Alliance Laundry Systems W001C User Manual

Automatic
Washers
Home Laundry
Installation
Para bajar una copia de estas instrucciones en español, visite www.comlaundry.com.
Keep These Instructions for Future Reference.
(If this machine changes ownership, this manual must accompany machine.)
www.comlaundry.com
W001C
W001C
Part No. 39239R4
Table of
Contents
Replacement Parts .............................................................................. 2
Installation........................................................................................... 3
Roughing in Dimensions ...................................................................... 3
Before You Start ................................................................................... 4
Tools ................................................................................................ 4
Electrical .......................................................................................... 4
Water................................................................................................ 4
Installing the Washer ............................................................................ 5
Step 1: Remove the Shipping Brace and Shipping Plug.................. 5
Step 2: Wipe Out Inside of Washtub ............................................... 5
Step 3: Connect Fill Hoses............................................................... 6
Step 4: Connect Drain Hose to Drain Receptacle ............................ 7
Step 5: Position and Level the Washer ............................................ 10
Step 6: Plug in the Washer............................................................... 11
Step 7: Add Water to the Washer .................................................... 11
Step 8: Check Lid Switch ................................................................ 11
Step 9: Check Installation ................................................................ 11
Electrical Requirements........................................................................ 12
Grounding Instructions .................................................................... 12
Water Supply Requirements................................................................. 13
Water Temperature .......................................................................... 13
Water Pressure ................................................................................. 13
Risers................................................................................................ 14
Installer Checklist................................................................ Back Cover
© Copyright 2007, Alliance Laundry Systems LLC All rights reserved. No part of the contents of this book may be reproduced or transmitted in any form or by any
means without the expressed written consent of the publisher.
39239
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
1

Replacement Parts

If replacement parts are required, contact the source from which you purchased your washer, or contact:
Alliance Laundry Systems Shepard Street P.O . Bo x 99 0 Ripon, WI 54971-0990 Phone: (920) 748-3950
for the name and address of the nearest authorized parts distributor.
2
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 39239
Roughing in Dimensions

Installation

22.13 in.
(56.2 cm)
(71.1 cm)
28 in.
*53 in. (134.6 cm)
25.6 in. (65 cm)
*With leveling legs turned into base.
*29 in. (73.7 cm)
*43 in. (109.2 cm)
0.4 in. (1 cm)
*40.25 in. (102.2 cm)
*36 in. (91.4 cm)
26 in.
(66 cm)
TLW2075N
39239
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
3
Installation
Before You Start

Tools

For most installations, the basic tools you will need are:
2
1
1 Wrench 2 Screwdriver 3 Pliers 4 Level
3
4
D074I

Electrical

Refer to serial plate for specific electrical requirements. For more detailed information, refer to section on Electrical Requirements.

Water

Washer needs two standard 3/4 inch (19.1 mm) water supply faucets with a pressure between 20 to 120 pounds per square inch (138 and 827 kPa). For more detailed information, refer to section on Water Supply Requirements.

Figure 1

4
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
39239
Installation
Installing the Washer
NOTE: If the washer is delivered on a cold day (below freezing), or is stored in an unheated room or area during the cold months, do not attempt to operate it until the washer has had a chance to warm up.

Step 1: Remove the Shipping Brace and Shipping Plug

NOTE: Install dryer before washer. This allows room for attaching exhaust duct.
Remove the shipping brace from under the lid. The plastic shipping plug will be released from the base of the washer when removing the cardboard base from the washer.

Step 2: Wipe Out Inside of Washtub

Prior to first wash, use an all purpose cleaner, or a detergent and water solution, and a damp cloth to remove shipping dust from inside of washtub.
W371I
Figure 3
1
2
TLW521N
1 Shipping Brace 2 Shipping Plug

Figure 2

NOTE: Do not tilt washer to front or sides when moving.
The shipping brace and plug should be saved and must be reinstalled whenever washer is moved or transported to a new location. This will prevent damage to washer components.
NOTE: Refer to your Use and Care Guide for reinstalling shipping brace and shipping plug.
39239
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
5
Installation
C
H

Step 3: Connect Fill Hoses

NOTE: Refer to section on Water Supply Requirements before connecting fill hoses.
Turn on the water supply faucets and flush the lines for approximately two minutes to remove any foreign materials that could clog the screens in the water mixing valve.
NOTE: When installing in newly constructed or renovated building, it is very important to flush the lines since build-up may have occurred during construction.
Remove the two plain rubber washers and two filter screens from accessories bag, and install them according to Figure 4.
NOTE: Check filter screens for debris or damage annually. Clean or replace them if necessary.
IMPORTANT: Thread hose couplings onto valve connections finger-tight, then approximately 1/4 turn with pliers. DO NOT cross thread or overtighten couplings.
1
COLD
HOT
8
7
1 Filter Screen (Screen must be facing
outward)
2 Fill Hose 3 Rubber Washer (Plain) 4 Cold Water Connection 5 Hot Water Connection 6 Install this end of hose to valve connections
at rear of washer.
7 Install this end of hose to water supply
faucet.
8 Faucet
3
2
5
6
4
TLW1988N
Turn water on and check for leaks. If leaks are found, retighten the hose couplings. Continue tightening and rechecking until no leaks are found.

Figure 4

IMPORTANT: Hoses and other natural rubber parts deteriorate after extended use. Hoses may develop cracks, blisters or material wear from the temperature and constant high pressure they are subjected to.
All hoses should be checked on a yearly basis for any visible signs of deterioration. Any hose showing the signs of deterioration listed above should be replaced immediately. All hoses should be replaced every 5 years.
6
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
39239
Installation

Step 4: Connect Drain Hose to Drain Receptacle

Remove the drain hose from its shipping position on the rear of the washer by unhooking the hose from the retainer clamp.
Find the instructions, on the following pages, that are appropriate for your type of drain receptacle (standpipe, high standpipe, low standpipe, sink, wall, or laundry tub). Follow these instructions to properly install the drain hose.
IMPORTANT: Drain receptacle must be capable of handling a minimum of 1-1/4 inch (3.2 cm) outside diameter drain hose.
12
Standpipe Installation:
Place the hose into the standpipe.
Remove the beaded tie-down strap from accessories bag and place around standpipe and drain hose, approximately 12 inches (30 cm) down from the top of pipe and tighten strap to hold hose to standpipe. This will prevent the drain hose from dislodging from drain receptacle during use.
IMPORTANT: To prevent siphoning, do not place any ribbed portion of the drain hose into the standpipe.
1
2
5
12 in.
(30 cm)
36 in.
(91.44 cm)
RECOMMENDED
HEIGHT
1 Retainer Clamp 2 Standpipe Adapter

Figure 5

W324I
4
1 Ribbed Portion of Drain Hose 2 Standpipe Adapter 3 Tie-Down Strap 4 Standpipe 2 in. (5.08 cm) or 1-1/2 in. (4 cm)
Diameter
5 Drain Hose Sleeve
3
TLW1961N
TLW1961N

Figure 6

39239
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
7
Installation
High Standpipe Installation:
Place the hose into the standpipe. Remove the beaded tie-down strap from accessories bag and place around standpipe and drain hose, approximately 12 inches (30 cm) down from the top of pipe and tighten strap to hold hose to standpipe. This will prevent the drain hose from dislodging from drain receptacle during use.
1
4
3
TLW1962N
Low Standpipe Installation:
No. 562P3 Siphon Break Kit is required for this type of installation. This kit is available (as optional equipment at extra cost) through an authorized dealer or parts distributor. Installation instructions are supplied with the kit.
1
3
W512I
2
W512I
1 562P3 Siphon Break Kit 2 Standpipe 3 Drain Hose
2
1 Drain Hose 2 Standpipe (Standpipes higher than
4 feet [122 cm] are not recommended)
3 Tie-Down Strap 4 Standpipe Adapter

Figure 7

TLW1962N

Figure 8

8
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
39239
Installation
Sink Installation:
For this type of installation, use the beaded tie-down strap (supplied in accessories bag), or use a large wire tie (available from your local hardware store) and secure the drain hose to the cabinet top hinge. Refer to Figure 9. This will prevent the drain hose from dislodging during use.
It is recommended to leave the standpipe adapter on the drain hose for this type of installation.
1
2
In the Wall Installation:
For installations of this type, the drain hose MUST be secured to one of the fill hoses using the beaded tie­down strap from accessories bag.
NOTE: End of drain hose must not be below height of cabinet top.
1
2
W329I
1 Tie-Down Strap (Tape if necessary) 2 Standpipe Adapter
3
1 Drain Hose 2 Tie-Down Strap or Wire Tie 3 Cabinet Top Hinge

Figure 9

TLW1963N

Figure 10

39239
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
9
Installation
Laundry Tub Installation:
For this type of installation, the drain hose MUST be secured to the stationary tub to prevent hose from dislodging during use. Use the beaded tie-down strap (supplied in accessories bag) to secure hose.
It is recommended to leave the standpipe adapter on the drain hose for this type of installation.
1
TLW1964N
1 Tie-Down Strap (Tape if necessary)

Step 5: Position and Level the Washer

Position washer so it has sufficient clearance for installation and servicing.
Place rubber feet on all four leveling legs.
Place washer in position on a clean, dry, and reasonably firm floor. Installing the washer on any type of carpeting is not recommended.
Loosen 7/8 inch locknuts and adjust the two front leveling legs. Once adjusted, tilt the unit forward on front legs and lower back down into position to set the rear self-leveling legs.
Washer must not rock. After washer is at desired height, tighten locknuts securely against bottom of washer base. If these locknuts are not tight, washer will not remain stationary during operation.
Improper installation or flexing of a weak floor will cause excessive vibration.
Do not slide washer across floor once the leveling legs have been extended, as legs and base could become damaged.
Verify that washer doesn’t rock.

Figure 11

1
5
2
4
3
W179I
1 Level 2 Locknut 3 Leveling Leg 4 Rubber Cup 5 Washer Base
10

Figure 12

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
39239
Installation

Step 6: Plug in the Washer

Refer to section on Electrical Requirements and plug in the washer.
D254I
D254I
Figure 13

Step 7: Add Water to the Washer

To prevent damage to pump, do not run washer before adding at least one quart water to the tub. If the washer is run before any water is added, the pump seal may overheat causing the pump to leak. Once installed, the water retained in the drain system from the previous cycle will provide sufficient cooling to prevent pump seal damage.

Step 8: Check Lid Switch

Washer should stop agitating and spinning when lid is opened.
W376IE0A
W376I
Figure 15

Step 9: Check Installation

Refer to Installer Checklist on the back cover of this manual and make sure that washer is installed correctly.
NOTE: The agitator should not be removed except for service. The washtub is designed to be self­cleaning.
W391I
W391I
Figure 14
39239
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
11
Installation
Electrical Requirements
120 Volt, 60 Hertz with 3-Prong Grounding Plug
NOTE: The wiring diagram is located in the control hood.
WARNING
To reduce the risk of fire, electric shock or personal injury, all wiring and grounding MUST conform with the latest edition of the National Electrical Code, ANSI/NFPA 70, and such local regulations as might apply. It is the customer’s responsibility to have the wiring, fuses and circuit breakers checked by a qualified electrician to make sure your home has adequate electrical power to operate the washer.
W229
WARNING
Improper connection of the equipment­grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the washer is properly grounded.
Do not modify the plug provided with the washer — if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
NOTE: Have a qualified electrician check the polarity of the wall receptacle. If a voltage reading is measured other than that illustrated, the qualified electrician should correct the problem.
2
1
W216
3

DO NOT OVERLOAD CIRCUITS DO NOT USE ADAPTER DO NOT USE AN EXTENSION CORD

Figure 16

D009I
D009I

Grounding Instructions

The washer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. The washer is equipped with a cord having an equipment-grounding conductor and a three-prong grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
120 ± 12
V. A. C .
5
120 ± 12
V.A.C.
4
STANDARD 120 VOLT, 60 HERTZ, 3 WIRE
EFFECTIVELY GROUNDED CIRCUIT
1 L1 2 Ground 3 Neutral Side 4 Round Grounding Prong 5 Neutral

Figure 17

0 V.A.C.
D090I
12
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
39239
Installation
C
H
Water Supply Requirements
WARNING
Under certain conditions, hydrogen gas may be produced in a hot water system that has not been used for two weeks or more. HYDROGEN GAS IS EXPLOSIVE. If the hot water system has not been used for such a period and before using the washer, turn on all hot water faucets and let the water flow from each for several minutes. This will release any accumulated hydrogen gas. THE GAS IS FLAMMABLE, DO NOT SMOKE OR USE AN OPEN FLAME DURING THIS TIME.
W029
NOTE: Water supply faucets must fit standard 3/4 inch (19.1 mm) female garden hose couplings. DO NOT USE SLIP-ON OR CLAMP-ON CONNECTIONS.
NOTE: Water supply faucets should be readily accessible to permit turning them off when washer is not being used.

Water Temperature

Cold:
Recommended cold water temperature is 50° to 75° Fahrenheit (10° to 24° Celsius).
Hot:
Recommended hot water temperature is 140° to 150° Fahrenheit (60° to 66° Celsius).
Warm :
Mixture of hot and cold water. (Warm water temperature is dependent upon the water temperature and the pressure of both the hot and cold water supply lines.)
IMPORTANT: Turn off water supply faucets after check-out and demonstration. Owner should turn off water supply whenever there will be an extended period of non-use.
NOTE: Longer fill hoses are available (as optional equipment at extra cost) if the hoses (supplied with the washer) are not long enough for the installation. Order hoses as follows:
No. 20617 Fill Hose 8 feet (2.44 m) No. 20618 Fill Hose 10 feet (3.05 m)
1
2
1 Water Supply Faucets 2 Cold Water Connection 3 Hot Water Connection 4 Fill Hoses

Figure 18

Water Pressure

Pressure must be a minimum of 20 to 120 pounds per
WATER MIXING
VALV E
34
W187I
square inch (138 to a maximum of 827 kPa) static pressure measured at the faucet.
NOTE: Water pressure under 20 pounds per square inch (138 kPa) will cause an extended fill time in the washer.
39239
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
13
Installation

Risers

Risers (or air cushions) may have to be installed if the pipes knock or pound when flow of water stops. The risers are more efficient when installed as close as possible to the water supply faucets. Refer to Figure 19.
1
2
1 Risers (Air cushions) 2 Water Supply Faucets

Figure 19

W005I
W005I
14
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
39239

Installer Checklist

C
H

Fast Track for Installing the Washer

(Refer to the manual for more detailed information)

• Remove the Shipping Brace and Shipping Plug.
CHECK
• Wipe Out Inside of Washtub.
CHECK
TLW521N
W371IE0B
W371I
• Position and Level the Washer.
CHECK
• Plug in the Washer.
CHECK
LEVEL
W316I
D255I
W316I
D254I
D254IE2A
• Connect Fill Hoses.
CHECK
• Connect Drain Hose to Drain Receptacle.
CHECK
COLD
HOT
TLW1988N
TLW1988N
• Add Water to the Washer.
W391I
W391I
CHECK
• Check Lid Switch.
CHECK
W376I
W376IE0A
W315IE0A
W315IE0A
Loading...