All Power APG3006 Owner’s Manual

1050WATTPORTABLE
GENERATOR
866.393,3968 866.393.3968
1050W4StrokeGenerator
Tableof Contents
1. DESCRIPTION
3. GENERAL SAFETY
4. OPERATION
PRE-OPERATION GROUNDING
DC APPLICATION STARTING ENGINE BREAK-IN
GENERATOR SHUT OFF LOAD AND PROTECTOR OIL WARNING SYSTEM
5, MAINTENANCE
INFREQUENT USAGE STORAGE- MAINTENANCE SCHEDULE
6, TROUBLESHOOTING
7. WIRING DIAGRAM
8. EXPLODED VIEW
9. PARTS LIST.
SPECIFICATION
TYPE
GENERATOR Voltage
ENGINE
UNIT Dimensions (L W H)
Max Power Rated Power Type Displacement Rated Power
Fuel Oil
Oil capacity Fuel tank capacity
Noise Net weight
2
2 2
3 3
4 4 4
5 5 5
5 6
6 6
7 8
9
10 11
Single-phase, brushless 120V
1050w 950kw 1-cylinder, 4-stroke, forced air cooling gasoline engine
80.7 cc
1.32kw/3600rpm Unleaded gasoline
SAE 10W-30
13.5 oz. 1A-gallons
17.3" 12.6" 16.1" <=65dB(A)
56 Ibs.
WARNING!READANDUNDERSTANDALLSAFETYPRECAUTIONSIN THISMANUALBEFOREOPERATING.FAILURETOCOMPLYWITH
INSTRUCTIONSIN THISMANUALCOULDRESULTIN PERSONAL INJURY,PROPERTYDAMAGE,AND/OR VOIDINGOFYOUR
WARRANT_[ALL POWERAMERICAWILLNOTBE LIABLEFORANY
DAMAGEBECAUSEOFFAILURETOFOLLOWTHESEINSTRUCTIONS.
1050W4StrokeGenerator
Description
This generator is powered by an air-cooled, four-stroke, OHV engine.
9 121314
When unpacking the generator, carefully inspect for any damage that may have occured during shipment. Make sure any loose fittings, bolts, etc., are tightened before putting unit into service.
1. Before starting or servicing any generator, read and understand all instructions. Failure to
follow safety precautions or instructions can cause equipment damage andlor serious
personal injury. Retain all manuals for future reference.
2. Never use this generator for any application other than that specified by the manufacturer.
Never operate this generator under conditions not approved by the manufacturer. Never
attempt to modify this generator to perform in any manner not intended by the manufacturer.
3. For maintenance and repairs, use only products and parts recommended by the manufacturer.
4. Be sure that the generator is properly grounded to an external ground path prior to operation. Refer to the section entitled
"Grounding Instructions" for proper grounding
procedures.
5. Be sure that the generator is operated only by persons who have read and understand these
instructions.
6. Be sure that the generator is placed on a flat level surface prior to and during operation. The
generator must not slide or shift during operation.
2
1
3
1. Fuel tank cap
2. Safty label
3.Control panel
4.Generator nameplate
5. Starting handle
6. Fuel petcock
7. Carburetor choke lever
8. DC circuit fuse
9. AC circuit fuse
10. AC output socket
11. DC output socket
12. Pilot lamp
13. Engine ignition switch
14.Oii warning indicator lamp
UNPACKING
GENERAL SAFETY
7. Keep all persons away from the generator during operation.
8. Do not allow persons wearing loose clothing or
jewelry to start or operate the generator. Loose
clothing or jewelry may become entangled in moving components causing equipment damage and/or personal injury.
9. While in operation, keep all persons away from the immediate area surrounding your generator.
IA WARNINOI
Do not operate this generator on wet surfaces or in the rain.
10. Be sure all powered devices are shut off prior to connecting them to the generator.
11. Keep the generator clean and well maintained at all times.
12. Be sure that all tools and appliances are in good repair and are properly grounded. Use
devices that have three prong power cords. If a extension cord is used, be sure that it has three prongs for proper grounding.
2
1050W4StrokeGenerator
Description
13. Never operate the generator with damaged, broken or missing parts. DO NOT operate the
generator while any of the protective shrouds or guards are removed.
14. Do not refill the fuel tank while the engine is running. Use precautions to prevent fuel spillage
during refills. Be sure the fuel tank cap is securely
in place before starting the engine. Allow engine to
coot for at least two minutes before refueling.
15. Be sure to store gasoline in clean containers
that do not contain water, dirt or rust because this wilI cause the engine to shut down.
l& WARN,NO]
Never operate this generator in an explosive
atmosphere, inside your home or basement, or any other poorly ventilated area.
I_ CAUTION I
Shut off the generator engine and disconnect the spark plug wire before performing any
service or maintenance to the unit.
OPERATION
PRE OPERATION
1. Check fuel level before starting your generator.
Always use clean, unleaded, mid-to-premium grade gasoline for best results. Do not overfill and allow some space at the top of the tank for expansion. We recommend that you use unleaded
fuel because it produces fewer engine and spark
plug deposits and extends the life of exhaust
system components. Using lower octane gasoline can cause persistent "pinging" or
heavy "spark knock" which, if severe, can lead
to engine damage. If "spark knock" or "pinging" occurs at a steady engine speed
under normal load, change brands of gasoline.
2. Check oil level before starting the engine. The
oil level should be positioned between the lower and upper marks of the oil fill cap shown.
UPPERLEVEL
I J_ CAUTION I
The generator is shipped from the factory without oil in the engine crankcase
Engine oil is a major factor affecting
engine performance and service life Detergent oils and vegetable oils are
not recommended
Use premium quality 4-stroke motor
oil Do not add commercial additives to the recommended oil and do not
mix gasoline with the oil
SAE 10W-30 is recommended for
general, all-temperature use
3. Only after the generator has stabilized and
is running smoothly should an appliance or tool be plugged into the AC outlet of the generator.
OIL FILLER CAP
(OIL GAUGE)
3