Allied Telesis AT-CV10x User Manual

Datasheet | Media Converters
CV10x SERIES
ConverteonTMSeries Line Card
AT-CV101
100TX, 100FX (ST) media converter line card
AT-CV102
100TX, 100FX (SC) media converter line card
AT-CV102/1
100TX, 100FX (SC, 15km) media converter line card
100TX, 100FX (SC, 40km) media converter line card
Overview
The CV10x series Ethernet media converters include the following models:
AT-CV101
AT-CV102
AT-CV102/1
AT-CV102/2
The CV10x series Ethernet media converter line cards are designed to extend the distance of
y interconnecting LAN devices
k b
our netw
y that are physically separated by large distances. The range of line cards support both multi-mode and single-mode f 40km. Compliant with IEEE standards, these con standards-based media converters, switches, fiber interface cards, etc over the fiber optic cable.
Extend the Distance of Ethernet
Each CV10x series media converter line card features a 100TX twisted pair port and a 100FX optical port. The twisted pair port has an RJ-45 connector and a maximum operating distance of 100 meter model, m distances up to 40km.These cards can oper half and full-duplex.
The AT-CV101 fiber optic port has a multi-mode fiber ST connector and a maximum operating distance of 2km (1.24 miles).
or
s, at distances up to
iber pair
s will inter-operate with other
ter
er
v
s (328 feet). Depending on the
ter card can oper
er
the media con
ulti-mode or single-mode f
v
iber o
er var
v
ate in
ious
ate at
The AT-CV102 fiber optic port has a multi-mode fiber SC connector and a maximum operating distance of 2km (1.24 miles).
The AT-CV102/1 fiber optic port has a single­mode fiber SC connector and a maximum operating distance of 15km (9.32 miles).
The AT-CV102/2 fiber optic port has a single­mode fiber SC connector and a maximum operating distance of 40km (24.85 miles).
Flexible Deployment
The CV10x series of line cards can be installed in the complete range of Converteon chassis’, allowing them to be deployed in a stand-alone fashion (AT-CV1000), or in a multi-slot chassis (AT-CV5000). When deployed in a multi-slot chassis, the line cards can be unmanaged, or managed with the inclusion of at least one management card in the chassis. In unmanaged mode, the line cards can be easily configured using DIP switches, whereas in a managed chassis, all the configuration can be performed remotely.
Whatever the chassis, the line cards can be hot swapped pro mechanism to simply perform moves/adds/ changes without having to power down other
ts of the netw
par
MissingLinkTMand Smart MissingLinkTM(SML)
The MissingLink (ML) feature allows the ports on the media converter blade to pass the ‘Link’ status of their connections to each other. When the media converter detects a problem with one of the ports, such as the loss of connection to a node, it shuts down the connection to the other port, thus notifying the node that the connection has been lost. Smart MissingLink (SML) is when a link is lost on a port, the Link LED of the port which still has a valid connection to its end node starts to blink. These features allow network administrators to quickly troubleshoot netw
Hassle F
Allied
All cards offer free technical support, ensuring troub
viding the network manager with a
k.
or
lems.
k prob
or
ee Suppor
r
elesis Ethernet Media Converter line
T
le-free installation.
t
Key Features
Extends Fast Ethernet networks
Auto MDI/MDI-X
Auto-negotiation (IEEE 802.3u-compliant)
Support MissingLink and Smart MissingLink
Transparent to IEEE 802.1Q VLAN packets
Managed or unmanaged operation
System and port LEDs
Line card for all Converteon series chassis’
elesis www.alliedtelesis.com
T
Allied
CV10x SERIES | Converteon Series Line Card
Link Test, MissingLink, a
nd Smart MissingLink Functions
Link Test
The link test is a fast and easy way for you to test the connections between the media converter ports and the end-nodes that are connected to the ports. If a network problem occurs, you can perform a link test to determine which port is experiencing a problem, and so be able to focus your troubleshooting efforts on the cable or end-node where the problem resides.
M
issingLink
The MissingLink feature enables the two ports on the media converter to pass the ‘Link’ status of their connections to each other. When the media converter detects a loss of connection to an end-node, the media converter shuts down the connection to the other port, thus notifying the end-node that the connection has been lost.
Smart MissingLink
The Smart MissingLink feature performs exactly the same function as MissingLink with one additional feature. When a link is lost on a port, the LINK LED of the port which still has a valid connection to its end-node starts to blink. This
ws you to quickly determine which port still has a valid
allo connection (LINK LED blinking) and which port has lost its connection (LINK LED off).
Technical Specifications
Status Indicators
System LEDs
LED Color
Description
RDY Green The line card has passed diagnostics
Off The line card has not passed diagnostics
ML Green MissingLink mode is enabled
Off MissingLink mode is disabled
SML Green Smart MissingLink mode is enabled
Off Smart MissingLink mode is disabled
ort LEDs
Fiber P
LED Color Description
LK Green Link established on the port
Off No link established on the port
TX/RX activity detected on the port
Green
T
A
Off No activity detected on the port
t LEDs
Copper P
or
LED Color Description
LK Green Link established on the port
Off No link established on the port
AT Green TX/RX activity detected on the port
No activity detected on the port
Off
FD Green Port operating in full-duplex mode
Off Port operating in half-duplex mode
DIP Switches
The AT-CV102 line card features both the Diagnostic Mode (Table 1) and Port Configuration (Table 2) DIP switches. The tables below list the positions of the DIP switches.
Table 1. Diagnostic Mode DIP Switches Positions
perating ModeDIP 1DIP 2DIP 3DIP 4
O
Link Test (default) Off Off X X
Smart MissingLink
Off On X X
(SML) MissingLink (ML) On Off X X
Manufacturing
Off Off Off Off
Settings
‘X’ means the DIP switch position could be either On or Off.
Table 2 lists the Port Configuration DIP switches positions.
Table 2. Port Configuration DIP Switches Positions
Operating Mode DIP 1 DIP 2 DIP 3 DIP 4
Auto MDI-X Enabled
X Off X X
(default) Auto MDI-X Disabled X Off X X
Manufacturing
Off Off Off Off
Settings
‘X’ means the DIP switch position could be either On or Off.
Physical Specifications
Dimensions 2.2cm x 7.3cm x 13cm (W x D x H) (0.855” x 2.89” x 5.1”) Weight 0.27kg (0.60lbs)
Optical Characteristics
Connector type Dual SC or dual ST Fiber type Single-mode or multi-mode Operating distance 2km (1.24 miles) to 40km (24.8 miles)
Optical Output Power (dBm)
Product
Minimum Maximum Wavelength Connector
AT-CV101 -20dBm to -14dBm 1310nm Dual ST
-14dBm 1310nm Dual SC
er Sensitivity (dBm)
w
Maximum
er P
-20dBm to
o
Minimum
-CV102
T
A
-CV102/1 -15dBm to -5dBm 1310nm Dual SC
T
A A
T-CV102/2 -15dBm to 0dBm 1310nm Dual SC
Receiv
Product
AT-CV101 -31dBm to -11dBm AT-CV102 -31dBm to -11dBm AT-CV102/1 -34dBm to -3dBm AT-CV102/2 -34dBm to -3dBm
Power Characteristics
Power consumption 5.7W
Environmental Specifications
Maximum operating temperature: 0°C to 40°C
(32°F to 104°F)
Maximum storage temperature: -25°C to 70°C
(-13°F to 158°F)
Operating and storage altitude: Up to 3,048
meters (10,000 feet)
Relative humidity operating and storage (non-condensing): 5% to 95%
Predicted MTBF (Telcordia SR332):
AT-CV101 1,020,000 hrs AT-CV102 890,000 hrs AT-CV102/1 1,020,000 hrs AT-CV102/2 1,020,000 hrs
Standards
EMI part 15:
FCC class A, EN55022 class A, VCCI class A, C-Tick, CE
Immunity:
EN55024
Safety:
UL60950-1 (cULUS), EN60950-1 (TUV) EN60825
Ordering Information
AT-CV101
Fast Ethernet Converteon media converter line card, 100TX to 100FX, MMF, ST, 2km
AT-CV102
Fast Ethernet Converteon media converter line card, 100TX to 100FX, MMF, SC, 2km
AT-CV102/1
net Con
ast Ether
F 100TX to 100FX,
-CV102/2
T
A
ast Ethernet Converteon media converter line card,
F
teon media converter line card,
ver SMF, SC, 15km
100TX to 100FX, SMF, SC, 40km
19800 Nor
|
USA Headquar European Headquarters | Via Motta 24 | 6830 Chiasso | Switzerland | T: +41 91 69769.00 | F: +41 91 69769.11 Asia-Pacific Headquar
ters
ters
th Creek Parkway | Suite 200 | Bothell | WA 98011 | USA | T: +1 800 424 4284 | F: +1 425 481 3895
pore | 534182 | T: +65 6383 3832 | F: +65 6383 3830
Singa
T
11
|
ai Seng Link
|
www.alliedtelesis.com
. All rights reserved. Information in this document is subject to change without notice. All company names, logos, and product designs that are trademarks or registered trademar ks are the property of their respective owners. 617-0001 69 Rev E
elesis Inc
T
Allied
2007
©
Loading...