Alliance Laundry Systems DT0220SRG, DC0220SFG, DC0220SRG, DT0220SFG, JC0220SFG Troubleshooting Manual

...
Drying Tumblers
Refer to Page 3 for Model Identification
H I G H T E M P
S T AR
T
L O W T E M
P M E D T E M P
N
O
H
E
A
T
C
25
1
S E L
2
E
C T
T
I
E
N
M
S E
P
R C O I N
1
S E L
2
E
C T
T
I
E
N
M
S E
P
3
R
T C O
P
H
I
U
N
I
S
G
H
H
S
T
T
E
A
M
R
P
T
ST AR
T
L O W T E M
P M E D T E M
3
T
P U S H S T A R
T
P
N
O
H
E
A
T
C
25
Troubleshooting
T478C
T478C
Keep These Instructions for Future Reference.
(If this machine changes ownership, this manual must accompany machine.)
www.comlaundry.com
T477C
T477C
Part No. 70172201
November 2001
Table of
Contents
Introduction......................................................................................... 3
Model Identification ............................................................................. 3
Theory of Operation of Instant Electronic Ignition .............................. 3
Safety Information.............................................................................. 5
Cannot Perform Infrared (IR) Communication.............................. 7
Coins Ignored When Entered ............................................................ 9
Control Display ................................................................................... 11
Door Open Light “On” ......................................................................... 11
No Visible Display – OPL Microprocessor Models............................. 12
No Visible Display – Power On ........................................................... 13
Will Not Start ...................................................................................... 15
Electric.................................................................................................. 15
Manual Timer................................................................................... 15
Rotary Coin Drop............................................................................. 16
Gas ........................................................................................................ 18
Manual Timer................................................................................... 18
Rotary Coin Drop............................................................................. 19
Steam .................................................................................................... 21
Manual Timer................................................................................... 21
Rotary Coin Drop............................................................................. 22
Will Not Start/Continue Running ..................................................... 25
EDC Control ......................................................................................... 25
OPL Microprocessor Control ............................................................... 28
Will Not Run ....................................................................................... 31
Electric.................................................................................................. 31
Manual Timer................................................................................... 31
Rotary Coin Drop............................................................................. 34
Gas ........................................................................................................ 37
Manual Timer................................................................................... 37
Rotary Coin Drop............................................................................. 39
Steam .................................................................................................... 41
Manual Timer................................................................................... 41
Rotary Coin Drop............................................................................. 43
Will Not Heat....................................................................................... 45
Electric.................................................................................................. 45
Manual Timer................................................................................... 45
Rotary Coin Drop............................................................................. 47
Rotary Coin Drop (with and without time delay board) ................. 49
Electric/Gas........................................................................................... 51
OPL Microprocessor........................................................................ 51
Gas ........................................................................................................ 54
EDC Models..................................................................................... 54
Manual Timer................................................................................... 56
Rotary Coin Drop............................................................................. 58
© Copyright 2001, Alliance Laundry Systems LLC All rights reserved. No part of the contents of this book may be reproduced or transmitted in any form or by any
means without the expressed written consent of the publisher.
70172201
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
1
Steam .................................................................................................... 60
EDC Models..................................................................................... 60
Manual Timer................................................................................... 62
OPL Microprocessor........................................................................ 64
Rotary Coin Drop............................................................................. 67
2
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70172201

Introduction

Model Identification

Information in this manual is applicable to these tumbler models:
Gas Steam/Thermal Oil Electric
25 Pound
(220 Liter)
30 Pound
(270 Liter)
30 Pound
Stacked
(300 Liter)
35 Pound
(350 Liter)
DC0220SFG DC0220SRG DT0220SFG DT0220SRG
JC0220SFG JC0220SRG
DC0270SFG DC0270SRG DT0270SFG DT0270SRG
JC0270SFG JC0270SRG
DC0300DFG DC0300DRG DT0300DFG DT0300DRG
JC0300DFG
JC0300DRG
JT0300DFG
AT0350SRG DC0350SFG
DC0350SRG
DT0350SFG
DT0350SRG
JC0350SFG
JC0350SRG
JT0220SFG
JT0220SRG SC0220SFG SC0220SRG ST0220SFG ST0220SRG
JT0270SFG JT0270SRG SC0270SFG SC0270SRG ST0270SFG ST0270SRG
JT0300DRG
NT0300DRG
SC0300DFG
SC0300DRG
ST0300DFG ST0300DRG
JT0350SFG JT0350SRG SC0350SFG
SC0350SRG
ST0350SFG
ST0350SRG
DC0220SSL DT0220SSH DT0220SSL
JC0220SSL JT0220SSH
DC0270SSL DT0270SSH DT0270SSL
JC0270SSL JT0270SSH
DC0300DSL DT0300DSH DT0300DSL
JC0300DSL
JT0300DSH
AT0350SSL
DC0350SSL
DT0350SSH
DT0350SSL
JC0350SSL
JT0220SSL SC0220SSL ST0220SSH ST0220SSL
JT0270SSL SC0270SSL ST0270SSH ST0270SSL
JT0300DSL
SC0300DSL ST0300DSH ST0300DSL
JT0350SSH
JT0350SSL SC0350SSL
ST0350SSH
ST3050SSL
DC0220SEL DT0220SEL
JC0220SEL
DC0270SEL DT0270SEL
JC0270SEL
DC0300DEL DT0300DEL
JC0300DEL
DC0350SEL DT0350SEL
JC0350SEL
JT0220SEL SC0220SEL ST0220SEL
JT0270SEL SC0270SEL ST0270SEL
JT0300DEL
SC0300DEL ST0300DEL
JT0350SEL SC0350SEL ST0350SEL
Theory of Operation of Instant Electronic Ignition
IMPORTANT: The Non-CE Marked Instant Electronic Ignition system will attempt to light the gas by sparking for approximately 15 seconds. If gas ignition does not take place within approximately 15 seconds, the Instant Electronic Ignition control will go into safety lockout and the valve will no longer open until Instant Electronic Ignition control is reset. To reset Instant Electronic Ignition control, remove power from control by opening and closing the tumbler door. If condition persists, check that the gas shut-off valve is in “on” position and that the gas service is properly connected.
70172201
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
If condition persists:
1. Check resistance of high tension lead (approximately 1000 ohms/inch), and replace if not within resistance range.
2. Check voltage present at valve.
3. Check that machine is properly grounded.
4. Check the gap between igniter and burner tube (gap should be 1/4-3/8 inch).
5. Check that burner ports are not blocked or plugged under the igniter.
3

Safety Information

DANGER indicates the presence of a hazard that will cause severe personal injury, death, or substantial property damage if the danger is ignored.
DANGER
WARNING indicates the presence of a hazard that can cause severe personal injury, death, or substantial property damage if the warning is ignored.
WARNING
CAUTION indicates the presence of a hazard that will or can cause minor personal injury or property damage if the caution is ignored.
CAUTION
Precautionary statements (DANGER,WARNING,” and “CAUTION”), followed by
specific instructions, are found in this manual and on machine decals. These precautions are intended for the personal safety of the operator, user, servicer, and those maintaining the machine.
IMPORTANT: The word “IMPORTANT is used to inform the reader of specific procedures where minor machine damage will occur if the procedure is not followed.
NOTE: The word “NOTE” is used to communicate installation, operation, maintenance or servicing information that is important but not hazard related.
WARNING
Failure to install, maintain, and/or operate this machine according to manufacturer’s instructions may result in conditions which can produce serious injury, death and/or property damage.
W051
NOTE: The WARNINGS and IMPORTANT instructions appearing in this manual are not meant to cover all possible conditions and situations that may occur. It must be understood that common sense, caution and carefulness are factors which CANNOT be built into this tumbler. These factors MUST BE supplied by the person(s) installing, maintaining or operating the tumbler.
Additional precautionary statements (“IMPORTANT and NOTE) are followed by specific instructions.
Always contact your dealer, distributor, service agent or the manufacturer on any problems or conditions you do not understand.
70172201
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
5
Cannot Perform Infrared (IR)
Communication
Single and stacked.
Gas and electric heat.
Attempt to
communicate with
the electronic
control from the
micro wand.
Is there a response of
any kind from the
electronic control?
YES
Single and three phase
supply.
NO
Aim micro wand
closer and try again.
Does the control
respond?
YES
NO
Check the following:
- low battery on micro wand
- is the IR window covered or blocked on the control.
- if needed replace the EDC
- is the IR cap properly attached
control
to the micro wand.
Does the electronic
control display "E:OF"
or "-C-"?
"E:OF"
Check the following:
- IR communication disabled by manual programming.
- Is the IR window on the control covered or blocked.
- if needed, change EDC board.
"-C-"
Communication
sequence checks
out.
T027D
T027D
70172201
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
7

Coins Ignored When Entered

Single and stacked units. Gas and electric heat. Single and three
phase voltage.
Start coin drop
diagnostic tests.
Does the display on the
EDC control increment
properly?
NO
Is connector H2 firmly
seated in its
receptacle?
YES
Is the 3 pin connector
between coin drop and
control connected
correctly?
YES
Are wires exiting coin
drop optical sensor cracked or broken?
YES
NO
NO
YES
Exit diagnostic
testing and reset
control. (Prompting
for vend price)
Reconnect and run
diagnostic test
again.
Reconnect and run
diagnostic test
again.
Replace coin drop.
70172201
NO
Replace coin drop.
If problem still
exists then replace
the EDC control.
T026D
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
T026D
9
Door Open Light “On”

Control Display

Is there voltage at "H4-6 on the EDC
control?
NO
Is there power supplied
to the unit?
YES
Is there voltage to input
of primary fuses?
YES
Is there voltage to
output side of the
primary fuses?
YES
Single and stacked
units. Gas and electric
heat. Single and three
phase supply.
YES
NO
NO
NO
Reference voltage
checks to transformer
Replace EDC
Control.
Plug unit in and
run it.
Correct wiring between primary fuses and power
supply.
Replace primary
fuse(s).
neutral.
Is there voltage at
the input of the
secondary fuse?
YES
Is there voltage to
output side of
secondary fuse?
YES
Is there voltage to
N.O. of door
switch?
YES
With door closed is
there voltage to
COM of door
switch?
YES
NO
NO
NO
NO
Correct wiring
between secondary
fuse and
transformer.
Replace secondary
fuse.
Correct wiring
between N.O. and
output of secondary
fuse.
Check for proper
function of door
switch replace if
necessary.
70172201
Is there voltage across
terminals "1" & "2" of transformer primary?
YES
Is there voltage across
terminals "2" & "3" of
transformer
secondary?
YES
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
NO
NO
Correct wiring between primary
fuses and
transformer.
Replace
transformer.
Is there voltage to
N.O. of lint drawer
switch?
YES
Is there voltage to
COM of lint drawer
switch with lint
panel closed?
YES
Correct wiring
between "H4-6" of
EDC control and
COM of lint drawer
switch.
NO
NO
Correct wiring between N.O. on lint drawer and COM on
door switch.
Check for proper
operation replace if
necessary.
T028D
T028D
11
Control Display
No Visible Display – OPL Microprocessor Models
Gas, steam
and electric heat.
Single and three
phase supply.
Is there voltage
supplied to the unit?
YES
Note: Reference voltage to
Is there voltage to the
input side of the primary fuse(s)?
YES
Is there voltage to the
output side of the
primary fuse(s)?
YES
Is there voltage
to primary side of
the transformer
terminal "1"?
NO
supply neutral.
NO
NO
NO
Connect supply
voltage and run unit.
Correct wiring between primary fuse and supply.
Replace primary
fuse.
Correct wiring
between transformer
and primary fuse.
Is there voltage across
fuse on OPL Micro?
YES
Replace fuse.
NO
Replace OPL Micro.
YES
Is there voltage across "1" & "4" of transformer
secondary?
YES
Is there voltage across
terminals "H3-3" &
"H3-4" on OPL Micro?
YES
NO
NO
Replace transformer
Correct wiring
between OPL Micro
and transformer
secondary.
T007D
T007D
12
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70172201
No Visible Display – Power On
Single and stacked units. Gas and electric heat. Single and three
phase supply.
Is there voltage across
"H4-2 & H4-5" on the
EDC control?
Replace EDC
Control.
Is there voltage at
the input of the
secondary fuse?
NOYES
Control Display
Correct wiring
between secondary
fuse and
transformer.
NO
Is there power supplied
to the unit?
YES
Is there voltage to input
of primary fuses?
YES
Is there voltage to output side of the
primary fuses?
YES
Is there voltage across
terminals "1" & "2" of transformer primary?
NO
NO
NO
NO
Plug unit in and run
it.
Correct wiring between primary fuses and power
supply.
Replace primary
fuse(s).
Correct wiring between primary
fuse and
transformer.
YES
Is there voltage to
output side of
secondary fuse?
YES
Correct wiring
between "H4-2" and
secondary fuse.
NO
Replace secondary
fuse.
70172201
YES
Is there voltage across
terminals "2" & "3" of
transformer secondary?
YES
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
NO
Replace
transformer.
T025D
T025D
13
Electric
Manual Timer
Manual Timer, with and without Time Delay Board, Single and

Will Not Start

Stacked units, Single and 3 Phase power supply.
Is there power supply voltage coming to the
tumbler?
YES
Is there
voltage at the primary side
of the transformer at
terminals 1 and 2?
YES
Is
there voltage at the
secondary side of the
transformer at terminal
2 and 3?
YES
Is there voltage to the
output side of the
secondary fuse?
NOTE: White wires are
YES
transformer "neutral"
Is there voltage to the "N.O." terminal of the
door switch?
NO
NO
NO
NO
YES
Connect power
and run the cycle.
Change the primary
fuse to the transformer.
Replace the transformer.
Change the
secondary fuse.
With door closed Is
there voltage at "COM"
of the door switch?
Still no voltage
For stacked units.
Correct the wiring
NO
secondary fuse and
the transformer.
Correct wiring
between power
supply and
transformer.
Correct wiring
between upper and
lower pocket.
between the
YES
Is there voltage to the
"COM" of the lint panel
switch?
YES
70172201
NO
Correct the wiring between the door
switch and the
secondary fuse.
With lint panel
closed is there votlage to
"N.O." terminal of the
liint panel switch?
NO
YES
Replace lint
panel switch.
NO
Check for proper
operation,
replace the door
switch if
necessary.
Refer to NO MOTOR RUN (run circuit.)
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
NO
Correct wiring
between lint panel
switch and door
switch.
T050D
T050D
15
Will Not Start
Electric
Rotary Coin Drop (Sheet 1 of 2)
Coin Drop with and without Time Delay Boards.
Single and Stacked units. Single and 3 phase
power supply.
Is there power supply
voltage coming to the
unit?
YES
Is there voltage at the
primary side of the
transformer at terminals
"1" & "2"?
YES
Is there voltage at the secondary side of the
transformer at terminal
"2" and "3"?
YES
Is there voltage to the
output side of the
secondary fuse?
YES
Note: Reference voltage
to transformer neutral.
(White wire)
Is there voltage to "N.C." terminal of
switch "A" on rotary
coin drop?
YES
Is the unit equipped
with time delay
boards?
NO
Note: The following
checks are made with
the vend price satisfied.
Is there voltage on the
"COM" terminal of switch
"A"?
NO
NO
NO
NO
NO
YES
NO
Connect power to
the unit and run
cycle.
Is the primary
fuse good?
YES
Correct wiring
between transformer
and power supply.
Replace the transformer.
Is the
secondary
fuse good?
YES
Correct wiring
between secondary
of transformer and
fuse.
Correct wiring between rotary
coin drop and
secondary fuse.
Continued on next
page at step 1.
Replace switch "A".
NO
NO
Replace fuse and
run
machine.
Replace
fuse and
run
machine.
Is there voltage across coinmeter timer motor?
YES
Does the coinmeter
timer motor
advance?
YES
Is there voltage at
N.O. terminal of the
door switch?
YES
With the door
closed is there
voltage across the
door switch?
NO
Is there voltage to
the N.O. terminal of
the lint panel
switch?
YES
With the lint
panel closed is there
voltage across the
lint panel switch?
NO
Continued on next
page at step 2.
Step 3 continuation.
NO
NO
NO
YES
NO
YES
Correct wiring
between
coinmeter timer
motor and COM
on switch "A".
Replace coinmeter
timer motor.
Correct wiring between N.O on door switch and
COM on switch"A".
Check door switch for proper operation, replace if necessary.
Correct wiring between N.O. on the lint panel switch and
COM of door switch.
Check lint panel
switch for proper
operation and
replace if necessary.
16
YES
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
T075D
T075D
70172201
Electric
Rotary Coin Drop (Sheet 2 of 2)
Will Not Start
STEP 1
Is there voltage to
"H1-2" on TMR1
board?
YES
Note: Following tests
are conducted with
vend price satisfied.
With vend price
satisfied is there
voltage across "N.C." &
COM of switch "A"?
NO
Is there voltage across
the timer motor?
YES
Does Coinmeter Timer
Motor advance?
YES
NO
YES
NO
NO
Correct wiring
between
"H1-2" and
output of
secondary
fuse.
Replace Switch "A"
Correct wiring between timer
motor and COM on
switch "A"
Replace Timer
Motor.
3 phase
STEP 2
Is there voltage at
"2A" of the start
switch?
YES
Does the unit have single phase or three phase power supply?
Single phase
Is there voltage at
terminal "7" of the
motor relay?
YES
NO
between "2A" of start
NO
Refer to NO
MOTOR RUN
(run circuit).
Correct wiring
switch and COM of
lint panel switch.
Correct wiring
between "7" of
motor relay and COM
of lint panel switch.
Is there voltage across
"H1-6" & "H1-8" of
TMR1?
YES
Is there voltage across
"H1-2" & "H1-3" of
TMR1"?
NO
Is there voltage to N.O.
of door switch?
YES
Continue at step 3 on previous page.
NO
YES
NO
Correct wiring
between "H1-6" and
COM on switch "A"
Replace TMR1.
Correct wiring between N.O. of door switch and "H1-3" of TMR1.
Is there voltage at
terminal "14" of the
motor control relay?
YES
Refer to NO
MOTOR RUN (Run
Circuit).
NO
Correct wiring to
terminal "14" of
motor control
relay.
T076D
T076D
70172201
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
17
Will Not Start
Gas
Manual Timer
No motor run (start circuit) Manual Tumblers. Single and stacked units
with and without time delay. GAS UNITS
Is there power supply voltage coming to the
tumbler?
YES
Is there voltage at the
primary side of the
transformer at
terminals 1 and 2?
YES
Is there voltage at the secondary side of the
transformer at terminal
2 and 3?
YES
Is there voltage to the
output side of the
secondary fuse?
NO
NO
NO
NO
Connect power
and run the cycle.
Change the primary
fuse to the
transformer.
Replace the transformer.
Change the
secondary fuse.
Still no voltage
For stacked units.
Correct the wiring
NO
secondary fuse and
the transformer
Correct wiring
between power
supply and
transformer.
Correct wiring
between upper and
lower pocket.
between the
.
NOTE: White wires are
YES
Is there voltage to the input side of the door
switch?
NO
Correct the wiring between the door
switch and the
secondary fuse.
Is there voltage to the output side of the lint
panel switch?
NO
transformer "neutral"
YES
YES
Is there voltage to the
output side of the door
switch?
Replace the door switch.
Replace lint
panel switch.
NO
YES
Refer to NO
MOTOR RUN
(run circuit).
Is there voltage to the
input side of the lint
panel switch?
NO
Correct wiring
between lint panel
switch and door
switch.
YES
T041D
T041D
18
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70172201
Gas
Rotary Coin Drop (Sheet 1 of 2)
Single &
Stacked Tumblers
with and without time delay
Gas units.
Will Not Start
Is there power supply voltage coming to the
unit?
YES
Is there voltage at the primary side of the transformer at terminals
"1" & "2"?
YES
Is there voltage at the secondary side of the
transformer at terminal
"2" and "3"?
YES
Is there voltage to the
output side of the
secondary fuse?
YES
Note: Reference voltage to
transformer neutral.
Is there voltage to "N.C." terminal of
switch "A" on rotary
coin drop?
YES
NO
NO
NO
NO
(White wire)
NO
Connect power to
the unit and run
cycle.
Is the primary
fuse good?
YES
Correct wiring
between transformer
and power supply.
Replace the transformer.
Is the
secondary
fuse good?
YES
Correct wiring
between secondary
of transformer and
fuse.
Correct wiring between rotary coin drop and secondary
fuse.
NO
NO
Replace fuse and
run
machine.
Replace
fuse and
run
machine.
Is there voltage across
coinmeter timer motor?
YES
Does the coinmeter
timer motor
advance?
YES
Is there voltage at
N.O. terminal of the
door switch?
YES
With the door
closed is there
voltage across the
door switch?
NO
Is there voltage to
the N.O. terminal of
the lint panel
switch?
YES
NO
NO
NO
YES
NO
Correct wiring
between
coinmeter timer
motor and COM
on switch "A".
Replace coinmeter
timer motor.
Correct wiring
between N.O on
door switch and
COM on switch"A".
Check door switch for proper operation, replace if necessary.
Correct wiring between N.O. on the lint panel switch and
COM of door switch.
70172201
Is the unit equipped
with time delay
boards?
NO
Note: The following
checks are made with
the vend price satisfied.
Is there voltage on the
COM terminal of switch
"A"?
YES
With the lint
YES
NO
Continued on next
page at step 1.
Replace switch "A".
panel closed is there
voltage across the lint
panel switch?
NO
Continued on next
page at step 2.
Step 3 continuation.
YES
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Check lint panel switch for proper
operation and replace if necessary.
T086D
T086D
19
Will Not Start
Gas
Rotary Coin Drop (Sheet 2 of 2)
STEP 1
Is there voltage to
"H1-2" on TMR1
board?
YES
Note: Following tests
are conducted with
vend price satisfied.
With vend price
satisfied is there
voltage across "N.C." &
COM of switch "A"?
NO
Is there voltage across
the timer motor?
YES
Does Coinmeter Timer
Motor advance?
YES
NO
YES
NO
NO
Correct wiring
between
"H1-2" and
output of
secondary
fuse.
Replace Switch "A"
Correct wiring between timer motor and COM on switch
"A"
Replace Timer
Motor.
STEP 2
Is there voltage at
2A of the start
switch?
YES
Is there voltage at
terminal 7 of the
motor relay?
YES
NO
NO
Refer to NO
MOTOR RUN
(run circuit).
Correct wiring between 2A of start switch and COM of
lint panel switch.
Correct wiring
between 7 of motor
relay and COM of
lint panel switch.
Is there voltage across
"H1-6" & "H1-8" of
TMR1?
YES
Is there voltage across
"H1-2" & "H1-3" of
TMR1?
NO
Is there voltage to N.O.
of door switch?
YES
Continue at step 3 on previous page.
NO
YES
NO
Correct wiring
between "H1-6" and
COM on switch "A"
Replace TMR1.
Correct wiring between N.O. of door switch and "H1-3" of TMR1.
T087D
T087D
20
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70172201
Steam
Manual Timer
Single and stacked units with and without
time delay boards. Steam Heat.
Will Not Start
Is there power supply voltage coming to the
tumbler?
YES
Is there voltage at the
primary side of the
transformer at
terminals 1 and 2?
YES
Is there voltage at the secondary side of the
transformer at terminal
2 and 3?
YES
Is there voltage to the
output side of the
secondary fuse?
NOTE: White wires are
YES
transformer "neutral"
NO
NO
NO
NO
Connect power
and run the cycle.
Change the primary
fuse to the
transformer
Replace the transformer.
Change the
secondary fuse.
Still no voltage
For stacked units.
Correct the wiring
NO
secondary fuse and
the transformer.
Correct wiring
between power
supply and
transformer.
Correct wiring
between upper and
lower pocket.
between the
70172201
Is there voltage to the
N.O. terminal of the
door switch?
NO
Correct the wiring
between the door
switch and the secondary fuse
Is there voltage to the
N.O. terminal of the
lint panel switch?
NO
YES
YES
Is there voltage to the
COM terminal of the
door switch?
Replace the door switch.
Replace lint
panel switch.
NO
YES
Refer to NO MOTOR RUN (run circuit) .
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Is there voltage to the
COM terminal of the
lint panel switch?
NO
Correct wiring
between lint panel
switch and door
switch.
YES
T016D
T016D
21
Will Not Start
Steam
Rotary Coin Drop (Sheet 1 of 2)
Single &
Stacked Tumblers
with and without time delay
Steam units.
Is there power supply
to the unit?
YES
Is there voltage
at the primary side of the
transformer at terminals
"1" & "2"?
YES
Is there voltage
at the secondary side of the
transformer at terminal
"2" and "3"?
YES
Is there voltage to the
output side of the
secondary fuse?
YES
Note: Reference voltage to
transformer neutral.
Is there voltage to
"N.C." terminal of
switch "A" on rotary
coin drop?
YES
NO
NO
NO
NO
(White wire)
NO
Connect power to
the unit and run
cycle.
Is the primary
fuse good?
YES
Correct wiring
between transformer
and power supply.
Replace the transformer.
Is the
secondary
fuse good?
YES
Correct wiring
between secondary
of transformer and
fuse.
Correct wiring
between rotary coin
drop and secondary
fuse.
NO
NO
Replace fuse and
run
machine.
Replace fuse and
run
machine.
Is there voltage across
coinmeter timer motor?
YES
Does the coinmeter
timer motor
advance?
YES
Is there voltage at
N.O. terminal of the
door switch?
YES
With the door
closed is there
voltage across the
door switch?
NO
Is there voltage to
the N.O. terminal of
the lint panel
switch?
YES
NO
NO
NO
YES
NO
Correct wiring
between coinmeter timer motor and COM
on switch "A".
Replace coinmeter
timer motor.
Correct wiring
between N.O on
door switch and
COM on switch"A".
Check door switch for proper operation, replace if necessary.
Correct wiring between N.O. on the lint panel switch and COM of door switch.
22
Is the unit equipped
with time delay
boards?
NO
Note: The following
checks are made with
the vend price satisfied.
Is there voltage on the
COM terminal of switch
"A"?
YES
With the lint
YES
NO
Continued on next
page column 1.
Replace switch "A".
panel closed is there
voltage across the
lint panel switch?
NO
Continued on next
page column 2.
Step 3 continuation.
YES
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Check lint panel
switch for proper
operation and
replace if necessary.
T062D
T062D
70172201
Steam
Rotary Coin Drop (Sheet 2 of 2)
Will Not Start
COLUMN 1
Is there voltage to
"H1-2" on TMR1
board?
YES
Note: Following tests
vend price satisfied.
With vend price
satisfied is there
voltage across "N.C." &
COM of switch "A"?
NO
Is there voltage across
the timer motor?
YES
Does Coinmeter Timer
Motor advance?
YES
NO
are conducted with
YES
NO
NO
Correct wiring
between
"H1-2" and
output of
secondary
fuse.
Replace Switch "A"
Correct wiring
between timer motor
and COM on switch
"A"
Replace Timer
Motor.
COLUMN 2
Is there voltage at
"2A" of the start
switch?
YES
Is there voltage at
terminal "7" of the
motor relay?
YES
NO
NO
Refer to NO
MOTOR RUN
(run circuit).
Correct wiring
between "2A" of
start switch and COM
of lint panel switch.
Correct wiring
between "7" of
motor relay and COM
of lint panel switch.
Is there voltage across
"H1-6" & "H1-8" of
TMR1?
YES
Is there voltage across
"H1-2" & "H1-3" of
TMR1"?
NO
Is there voltage to N.O.
of door switch?
YES
Continue at step 3
on previous page.
NO
YES
NO
Correct wiring
between "H1-6" and
COM on switch "A"
Replace TMR1.
Correct wiring
between N.O. of
door switch and "H1-3" of TMR1.
T063D
T063D
70172201
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
23