Datasheet | Media Converters
CV10x SERIES
ConverteonTMSeries Line Card
AT-CV101
100TX, 100FX (ST)
media converter line card
AT-CV102
100TX, 100FX (SC)
media converter line card
AT-CV102/1
100TX, 100FX (SC, 15km)
media converter line card
AT-CV102/2
100TX, 100FX (SC, 40km)
media converter line card
Overview
The CV10x series Ethernet media converters
include the following models:
• AT-CV101
• AT-CV102
• AT-CV102/1
• AT-CV102/2
The CV10x series Ethernet media converter line
cards are designed to extend the distance of
y interconnecting LAN devices
k b
our netw
y
that are physically separated by large distances.
The range of line cards support both multi-mode
and single-mode f
40km. Compliant with IEEE standards, these
con
standards-based media converters, switches, fiber
interface cards, etc over the fiber optic cable.
Extend the Distance of Ethernet
Each CV10x series media converter line card
features a 100TX twisted pair port and a 100FX
optical port. The twisted pair port has an RJ-45
connector and a maximum operating distance of
100 meter
model,
m
distances up to 40km.These cards can oper
half and full-duplex.
The AT-CV101 fiber optic port has a multi-mode
fiber ST connector and a maximum operating
distance of 2km (1.24 miles).
or
s, at distances up to
iber pair
s will inter-operate with other
ter
er
v
s (328 feet). Depending on the
ter card can oper
er
the media con
ulti-mode or single-mode f
v
iber o
er var
v
ate in
ious
ate at
The AT-CV102 fiber optic port has a multi-mode
fiber SC connector and a maximum operating
distance of 2km (1.24 miles).
The AT-CV102/1 fiber optic port has a singlemode fiber SC connector and a maximum
operating distance of 15km (9.32 miles).
The AT-CV102/2 fiber optic port has a singlemode fiber SC connector and a maximum
operating distance of 40km (24.85 miles).
Flexible Deployment
The CV10x series of line cards can be installed in
the complete range of Converteon chassis’,
allowing them to be deployed in a stand-alone
fashion (AT-CV1000), or in a multi-slot chassis
(AT-CV5000). When deployed in a multi-slot
chassis, the line cards can be unmanaged, or
managed with the inclusion of at least one
management card in the chassis. In unmanaged
mode, the line cards can be easily configured using
DIP switches, whereas in a managed chassis, all the
configuration can be performed remotely.
Whatever the chassis, the line cards can be hot
swapped pro
mechanism to simply perform moves/adds/
changes without having to power down other
ts of the netw
par
MissingLinkTMand Smart MissingLinkTM(SML)
The MissingLink (ML) feature allows the ports
on the media converter blade to pass the ‘Link’
status of their connections to each other. When
the media converter detects a problem with one
of the ports, such as the loss of connection to a
node, it shuts down the connection to the other
port, thus notifying the node that the connection
has been lost. Smart MissingLink (SML)
is when a link is lost on a port, the Link LED of
the port which still has a valid connection to its
end node starts to blink. These features allow
network administrators to quickly troubleshoot
netw
Hassle F
Allied
All
cards offer free technical support, ensuring
troub
viding the network manager with a
k.
or
lems.
k prob
or
ee Suppor
r
elesis Ethernet Media Converter line
T
le-free installation.
t
Key Features
• Extends Fast Ethernet networks
• Auto MDI/MDI-X
• Auto-negotiation (IEEE 802.3u-compliant)
• Support MissingLink and Smart MissingLink
• Transparent to IEEE 802.1Q VLAN packets
• Managed or unmanaged operation
• System and port LEDs
• Line card for all Converteon series chassis’
elesis www.alliedtelesis.com
T
Allied
CV10x SERIES | Converteon Series Line Card
Link Test, MissingLink,
a
nd Smart MissingLink Functions
Link Test
The link test is a fast and easy way for you to test the
connections between the media converter ports and the
end-nodes that are connected to the ports. If a network
problem occurs, you can perform a link test to determine
which port is experiencing a problem, and so be able to
focus your troubleshooting efforts on the cable or end-node
where the problem resides.
M
issingLink
The MissingLink feature enables the two ports on the media
converter to pass the ‘Link’ status of their connections to each
other. When the media converter detects a loss of connection
to an end-node, the media converter shuts down the
connection to the other port, thus notifying the end-node that
the connection has been lost.
Smart MissingLink
The Smart MissingLink feature performs exactly the same
function as MissingLink with one additional feature. When a
link is lost on a port, the LINK LED of the port which still
has a valid connection to its end-node starts to blink. This
ws you to quickly determine which port still has a valid
allo
connection (LINK LED blinking) and which port has lost its
connection (LINK LED off).
Technical Specifications
Status Indicators
System LEDs
LED Color
Description
RDY Green The line card has passed diagnostics
Off The line card has not passed diagnostics
ML Green MissingLink mode is enabled
Off MissingLink mode is disabled
SML Green Smart MissingLink mode is enabled
Off Smart MissingLink mode is disabled
ort LEDs
Fiber P
LED Color Description
LK Green Link established on the port
Off No link established on the port
TX/RX activity detected on the port
Green
T
A
Off No activity detected on the port
t LEDs
Copper P
or
LED Color Description
LK Green Link established on the port
Off No link established on the port
AT Green TX/RX activity detected on the port
No activity detected on the port
Off
FD Green Port operating in full-duplex mode
Off Port operating in half-duplex mode
DIP Switches
The AT-CV102 line card features both the Diagnostic Mode
(Table 1) and Port Configuration (Table 2) DIP switches. The
tables below list the positions of the DIP switches.
Table 1. Diagnostic Mode DIP Switches Positions
perating ModeDIP 1DIP 2DIP 3DIP 4
O
Link Test (default) Off Off X X
Smart MissingLink
Off On X X
(SML)
MissingLink (ML) On Off X X
Manufacturing
Off Off Off Off
Settings
‘X’ means the DIP switch position could be either On or Off.
Table 2 lists the Port Configuration DIP switches positions.
Table 2. Port Configuration DIP Switches Positions
Operating Mode DIP 1 DIP 2 DIP 3 DIP 4
Auto MDI-X Enabled
X Off X X
(default)
Auto MDI-X Disabled X Off X X
Manufacturing
Off Off Off Off
Settings
‘X’ means the DIP switch position could be either On or Off.
Physical Specifications
Dimensions 2.2cm x 7.3cm x 13cm
(W x D x H) (0.855” x 2.89” x 5.1”)
Weight 0.27kg (0.60lbs)
Optical Characteristics
Connector type Dual SC or dual ST
Fiber type Single-mode or multi-mode
Operating distance 2km (1.24 miles) to 40km (24.8 miles)
Optical Output Power (dBm)
Product
Minimum Maximum Wavelength Connector
AT-CV101 -20dBm to -14dBm 1310nm Dual ST
-14dBm 1310nm Dual SC
er Sensitivity (dBm)
w
Maximum
er P
-20dBm to
o
Minimum
-CV102
T
A
-CV102/1 -15dBm to -5dBm 1310nm Dual SC
T
A
A
T-CV102/2 -15dBm to 0dBm 1310nm Dual SC
Receiv
Product
AT-CV101 -31dBm to -11dBm
AT-CV102 -31dBm to -11dBm
AT-CV102/1 -34dBm to -3dBm
AT-CV102/2 -34dBm to -3dBm
Power Characteristics
Power consumption 5.7W
Environmental Specifications
Maximum operating temperature: 0°C to 40°C
(32°F to 104°F)
Maximum storage temperature: -25°C to 70°C
(-13°F to 158°F)
Operating and storage altitude: Up to 3,048
meters
(10,000 feet)
Relative humidity operating and
storage (non-condensing): 5% to 95%
Predicted MTBF (Telcordia SR332):
AT-CV101 1,020,000 hrs
AT-CV102 890,000 hrs
AT-CV102/1 1,020,000 hrs
AT-CV102/2 1,020,000 hrs
Standards
EMI part 15:
FCC class A, EN55022 class A, VCCI class A, C-Tick, CE
Immunity:
EN55024
Safety:
UL60950-1 (cULUS), EN60950-1 (TUV)
EN60825
Ordering Information
AT-CV101
Fast Ethernet Converteon media converter line card,
100TX to 100FX, MMF, ST, 2km
AT-CV102
Fast Ethernet Converteon media converter line card,
100TX to 100FX, MMF, SC, 2km
AT-CV102/1
net Con
ast Ether
F
100TX to 100FX,
-CV102/2
T
A
ast Ethernet Converteon media converter line card,
F
teon media converter line card,
ver
SMF, SC, 15km
100TX to 100FX, SMF, SC, 40km
19800 Nor
|
USA Headquar
European Headquarters | Via Motta 24 | 6830 Chiasso | Switzerland | T: +41 91 69769.00 | F: +41 91 69769.11
Asia-Pacific Headquar
ters
ters
th Creek Parkway | Suite 200 | Bothell | WA 98011 | USA | T: +1 800 424 4284 | F: +1 425 481 3895
pore | 534182 | T: +65 6383 3832 | F: +65 6383 3830
Singa
T
11
|
ai Seng Link
|
www.alliedtelesis.com
. All rights reserved. Information in this document is subject to change without notice. All company names, logos, and product designs that are trademarks or registered trademar ks are the property of their respective owners. 617-0001 69 Rev E
elesis Inc
T
Allied
2007
©