CONVERTEON™ Family
AT-CVFAN Module Installation Guide
For use with the AT-CV5000 Chassis
Allied Telesis, Inc.
www.alliedtelesis.com
Related Documents
This installation guide is an abbreviated version of the installation procedure.
For details on the components, features, and functions of this product, refer to
the following documents on our web site, www.alliedtelesis.com:
❑ AT-CV5000 Media Converter Chassis Installation Guide
(PN 613-50580-00)
❑ AT-S70 Management Software User’s Guide (PN 613-50617-00)
Package Contents
Make sure the following items are included in the shipping package. If any
item is missing or damaged, contact your Allied Telesis sales representative
for assistance.
❑ One AT-CVFAN Module
❑ This Installation Guide
❑ Warranty Card
Locations of the Fan Slots
Figure 2 illustrates the locations of the two fan modules at the rear of the
AT-CV5000 chassis.
Replacing an AT-CVFAN Module
You can replace the AT-CVFAN module in either one of the two fan slots
located at the rear of the AT-CV5000 chassis.
Caution
For normal operation, both fans must be installed in the chassis.
Caution
The AT-CVFAN modules are field-replaceable; however, they are not
hot-swappable. Therefore, make sure to power OFF the chassis before
installing the fan modules.
To replace an AT-CVFAN module, perform the following procedure:
1. Power OFF the chassis.
2. Using a Phillips screwdriver, loosen the captive screws at the top and
bottom of the installed fan module faceplate.
3. Pull the loosened screws to slide the fan module out of the chassis, as
shown in Figure 3 or Figure 4.
Overview
The AT-CVFAN module, as shown in Figure 1, is designed for use with the
AT-CV5000 chassis. The same fan module can be installed in either fan slot
labeled A or B, located at the rear of the AT-CV5000 chassis. For proper
operation, an AT-CV5000 chassis comes preinstalled with two fieldreplaceable AT-CVFAN modules.
This installation guide provides instructions for the fan replacement in case
one of the AT-CVFAN modules failed.
AT-CVFAN
Figure 1. AT-CVFAN Module
201
A
AT-CVFAN
Fan Slot A
AB
100-240VAC
~
POWER
FAULT
AT-PWR14
AT-PWR14
POWER
FAULT
100-240VAC
~
Fan Slot B
Figure 2. Locations of Fan Slots A & B on an AT-CV5000 Rear Panel
Before replacing an AT-CVFAN module, please note the following guidelines:
Caution
Be sure to observe all standard electrostatic discharge (ESD) precautions, such as wearing an antistatic wrist strap, to avoid damaging
the device. A fan module can be damaged by static electricity.
Caution
Refer to the AT-CV5000 Chassis Installation Guide for electrical safety
and emission information.
Warning
Remove jewelry before replacing the fan modules.
B
AT-CVFAN
213
A
A
100-240
VAC
~
W
A
R
N
IN
T
h
G
is
u
n
i
t
r
m
e
d
ig
u
h
c
t
e
h
t
a
h
i
v
e
n
e
r
p
m
i
u
s
t
k
o
s
r
o
b
e
f
e
t
e
f
h
o
l
a
e
r
n
c
e
o
t
s
r
i
n
e
c
r
e
v
s
p
ic
h
o
o
i
n
w
c
g
k
e
,
u
r
d
i
n
n
is
it
p
c
.
u
o
t
n
.
T
n
o
e
c
t
a
l
l
p
o
w
e
r
AT-PWR14
POWER
FAULT
B
AT-CV5PWRAC
POWER
FAULT
Figure 3. Removing an AT-CVFAN Module from the Fan Slot A
B
B
~
C
A
V
0
4
2
-
0
0
1
o
T
t.
u
p
r
e
in
w
o
er
w
ll p
o
p
t a
e
c
n
e
n
o
n
n
o
sc
tha
i
re
d
,
o
k
c
m
o
G
e
h
v
a
s
IN
ic
N
t h
h
R
ctr
ig
A
le
it.
W
f e
n
it m
o
n
u
k
g
u
in
is
ris
h
ic
e
T
v
er
e th
s
c
u
re
d
e
fo
r
e
b
ts
u
p
in
AT-PWR14
R
E
W
PO
T
L
U
FA
4
2
-
0
0
1
~
C
A
V
0
A
AT-CV5PWRAC
Figure 4. Removing an AT-CVFAN Module from the Fan Slot B
100-240VAC
205
~
*613-50584-00 Rev C*
613-50584-00 Rev C 1
Warning
Watch your fingers when handling the fan modules.
Warning
To avoid electric shock, do not intend to touch the inside of the fan slots.
2 3
4. While waiting for the fan to spin down, unpack the new AT-CVFAN module
from the shipping package and store the packaging material in a safe
location.

Caution
Be sure to observe all standard electrostatic discharge (ESD)
precautions, such as wearing an antistatic wrist strap, to avoid
damaging the device. A fan module can be damaged by static
electricity.
Note
You must use the original shipping material if you need to return the fan
module to Allied Telesis.
5. Carefully remove the fan module from the chassis.
6. Make sure the handles on the fan modules are aligned to the side edges
of the chassis. For example, the handle on the fan module inserting into
Fan Slot A should be on the left and the handle on the module inserting
into Fan Slot B should be on the right, as shown in Figure 6.
Handles
on Left
AT-CVFAN module in
291
Fan Slot A
AT-CVFAN module in
Fan Slot B
Handles
on Right
292
Figure 5. Aligning the AT-CVFAN Modules to the AT-CV5000 Chassis
7. Align the new fan module with the bottom alignment guide, located inside
the fan slot.
8. Slide the new fan module into the fan slot, as shown in Figure 6 or
Figure 7, until the front of the fan module is flush with the front of the
chassis.
Caution
Avoid touching the fan blades.
B
B
~
C
A
100-240V
To
wer
po
wer input.
o
t all
an one p
k, disconnec
e more th
shoc
t hav
igh
t.
WARNING
risk of electric
This unit m
vicing uni
er
s
reduce the
inputs before
AT-PWR14
AT-CVFAN
203
T-CV5P
WRAC
R
E
W
O
P
T
L
U
A
F
Figure 7. Inserting an AT-CVFAN Module into the Fan Slot B
9. Tighten the two captive screws on the fan module, as shown in Figure 8 or
Figure 9.
A
A
1
0
AT-CVFAN
0
-2
4
0
V
A
C
~
W
A
R
N
IN
This unit m
G
reduce the risk of el
igh
t ha
inputs be
ve m
ore t
f
han one
ore ser
ectric sh
vicing
p
o
o
we
ck,
u
r input.
disco
n
it.
nn
To
ec
t all po
w
er
AT-PWR14
P
O
W
E
R
FA
U
LT
B
AT-CV5PWRAC
P
OW
E
R
F
A
U
LT
206
100
-240V
A
C
~
B
AT-CV5F
Figure 8. Tightening the Screws on the AT-CVFAN Module in Fan Slot A
B
AT-CVFAN
B
~
100-240VAC
ect all power
k, disconn
G
IN
N
R
A
W
of electric shoc
This unit might have more than one power input. To
ore servicing unit.
reduce the risk
inputs bef
AT-PWR14
R
E
W
O
P
LT
U
FA
100-240VAC
A
~
AT-CV5PWRAC
Technical Specifications
Physical and Environmental
Dimensions (H x W x L) 2.7 cm x 8.3 cm x 18.8 cm
1.080 in x 3.287 in x 7.395 in
Operating Temperature 0° C to 40° C (32° F to 104° F)
Storage Temperature -25° C to 70° C (-13° F to 158° F)
Operating Relative Humidity 5% to 90% RH (non-condensing)
Storage Relative Humidity 5% to 95% RH (non-condensing)
Operating Altitude Range Up to 3,048 m (10,000 ft)
Electrical Ratings
Rated Voltage 12V DC
Operation Voltage 7.0V DC - 13.2V DC
Input Current 0.23 A (maximum 0.34 A)
Input Power 2.76 W (maximum 4.08 W)
Electrical Safety and Emission Statement
Standards: This product meets the following standards when installed in compliant host equipment.
U.S. Federal Communications Commission
RADIATED ENERGY
Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant
to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in accordance with this instruction
manual, may cause harmful interference to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the user will be required to correct the interference at
his own expense.
Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right
to operate this equipment.
Industry Canada
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment
Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur
2
du Canada.
Emission FCC Class A, EN55022 Class A, VCCI Class A, C-TICK, CE
WARNING: In a domestic environment this product may cause radio interference in which case the
user may be required to take adequate measures.
Immunity EN55024
Electrical Safety UL60950 (UL/
UL), EN60950 (TUV), CSA22.2 No. 950
c
A
A
1
0
0
-2
4
0
V
A
C
~
W
A
R
N
IN
This unit m
G
reduce the risk of e
ight ha
inputs before ser
ve m
ore than one power input. To
le
ctric shoc
vicing unit.
k, disconn
ect all po
wer
AT-PWR14
P
O
W
E
R
F
A
U
L
T
AT-CVFAN
202
Figure 6. Inserting an AT-CVFAN Module into the Fan Slot A
4 5 6
AT-CV5PWRAC
P
O
W
E
R
F
A
U
LT
Figure 9. Tightening the Screws on the AT-CVFAN Module in Fan Slot B
You have completed the fan replacement procedure.
To power on the chassis, proceed to the procedure described in the
“Powering On an AC Powered Chassis” section in the AT-CV5000 Chassis
Installation Guide.
B
When the connection is established, the fan LED (FAN-A or FAN-B) on the
LED interface card should show green. If the LED is OFF, refer to the
“Troubleshooting” section in the AT-CV5000 Chassis Installation Guide.
No part of this publication may be reproduced without prior written permission from Allied Telesis Inc.
Copyright 2006 Allied Telesis, Inc. All rights reserved.