Introduction
This patch release note lists the issues addressed and enhancements made in
patch 86222-06 for Software Release 2.2.2 on existing models of Rapier L3
managed switches and AR800 Series L3 modular switching routers. Patch file
details are listed in Table 1.
Table 1: Patch file details for Patch 86222-06.
Base Software Release File
Patch Release Date
Compressed Patch File Name
Compressed Patch File Size
This release note should be read in conjunction with the following documents:
■
Release Note: Software Release 2.2.2 for Rapier Switches, AR300 and
AR700 Series Routers, and AR800 Series Modular Switching Routers
(Document Number C613-10313-00 Rev A) available from
www.alliedtelesyn.co.nz/documentation/documentation.html
■
Rapier Switch Documentation Set for Software Release 2.2.1 available on
the Documentation and Tools CD-ROM packaged with your switch, or
from www.alliedtelesyn.co.nz/documentation/documentation.html
■
AR800 Series Modular Switching Router Documentation Set for Software
Release 2.2.1 available on the Documentation and Tools CD-ROM
packaged with your switching router, or from www.alliedtelesyn.co.nz/
documentation/documentation.html
WARNING: Using a patch for a different model or software release may cause
unpredictable results, including disruption to the network. Information in this
release note is subject to change without notice and does not represent a
commitment on the part of Allied Telesyn International. While every effort has
been made to ensure that the information contained within this document and
the features and changes described are accurate, Allied Telesyn International
can not accept any type of liability for errors in, or omissions arising from the
use of this information.
86s-222.rez
30-Aug-2001
86222-06.paz
226776 bytes
.
.
.
Simply connecting the world
![](/html/25/2515/2515ad05eaeb074936485380e984dea97aa21d4b856a37ed65fe0b831c72c0e0/bg2.png)
2 Patch Release Note
Features in 86222-06
Patch 86222-06 includes all issues resolved and enhancements released in
previous patches for Software Release 2.2.2, and the following enhancements:
PCR: 01188 Module: SWI Network affecting: No
The power supply voltages of the base board PHYs on a Rapier G6 are
controlled by a PHY register value, which was incorrectly set. This issue has
been resolved.
PCR: 01190 Module: PIM Network affecting: No
In PIM Dense Mode, if a data stream started before PIM hello messages
were exchanged, the receiver did not get the data stream. This issue has
been resolved.
PCR: 01192 Module: SWI Network affecting: No
The Rapier G6 base ports sometimes experienced spurious link up or link
down events. This issue has been resolved.
Features in 86222-05
Patch file details for Patch 86222-05 are listed in Table 2.
Table 2: Patch file details for Patch 86222-05.
Base Software Release File
Patch Release Date
Compressed Patch File Name
Compressed Patch File Size
Patch 86222-05 includes all issues resolved and enhancements released in
previous patches for Software Release 2.2.2, and the following enhancements:
PCR: 01148 Module: SWI Network affecting: No
A39 copper uplink modules in the Rapier G6 sometimes experienced
spurious link up or link down events. This issue has been resolved.
PCR: 01157 Module: CORE Network affecting: No
The enterprise MIB now supports objects for power supply monitoring.
86s-222.rez
24-Aug-2001
86222-05.paz
223728 bytes
PCR: 01162 Module: PKI Network affecting: No
Certificates containing GeneralisedTime with the year in YYYY format are
now parsed correctly. The keyUsage field of certificates is now parsed
correctly when only one byte has been specified. The CRL update time is now
displayed correctly in hours. If the username and password parameters are
present the location parameter must be present and appear before the
username and password parameters. Certificates with signatures of 257 bytes
are now correctly parsed. Certificates added from a configuration script are
now processed correctly.
Patch 86222-06 for Software Release 2.2.2
C613-10319-00 REV F
![](/html/25/2515/2515ad05eaeb074936485380e984dea97aa21d4b856a37ed65fe0b831c72c0e0/bg3.png)
Patch 86222-06 For Rapier Switches and AR800 Series Modular Switching Routers 3
PCR: 01170 Module: IPv6 Network affecting: No
A fatal error occurred if an IPv6 interface was deleted while packets were
being transmitted. The number of current interfaces was not being updated
correctly when a new IPv6 interface was added. As a result, after multiple
additions and deletions, no more IPv6 interfaces could be added. These
issues have been resolved.
PCR: 01176 Module: PKI Network affecting: No
The CREATE CONFIG command now adds PKI certificates to the script in
the same order that they were originally added to the certificate database.
PCR: 01177 Module: PKI Network affecting: No
PKI certificates are now periodically checked (once per hour) to verify that
they are still valid.
PCR: 01178 Module: IPSEC Network affecting: No
IPCOMP SA’s which have the reserved CPI “3” are no longer deleted by
ISAKMP delete messages.
PCR: 01179 Module: SWI Network affecting: No
When a VLAN was created and then destroyed on the G6 or G6F, the
VTABLE was corrupted. This has been fixed.
PCR: 01181 Module: DHCP Network affecting: No
DHCP failed to send request messages when it was in a rebinding or
renewing state. This issue has been resolved.
PCR: 01185 Module: SWI Network affecting: No
In some extreme traffic conditions the switch could lock up, preventing
switching of any traffic. This issue has been resolved.
PCR: 01186 Module: FIREWALL Network affecting: No
When large numbers of sessions were being handled the firewall would
become overly aggressive in restricting new sessions. The Active TCP Opens
field in the output of the SHOW FIREWALL POLICY would show a very
high number (42 × 10
8
). This issue has been resolved.
PCR: 01187 Module: IPG Network affecting: No
If the IGMP table was empty and a timeout was set, a fatal error occurred.
This issue has been resolved.
Patch 86222-06 for Software Release 2.2.2