-3 / FLB-60-3 / FLB-80-3
208 V 3 PHASE HEATER
HEATING
ELEMENTS
TIMER
CONTACTOR THERMOSTAT
LIMIT CONTROL
Internal wiring only
LINE 1 LINE 3
LINE 2 GND
GROUND