Alliance Laundry Systems CA120L, CU120N, DR120G2-BA120L, DR120G2-BK120N, DR120G2-BA120N Installation Operation & Maintenance

...
Tumble Dryers
120 Pound (54 Kilogram) Capacity 170 Pound (77 Kilogram) Capacity 200 Pound (91 Kilogram) Capacity
Starting Serial No. 0907003062
Refer to Page 6 for Model Identification
Installation/Operation/Maintenance
Original Instructions Keep These Instructions for Future Reference.
(If this machine changes ownership, this manual must accompany machine.)
Part No. 70458101ENR7
January 2014
Front Matter
Front Matter
Installation must conform with local codes or, in the absence of local codes, with: In the U.S.A., installation must conform to the latest edition of the American National Standard Z223.1/ NFPA 54 “National Fuel Gas
Code” and Standard ANSI/NFPA 70 “National Electric Code.” In Canada, installation must comply with Standards CAN/CSA-B149.1 or Natural Gas and Propane Installation Code and CSA C22.1,
latest edition, Canadian Electric Code, Part I. In Australia and New Zealand, installation must comply with the Gas Installations Standard AS/NZS 5601 Part 1: General
Installations.
WARNING
FOR YOUR SAFETY, the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury or death.
W033
WARNING
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Clear the room, building or area of all occupants.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
W052
IMPORTANT: Information must be obtained from a local gas supplier on instructions to be followed if the user smells gas. These instructions must be posted in a prominent location. Step-by-step instructions of the above safety information must be posted in a prominent location near the tumble dryer for customer use.
IMPORTANT: The installer must fully test the tumble dryer after installation and demonstrate to the owner how to operate the machine.
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumble dryer before servicing.
Close gas shut-off valve to gas tumble dryer before servicing.
Close steam valve to steam tumble dryer before servicing.
Never start the tumble dryer with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the tumble dryer is properly grounded.
Part No. 70458101ENR7
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 3
W002R1
Front Matter
WARNING
Installation of unit must be performed by a qualified installer.
Install tumble dryer according to manufacturer’s instructions and local codes.
DO NOT install a tumble dryer with flexible plastic venting materials. If flexible metal (foil type) duct is installed, it must be of a specific type identified by the appliance manufacturer as suitable for use with tumble dryer. Refer to section on connecting exhaust system. Flexible venting materials are known to collapse, be easily crushed, and trap lint. These conditions will obstruct tumble dryer airflow and increase the risk of fire.
The following information applies to the state of Massachusetts, USA.
This appliance can only be installed by a Massachusetts licensed plumber or gas fitter.
This appliance must be installed with a 36 inch (91 cm) long flexible gas connector.
A “T-Handle” type gas shut-off valve must be installed in the gas supply line to this appliance.
This appliance must not be installed in a bedroom or bathroom.
W752R1
4
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458101ENR7
Table of Contents
Introduction..........................................................................................8
Model Identification......................................................................................8
Contact Information.....................................................................................10
Safety Information..............................................................................12
Safety Information.......................................................................................12
Important Safety Instructions........................................................................12
Specifications and Dimensions.............................................................14
Specifications and Dimensions.....................................................................14
120 Series Tumble Dryer Dimensions and Exhaust Outlet Locations................16
170 and 200 Series Tumble Dryer Dimensions and Exhaust Outlet
Locations..................................................................................................18
Electric and Gas Connection Locations for Gas Models Through 3/10/13......... 20
Electric and Gas Connection Locations for Gas Models Starting 3/11/13..........21
Electric and Steam Connection Locations for Steam Models Through
3/10/13.....................................................................................................22
Electric and Steam Connection Locations for Steam Models Starting
3/11/13.....................................................................................................24
Electric Connection Location for Electric Models.......................................... 26
Installation..........................................................................................27
Pre-Installation Inspection............................................................................27
Location Requirements................................................................................27
Position and Level the Tumble Dryer........................................................... 29
Fire Suppression System..............................................................................30
Check Local Codes and Permits................................................................30
Water Requirements.................................................................................30
Water Connections...................................................................................30
Electrical Requirements............................................................................32
Auxiliary Alarm...................................................................................... 32
Before Placing Tumble Dryer into Service....................................................32
Required for CE Models Only..................................................................34
Installing CE Gas Drying Tumble Dryer.......................................................34
General Information.................................................................................34
CE Orifices.............................................................................................35
Properties of CE Gases............................................................................ 36
Changing Gas Configuration.....................................................................37
Specific Conversion Procedures................................................................38
Exhaust Requirements........................................................................ 40
©
Copyright 2014, Alliance Laundry Systems LLC All rights reserved. No part of the contents of this book may be reproduced or transmitted in any form or by any means without the expressed written consent of the publisher.
Part No. 70458101ENR7
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 5
Exhaust Requirements................................................................................. 40
Layout........................................................................................................40
Make-Up Air.............................................................................................. 40
Venting.......................................................................................................40
Alternate Venting for 120 Series Tumble Dryers........................................42
Individual Venting...................................................................................42
Manifold Venting.................................................................................... 43
Gas Requirements...............................................................................46
Gas Requirements....................................................................................... 46
Gas Supply Pipe Sizing and Looping............................................................48
High Altitude Orifice Sizing........................................................................ 50
Electrical Requirements...................................................................... 53
Electrical Requirements............................................................................... 53
Wiring Diagram..........................................................................................53
Grounding Instructions................................................................................ 53
For CE Models Only............................................................................... 54
Service/Ground Location..........................................................................54
To Connect Electrical Service To The Tumble Dryer.....................................56
Jumper Configuration Instructions................................................................56
Ferrite Ring Installation...............................................................................56
Electrical Specifications...............................................................................58
Steam Requirements........................................................................... 62
Steam Requirements....................................................................................62
Piping Recommendations.............................................................................66
Installing Steam Trap and Making Condensate Return Connections................. 66
Thermal Oil Prep........................................................................................ 66
Operating Instructions........................................................................ 67
Operating Instructions..................................................................................67
Emergency Stop Button On CE Models........................................................67
Operating Instructions..................................................................................67
Reversing Operation....................................................................................68
Control Instructions.....................................................................................68
Dual Digital Timer Control...................................................................... 68
Electronic OPL Micro Control..................................................................70
LED OPL Control................................................................................... 71
UniLinc Control...................................................................................... 72
DX4 OPL Control................................................................................... 73
Diagnostic Microprocessor Control...........................................................73
DMP OPL Models...................................................................................74
Ignition Control Operation and Troubleshooting for Models Starting
3/11/13.....................................................................................................77
Internal Control Failure............................................................................77
Troubleshooting.......................................................................................77
Proper Electrode Location........................................................................78
Flame Current Measurement.....................................................................78
6
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458101ENR7
Ignition Control Operation for Non-CE Models Through 3/10/13.....................78
Ignition Control Operation for CE Models Through 3/10/13............................79
System Tests...........................................................................................80
Diagnostic LED (DGN LED)/Error Codes.................................................80
Adjustments........................................................................................82
Adjustments................................................................................................82
Gas Burner Air Shutter................................................................................82
Airflow Switch............................................................................................82
Loading Door Switch.................................................................................. 83
Loading Door Catch (120 and 170 Series Models).........................................83
Loading Door Strike (200 Series Models)..................................................... 83
Belt Drive...................................................................................................84
Maintenance........................................................................................86
Daily..........................................................................................................86
Monthly......................................................................................................86
Quarterly.................................................................................................... 86
Bi-Annually................................................................................................86
Annually.....................................................................................................87
Fire Suppression System Maintenance Test...................................................87
Before You Call for Service................................................................ 89
Removing Tumble Dryer from Service................................................90
Disposal of Unit.................................................................................. 91
Part No. 70458101ENR7
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 7
Introduction
Model Identification
Information in this manual is applicable to these models:
Gas Steam/Thermal Oil Electric
Introduction
120 Series CA120L
CA120N CK120N CT120L CT120N CU120L CU120N DR120G2-BA120L DR120G2-BA120N DR120G2-BK120N DR120G2-BT120L DR120G2-BT120N DR120G2-BU120L DR120G2-BU120N HA120L HA120N
HK120N HT120L HT120N HU120L HU120N IPD120G2 IT120L IT120N SA120L SA120N SK120N ST120L ST120N SU120L SU120N UA120L
UA120N UK120N UT120L UT120N UU120L UU120N XT120L XT120N XU120L XU120N YT120L YT120N YU120L YU120N
CT120S CT120T CU120S CU120T DR120S2-BT120S DR120S2-BT120T DR120S2-BU120S DR120S2-BU120T HT120S HT120T HU120S HU120T IPD120S2 IT120S IT120T ST120S
ST120T SU120S SU120T UT120S UT120T UU120S UU120T XT120S XT120T XU120S XU120T YT120S YT120T YU120S YU120T
CT120E CU120E DR120E2-BT120E DR120E2-BU120E HT120E HU120E IT120E ST120E SU120E UT120E UU120E YT120E YU120E
Part No. 70458101ENR7
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 8
Gas Steam/Thermal Oil Electric
Introduction
170 Series CA170L
CA170N CK170N CT170L CT170N CU170L CU170N DR170G2-BA170L DR170G2-BA170N DR170G2-BK170N DR170G2-BT170L DR170G2-BT170N DR170G2-BU170L DR170G2-BU170N HA170L HA170N
HK170N HT170L HT170N HU170L HU170N IPD170G2 IT170L IT170N SA170L SA170N SK170N ST170L ST170N SU170L SU170N UA170L
UA170N UK170N UT170L UT170N UU170L UU170N XT170L XT170N XU170L XU170N YT170L YT170N YU170L YU170N
CT170S CT170T CU170S CU170T DR170S2-BT170S DR170S2-BT170T DR170S2-BU170S DR170S2-BU170T HT170S HT170T HU170S HU170T IPD170S2 IT170S IT170T ST170S
ST170T SU170S SU170T UT170S UT170T UU170S UU170T XT170S XT170T XU170S XU170T YT170S YT170T YU170S YU170T
Not Applicable
200 Series CA200L
CA200N CT200L CT200N CU200L CU200N DR200G2-BA200L DR200G2-BA200N DR200G2-BT200L DR200G2-BT200N DR200G2-BU200L
DR200G2­BU200N
HA200L HA200N HT200L HT200N HU200L HU200N IT200L IT200N SA200L SA200N
Explanation of digit in 6th position of model number:
E = Electric
L = Liquid Petroleum (L.P.) Gas
ST200L ST200N SU200L SU200N UA200L UA200N UT200L UT200N UU200L UU200N
CT200S CT200T CU200S CU200T DR200S2-BT200S DR200S2-BT200T DR200S2-BU200S DR200S2-BU200T HT200S HT200T HU200S
HU200T IT200S IT200T ST200S ST200T SU200S SU200T UT200S UT200T UU200S UU200T
Not Applicable
N = Natural Gas
Part No. 70458101ENR7
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 9
Introduction
S = Steam
T = Thermal Oil
Includes models with the following control suffixes
R3 – reversing DX4 OPL RE – reversing LED OPL RQ – reversing dual digital timer
RD – reversing DMP OPL RM – reversing OPL micro RU – reversing UniLinc OPL
Contact Information
If service is required, contact the nearest Factory Authorized Service Center.
If you are unable to locate an authorized service center or are unsatisfied with the service performed on your unit, contact:
Alliance Laundry Systems Shepard Street P.O. Box 990 Ripon, WI 54971-0990 U.S.A. www.alliancelaundry.com Phone: +1 (920) 748-3121 Ripon, Wisconsin +32 56 41 20 54 Wevelgem, Belgium
When calling or writing about your unit, PLEASE GIVE THE MODEL AND SERIAL NUMBERS. The model and serial numbers are located on the nameplate. The nameplate will be in the location shown in Figure 1 .
Date Purchased ______________________________
Model Number ______________________________ Serial Number _______________________________ Please include a copy of your bill of sale and any service
receipts you have.
WARNING
To reduce the risk of serious injury or death, DO NOT repair or replace any part of the unit or attempt any servicing unless specifically recommended in the user-maintenance instructions or in published user-repair instructions that you understand and have the skills to carry out.
W329
If replacement parts are required, contact the source from where you purchased your tumble dryer or call +1 (920) 748-3950 or +32 56 41 20 54 for the name and address of the nearest authorized parts distributor.
10
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458101ENR7
Serial Plate
1
Introduction
Figure 1
Part No. 70458101ENR7
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 11
Safety Information
Safety Information
Safety Information
Precautionary statements (“DANGER,” “WARNING,” and “CAUTION”), followed by specific instructions, are found in this manual and on machine decals. These precautions are intended for the personal safety of the operator, user, servicer, and those maintaining the machine.
DANGER
Indicates an imminently hazardous situation that, if not avoided, will cause severe personal injury or death.
WARNING
Indicates a hazardous situation that, if not avoided, could cause severe personal injury or death.
NOTE: The WARNING and IMPORTANT instructions appearing in this manual are not meant to cover all possible conditions and situations that may occur. It must be understood that common sense, caution and carefulness are factors which CANNOT be built into this tumble dryer. These factors MUST BE supplied by the person(s) installing, maintaining or operating the tumble dryer.
Always contact your dealer, distributor, service agent or the manufacturer on any problems or conditions you do not understand.
Important Safety Instructions
WARNING
To reduce the risk of fire, electric shock, serious injury or death to persons when using your tumbler, follow these basic precautions.
W776
CAUTION
Indicates a hazardous situation that, if not avoided, may cause minor or moderate personal injury or property damage.
Additional precautionary statements (“IMPORTANT” and “NOTE”) are followed by specific instructions.
IMPORTANT: The word “IMPORTANT” is used to inform the reader of specific procedures where minor machine damage will occur if the procedure is not followed.
NOTE: The word “NOTE” is used to communicate installation, operation, maintenance or servicing information that is important but not hazard related.
WARNING
Failure to install, maintain, and/or operate this machine according to manufacturer’s instructions may result in conditions which can produce serious injury, death and/or property damage.
W051R1
Save These Instructions
Read all instructions before using the tumble dryer.
Install the tumble dryer according to the INSTALLATION instructions. Refer to the EARTHING (grounding) instructions for the proper earthing (grounding) of the tumble dryer. All connections for electrical power, earthing (grounding) and gas supply must comply with local codes and be made by licensed personnel when required. It is recommended that the machine be installed by qualified technicians.
Do not install or store the tumble dryer where it will be exposed to water and/or weather. The tumble dryer cannot be used in a closed room where the air supply is insufficient. If necessary, ventilation grids must be installed in the doors or the windows.
This appliance must not be activated without lint/foam filter.
When you perceive a gas odor, immediately switch off the gas supply and ventilate the room. Do not switch on electrical appliances and do not pull electrical switches. Do not use matches or lighters. Do not use a phone in the building. Warn the fitter, and if so desired, the gas company, as soon as possible.
To avoid fire and explosion, keep surrounding areas free of flammable and combustible products. Regularly clean the dryer drum and exhaust tube should be cleaned periodically by competent maintenance personnel. Daily remove piled up dust from filter and inside of filter compartment.
Do not use or store flammable materials near this appliance.
Part No. 70458101ENR7
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 12
Safety Information
Do not dry articles that have been previously cleaned in, washed in, soaked in or spotted with gasoline or machine oils, vegetable or cooking oils, cleaning waxes or chemicals, dry-cleaning solvents, thinner or other flammable or explosive substances as they give off vapors that could ignite, explode or cause fabric to catch on fire by itself.
Do not spray aerosols in the vicinity of this appliance while it is in operation.
Items such as foam rubber (latex foam), shower caps, waterproof textiles, rubber backed articles and clothes or pillows filled with foam rubber pads should not be dried in the tumble dryer. Do not use the appliance to dry materials with a low melting temperature (PVC, rubber, etc.).
Do not tumble fiberglass curtains and draperies unless the label says it can be done. If they are dried, wipe out the cylinder with a damp cloth to remove particles of fiberglass.
Do not allow children on or in the tumble dryer. This appliance is not intended for use by young children or infirm persons without supervision. Young children should be supervised to ensure that they do not play with the appliance.
Do not reach into the tumble dryer if the cylinder is revolving.
Use tumble dryer only for its intended purpose, drying fabrics. Always follow the fabric care instructions supplied by the textile manufacturer and only use the dryer drum to dry textiles that have been washed in water. Only insert spin­dried linen in the dryer.
Always read and follow manufacturer’s instructions on packages of laundry and cleaning aids. Heed all warnings or precautions. To reduce the risk of poisoning or chemical burns, keep them out of the reach of children at all times (preferably in a locked cabinet).
Do not use fabric softeners or products to eliminate static unless recommended by the manufacturer of the fabric softener or product.
Remove laundry immediately after tumble dryer stops.
DO NOT operate the tumble dryer if it is smoking, grinding or has missing or broken parts or removed guards or panels. DO NOT tamper with the controls or bypass any safety devices.
Tumble dryer will not operate with the loading door open. DO NOT bypass the door safety switch to permit the tumble dryer to operate with the door open. The tumble dryer will stop tumbling when the door is opened. Do not use the tumble dryer if it does not stop tumbling when the door is opened or starts tumbling without pressing or turning the START mechanism. Remove the tumble dryer from use and call for service.
Tumble dryer(s) will not operate with lint panel open. DO NOT bypass lint panel safety switch to permit the tumble dryer to operate with the lint panel open.
Do not modify this appliance.
Always clean the lint filter daily. Keep area around the exhaust opening and adjacent surrounding area free from the accumulation of lint, dust and dirt. The interior of the tumble
dryer and the exhaust duct should be cleaned periodically by qualified service personnel.
Solvent vapors from dry-cleaning machines create acids when drawn through the heater of the drying unit. These acids are corrosive to the tumble dryer as well as the laundry load being dried. Be sure make-up air is free of solvent vapors.
At the end of each working day, close off all main supplies of gas, steam and current.
Do not repair or replace any part of the tumble dryer, or attempt any servicing unless specifically recommended in the user-maintenance instructions or in published user-repair instructions that the user understands and has the skills to carry out. ALWAYS disconnect and lockout the electrical power to the tumble dryer before servicing. Disconnect power by shutting off appropriate breaker or fuse.
Before the tumble dryer is removed from service or discarded, remove the door to the drying compartment and the door to the lint compartment.
Failure to install, maintain, and/or operate this tumble dryer according to the manufacturer’s instructions may result in conditions which can produce bodily injury and/or property damage.
NOTE: The WARNINGS and IMPORTANT SAFETY INSTRUCTIONS appearing in this manual are not meant to cover all possible conditions and situations that may occur. Common sense, caution and care must be exercised when installing, maintaining, or operating the tumble dryer.
Always contact your dealer, distributor, service agent or the manufacturer on any problems or conditions you do not understand.
Part No. 70458101ENR7
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 13
Specifications and Dimensions
Specifications and Dimensions
Specifications 120 Series 170 Series 200 Series
Specifications and Dimensions
Noise level measured during operation at operator position of 3.3 feet (1 meter) in front of machine and 5.2 feet (1.6 meters) from floor.
Cylinder Size: Inches (mm) 44 x 41 (1,118 x 1,041) 50.75 x 42.5
Cylinder Capacity dry weight: Pounds (kg)
Gas and Electric 1,338 (607) 1,667 (756) 1,718 (779)Standard Packaging Weight: Pounds (kg)
Standard Packaging Shipping Dimensions: Inch (mm)
Packaging Weight: Pounds (kg)
Steam 1,446 (656) 1,776 (806) 1,818 (825)
Gas and Electric 1,447 (656) 1,791 (812) 1,868 (848)Slat Crate
Steam 1,547 (702) 1,891 (858) 1,968 (893)
66 dBA 66 dBA 66 dBA
(1,289 x 1,080)
120 (54.4) 170 (77.1) 200 (90.7)
48.5 x 72 x 90 (1,232 x 1,829 x 2,286)
58 x 74.5 x 99 (1,473 x 1,892 x 2,515)
50.75 x 50 (1,289 x 1,270)
56 x 80 x 99 (1,422 x 2,032 x 2,515)
Slat Crate Shipping Dimensions: Inch (mm)
Cylinder Motor: HP (kW) 0.75 (0.560) 0.75 (0.560) 0.75 (0.560)
Fan Motor: HP (kW) 1 (0.746) 3 (2.238) 3 (2.238)
Air Outlet Diameter: Inches (mm) 10 (254) 12 (300) 12 (300)
Maximum Static Back Pressure: W.C.I. (mbar, kPa)
Maximum Airflow: C.F.M. (L/sec.) 1,600 (755) 2,450 (1,156) 2,450 (1,156)
Part No. 70458101ENR7
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 14
51.5 x 74 x 90.75 (1,308 x 1,880 x 2,305)
0.8 (2.0, 0.2) 0.8 (2.0, 0.2) 0.8 (2.0, 0.2)
Gas Models
61 x 76.5 x 99.75 (1,549 x 1,943 x 2,534)
61 x 83 x 101 (1,549 x 2,108 x 2,565)
Specifications and Dimensions
Specifications 120 Series 170 Series 200 Series
Net Weight (approximate): Pounds (kg) 1,275 (578) 1,575 (716) 1,707 (774)
Gas Connection Models through 3/10/13:
1 in. NPT 1 in. NPT 3/4 in. NPT Models Starting 3/11/13:
1 in. NPT
Gas Burner Rating:
270,000 (285, 79.13) 395,000 (417, 115.77) 425,000 (448, 124.56)
Btu/hr. (Mj/hr., kW)
Steam Models
Net Weight (approximate): Pounds (kg) 1,375 (624) 1,675 (761) 1,807 (820)
Steam Connection 3/4 in. NPT inlet
3/4 in. NPT outlet
Steam Coil Rating at 100 psig:
405,000 (183.1) 648,000 (294.2) 648,000 (294.2)
3/4 in. NPT inlet
1 in. NPT outlet
3/4 in. NPT inlet 1 in. NPT outlet
Btu/hr. (kg/hr.) (recommended operating pressure 80-100 psig)
Electric Models
Heating Element Rating: Kilowatts
60 kW Not Applicable Not Applicable
(kW)
NOTE: All machines are shipped with extra nipple to convert to metric thread (from Standard).
Part No. 70458101ENR7
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 15
Specifications and Dimensions
120 Series Tumble Dryer Dimensions and Exhaust Outlet Locations
TMB2396N
Top View of Exhaust Duct
1
Cabinet Dimensions
Models A B C D E F
120L/N/E 31.38 in.
(797 mm)
120S 31.38 in.
(797 mm)
32.5 in. (826 mm)
32.5 in. (826 mm)
48.91 in. (1,242 mm)
48.91 in. (1,242 mm)
49.91 in. (1,268 mm)
49.91 in. (1,268 mm)
67.92 in. (1,725 mm)
67.92 in. (1,725 mm)
45.38 in. (1,153 mm)
45.38 in. (1,153 mm)
Models G H I J* K* L*
120L/N/E 46.38 in.
(1,178 mm)
85.7 in. (2,177 mm)
70 in. (1,778 mm)
41.6 in. (1,057 mm)
43.2 in. (1,097 mm)
61.5 in. (1,562 mm)
16
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458101ENR7
Cabinet Dimensions
Specifications and Dimensions
120S 46.38 in.
(1,178 mm)
83.5 in. (2,121 mm)
70 in. (1,778 mm)
41.6 in. (1,057 mm)
43.2 in. (1,097 mm)
* Fire suppression system optional - may not be on machine. Refer to Position and Level the Tumble Dryer to temporarily
reduce the heights of these models.
Exhaust Outlet Dimensions and Locations
Models U V W X Y Z
120L/N/E 63.45 in.
(1,612 mm)
120S 60.7 in.
(1,542 mm)
8.44 in. (214 mm)
8.44 in. (214 mm)
5 in. (127 mm) 8.18 in.
(208 mm)
5 in. (127 mm) 8.18 in.
(208 mm)
6.82 in. (173 mm)
6.82 in. (173 mm)
61.5 in. (1,562 mm)
8.18 in. (208 mm)
8.18 in. (208 mm)
Part No. 70458101ENR7
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 17
Specifications and Dimensions
170 and 200 Series Tumble Dryer Dimensions and Exhaust Outlet Locations
TMB2397N
Top View of Exhaust Duct
1
Cabinet Dimensions
Models A B C D E F
170L/N/S 33.86 in.
(860 mm)
200L/N/S 32.1 in.
(815 mm)
32.5 in. ( 826 mm)
35.6 in. ( 904 mm)
50.75 in. (1,289 mm)
58 in. (1,473 mm)
51.75 in. (1,314 mm)
59.25 in. (1,505 mm)
68.85 in. (1,749 mm)
76.35 in. (1,939 mm)
52.12 in. (1,324 mm)
52.12 in. (1,324 mm)
Models G H I J* K* L*
170L/N/S 53.12 in.
(1,349 mm)
94 in. (2,388 mm)
75.12 in. (1,908 mm)
48.86 in. (1,241 mm)
50.45 in. (1,281 mm)
62.5 in. (1,588 mm)
18
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458101ENR7
Cabinet Dimensions
Specifications and Dimensions
200L/N/S 53.12 in.
(1,349 mm)
94 in. (2,388 mm)
75.12 in. (1,908 mm)
48.86 in. (1,241 mm)
50.45 in. (1,281 mm)
62.5 in. (1,588 mm)
* Fire suppression system optional - may not be on machine. Refer to Position and Level the Tumble Dryer to temporarily
reduce the heights of these models.
Exhaust Outlet Dimensions and Locations
Models V W X Y
170L/N/S 42.38 in. (1,076 mm) 6.75 in. (171 mm) 6 in. (152 mm) 7 in. (178 mm)
200L/N/S 42.38 in. (1076 mm) 6.75 in. (171 mm) 6 in. (152 mm) 7 in. (178 mm)
Part No. 70458101ENR7
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 19
Specifications and Dimensions
Electric and Gas Connection Locations for Gas Models Through 3/10/13
TMB2255NTMB2382N
120L/N
1
170L/N
2
200L/N
3
Electrical Connection Gas Connection
Models A B C D Diameter
120L/N 18.34 in.
(466 mm)
170L/N 21 in. (533 mm) 81 in. (2,057 mm) 14.85 in.
200L/N 21 in. (533 mm) 81 in. (2,057 mm) 13.7 in. (348 mm) 77.4 in.
77.84 in. (1,977 mm)
12.5 in. (318 mm) 70.5 in. (1,791 mm)
77.4 in.
(377 mm)
(1,966 mm)
3/4 in. NPT
1 in. NPT
1 in. NPT
(1,966 mm)
20
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458101ENR7
Specifications and Dimensions
Electric and Gas Connection Locations for Gas Models Starting 3/11/13
TMB2400N
120L/N
1
170L/N and 200L/N
2
Electrical Connection Gas Connection
Models A B C D Diameter
120L/N 18.34 in.
(466 mm)
170L/N 21 in. (533 mm) 81 in. (2,057 mm) 14.85 in.
200L/N 21 in. (533 mm) 81 in. (2,057 mm) 14.85 in.
77.84 in. (1,977 mm)
12.5 in. (318 mm) 70.5 in. (1,791 mm)
77.4 in.
(377 mm)
(1,966 mm)
77.4 in.
(377 mm)
(1,966 mm)
1 in. NPT
1 in. NPT
1 in. NPT
Part No. 70458101ENR7
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 21
Specifications and Dimensions
Electric and Steam Connection Locations for Steam Models Through 3/10/13
TMB2401NTMB2383N
120S
1
170S
2
200S
3
Steam Inlet
Models Diameter A1 A2 F
120S 3/4 in. NPT 35.875 in. (911 mm) 13.375 in. (340 mm) 82.75 in. (2,102 mm)
170S 3/4 in. NPT 37.625 in. (956 mm) 15.25 in. (387 mm) 88 in. (2,235 mm)
200S 3/4 in. NPT 37.625 in. (956 mm) 15.25 in. (387 mm) 88 in. (2,235 mm)
Steam Outlet
Models Diameter B1 B2 D
120S 3/4 in. NPT 34.625 in. (879 mm) 13.125 in. (333 mm) 68.5 in. (1,740 mm)
170S 1 in. NPT 44.625 in. (1,133 mm) 8.75 in. (222 mm) 71.75 in. (1,822 mm)
22
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458101ENR7
Specifications and Dimensions
Steam Outlet
Models Diameter B1 B2 D
200S 1 in. NPT 44.625 in. (1,133 mm) 8.75 in. (222 mm) 71.75 in. (1,822 mm)
Electrical Connection
Models C E
120S 18.34 in. (466 mm) 77.84 in. (1,977 mm)
170S 21 in. (533 mm) 81 in. (2,057 mm)
200S 21 in. (533 mm) 81 in. (2,057 mm)
Part No. 70458101ENR7
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 23
Specifications and Dimensions
Electric and Steam Connection Locations for Steam Models Starting 3/11/13
TMB2401N
120S
1
170S and 200S
2
Steam Inlet
Models Diameter A1 A2 F
120S 3/4 in. NPT 35.875 in. (911 mm) 13.375 in. (340 mm) 82.75 in. (2,102 mm)
170S 3/4 in. NPT 37.625 in. (956 mm) 15.5 in. (394 mm) 87.625 in. (2,226 mm)
200S 3/4 in. NPT 37.625 in. (956 mm) 15.5 in. (394 mm) 87.625 in. (2,226 mm)
Steam Outlet
Models Diameter B1 B2 D
120S 3/4 in. NPT 34.625 in. (879 mm) 13.125 in. (333 mm) 68.5 in. (1,740 mm)
170S 1 in. NPT 44.125 in. (1,133 mm) 9 in. (229 mm) 72.125 in. (1,832 mm)
24
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458101ENR7
Specifications and Dimensions
Steam Outlet
Models Diameter B1 B2 D
200S 1 in. NPT 44.125 in. (1,133 mm) 9 in. (229 mm) 72.125 in. (1,832 mm)
Electrical Connection
Models C E
120S 18.34 in. (466 mm) 77.84 in. (1,977 mm)
170S 21 in. (533 mm) 81 in. (2,057 mm)
200S 21 in. (533 mm) 81 in. (2,057 mm)
Part No. 70458101ENR7
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 25
Specifications and Dimensions
Electric Connection Location for Electric Models
TMB2336N
Models A B
120E 35.81 in. (910 mm) 85.64 in. (2,175 mm)
26
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458101ENR7
Installation
Installation
Pre-Installation Inspection
Upon delivery, visually inspect the crate, carton and parts for any visible shipping damage. If the crate, carton, or cover is damaged or signs of possible damage are evident, have the carrier note the condition on the shipping papers before the shipping receipt is signed, or advise the carrier of the condition as soon as it is discovered.
Remove the crate and protective cover as soon as possible and check the items listed on the packing list. Advise the carrier of any damaged or missing articles as soon as possible. A written claim should be filed with the carrier immediately if articles are damaged or missing.
IMPORTANT: Remove the shipping tape from the two back draft dampers located in the exhaust outlet.
IMPORTANT: Warranty is void unless tumble dryer is installed according to instructions in this manual. Installation should comply with minimum specifications and requirements detailed in this manual and applicable local gas fitting regulations, municipal building codes, water supply regulations, electrical wiring regulations, and any other relevant statutory regulations. Due to varied requirements, applicable local codes should be thoroughly understood and all pre-installation work arranged for accordingly.
Materials Required (Obtain Locally)
Steam Models One steam shut-off valve for steam service
line to be connected upstream of solenoid steam valve.
Two steam shut-off valves for each condensate return line.
Flexible steam hoses with a 125 psig (pounds per square inch gauge) (8.79 kg/sq. cm) working pressure for connecting steam coils. Refer to Figure
21 120 Series Tumble Dryers and Figure 22 170 and 200 Series Tumble Dryers for
sizing and connection configurations. Two steam traps for steam coil outlets to
condensate return line. Optional – Two vacuum breakers for
condensate return lines.
IMPORTANT: 3 Phase Only – Each tumble dryer must be connected to its own individual branch circuit breaker, not fuses, to avoid the possibility of “single phasing” and causing premature failure of the motor(s).
Materials Required (Obtain Locally)
All Models One Single Pole fused disconnect switch
or circuit breaker on 1 Phase models. Circuit breaker on 3 Phase models.
Gas Models One gas shut-off valve for gas service line
to each tumble dryer.
Location Requirements
The tumble dryer must be installed on a level floor. Floor covering materials such as carpeting or tile should be removed.
To assure compliance, consult local building code requirements. The tumble dryer must not be installed or stored in area where it will be exposed to water and/or weather.
IMPORTANT: DO NOT block the airflow at the rear of the tumble dryer with laundry or other articles. Doing so would prevent adequate air supply to the combustion chamber of the tumble dryer.
A typical tumble dryer enclosure is shown in Figure 2 .
IMPORTANT: Install tumble dryers with sufficient clearance for servicing and operation, refer to Figure 2 .
Part No. 70458101ENR7
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 27
Installation
WARNING
To reduce the risk of severe injury, clearance of tumbler cabinet from combustible construction must conform to the minimum clearances, and/or local codes and ordinances.
W770
28
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458101ENR7
Loading...
+ 63 hidden pages