Allied Telesis AT-CV5M0x User Manual

*613-000805 Rev.B*
613-000805 Rev. B
AT-CV5M0x Management Card Installation Guide
Overview
The AT-CV5M0x Management Card, provides a CPU subsystem for an Allied Telesis Converteon Series chassis except for the AT-CV1000. The AT-CV5M0x Management Card is shipped with the management software preinstalled that allows you to configure and monitor the status of the media converter line cards in the chassis. The AT-CV5M0x Management Card is hot-swappable into and out of a Converteon chassis.
Related Documents
For details on the features and functions of a Converteon chassis, refer to the relevant documents on our web site, www.alliedtelesis.com.
Verifying Package Contents
Ensure that the following items are included in your package:
One AT-CV5M0x Management CardOne terminal port cable with a DB-9 connectorThis installation guide
If any item is missing or damaged, contact your Allied Telesis sales representative for assistance.
AT-CV5M0x Management Card Components
The AT-CV5M0x Management Card has the components shown below.
Line Card Status LEDs
RS-232 Terminal Port
AT-CV5M01
PW
R RDY FLT
Port Descriptions
Terminal Port
The default settings for the RS-232 terminal port are:
Baud rate: 115200 bps (range 2400 to 115200 bps)Data bits: 8Parity: NoneStop bits: 1Flow control: None
A terminal port cable is provided.
10/100Base-TX Twisted Pair Port
The 10/100Base-TX compliant twisted pair port allows you to establish a remote management session with a maximum operating distance of 100 meters (328 feet). The port requires a cable (not provided) with an 8-pin RJ-45 connector. The pinouts for this port are shown in “Twisted Pair Port Pinouts.”
Recessed CPU RESET Button
The recessed CPU RESET button allows you to reset only the management card. You may need to reset the management card after upgrading the firmware or after you have made a configuration change that requires resetting the card to activate the change.
Note
This reset button does not reset the line cards and/or the module installed in the expansion slot at the rear of the chassis.
LEDs
The management card has three status LEDs and the twisted pair port has three LEDs, as described in “LED Descriptions.”
Installing an AT-CV5M0x Management Card
Note
Before installing an AT-CV5M0x Management Card, refer to the appropriate Converteon chassis installation guide for electrical safety and emissions information.
Warning: Remove all metal jewelry, such as rings and watches, before installing or removing a line card from a powered-on chassis.
Caution: Be sure to observe all standard electrostatic discharge (ESD) precautions, such as wearing an antistatic wrist strap, to avoid damaging the device. A line card can be damaged by static electricity.
Note
You can install a Converteon line card in any Converteon chassis line card slot.
5. Secure the AT-CV5M0x Management Card to the chassis by using a Phillips screwdriver to tighten the captive screw on the management card faceplate.
Note
Always tighten the captive screw to secure the management card to the chassis. Leaving an AT-CV5M0x Management Card partially seated may cause the CPU to halt and subsequently crash.
For information about how to configure the terminal port and how to start a local or remote management session, refer to the relevant management software user’s guide.
For information about removing or resetting an installed AT-CV5M0x Management Card, refer to the installation guide for the chassis model you are using.
LED Descriptions
Status LED s
The management card has three status LEDs, as described in the following table.
LED State Description
PWR Green The management card is receiving power.
Off The management card is not receiving power if this LED is off for
more than 10 seconds.
RDY Green The management card has passed diagnostics and is ready.
Off The management card has failed diagnostics and is not ready.
FLT Red The management card has a fault condition.
Off The management card has not reported a fault condition.
Twisted Pair Port LEDs
The twisted pair port on the management card has three LEDs, as described in the following table.
LED Color Description
LK Green A link has been established on the port.
Blinking Green
Off No link has been established on the port.
AT Blinking
Green
Off There is no TX/RX activity on the port.
FD Green The port is operating in full-duplex mode.
Off The port is operating in half-duplex mode.
While in Smart MissingLink mode, a valid connection is established on the port while a link on the other port is lost.
TX/RX activity has been detected on the port.
Twisted Pair Port LEDs
10/100-TX Twisted Pair Port
Recessed CPU Reset Button
LK
A
CPU RESET
T FD
240
To install an AT-CV5M0x Management Card, perform the following procedure:
1. Remove the AT-CV5M0x Management Card from its shipping package and store the package in a safe location. You must use the original package if you need to return the unit to Allied Telesis.
2. Select any line card slot in the chassis where you want to install the management card, and remove the blank slot cover if one is installed.
3. Align the back edge of the management card with the top and bottom alignment guides located inside the slot.
4. Slide the management card into the slot until the front of the card is flush with the front of the chassis.
Note
Avoid touching the line card components.
1 2 3
Twisted Pair Port Pinouts
The pinouts for the RJ-45 twisted pair port are shown in the following illustration.
8
1
The following table lists the RJ-45 pin signals when a twisted pair port is operating in the MDI or MDI-X mode.
MDI Mode MDI-X Mode
Pin Signal Pin Signal
8
1
Electrical Safety and Emissions Statements
This product meets the following standards when installed in compliant host equipment.
U.S. Federal Communications Commission
RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right to operate this equipment.
1 TX+ 1 RX+
2 TX- 2 RX-
3 RX+ 3 TX+
6 RX- 6 TX-
Warranty Information
The AT-CV5M0x Management Card has a limited warranty of five years. Go to www.alliedtelesis.com/warranty for the specific terms and conditions of the warranty and for warranty registration.
Specifications
Dimensions (H x W x L) 2.2 cm x 7.3 cm x 13.0cm
(.855 in. x 2.89 in. x 5.1 in.)
Weight 0.27 kg (0.60 lbs.)
Operating Temperature 0° C to 40° C (32° F to 104° F)
Storage Temperature -25° C to 70° C (-13° F to 158° F)
Operating Relative Humidity 5% to 90% (non-condensing)
Storage Relative Humidity 5% to 95% (non-condensing)
Operating Altitude Range Up to 3,048 m (10,000 ft.)
Predicted MTBF (Telcordia SR332) 1,320,000 hours
Input Supply Voltage 5V DC, 3.3 V DC
Maximum Input Current 1.15 A (5V DC), 0.86 A (3.3V DC)
Power Consumption 9.6 Watts maximum
Industry Canada
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
Emissions FCC Class A, EN55022 Class A, VCCI Class A, C-TICK, CE
Warning: In a domestic environment this product may cause radio interference in which
case the user may be required to take adequate measures.
Immunity EN55024
Electrical Safety UL60950 (
), EN60950 (TUV), CSA22.2 No. 950
cULus
Copyright © 2007 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesis Inc.
4 5 6
Loading...