Allied Telesis AT-CV81S User Manual

Related Documents
3K
1 2 3 4
SW2
This installation guide is an abbreviated version of the installation procedure. For details on the components, features, and functions of this product, refer to the following documents on our web site, www.alliedtelesis.com:
Note
Local Console port and Half Duplex mode are not available in the current AT-S70 V1.5 software release.
CONVERTEON Family
AT-CV81S Media Converter Line Card
Installation Guide
Allied Telesis, Inc.
www.alliedtelesis.com
Overview
The AT-CV81S, see below, is a multi-protocol media converter that transports Asynchronous Serial Data (with Hardware Flow control, CTS/RTS) from a copper port, over a 100Base-FX fiber. It can be configured to support RS-232 or RS-422/485 serial data in Full duplex or Half duplex mode (available in future release).
The AT-CV81S line card can be installed in either the AT-CV5000, AT-CV1200, or AT-CV1000 chassis. This line card features one small form­factor pluggable (SFP) transceiver slot, one console port (8-pin Mini-DIN) and one serial port (9-pin Mini-DIN). The SFP slot can accommodate one SFP transceiver that operates at a fixed operating speed of 100 megabits per second (Mbps). The line card is hot-swappable into and out of the chassis.
1 2 3 4
K 3
2 W S
AT
-CV81S
L/A
S F P
CPU RES
ET
C O N S O L E
C O N S O L E
R
D
Y
SER
FD
SER
M
O
DE
A
HD
C
T
RS-2
32
RS-4
22/485
1146
AT-CV5000 Media Converter Chassis Installation Guide
PN 613-50580-00
AT-CV1000 Media Converter Chassis Installation Guide
PN 613-50582-00
AT-CV1200 Media Converter Chassis Installation Guide
PN 613-000331
Converteon™ Media Converter Line Cards Reference Guide
PN 613-50581-00
AT-S70 Management Software User’s Guide
PN 613-50617-00
Package Contents
Make sure the following items are included in the shipping package. If any item is missing or damaged, contact your Allied Telesis sales representative for assistance.
One AT-CV81S Line CardOne serial cable and one management cableThis Installation Guide and Warranty Card
AT-CV81S Line Card Components
The AT-CV81S line card features the following components:
One 100Base-FX SFP slot (SFP transceiver sold separately)One RS-232 serial local console interface with 8-pin Mini-DIN connectorOne RS-232/422/485 full-duplex serial port with 9-pin Mini-DIN connector
and port slide switches
One push button for local CPU resetOne DIP switchLEDs
Interface DIP Switch
SFP Transceiver LED
SFP Expansion Slot
CPU Reset Button
Console Port LED
Console Port
Serial Data Port
Serial Data Port LEDs
AT
-CV81S
L/A
S F P
C
PU
R
ES
E
T
C O N S O L E
C O N S O L E
R
D
Y
S
E
R
FD
S
M
E
O
R
D
E
A
HD
C
T
R
S
-2 32
RS
-4 2
2/485
1147
1 2 3 4
3K
2 W S
Features
The serial port supports RS-232/422/485 serial data transport over fiber.
SFP Slot, Local Console Port, and Serial Port
The AT-CV81S line card features one 100Base-FX SFP slot, one RS-232 local console port, and one RS-232/422/485 serial port with slide switches.
The SFP slot will accept one SFP transceiver that operates at a fixed operating speed of 100 Mbps.
Laser
Class 1 laser product.
Laser
Do not stare into the laser beam.
LEDs
The following table lists the line card status and basic alarms LED’s.
LED Color Description
RDY Green The line card has passed diagnostics.
OFF The line card has not passed diagnostics.
L/A Green The twisted pair port has established a valid link
Blinking Green
CONSOLE
Green The line card is managed from its local console. (applies to AT-CV5000
OFF The line card is managed from the CPM module chassis only)
SER MODE Green The serial port is operating in RS-232 mode.
Yellow The serial port is operating in RS-422/485
SER ACT Blinking
Green
Blinking
Yellow
OFF No activity detected on the serial data port.
The twisted pair port has detected TX/RX activity.
located in the rear of the chassis.
mode.
The serial data port has detected TX/RX activity in full-duplex mode.
The serial data port has detected TX/RX activity in half-duplex mode (available in future release).
*613-000566 Rev A*
613-000566 Rev A 1
Port Slide Switches
2 3
DIP Switch
The AT-CV81S line card features the Interface DIP Switch as listed in the table below.
Operating Mode DIP 1 DIP 2
Serial Port in RS-232 mode OFF X
Serial Port in RS-422/485 mode ON X
Manufacturing Default Settings (Default mode: RS-232 mode)
“X” means the DIP switch position could be either ON or OFF. DIP Switch 2 is reserved for Half-duplex configuration in future release
OFF OFF
Serial Data Port Slide Switches
The serial data port is assigned with two slide switches (SW3 & SW4). To support different serial protocol modes on a common straight data cable, these slide switches need to be configured per port basis as follows:
SW3 SW4 OPERATING MODE
LLRS-232
L L RS-485 (Half-Duplex)
L R Not Valid
R L Not Valid
RRRS-422
R R RS-485 (Full-Duplex)
L L Manufacturing Setting - RS-232 (Default)
L: Left, R: Right positions of the slide switch.
Installing an AT-CV81S Line Card
“X” means the DIP switch position could be either ON or OFF.
To install an AT-CV81S line card, perform the following procedure:
Caution
Before installing an AT-CV81S line card, refer to the appropriate
Converteon™ Series Chassis Installation Guide and/or the Converteon™ Media Converter Line Cards Reference Guide the for
electrical safety and emission information.
Caution
Be sure to observe all standard electrostatic discharge (ESD) precautions, such as wearing an antistatic wrist strap, to avoid damaging the device. A line card can be damaged by static electricity.
1. Remove the Converteon™ line card from its shipping package and store the package in a safe place.
2. You must use the original package if you need to return the unit to Allied Telesis.
3. Select an empty line card slot in the Converteon™ chassis for the card.
4. Remove the AT-CV5PNL1 blank slot cover from the selected slot.
Keep the blank slot cover in a safe area in case you remove the line card. The blank slot covers are used to keep dust from getting into the chassis and maintain proper airflow, cooling, and ventilation throughout the chas­sis.
5. Locate the alignment guides in the chassis slot.
6. Align the back edge of the line card with the alignment guides located inside the slot. Avoid touching the line card components. –- For the AT-CV5000, align with the top and bottom alignment guides. –- For the AT-CV1000 and AT-CV1200, align with the left and right alignment guides.
7. Slide the line card until the front of the card is flushed with the front of the chassis.
Technical Specifications
Physical, Environmental, and Electrical Rating
Dimensions (H x W x L) .855" x 2.89" x 5.1"
(2.2 cm x 7.3 cm x 13.0 cm)
Operating Temperature 0° C to 40° C (32° F to 104° F)
Storage Temperature -25° C to 70° C (-13° F to 158° F)
Operating Relative Humidity 5% to 90% RH (non-condensing)
Storage Relative Humidity 5% to 95% RH (non-condensing)
Operating Altitude Range Up to 3,048 m (10,000 ft)
MTBF (Telcordia Standards) 2,060,000 hrs
Power Consumption 3 watts
Pluggable Slot Type SFP
Electrical Safety and Emission Statement
Standards: This product meets the following standards when installed in compliant host equipment.
U.S. Federal Communications Commission
RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right to operate this equipment.
Industry Canada
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
Emission FCC Class A, EN55022 Class A, VCCI Class A, C-TICK, CE
WARNING: In a domestic environment this product may cause radio interference in which
Immunity EN55024
Electrical Safety UL60950-1 (
case the user may be required to take adequate measures.
), EN60950-1 (TUV), CAN/CSA C22.2 No. 60950-1
cULus
8. Use a Phillips screwdriver to tighten the captive screws on the line card.
Note
Always tighten the captive screws to secure the line card to the chassis. This help ensure that the connectors at the back of the line card are securely connected to the backplane.
Caution
When used in the AT-CV1200 chassis, make sure the ground lug is attached prior to operating the AT-CV81S line card. For grounding instruction, refer to the AT-CV1200 Chassis Installation Guide.
No part of this publication may be reproduced without prior written permission from Allied Telesis Inc.
Copyright 2006 Allied Telesis, Inc. All rights reserved.
4 5 6
Loading...