Allmand 6330, 8330, 6330.833 User Manual

Page 1
NIGHT-LITE
6330 AND 8330
OPERATOR’S MANUAL
ALLMAND BROS. INC
P.O. BOX 888
HOLDREGE, NE 68949
PHONE: 308/995-4495, 1-800/562-1373
ALLMAND FAX: 308/995-5887
NIGHT- LITE SERIES
For Parts and Updates visit Allmand on the Web at www.allmand.com
1
Page 2
INSPECTION CHECK LIST
FOR PREPARING THE NIGHT-LITE 6330 FOR DELIVERY OR RENTAL
The NIGHT-LITE 6330 requires service as well as proper operation in order to provide the performance and safety it has been designed for. Never deliver or put a machine into service with known defects or missing instructions or decals. Always instruct the customer in the proper operation and safety procedures as described in the operator’s manual. Always provide the manual with the equipment for proper and safe operation.
CHECK LIST:
Visually inspect the equipment to ensure that all instructions and decals are in place and
legible.
Inspect the tower latch and knob assembly which locks the tower in the vertical position for
proper operation
Check the hitch assembly and safety tow chainsCheck the outriggers and jacks to make sure they operate properlyInspect the light assemblies for damage and test for proper operationInspect the electrical wiring for signs of damageCheck the ground rod cable and the ground lug. Make sure they are clean, undamaged,
and functional.
Inspect the tires to ensure good condition and proper inflationCheck oil, fuel, coolant levels, and hydraulic fluid levels.Check to make sure the operator’s manual is with the equipment.Inspect the machine physically for damage and repair if necessary.
NOTE: See appropriate section of manual for scheduled maintenance intervals.
After completing the inspection check list, operate the tower through a complete operation cycle, following the operating instructions in the operator’s manual.
!
WARNING
NEVER ALLOW ANYONE TO OPERATE THE EQUIPMENT WITHOUT
PROPER TRAINING!
ALWAYS READ THE INSTRUCTIONS FIRST!
2
Page 3
TABLE OF CONTENTS
INSPECTION CHECK LIST ..................................................................................................... 2
TABLE OF CONTENTS ........................................................................................................... 3
INTRODUCTION ...................................................................................................................... 4
SAFETY SYMBOL INFORMATION .......................................................................................... 4
SAFETY AND WARNING DECALS ...................................................................................... 5-7
MANUAL WINCH MAST OPERATION .................................................................................. 8-9
ELECTRIC WINCH MAST OPERATION ............................................................................10-11
SPECIFICATIONS ............................................................................................................. 12-13
SERIAL NUMBER LOCATION ............................................................................................... 14
SPECIFICATIONS ............................................................................................................. 15-17
CONTROLS AND COMPONENTS ................................................................................... 18-25
ROUTINE MAINTENANCE SCHEDULE ............................................................................... 26
LISTER-PETTER LPW-3
ROUTINE MAINTENANCE SCHEDULE ............................................................................... 27
KUBOTA D905 D1105 AND PERKINS 103-10
TROUBLESHOOTING ........................................................................................................... 28
ASSEMBLY PARTS AND ACCESSORIES ........................................................................... 29
3
Page 4
INTRODUCTION
This manual provides the information necessary for the safe operation of the Allmand
Bros., Inc., NIGHT-LITE 6330 light tower.
The NIGHT-LITE 6330 standard tower configuration is operated by a two manual crank
winches or single electric winch used to erect, extend, and lower the tower.
Specific operating instructions and specifications are contained in this publication to
familiarize the operator and maintenance personnel with the correct and safe procedures necessary to maintain and operate the equipment.
Take time to read this book thoroughly. If you are uncertain about any of the information presented in the manual, contact the factory or your dealer for clarification before operation.
SAFETY SYMBOLS
The purpose of the SAFETY INFORMATION SYMBOL shown below is to attract your special attention to safety related information contained in the text.
!
DANGER
!
WARNING
!
CAUTION
FAILURE TO UNDERSTAND AND COMPLY WITH SAFETY RELATED INFORMATIONAL INSTRUCTIONS MAY RESULT IN INJURY TO OPERATOR OR OTHERS. IF YOU DO NOT UNDERSTAND ANY PART OF THIS INFORMATION CONTACT YOUR DEALER FOR CLARIFICATION PRIOR TO OPERATING EQUIPMENT.
NOTE
The word NOTE is used to bring your attention to supplementary information in relation to
various aspects of proper operation and maintenance.
NOTE: Keep this manual accessible during operation to provide convenient reference.
NOTE: Any reference in this manual to LEFT or RIGHT shall be determined by looking at
the trailer from the rear.
4
Page 5
!
SAFETY WARNING
SAFETY AND WARNING DECALS
ALWAYS REPLACE ANY SAFETY AND INSTRUC-
TION DECALS THAT BECOME DAMAGED, PAINTED,
OR OTHERWISE ILLEGIBLE.
PART NO. D-151 Location: Inside left hand door panel of Lister Petter engine units.
PART NO. D-249 Location: Inside left hand door panel of Kubota engine units.
Refer to these representations of the safety warning decals used on the MAXI-LITE to insure correct ordering if replacing be­comes necessary.
PART NO. D-264 Location: Inside left hand door panel.
5
Page 6
SAFETY AND WARNING DECALS
6
Page 7
SAFETY AND WARNING DECALS
7
Page 8
MANUAL WINCH MAST OPERATION
DESCRIPTION OF OPERATION
The Allmand NIGHT-LITE 6330 tower assembly consists of a three section tele­scoping mast which can be raised and extended by operating two hand crank winches. One winch, mounted with the handle extending through the side of the trailer frame, raises and lowers the mast from the horizontal towing position, the vertical position, and back. The second winch mounted on the tower extends the telescopic sections.
The three section mast assembly can be rotated from the ground by loosening a knob and rotating the entire assembly 360° to aim the lights as necessary.
!
SAFETY WARNING
ALWAYS CHECK FOR OVERHEAD
OBSTRUCTIONS BEFORE RAISING AND LOWERING MAST. ALLOW 35' CLEARANCE. AVOID ALL OVERHEAD ELECTRICAL WIRES.
TO PREVENT INSTABILITY AND HELP
ENSURE SAFE OPERATION, ALWAYS PROVIDE PROPER GROUND SUP­PORT BEFORE RAISING MAST.
BEFORE RAISING MAST, VISUALLY
INSPECT EQUIPMENT FOR DAMAGE OR WEAR. FAMILIARIZE YOURSELF WITH THE LOCATION AND FUNCTION OF ALL OPERATING PARTS BY STUDY­ING THIS MANUAL. OBSERVE ALL CAUTION DECALS LOCATED ON EQUIPMENT
NOTE: The latch locks the mast in the vertical position and disengages the sections allowing the tower assembly to be rotated to position the lights.
TO ERECT MAST AND RAISE LIGHTS
1. Extend both side outrigger jacks, rear jack and tongue jack to stabilize and level the trailer.
NOTE: Jacks should be placed only on firm footing.
!
SAFETY WARNING
WHEN EXTENDING REAR JACK, WATCH
TO ENSURE YOU ARE CLEAR OF THE OVERHANGING ENDS OF THE MAST BEFORE YOU STAND UP
THE SUPPLEMENTAL GROUND ROD IS A
SAFETY DEVICE THAT MAY REDUCE THE CHANCE OF PERSONAL INJURY FROM STRAY ELECTRICAL CURRENT
Therefore, Allmand recommends using the ground rod. However, it is the user’s responsibility to determine the require­ments and/or applicability of local, state, or national electrical code which governs the use of the ground rod.
2. Attach the ground rod to the grounding lug, and drive the ground rod fully for adequate electrical ground, as required by local, state, or national code.
3. Release the pin that secures the mast to the rear mast support.
4. Operate the hand crank on the side of the trailer to raise the mast from horizontal to vertical.
5. Turn black knob counterclockwise and engage latch in strike plate. Retighten black knob.
6. Operate the hand crank winch on the tower clockwise to raise the lights vertically.
7. To rotate the lights, release the black knob and turn the tower assembly with the handles provided.
8. To turn on lights, flip the breaker switches to the up position. (SEE FIG. 1)
.
.
8
Page 9
MANUAL WINCH MAST OPERATION
!
SAFETY WARNING
IF THE TOWER CANNOT BE ROTATED
AFTER LOOSENING THE BLACK KNOB, CHECK TO ASSURE THE LOWER LATCH IS ENGAGED IN THE STRIKE PLATE. THIS DOUBLE LATCH FEATURE PREVENTS THE TOWER FROM BEING ROTATED IF THE LATCH IS NOT EN­GAGED.
!
SAFETY WARNING
VISUALLY INSPECT EQUIPMENT FOR DAMAGE BEFORE OPERATING. ALLOW ADEQUATE CLEARANCE AROUND TRAILER FOR TOWER AND INSURE THAT NO PERSONS ARE STANDING IN FRONT OF OR BEHIND UNIT WHEN LOWERING.
TO LOWER MAST AND LIGHTS
1. Turn off lights.
2. Release black knob and rotate tower until winch handle points to the front of the trailer and retighten knob.
3. Operate hand crank winch on tower counter­clockwise to lower the lights to the lowest vertical position
4. Operate hand crank winch on side of trailer clockwise to take up any cable slack.
5. Turn the black knob counterclockwise and lift to release the latch from the strike plate. Re­tighten the knob with the latch disengaged from the strike plate.
6. Operate the hand crank on the side of the trailer counterclockwise to fold the mast down into the towing position
.
NOTE: Sufficient load (75 lb. min ) must be applied to the cable to overcome internal resistance and operate the brake properly. Insufficient load will not turn the reel thus continual turning without sufficient load will remove the winch handle from the shaft.
7. Secure light cords into hook on the rear tower support for towing.
8. Secure pin locking mast to rear tower support.
9. Remove ground rod from earth. Discon­nect wire from ground lug and secure in trailer
10. Raise jacks and rear stand, retract outriggers and secure for towing
NOTE: Ensure the detent pins are properly engaged in the outriggers before towing.
NOTE: Visually inspect the flood light mounting yokes for loose hardware. This could pre­vent a broken fixture during towing.
9
Page 10
STRONG ARM ELECTRIC WINCH MAST OPERATION
DESCRIPTION OF OPERATION
The Allmand NIGHT-LITE 6330 tower assem­bly consists of a three section telescoping mast which can be raised and extended by operating a single electric winch mounted inside the enclosure. A single three position toggle switch mounted on the control panel is used to raise and lower the mast. The winch and cable are protected by an integral clutch and a circuit breaker. The clutch is designed to slip when the mast reaches full extension. The circuit breaker is a safeguard for the clutch. If the clutch is misadjusted or inoperative the circuit breaker should trip to protect the system from overload. The electric winch operates off the 120 volt circuit breaker along with 120 volt receptacle thus requiring that the 120 volt
circuit breaker switch must be on to oper­ate the winch.
The three section mast assembly can be rotated from the ground by loosening a knob and rotating the entire assembly 360° to aim the lights as necessary.
!
SAFETY WARNING!
ALWAYS CHECK FOR OVERHEAD OB-
STRUCTIONS BEFORE RAISING AND LOWERING MAST. ALLOW 35' CLEAR­ANCE. AVOID ALL OVERHEAD ELECTRI­CAL WIRES.
TO PREVENT INSTABILITY AND HELP
ENSURE SAFE OPERATION, ALWAYS PROVIDE PROPER GROUND SUPPORT BEFORE RAISING MAST.
NOTE: The latch locks the mast in the vertical position and disengages the sections allowing the tower assembly to be rotated to position the lights
10
BEFORE RAISING MAST, VISUALLY INSPECT EQUIP­MENT FOR DAMAGE OR WEAR. FAMILIARIZE YOURSELF WITH THE LOCATION AND FUNCTION OF ALL OPERATING PARTS BY STUDYING THIS MANUAL. OBSERVE ALL CAUTION DECALS LO­CATED ON EQUIPMENT
TO ERECT MAST AND RAISE LIGHTS
1. Extend both side outrigger jacks, rear jack and tongue jack to stabilize and level the trailer.
NOTE: Jacks should be placed only on firm footing.
SAFETY WARNING
!
WHEN EXTENDING REAR JACK, WATCH
TO ENSURE YOU ARE CLEAR OF THE OVERHANGING ENDS OF THE MAST BEFORE YOU STAND UP
THE SUPPLEMENTAL GROUND ROD IS A
SAFETY DEVICE THAT MAY REDUCE THE CHANCE OF PERSONAL INJURY FROM STRAY ELECTRICAL CURRENT
Therefore, Allmand recommends using the ground rod. However, it is the user’s responsibility to determine the require­ments and/or applicability of local, state, or national electrical code which governs the use of the ground rod.
2. Attach the ground rod to the grounding lug, and drive the ground rod fully for adequate electrical ground, as required by local, state, or national code.
3. Release the pin that secures the mast to the rear mast support.
4. Operate the hand crank on the side of the trailer to raise the mast from horizontal to vertical.
5. Turn black knob counterclockwise and engage latch in strike plate. Retighten black knob.
6. Operate the hand crank winch on the tower clockwise to raise the lights vertically.
7. To rotate the lights, release the black knob and turn the tower assembly with the handles provided.
8. To turn on lights, flip the breaker switches to the up position. (SEE FIG. 1)
.
.
Page 11
STRONG ARM ELECTRIC WINCH MAST OPERATION
!
SAFETY WARNING
IF THE TOWER CANNOT BE ROTATED
AFTER LOOSENING THE BLACK KNOB, CHECK TO ASSURE THE LOWER LATCH IS ENGAGED IN THE STRIKE PLATE. THIS DOUBLE LATCH FEATURE PREVENTS THE TOWER FROM BEING ROTATED IF THE LATCH IS NOT EN­GAGED.
!
SAFETY WARNING
VISUALLY INSPECT EQUIPMENT FOR DAMAGE BEFORE OPERATING. ALLOW ADEQUATE CLEARANCE AROUND TRAILER FOR TOWER AND INSURE THAT NO PERSONS ARE STANDING IN FRONT OF OR BEHIND UNIT WHEN LOWERING.
TO LOWER MAST AND LIGHTS
1. Turn off lights.
2. Release black knob and rotate tower until winch handle points to the front of the trailer and retighten knob.
3. Operate hand crank winch on tower counter­clockwise to lower the lights to the lowest vertical position
4. Operate hand crank winch on side of trailer clockwise to take up any cable slack.
5. Turn the black knob counterclockwise and lift to release the latch from the strike plate. Re­tighten the knob with the latch disengaged from the strike plate.
6. Operate the hand crank on the side of the trailer counterclockwise to fold the mast down into the towing position
.
NOTE: Sufficient load (75 lb. min ) must be applied to the cable to overcome internal resistance and operate the brake properly. Insufficient load will not turn the reel thus continual turning without sufficient load will remove the winch handle from the shaft.
7. Secure light cords into hook on the rear tower support for towing.
8. Secure pin locking mast to rear tower support.
9. Remove ground rod from earth. Discon­nect wire from ground lug and secure in trailer
10. Raise jacks and rear stand, retract outriggers and secure for towing
NOTE: Ensure the detent pins are properly engaged in the outriggers before towing.
NOTE: Visually inspect the flood light mounting yokes for loose hardware. This could pre­vent a broken fixture during towing.
11
Page 12
SPECIFICATIONS
NOTE. In testing the Lister-Petter engine at the factory, the manufacturer uses an oil
for moderate and low temperatures. This oil is specially formulated to assist in the break in period, and we would like it to be left in the engine for the first 100 hours. Additional information on fuel and lubrication specifications is found in the Lister Petter Industrial Engine Operators Handbook.
See the KUBOTA 905 EBG1 or 1105 EBG1 Engine Operators Handbook or the
PERKINS 103-10 Engine Operators Handbook for information on oil and fuel requirements.
TOWING INSTRUCTIONS
Before towing the NIGHT-LITE 6330 the trailer should be inspected visually to insure that the following operations have been completed.
1. Hitch is securely attached to towing vehicle (safety chain secure).
2. All outriggers and jacks are retracted and secured.
3. Tower is lowered and the rear tower support pin is in place.
4. Light fixtures are positioned for transport.
5. Doors are closed and se­cure.
6. Check for adequate tire pressure.
7. Taillights are connected and operating (if equipped).
8. Ground rod is removed from ground and secured in the trailer
GROUND ROD INSTRUCTIONS
1. Remove ground rod stowed aside the left door (attached to the lower frame)
2. Unroll the electrical wire lead from the ground rod.
3. Attach the ground rod lead to the grounding lug located near the ballast compartment.
4. Drive the ground rod a minimum of 2 1/2 FT into the earth for adequate electrical grounding. If this is not possible consult your local qualified electrician.
5. AFTER SHUTDOWN OF ENGINE: Remove the ground rod from the earth, remove lead from the trailer ground lug and store ground rod inside left door.
12
Page 13
SPECIFICATIONS
BEFORE STARTING
1. Fill the engine with the right grade of lubricating oil (see pg. 19) and to correct level (check dipstick).
2. Ensure there is an adequate supply of fuel.
3. Ensure that the air cleaner is firmly attached, the air canister seals and the hose clamps are properly sealed. Air cleaner element should be checked and replaced if necessary.
4. Install the ground rod.
DESCRIPTION OF OPERATION
By depressing the start assist switch, the fuel solenoid is energized. The solenoid plunger is drawn into the coil and activates the fue! control linkage to RUN position. When the engine starts, adequate engine oil pressure at the oil pressure switch will maintain the solenoid in the energized position. The start assist switch can be released as soon as the engine starts. A 10A inline fuse protects the solenoid from electrical damage.
LOW OIL PRESSURE SHUTOFF SYSTEM
Should a low oil pressure condition occur (less than 5 PSI), the pressure sending unit breaks the circuit between the battery and the fuel solenoid, allowing the spring load to immediately move the fuel control to the shutoff position.
HIGH COOLANT TEMPERATURE SHUTOFF SYSTEM
Should a high coolant temperature condition occur, the temperature sending unit breaks the circuit between the battery and the fuel solenoid, allowing the spring load to immediately move the fuel control to the shutoff position.
STARTING/STOPPING INSTRUCTIONS
STARTING THE LISTER PETTER ENGINE
NOTE: LPW-3 Lister includes a glow plug and cold start system controlled by the start assist switch on the control panel. This switch also activates the fuel solenoid for quick starts. Use the switch routinely during engine starts.
NOTE: At temperatures below 30 F. depress the preheat switch for approximately one minute before going on to step 3.
3. Depress start switch until the engine fires. Release
start assist switch and start switch as soon as the engine starts.
NOTE: To prevent equipment damage, do not hold start switch in for more thon 10 seconds Allow cool down time between cranking inter-
vals.
STOPPING THE LISTER PETTER ENGINE
1.Turn ON/OFF toggle switch to the down (OFF) position.
STARTING THE KUBOTA AND PERKINS EN­GINES
NOTE: The Kubota and the Perkins engines includes a glow plug cold start system con­trolled by the ignition switch on the control panel. Glow plugs are not needed on a warm engine or if the ambient temperature is above 50 F. Do not use starting fluid or ether.
1. Turn the ignition switch to the PREHEAT posi- tion
and hold until the glow plug lamp goes out.
2. Turn the ignition switch to the Start position until the engine starts. Release key as soon as the engine starts.
3. If engine fails to start it may be necessary to cycle the glow plugs again.
NOTE: To prevent equipment damage, DO NOT hold ignition switch for more than 10 seconds in the start position. If the engine does not start in 10 seconds, wait 30 seconds and try the start sequence again. Do not run the cell motor for more than 20 seconds continuously. Limit engine cranking to 3 attempts with a 2 minute cooi-down between each. After 3 attempts allow to cool to ambient temperature.
STOPPING THE KUBOTA AND PERKINS EN­GINES
1. Turn ON/OFF toggle switch to the up (ON) position.
2. Depress preheat, start-assist switch engaging the fuel solenoid and powering the glow plug. Hold in until step 3 (next column) has been completed
1. Turn the ignition switch to the OFF position. This breaks the circuit between the battery and the fuel solenoid, allowing the spring load to imme­diately move the fuel control to the shutoff position.
2. Disconnect the ground rod.
13
Page 14
MODEL AND SERIAL NUMBERING SYSTEM
SERIAL NUMBER LOCATION
Trailer: All NIGHT-LITE 6330 models have a serial
number plate located just below the rear tower support on the rear panel.
Generator: Plate attached to the side of the generator housing.
Engine: Plate attached to the engine. LPW – 3 Top of intake manifold.
KUBOTA D905-BG and D1105-BG
Left side, between
manifold and starter.
ISUZU 3LB1 and PERKINS 103-10: Upper right front corner behind injector pump
DESCRIPTION OF MODELS AND OPTIONS
The NIGHT-LITE 6330 light tower uses four 1000 Watt Metal Halide lamps with the exclusive Allmand SHO lighting system to produce a total of 334,204 lumens (83,551 lumens per fixture). Optional reflective visors and 6-
light units are available. The lights are mounted on either a manual winch or electric winch tower. The manual tower is operated by two hand crank winches. One winch, mounted on the trailer frame, erects the mast from the horizontal towing position to vertical. The second winch, mounted on the tower, extends the mast vertically to the desired height. The second tower is operated by a 120V electric winch located inside the trailer housing. The electric winch erects the mast from horizontal to vertical and by releasing a lock handle extends the mast vertically to the desired height. The tower power cords are available as either straight cord or a cord reel. Inside fixture storage is offered for the 4-light option.
The heavy duty trailer shell has 12 gauge doors and roof panels. The shell houses the 15” wheels and tires inside the side panels. The front panels are rust proof ABS plastic. The NIGHT-LITE 6330 light tower is powered by either a Lister Petter LPW-3 16.5 hp water cooled engine, one of two Kubota water cooled engines,
10.5 hp or 13.6 hp., or an Isuzu water cooled 16 hp diesel engine. Each engine mounts to either the 6KW or 8KW generator. The trailer houses a 50 gallon poly fuel tank and an optional sound attenuation package.
14
Page 15
SPECIFICATIONS
ELECTRICAL
Hard wired electrical circuits Easily serviceable componentized ballast assemblies. Ground rod. Hour meter. Voltmeter (optional) External 120V and 240V outlets (optional).
FLOOD LIGHT ASSEMBLY
Four or six 1000 watt lamp fixtures sealed for all weather use. Lamps can be either the SHO 1000 fixture, 1250 watt fixture or PowerLite fixture.
SHO 1000 FIXTURE - BT-37 lamp, Metal Halide, Laboratory rated life is 10,000 hours.
Lumen rating: 110,000 Warm-up time: 2-4 minutes Restart time: 10-15 minutes
POWERLITE FIXTURE = BT=56 1000 watt Multi-Vapor lamp, Metal Halide, Laboratory rated life is 12,000 hours.
Lumen rating: 110,000 Warm-up time: 2-4 minutes Restart time: 10-15 minutes
POWERLITE FIXTURE - E-25 1000 watt High Pressure Sodium lamp (often referred to as H.P.S), Laboratory rated life is 24,000 hours.
NOTE: A trailer equipped with Metal Halide lights and a trailer equipped with High Pres- sure Sodium lights use different ballasts and starters. Therefore, it is not advisable to interchange bulb types.
MAST
Three-section steel tube mast, which extends to 30 feet. The mast is extended with either two manual winches or one Dutton-Lainson electric winch. The as­sembly includes self-lubricating nylon guide rollers and 360° rotating light bar.
TRAILER
The complete generator is housed in a lockable enclosure with the frame fabricated from heavy gauge steel mounted on a two­wheel, leaf spring axle. The design enables the trailer to contain the outriggers in a simple compact position.
When the mast is in the operating position it is located in the middle of a four point outrigger system for optimum balance and stability. This system was engineered to allow the light plant to remain operational in sustained winds of 65 MPH with the mast extended to full height and the outriggers in position. The design includes an adjustable-height re­versible hitch, which includes a 2” ball and pintle hook hitch.
Lumen rating: 140,000 Warm-up time: 4-6 minutes Restart time: 1 minute
STABILIZERS
Four (4) point outrigger design. with tower center mounted between two (2) retractable side outriggers, tongue and rear jack.
15
Page 16
NIGHT-LITE 6330 DIMENSIONS
Height lowered: 6’6" (1.98 m) Height extended: 30’ (9.14 m) Length: 14’9” (4.49 m) Width: 6’4”(1.92 m) Outrigger width: 11’6”(3.5 m) Trailer: Structural steel frame Leaf spring axle Wheels & tires: 15"
SPECIFICATIONS
However, if the running ambient temperatures are much higher than the starting tempera­tures, a compromise must be made and a higher viscosity oil used (provided starting is satisfactory). Multigrade oils overcome the problem, provided they have a suitable specification.
DOMESTIC SHIPPING WEIGHT
FUEL AND LUBRICATING OIL
The temperatures mentioned in the table are the ambient temperatures at the time the en­gine is started.
Fixtures: 15 Ibs. ea. = 60 Ibs. Trailer with mast: 1,990 Ibs. (902.7 kg) Total weight: 2,050 Ibs. (929.9 kg)
16
Page 17
SPECIFICATIONS
LPW-3 ENGINE
LISTER LPW-3 Alpha Series, direct injection 3 Cylinder
Displacement: 85.13 cu. (1396.13 cc)
Bore: 3.38 in. (8.6 cm)
Stroke: 3.15 in.(8.0 cm)
Power output: 16.5 BHP continuous
Power output derating: 3.5% for every 1000 ft
altitude (305 m)
above sea level
Air inlet temp: 2% per lO°F (5.6C) above 85° F(29.4C) Fuel: Diesel Fuel consumption: 1.25 ga (4.7L/hr) at less than 75%load Oil sump capacity (excluding filter): 4.0 US qt. (3.8L) Starting: 12 volt electric
Low oil pressure shutdown, high engine temp.
shutdown, and glow plug cold start assist are
standard.
KUBOTA D 1105-EBG1 ENGINE
Kubota D1105-EBG1, indirect injection 3 Cylinder
Displacement: 68.53 cu. (1.1 cm)
Bore: 3.07 in. (78 mm)
Stroke: 3.09 in. (78.4 mm)
Power output: 13.6 @ 1800 rpm
Power output derating: 3.0% for every1000 ft.
altitude (305 m)
above 360 ft.
Ambient temp: 1% per 10°F (5.6°C) above 77°F (25°C)
Fuel: Diesel
Fuel consumption: .63 gal (2.39 L)/hr
Starting: Glow plugs needed below 45 F. 12\/ electric
Oil sump capacity (excluding filter): 5.4 US qt. (5.14 L)
Low oil pressure shutdown, high engine
temp. shutdown, and glow plug cold start
assist are standard.
KUBOTA D905-EBG1 ENGINE
Kubota D905-EBG1, indirect injection 3 Cylinder Displacement: 54.80 cu. in.(898 cm) Bore: 2.83 in. (72 mm) Stroke: 2.90 in. (73.6 mm) Power output: 10.5 BHP@ 1800 rpm
Power output derating: 3.0% for every1000 ft.
altitude (305 m) above sea level
Ambient temp: 1% per 10° F (5.6°C) above 77°F (25°C) Fuel: Diesel
Fuel consumption: 0.63 US gal (2.39 L/hr) Starting: Glow plugs needed below 45' F. 12V electric Oil sump capacity (excluding filter) 5.40 US qt. (5.14L)
Low oil pressure shutdown, high engine
temp. shutdown, and glow plug cold start
assist are standard.
PERKINS 103.10 ENGINE
Perkins 103.10, Indirect injection 3 Cylinder
Displacement: 58.3 cu. in. (954 cc)
Bore: . 75 mm
Stroke: 72 mm
Power output: 10.7 BHP@ 1800 RPM
Power output derating: 3.5% for every 1000 ft
altitude (305 m) above sea level
Air Inlet Temp: 1% per 10°F (5.6C) above 77° F (25°C)
Fuel: Diesel Oil sump capacity: Fill to correct level Starting: 12 volt electric
Low oil pressure shutdown, high engine
temp. shutdown, and glow plug cold start
assist are standard.
17
Page 18
CONTROLS AND COMPONENTS
NOTE: COMPONENTS SHOWN ARE STANDARD. PICTURES MAY VARY WITH DIFFERENT OPTIONS.
FIGURE 1
FIG. 1. A.C. CONTROL PANEL
1. Switch, Circuit Breaker (Lights 1 through 4)
2. Switch, Circuit Breaker (24OV Receptacle)
3. Switch, Circuit Breaker (120\/ Receptacles)
!
SAFETY WARNING
FAILURE TO UNDERSTAND AND COMPLY WITH SAFETY RELATED INFORMATION AND INSTRUCTIONS MAY RESULT IN INJURY TO THE OPERATOR OR OTHERS. IF YOU DO NOT UNDERSTAND ANY PART OF THIS CONTACT YOUR DEALER FOR CLARIFICATION PRIOR TO OPERATING EQUIPMENT.
18
FIGURE 2
FIG. 2. D.C. CONTROL PANEL
4. Voltmeter (optional)
Indicates charging circuit voltage
5. Hour Meter Shows total elapsed hours of engine operation.
6. Momentary Contact Switch (Electric Winch Model) Lift up to raise and extend the tower. Press down to Iower and fold the tower.
7. Ignition ON/OFF Switch
8. Start Assist Switch Push to activate fuel solenoid and glow plug prior to and while depressing start switch.
9. Start Switch Push to start.
10. 1.5 AMP Circuit Breaker (Electric Winch Model)
Page 19
CONTROLS AND COMPONENTS
NOTE: COMPONENTS SHOWN ARE STANDARD. PICTURES MAY VARY WITH DIFFERENT OPTIONS.
FIG. 3 BALLAST PANEL
11. Ballast, Capacitors 1 through 4
12. Ballast, Transformers 1 through 4
!
FAILURE TO UNDERSTAND AND COMPLY WITH SAFETY RELATED INFORMATION AND INSTRUCTIONS MAY RESULT IN INJURY TO THE OPERATOR OR OTHERS. IF YOU DO NOT UNDERSTAND ANY PART OF THIS CONTACT YOUR DEALER FOR CLARIFICATION PRIOR TO OPERATING EQUIPMENT
FIG. 4 CONVENIENCE PANEL
13. 120 Volt/ 15 Amp Outlet Receptacles (Ground fault)
14. 240 Volt/ 15 Amp D.C. Outlet Receptacle
15. Power Cord Access Hole
SAFETY WARNING
19
Page 20
CONTROLS AND COMPONENTS
NOTE: COMPONENTS SHOWN ARE STANDARD. PICTURES MAY VARY WITH DIFFERENT OPTIONS.
FIG. 5 GROUND ROD
16. Ground Rod Ground rod should be attached to grounding lug with wire provided and ground rod and then driven fully into the earth for adequate electrical ground, as required by local, state, or national electrical code.
FIG. 6 ENGINE (Left Side)
17. Air Cleaner
18. Fuel Filter
19. Fuel Lift Pump
20. Fuse (10 Amp)
21. Oil fill
22. Stop Solenoid
23. Oil Filter
FIG. 7 ENGINE (Right Side)
24. Fuel Return Line
25. Fuel Suction Line
26. Starter
27. Glow Plug
20
Page 21
CONTROLS AND COMPONENTS
NOTE: COMPONENTS SHOWN ARE STANDARD. PICTURES MAY VARY WITH DIFFERENT OPTIONS.
FIG. 8 REAR JACK
28. RearJack
!
SAFETY WARNING
WHEN EXTENDING REAR JACK,
WATCH TO INSURE YOU ARE CLEAR OF THE OVERHANGING ENDS OF THE MAST BEFORE
FIG. 9 OUTRIGGER JACK
29. Pin--Retains outrigger in retracted position for towing
30. Jack Pin--Pull to allow jack to rotate
31. Outrigger Jack 32 Jack Handle--Crank handle to raise and lower foot of jack to level trailer.
FIG. 10 REAR TOWER SUPPORT
33.
Pin—Locks tower into rear tower support
34. Rear Tower Support
21
Page 22
CONTROLS AND COMPONENTS
NOTE: COMPONENTS SHOWN ARE STANDARD. PICTURES MAY VARY WITH DIFFERENT OPTIONS.
FIG. 11 TONGUE ASSEMBLY
35. Taillight Wiring Harness
36. Safety Tow Chains
37. Reversible Hitch (2” Ball and Pintle Hitch)
FIG. 12 FORKLIFT POCKETS
38. Forklift Pockets
39. Lifting Eye
FIG. 13 DOOR PROP
40. Door Prop—Locks Door Panel in Open Position
22
Page 23
CONTROLS AND COMPONENTS
NOTE: COMPONENTS SHOWN ARE STANDARD. PICTURES MAY VARY WITH DIFFERENT OPTIONS.
FIG. 14 KICKOUT SPRING
41. Kickout Spring—Tilts mast off center when folding mast down
FIG. 15 TOWER LOCKING BAR LATCH
42. Mast Locking Bar Latch --Locks mast in vertical position and allows tower to rotate.
NOTE: Tower must be positioned with the two black triangles on the tower assembly, near the mast handles, pointing at each other. Then the locking bar can be released from the strike plate allowing the tower to rotate toward horizontal towing position.
FIG. 16 MANUAL WINCH HANDLE
43. Winch Handle--Use to raise and fold mast.
23
Page 24
CONTROLS AND COMPONENTS
NOTE: COMPONENTS SHOWN ARE STANDARD. PICTURES MAY VARY WITH DIFFERENT OPTIONS.
FIG. 17 TOWER CONTROLS
44. Manual Winch
lower mast..
45. Tower Winch Handle
46. Alignment Arrows—Must be aligned to unlock the tower.
47.Lock Knob—Locks tower in position.
48.Mast Handles—Use to rotate tower and
lights.
—Use to extend and
FIG. 18 Cord Reel
49. Cord reel —Available on either Electric or Manual winch models
FIG. 19 Cord Reel
50. Lamp Connector Lead—For quick
connecting/disconnecting of the lamp fixtures
24
Page 25
CONTROLS AND COMPONENTS
NOTE: COMPONENTS SHOWN ARE STANDARD. PICTURES MAY VARY WITH DIFFERENT OPTIONS.
FIG. 20 Electric Winch
51. Dutton-Lainson Strong Arm Winch—Used to raise and extend, lower and fold mast.
52. Slack Limit Switch—Shuts off winch when cable slack is sensed by sensor arm.
NOTE: See pages 10-11, Strong Arm Electric Winch Mast Operation, for correct operating procedures.
FIG. 21 Electric Mast
53. Mast Handle—Use to rotate mast.
54. Lock Handle—Pull to unlock tower sections when raising tower.
55. Lock Pin—Prevents accidental release of lock when rotating mast.
25
Page 26
ROUTINE MAINTENANCE SCHEDULE
LISTER-PETTER LPW-3 INSPECTION AND LUBRICATION SCHEDULE
Check condition of the steel cable and make sure it is properly secured. Check hydraulic fluid level.
Lubrication grease specifications: N.G.L.I. consistency #2, high temperature anti-friction bearing lubricating grease.
Service intervals shown below have been established for operation under normal conditions. Where equipment is operated under severe conditions (very dusty, extreme heat or cold, etc.) affected items should be serviced more frequently.
INTERVAL ITEM PROCEDURE
Fuel level Check and fill as necessary.
Daily or 10 Hr.
125 Hr.
250 Hr.
500 Hr.
1000 hr. or yearly
Lubricating oil Check level and condition. Air Cleaner Clean under very dusty conditions. All 10 Hr. items As above
Air Cleaner
Battery Check level of electrolyte. Engine Generator assembly Check for fuel and lubricating oil leaks. All 125 Hr. items As above
Engine lubricating oil system
Fuel Injector Nozzles Clean if the exhaust is dirty
Fuel Filter
All 250 Hr. Items As above Fuel Filter Renew filter element. All 500 Hr. Items As above
Engine Service
Engine Valves Adjust clearance.
Engine Service
Cable pulley at the bottom of the front mast support Cable pulleys on mast Inspect for wear. Clean and lubricate. Axle wheel bearings Clean and repack. Fuel System Clean sediment from tank.
Change element if necessary or clean under moderately dusty conditions.
Drain lubricating oil, flush out system, renew filter element and refill with correct grade and type oil.
Renew filter element if fuel not perfectly clean.
Decarbonize if the engine shows loss of compression or blow-by past the piston. Do not disturb otherwise.
Clean the cylinder and cylinder head finning under dusty conditions if necessary.
Remove, clean, and grease.
26
Page 27
ROUTINE MAINTENANCE SCHEDULE
KUBOTA D905 and D1105 and PERKINS 103-10
INSPECTION AND LUBRICATION SCHEDULE
Check condition of the steel cable and make sure it is properly secured. Check hydraulic fluid level.
LUBRICATION GREASE SPECIFICATIONS:
N.G.L.I. consistency #2, high temperature anti-friction bearing lubricating grease.
Service intervals shown below have been established for operation under normal conditions. Where equipment is operated under severe conditions (very dusty, extreme heat or cold, etc.) affected items should be serviced more
frequently.
INTERVAL ITEM PROCEDURE
Daily or 10 Hr.
100 Hr.
200 Hr.
400 Hr. Fuel Filter Replace with new.
1000 hr. or yearly
KUBOTA AND ISUZU
Fuel level Che ck and fill as necessary Lubricating oil Check level and condition
All 10 Hr. items As above
Air Cleaner
Battery Check level of electrolyte
Engine Generator assembly
All 100 Hr. item s As above
Engine lubricating oil system
Coolant Check level and condition
All 200 Hr. Item s As above Fan belt Check tension and condition500 Hr. Radiator Clean out fins with water or air All 500 Hr. Item s As above Engine Valves Adjust clearance Cable pulley at the bottom of the front m ast support
Cable pulleys on mast
Axle wheel bearings C lean and repack Fuel Syste m Clean sediment from tank
Service as required. Service requirem ents may be accelerated
Check for fuel and lubricating oil leaks
Drain lubricating o il, flush out system, renew filter elem ent and refill with correct grade and type oil
Rem ove, clean, and grease
Ins pe ct for we ar. C lea n and lubricate
PERKINS ONLY
27
Page 28
TROUBLESHOOTING
!
SAFETY WARNING
DANGER!
HIGH VOLTAGE! DO NOT ATTEMPT TO TEST AND REPAIR GENERATOR AND
BALLAST ELECTRICAL SYSTEMS UNLESS YOU UNDERSTAND AND ARE QUALIFIED TO WORK ON SUCH SYSTEMS.
When one lamp does not light, leads with a lamp that ELECTRICITY! If the following procedures do not solve your problem, have the circuit tested by a licensed electrician. DO NOT attempt to test generator voltage or ballast electrical systems unless you are a qualified electrician. Consult the factory for voltage specifications and test procedures
DOES
TURN OFF THE GENERATOR
light.
DO NOT WEAR JEWELRY WHILE WORKING WITH
and test the lamp by switching
PROBLEM POSSIBLE CAUSE
1. Circuit breakers in the outlet box are not turned on or have tripped.
2. Lamps are not allowed time to cool after last being lit. You must allow 15 minutes between the time the lights are shut off and the time they are restarted.
3. The lam or lamps are burned out or broken.
4. One or more of the lamps are not screwed in securely.
5. Plug and socket at light bar not securely pushed together and locked.
6. The temperature of the ballast is below –20 degrees F. the efficiency of the capacitors in the ballast is not enough to ignite the lamps. For
ONE OR MORE LIGHTS DO NOT LIGHT UP.
operations where the temperatures of the ballasts falls below –20 degrees F. some means of warming the ballast must be used.
7. Low electrical system voltage.
8. A loose connection in the back of the lamp socket in the lamp holder.
9. A circuit breaker or breakers are defective.
10. A loose connection on the terminal board.
11. The engine and generator are not running up to speed (1800 RPM)
12. A wrong style replacement lamp (requiring a different ballast) has been installed.
13. Too much power is being drawn from the auxiliary outlets.
14. Capacitor or transformer have failed.
15. Corrosion has occurred on the lamp bases.
28
Loading...