Alliance Laundry Systems DRY710C User Manual

Page 1
Clothes Dryer
DRY710C
Electric and Gas Models
Installation/Operation
Keep These Instructions for Future Reference.
(If this machine changes ownership, this manual must accompany machine.)
www.comlaundry.com
Part No. 513005R5
Page 2
Page 3
IMPORTANT: Purchaser must consult the local gas supplier for suggested instructions to be followed if the
• Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
• WHAT TO DO IF YOU SMELL GAS: – Do not try to light any appliance. – Do not touch any electrical switch; do not use any phone in your building. – Clear the room, building or area of all occupants. – Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s
instructions.
– If you cannot reach your gas supplier, call the fire department.
• Installation and service must be performed by a qualified installer, service agency or the gas supplier.
W052
FOR YOUR SAFETY, the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury or death. Keep this manual for future reference. If this machine changes ownership, this manual must accompany machine.
W755
WARNING
• Installation of unit must be performed by a qualified installer.
• Install clothes dryer according to manufacturer’s instructions and local codes.
• DO NOT install a clothes dryer with flexible plastic venting materials. If flexible metal (foil type) duct is installed, it must be of a specific type identified by the appliance manufacturer as suitable for use with clothes dryers. Refer to section on connecting exhaust system. Flexible venting materials are known to collapse, be easily crushed, and trap lint. These conditions will obstruct clothes dryer airflow and increase the risk of fire.
W729R1
WARNING
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
W053
dryer user smells gas. The gas utility instructions plus the SAFETY and WARNING note directly above must be posted in a prominent location near the dryer for customer use.
The following information applies to the state of Massachusetts, USA.
This appliance can only be installed by a Massachusetts licensed plumber or gas fitter.
This appliance must be installed with a 36 inch (91 cm) long flexible gas connector.
A “T-Handle” type gas shut-off valve must be installed in the gas supply line to this appliance.
This appliance must not be installed in a bedroom or bathroom.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT513005
1
Page 4
Table of
Contents
Safety Information .............................................................................. 3
Explanation of Safety Messages........................................................... 3
Important Safety Instructions ............................................................... 3
Installation........................................................................................... 5
Dimensions ........................................................................................... 5
Metered Models ............................................................................... 5
Before You Start................................................................................... 6
Tools ................................................................................................ 6
Card Reader Models ........................................................................ 6
Installing the Dryer............................................................................... 7
Step 1: Position and Level the Dryer ............................................... 7
Step 2: Connect Dryer Exhaust System ........................................... 9
Exhaust Direction............................................................................. 10
Exhaust System................................................................................ 11
Multi-Dryer Installation Exhaust Requirements.............................. 12
Step 3: (Gas Dryer Only) Connect Gas Supply Pipe ....................... 14
Step 4: (Electric Dryer Only) Connect Electrical Plug.................... 15
Step 5: Reverse Door, if Desired ..................................................... 21
Step 6: Wipe Out Inside of Dryer .................................................... 22
Step 7: Plug In the Dryer ................................................................. 22
Step 8: Recheck Steps 1-7................................................................ 24
Step 9: Check Heat Source .............................................................. 24
Vending................................................................................................ 25
Meter Case............................................................................................ 25
Additional Dryer Security..................................................................... 25
Operation............................................................................................. 26
Operation Instructions .......................................................................... 26
Step 1: Clean Lint Filter................................................................... 26
Step 2: Load Laundry....................................................................... 26
Step 3: Close Loading Door............................................................. 26
Step 4: Set Fabric Selector............................................................... 27
Step 5: Insert Coin(s) or Card.......................................................... 27
Step 6: Start Dryer ........................................................................... 28
Indicator Lights................................................................................ 28
Maintenance ........................................................................................ 29
Lubrication............................................................................................ 29
Care of Your Dryer............................................................................... 29
Dryer Interior ................................................................................... 29
Cabinet ............................................................................................. 29
Control Panel ................................................................................... 29
Exhaust System................................................................................ 29
Lint Filter.............................................................................................. 30
Motor Overload Protector..................................................................... 30
For Energy Conservation...................................................................... 30
Troubleshooting.................................................................................. 31
Contact Information........................................................................... 32
Installer Checklist ............................................................... Back Cover
© Copyright 2011, Alliance Laundry Systems LLC All rights reserved. No part of the contents of this book may be reproduced or transmitted in any form or by any
means without the expressed written consent of the publisher.
2
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
513005
Page 5
Safety Information
Indicates an imminently hazardous situation that, if not avoided, will cause severe personal injury or death.
DANGER
Indicates a hazardous situation that, if not avoided, could cause severe personal injury or death.
WARNING
Indicates a hazardous situation that, if not avoided, may cause minor or moderate personal injury or property damage.
CAUTION
To reduce the risk of fire, electric shock, or injury to persons when using your dryer, follow these basic precautions:
W034
WARNING
Explanation of Safety Messages
Throughout this manual and on machine decals, you will find precautionary statements (“DANGER,” “WARNING,” and “CAUTION”) followed by specific instructions. These precautions are intended for the personal safety of the operator, user, servicer, and those maintaining the machine.
Important Safety Instructions
Save These Instructions
1. Read all instructions before using the dryer.
2. Refer to the GROUNDING INSTRUCTIONS in the INSTALLATION manual for the proper grounding of the dryer.
3. Do not dry articles that have been previously cleaned in, washed in, soaked in, or spotted with gasoline, dry-cleaning solvents, other flammable or explosive substances as they give off vapors that could ignite or explode.
4. Do not allow children to play on or in the dryer. Close supervision of children is necessary when the dryer is used near children. This is a safety rule for all appliances.
Additional precautionary statements (“IMPORTANT” and “NOTE”) are followed by specific instructions.
IMPORTANT: The word “IMPORTANT” is used to inform the reader of specific procedures where minor machine damage will occur if the procedure is not followed.
NOTE: The word “NOTE” is used to communicate installation, operation, maintenance or servicing information that is important but not hazard related.
5. Before the dryer is removed from service or discarded, remove the door to the drying compartment.
6. Do not reach into the dryer if the cylinder is revolving.
7. Do not install or store the dryer where it will be exposed to water and/or weather.
8. Do not tamper with the controls.
9. Do not repair or replace any part of the dryer, or attempt any servicing unless specifically recommended in the user-maintenance instructions or in published user-repair instructions that you understand and have the skills to carry out.
10. Do not use fabric softeners or products to eliminate static unless recommended by the manufacturer of the fabric softener or product.
11. To reduce the risk of fire, DO NOT DRY plastics or articles containing foam rubber or similarly textured rubberlike materials.
12. ALWAYS clean the lint filter after every load. A layer of lint in the filter reduces drying efficiency and prolongs drying time.
513005
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
3
Page 6
Safety Information
13. Keep area around the exhaust opening and adjacent surrounding area free from the accumulation of lint, dust and dirt.
14. The interior of the dryer and the exhaust duct should be cleaned periodically by qualified service personnel.
15. If not installed, operated and maintained in accordance with the manufacturer’s instructions or if there is damage to or mishandling of this product’s components, use of this product could expose you to substances in the fuel or from fuel combustion which can cause death or serious illness and which are known to the State of California to cause cancer, birth defects or other reproductive harm.
16. Dryer will not operate with the loading door open. DO NOT bypass the door safety switch by permitting the dryer to operate with the door open. The dryer will stop tumbling when the door is opened. Do not use the dryer if it does not stop tumbling when the door is opened or starts tumbling without pressing the START mechanism. Remove the dryer from use and call the service person.
17. Do not put articles soiled with vegetable or cooking oil in the dryer, as these oils may not be removed during washing. Due to the remaining oil, the fabric may catch on fire by itself.
18. To reduce the risk of fire, DO NOT put clothes which have traces of any flammable substances such as machine oil, flammable chemicals, thinner, etc., or anything containing wax or chemicals such as in mops and cleaning cloths, or anything dry-cleaned at home with a dry­cleaning solvent in the dryer.
19. Use the dryer only for its intended purpose, drying clothes.
20. Always disconnect the electrical power to the dryer before attempting service. Disconnect the power cord by grasping the plug, not the cord.
21. If supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or its service agent.
22. Install this dryer according to the INSTALLATION INSTRUCTIONS. All connections for electrical power, grounding and gas supply must comply with local codes and be made by licensed personnel when required. Do not do it yourself unless you know how!
23. Remove laundry immediately after the dryer stops.
24. Always read and follow manufacturer’s instructions on packages of laundry and cleaning aids. Heed all warnings or precautions. To reduce the risk of poisoning or chemical burns, keep them out of reach of children at all times (preferably in a locked cabinet).
25. Do not tumble fiberglass curtains and draperies unless the label says it can be done. If they are dried, wipe out the cylinder with a damp cloth to remove particles of fiberglass.
26. ALWAYS follow the fabric care instructions supplied by the garment manufacturer.
27. Never operate the dryer with any guards and/or panels removed.
28. DO NOT operate the dryer with missing or broken parts.
29. DO NOT bypass any safety devices.
30. Failure to install, maintain, and/or operate this machine according to the manufacturer’s instructions may result in conditions which can produce bodily injury and/or property damage.
IMPORTANT: Solvent vapors from dry-cleaning machines create acids when drawn through the heater of the drying unit. These acids are corrosive to the dryer as well as to the laundry load being dried. Be sure make-up air is free of solvent vapors.
IMPORTANT: Have your dryer installed properly. Don’t do it yourself unless you know how!
NOTE: The WARNING and IMPORTANT SAFETY INSTRUCTIONS appearing in this manual are not meant to cover all possible conditions and situations that may occur. Common sense, caution and care must be exercised when installing, maintaining, or operating the dryer.
Always contact your dealer, distributor, service agent or the manufacturer about any problems or conditions you do not understand.
4
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
513005
Page 7
Dimensions
23.5 in.
(59.7 cm)
8.0 in.
(20.3 cm)
0.4 in.
(1.02 cm)
28 in.
(71.1 cm)
*36 in. (91.4 cm)
15.4 in.
(39.1 cm)
ELECTRIC MODELS
4.0 in.
(10.2 cm)
26.9 in.
(68.3 cm)
22.06 in. (56 cm)
*4.5 in. (11.4 cm)
*15.44 in.
(39.2 cm)
*38.19 in. (97 cm)
*43 in. (109.2 cm)
Standard Capacity Meter Case
*43.875 in. (111.44 cm)
High Capacity Meter Case
GAS MODELS
23.5 in.
(59.7 cm)
8.0 in.
(20.3 cm)
28 in.
(71.1 cm)
*38.19 in. (97 cm)
15.4 in.
(39.1 cm)
2.3 in. (6 cm)
26.9 in.
(68.3 cm)
0.4 in.
(1.02 cm)
2.8 in. (7 cm)
1
22.06 in. (56 cm)
*4.5 in. (11.4 cm)
4.0 in. (10.2 cm)
*15.44 in.
(39.2 cm)
*36 in. (91.4 cm)
*43 in. (109.2 cm)
Standard Capacity Meter Case
*43.875 (111.44 cm)
High Capacity Meter Case
Metered Models
*With leveling legs turned into base.
Installation
DRY2353N
*With leveling legs turned into base.
1 3/8 in. N.P.T. Gas Connection
NOTE: Side, rear and bottom exhaust openings are 4 inch (10.2 cm) ducting. Gas models cannot be vented out left side of cabinet because of burner housing.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
513005
IMPORTANT: The dryer should have sufficient clearance around it for needed ventilation and for the ease of installation and servicing. For maximum drying performance, we recommend that more clearance be allowed around the dryer than the clearances that are listed throughout this manual.
DRY2354N
5
Page 8
Installation
1
2
3
4
5
1
Any disassembly requiring the use of tools must be performed by a suitably qualified service person.
W299
WARNING
Before You Start
Tool s
For most installations, the basic tools you will need are:
D818I
1 Wrench 2 Screwdrivers 3 Level 4 Teflon Tape 5 Duct Tape
Card Reader Models
The machine is shipped from the factory with the Electronic Control Diagnostic Harness Assembly unplugged. To avoid unauthorized manual programming or vending perform the following steps.
1. Open service door. Refer to Figure 1.
2. Locate diagnostic harness on electronic control.
3. Plug connectors for “white/black” wire and “red/ blue” wire together.
.
FLW6R
1 Service Door
Figure 2
Figure 1
NOTE: An 8 in. (20.32 cm) coin drawer is required for coin operated models with standard capacity meter case and high capacity meter case models starting with Serial Nos. beginning 1010. High capacity meter case models with Serial Nos. beginning 0910 through 1010 require a 7.21 in. (18.31 cm) coin drawer.
6
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
513005
Page 9
Installation
D
1
2
3
4
Installing the Dryer
Step 1: Position and Level the Dryer
Install dryer before washer. This allows room for attaching exhaust duct.
Install the four rubber feet (in accessories bag).
Select a location with a solid floor. Dryers installed in residential garages must be elevated 18 inches (46 cm) above the floor.
No other fuel burning appliance should be installed in the same closet with the dryer.
The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.
The dryer needs sufficient clearance and an adequate air supply for proper operation and ventilation, and for easier installation and servicing. (Minimum clearances are shown in Figure 4).
Place the dryer in position, and adjust the legs until the dryer is level from side to side and front to back. Leveling legs can be adjusted from inside the dryer with a 1/4 in. driver. All four legs must rest firmly on the floor so the weight of the dryer is evenly distributed. The dryer must not rock.
IMPORTANT: In mobile home installations, gas dryers MUST be permanently attached to the floor at the time of installation. Order No. 526P3 Hold Down Kit (available at extra cost) for a manufactured (mobile) home installation. Follow the instructions supplied with the kit.
Installation of unit must conform to the Manufactured Home Construction and Safety Standards, Title 24 CF4, Part 32-80 or Standard CAN/CSA-Z240 MH.
DRY2355N
1 Dryer Base 2 Level 3 Leveling Leg 4 Rubber Foot
513005
Figure 3
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
7
Page 10
Installation
D337I
1
2 (G)
3
A
E
**42 in.
(106.7 cm)
F
F
B
AA
C
FRONT VIEW
(W/O CLOSET DOOR)
SIDE VIEW
(CLOSET DOOR)
FRONT VIEW
(CLOSET DOOR)
D
Area Description
Free Standing/Alcove
Installation
Closet Installation
A
Dryer sides and rear clearance 0 in. (0 cm) 0 in. (0 cm)
B
Dryer top clearance 12 in. (30.5 cm) 12 in. (30.5 cm)
C
Dryer front clearance Not Applicable 2 in. (5.1 cm)
D
Exhaust duct clearance to combustible material
2 in. (5.1 cm) 2 in. (5.1 cm)
E
Weather hood to ground clearance 12 in. (30.5 cm) 12 in. (30.5 cm)
F
Distance from floor or ceiling to hole edge
Not Applicable 3 in. (7.6 cm)
G*
Area of centered air openings in closet door
Not Applicable 40 sq. in./open (260 sq. cm)
*Louvered door with equivalent air openings is acceptable. (Minimum clearances are shown.)
D337I
1 Closet Door 2 Centered Air Openings (G) (2 Openings
minimum)
3 Outer Wall of Enclosure
**NOTE: For new installations, locate top of wall vent 42 inches (106.7 cm) above floor to make venting easier to connect.
8
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Figure 4
513005
Page 11
Installation
To reduce the risk of fire and combustion gas accumulation the dryer MUST be exhausted to the outdoors.
W604
To reduce the risk of fire and the accumulation of combustion gases, DO NOT exhaust dryer air into a window well, gas vent, chimney or enclosed, unventilated area, such as an attic, wall, ceiling, crawl space under a building or concealed space of a building.
W045
WARNING
This gas appliance contains or produces a chemical or chemicals which can cause death or serious illness and which are known to the State of California to cause cancer, birth defects, or other reproductive harm. To reduce the risk from substances in the fuel or from fuel combustion, make sure this appliance is installed, operated, and maintained according to the instructions in this manual.
W115
To reduce the risk of fire, DO NOT use plastic or thin foil ducting to exhaust the dryer.
W354
To reduce the risk of fire, the exhaust duct and weather hood MUST be fabricated of a material that will not support combustion. Rigid or flexible metal pipe is recommended for a clothes dryer.
W048
To reduce the risk of fire due to increased static pressure, we do not recommend installation of in-line secondary lint filters or lint collectors. If secondary systems are mandated, frequently clean the system to assure safe operation.
W749
WARNING
DRY2356N
DRY2357N
DON’T
DO
Step 2: Connect Dryer Exhaust System
DO NOT use plastic or thin foil ducting. Rigid
metal duct is recommended.
DRY2356N DRY2357N
Figure 5
Locate dryer so exhaust duct is as short as
possible.
Be certain old ducts are cleaned before installing
your new dryer.
Use 4 inch (102 mm) diameter rigid or flexible
metal duct.
IMPORTANT: Installing in-line filters or lint collectors will cause increased static pressure. Failure to maintain the secondary lint system will decrease dryer efficiency and may void machine warranty
513005
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
The male end of each section of duct must point
away from the dryer.
Use as few elbows as possible.
Use duct tape or pop-rivets on all duct joints. DO
NOT use sheet metal screws or fasteners on exhaust pipe joints which extend into the duct and catch lint.
Ductwork that runs through unheated areas must
be insulated to help reduce condensation and lint build-up on pipe walls.
Install backdraft dampers in multi-dryer
installations.
In mobile home installations, dryer exhaust duct
must be secured to mobile home structure.
Dryer exhaust duct MUST NOT terminate under
mobile home.
Dryer exhausts 220 cfm (measured at back of
dryer).
DO NOT install flexible duct in concealed
spaces, such as a wall or ceiling.
9
Page 12
Installation
Static pressure in exhaust duct should not be
greater than .6 inches water column (1.5 cm), measured with manometer placed on exhaust duct two feet (61 cm) from dryer (check with dryer running and no load). In multi-dryer installations, all dryers connected to the main collector duct should be operating when pressure is checked.
Exhausting dryer in hard-to-reach locations can
be done by installing 521P3 Flexible Metal Vent Kit (available as optional equipment at extra cost).
Sufficient make-up air must be supplied to
replace the air exhausted by the dryer. The free area of any opening for outside air must be at least 40 in
2
(260 cm2).
Energy efficient buildings with low air
infiltration rates should be equipped with an air exchanger that can accommodate on demand make-up air needs in the laundry room. These devices can be obtained through your building contractor or building material suppliers.
Do not draw make-up air from a room containing
a gas fired water heater, a dry cleaner or a hair salon.
Exhaust Direction
The dryer can be exhausted to the outdoors through the back, left, right or bottom of the dryer. EXCEPTION:
Gas dryers cannot be vented out the left side because of the burner housing.
Dryer is shipped from factory ready for rear exhaust.
Exhausting the dryer through sides or bottom can be accomplished by installing a Directional Exhaust Kit, 528P3, available as optional equipment at extra cost.
Failure to exhaust dryer properly will void
warranty.
NOTE: Venting materials are not supplied with the dryer (obtain locally).
IMPORTANT: DO NOT block the airflow at the bottom of the dryer’s front panel with laundry, rugs, etc. Blockage will decrease airflow through the dryer, thus reducing the efficiency of the dryer.
10
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
513005
Page 13
Installation
4 in.
(10.2 cm)
4 in.
(10.2 cm)
2-1/2 in.
(6.35 cm)
Exhaust System
For best drying results, recommended maximum length of exhaust system is shown in Tab le 1 .
To prevent backdraft when dryer is not in operation, outer end of exhaust pipe must have a weather hood with hinged dampers (obtain locally).
Number of
90° Elbows
Maximum length of 4 in. (10.2 cm) diameter rigid metal duct.
0 65 feet (19.8 m) 55 feet (16.8 m)
1 55 feet (16.8 m) 47 feet (14.3 m)
2 47 feet (14.3 m) 41 feet (12.5 m)
3 36 feet (11.0 m) 30 feet (9.1 m)
4 28 feet (8.5 m) 22 feet (6.7 m)
Recommended Use Only for Short Run installations
NOTE: Weather hood should be installed at least 12 inches (30.5 cm) above the ground. Larger clearances may be necessary for installations where heavy snowfall can occur.
Weather Hood Type
D673I D802I
NOTE: Deduct 6 feet (1.8 m) for each additional elbow.
Ta bl e 1
NOTE: The maximum length of a 4 in. (10.2 cm) diameter flexible metal duct must not exceed
7.87 ft. (2.4 m), as required to meet UL2158, clause
7.3.2A.
513005
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
11
Page 14
Installation
2
1
3
METERED MODELS ILLUSTRATED
24 IN. (61 CM)
MINIMUM
CLEARANCE TO
ROOF/GROUND
Multi-Dryer Installation Exhaust Requirements
Figure 6 shows a typical example of a multiple dryer installation. Note how each dryer has its own exhaust system vented to the central exhaust duct.
1 58786 Backdraft Damper (Available through
your local authorized parts source)
2 Clean Out Cover (Must be provided). Inspect
monthly.
Figure 6
DRY2358N
3 Weather Hood or Sweep Elbow
(No cap or screen)
12
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
513005
Page 15
1 NOTE: Where the exhaust duct pierces a
D686I
2
3
4
EXHAUST
OUTLET
KJIHGFEDCBA
5
30°
1
24 in. (61 cm)
MINIMUM
CLEARANCE TO
ROOF/GROUND
EXHAUST AIR FLOW
MAXIMUM LENGTH OF DUCT
30 feet (9.1 m)
HORIZONTAL EXHAUST INSTALLATION
AIR
FLOW
3
1
4
5
24 in. (61 cm)
MINIMUM
CLEARANCE TO
ROOF/GROUND
CONNECT TO DRYER
VERTICAL EXHAUST INSTALLATION
2
To reduce the risk of fire and the accumulation of combustion gases, DO NOT exhaust dryer air into a window well, gas vent, chimney or enclosed, unventilated area, such as an attic, wall, ceiling, crawl space under a building or concealed space of a building.
W045
WARNING
combustible wall or ceiling, the opening must be sized per local codes.
3 2 in. (5 cm) Minimum or Clearance per Local
Codes
4 No Screen or Cap
2 Wall 5 Clean Out Cover
Inspect Monthly
Installation
D686I
1 Roof 2 No Screen or Cap 3 Wall 4 2 in. (5 cm) Minimum 5 NOTE: Where the exhaust duct pierces a
combustible wall or ceiling, an opening must be sized as shown or per local codes.
Figure 8
513005
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Figure 7
D753I
13
Page 16
Installation
To reduce the risk of gas leaks, fire or explosion:
• The dryer must be connected to the type of gas as shown on nameplate located in the door recess.
• Use a new flexible stainless steel connector.
• Use pipe joint compound insoluble in L.P. (Liquefied Petroleum) Gas, or Teflon tape, on all pipe threads.
• Purge air and sediment from gas supply line before connecting it to the dryer. Before tightening the connection, purge remaining air from gas line to dryer until odor of gas is detected. This step is required to prevent gas valve contamination.
• Do not use an open flame to check for gas leaks. Use a non-corrosive leak detection fluid.
• Any disassembly requiring the use of tools must be performed by a suitably qualified service person.
W316
WARNING
Duct Station
A 4 inches (10.2 cm)
B 8 inches (20.3 cm)
C 9 inches (22.9 cm)
D 10 inches (25.4 cm)
E 11 inches (27.9 cm)
F 12 inches (30.5 cm)
G 13 inches (32.6 cm)
H 14 inches (35.6 cm)
I 15 inches (38.1 cm)
J 15 inches (38.1 cm)
K 16 inches (40.6 cm)
Minimum Diameter of
Collector Duct
A Backdraft Damper, Part No. 58786 (obtain locally), should be installed in a 4 inch (10.2 cm) diameter VERTICAL duct system. This will prevent a backdraft when dryer is not in use, and will keep the exhaust air in balance within the central exhaust system.
Step 3: (Gas Dryer Only) Connect Gas Supply Pipe
1. Make certain your dryer is equipped for use with the type of gas in your laundry room. Dryer is equipped at the factory for Natural Gas with a 3/8 inch NPT gas connection.
NOTE: The gas service to a gas dryer must conform with the local codes and ordinances, or in the absence of local codes and ordinances, with the latest edition of the National Fuel Gas Code ANSI Z223.1/NFPA 54 or the CAN/CSA-B149.1 Natural Gas and Propane Installation Code.
3
Natural Gas, 1000 Btu/ft
(37.3 MJ/m3) service must be supplied at minimum 5.0 inch water column pressure to maximum 10.5 inch water column pressure.
For proper operation at altitudes above 2000 feet (610 m) the natural gas valve spud orifice size must be reduced to ensure complete combustion. Refer to Ta bl e 2 .
Natural Gas Altitude Adjustments
Altitude Orifice Size
feet m # inches mm
2,000 610 41 0.0960 2.44 503776
Part
Number
14
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
3,000 915 42 0.0935 2.37 503777
5,500 1,680 43 0.0890 2.26 503778
7,000 2,135 44 0.0860 2.18 58719
9,000 2,745 45 0.0820 2.08 503779
10,500 3,200 46 0.0810 2.06 503780
Tab le 2
2. Remove the shipping cap from the gas connection at the rear of the dryer. Make sure you do not damage the pipe threads when removing the cap.
3. Connect to gas supply pipe.
513005
Page 17
NOTE: When connecting to a gas line, an
D233I
1
3
2
4
5
To reduce the risk of fire, electric shock, serious injury or death, all wiring and grounding MUST conform with the latest edition of the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1, and such local regulations as might apply. It is the customer’s responsibility to have the wiring and fuses installed by a qualified electrician to make sure adequate electrical power is available to the dryer.
W521
WARNING
equipment shut-off valve must be installed within 6 feet (1.8 m) of the dryer. An 1/8 in. NPT pipe plug must be installed as shown for checking inlet pressure. Refer to Figure 9.
Installation
L.P. Altitude Adjustments
Altitude Orifice Size
feet m No. inches mm
3500 1070 54 0.0550 1.40 503785
7500 2290 55 0.0520 1.32 58755
11000 3355 56 0.0465 1.18 503786
Table 3
Part
No.
NOTE: DO NOT connect the dryer to L.P. Gas Service without converting the gas valve. Install L.P. Gas Conversion Kit 458P3, available at extra cost.
Step 4: (Electric Dryer Only) Connect Electrical Plug
Dryer requires 120/240 Volt or 120/208 Volt, 60 Hertz, 3 or 4 wire electrical suppy. Refer to serial plate for specific electrical requirements.
1 New stainless steel flexible connector –
(Use design CSA certified connector) Use only if allowed by local codes
2 1/8 in. NPT Pipe Plug 3 Equipment Shut Off Valve 4 Black Iron Pipe
Shorter than 20 ft. (6.1 m) – Use 3/8 in. (9.5 mm) pipe. Longer than 20 ft. (6.1 m) – Use 1/2 in. (12.7 mm) pipe.
5 3/8 in. NPT Gas Connection
Figure 9
4. Tighten all connections securely. Turn on gas and check all pipe connections (internal & external) for gas leaks with a non-corrosive leak detection fluid.
NOTE: The dryer and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.45 kPa). Refer to Step 9 (Check Heat Source).
L.P. (Liquefied Petroleum) Gas, 2500 Btu/ft
(93.1 MJ/m water column pressure.
3
) service must be supplied at 10 ± 1.5 inch
For proper operation at altitudes above 3500 feet (1070 m) the L.P. gas valve spud orifice size must be reduced to ensure complete combustion. Refer to Table 3.
513005
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
D233I
NOTE: The wiring diagram is located inside the control hood.
Grounding Information
This appliance must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. The cord-kit must be
3
equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
15
Page 18
Installation
Improper connection of the equipment­grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the dryer is properly grounded.
W038
WARNING
Do not modify the plug provided with the cord-kit - if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
The dryer has its own terminal block that must be connected to a separate branch, 60 Hertz, single phase circuit, AC (alternating current) circuit, fused at 30 Amperes (the circuit must be fused on both sides of the line). Electrical service for the dryer should be
of maximum rated voltage (208 or 240 Volt, depending on heating element) listed on the nameplate. Do not connect dryer to 110, 115, or 120 Vol t c irc ui t .
Heating elements are available for field installation in dryers which are to be connected to electrical service of different voltage than that listed on nameplate, such as 208 Volt.
NOTE: Branch circuit wire size requirements to laundry room outlet are shown in Tab le 4 .
Wire Length Wire
Less than
15 ft. (4.5 m)
Longer than
15 ft.(4.5 m)
Table 4
Listed No. 10 AWG
Copper wire only
Listed No. 8 AWG
Copper wire only
The power cord connection between wall receptacle and dryer terminal block IS NOT supplied with dryer. Type of power cord and gauge of wire must conform to local codes.
16
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
513005
Page 19
IMPORTANT: Use only a new U.L. listed No. 10
D275I
1
2
3
4
THREE-WIRE
1
2
3
4
FOUR-WIRE
D679I
1
8
7
6
5
4
3
2
THREE-WIRE CONNECTION
D680I
1
8
7
6
10
4
3
1
11
9
FOUR-WIRE CONNECTION
(copper wire only) three or four conductor power supply cord kit rated 240 Volts (minimum) 30 Amperes and labeled as suitable for use in a clothes dryer.
Installation
D275I
D006I
D679I
1 Typical Receptacle 2 Power Cord 3 Strain Relief Nut 4 Strain Relief
D680I
Figure 10
NOTE: DRYER IS SHOWN WITH ACCESS COVER REMOVED FOR ILLUSTRATION PURPOSES ONLY. NEVER OPERATE THE DRYER WITH ACCESS COVER REMOVED.
1 Ground Wire 2 Ground to Neutral Wire 3 Neutral Terminal 4 “L2” Terminal 5 Center Wire (Neutral) 6 Strain Relief (Not supplied with dryer) 7 Ground Screw 8 “L1” Terminal
9 Black Wire 10 White Wire (Neutral) 11 Red Wire
Figure 11
513005
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
17
Page 20
Installation
NOTE: THE POWER CORD IS NOT SUPPLIED WITH THE ELECTRIC DRYER. TYPE OF POWER CORD AND GAUGE OF WIRE MUST CONFORM TO LOCAL CODES AND INSTRUCTIONS.
THE METHOD OF WIRING THE DRYER IS OPTIONAL AND SUBJECT TO LOCAL CODE REQUIREMENTS.
NOTE: CONNECT THE DRYER TO THE POWER SUPPLY WITH THE MAXIMUM RATED VOLTAGE LISTED ON THE NAMEPLATE.
1
3
5
6
7
4
2
POWER CORD CONNECTION
DIRECT CONNECTION
L1 L2
L1 L2
INTERMEDIATE SHUT-OFF BOX
(may or may not
be fused)
POWER SUPPLYPOWER SUPPLY
INTERMEDIATE
FUSE BOX (may
be omitted if
service entrance
box is fused)
WALL
RECEPTACLE
A typical
30-Amp Three-Wire Receptacle
NEMA Type
10-30R
120 ± 12
V.A .C
.
120 ± 12
V.A.C.
240 ± 12
V.A.C.
NOTE: USE COPPER WIRE ONLY. SHORTER THAN 15 FT. (4.5 M) – USE 10 AWG LONGER THAN 15 FT. (4.5 M) – USE 8 AWG
Connecting Power Cord with Three-Wire Plug
NOTE: Four-wire cord is required for new branch­circuit installations, mobile homes or where codes do not permit grounding through neutral.
1 3 Wire Grounded Neutral 120/240 Volt, 60 Hertz
AC 1 Phase Service Entrance Switch Box
(Refer to NOTE above)
2 30 Ampere Fuses or Circuit Breaker 6 Neutral 3 Neutral Wire 7 Terminal Block in Dryer
1. Disconnect power to dryer.
2. Remove access cover from rear of dryer.
18
Figure 13
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
D695I
Figure 12
D816I
4 Metallic or Non-Metallic Sheathed Cable
(Copper Wire Only)
5 Power Cord (Not supplied with dryer)
3. Use a strain relief and insert end of power cord through power supply hole.
Figure 14
D696I
513005
Page 21
Installation
1
2
3
120 ± 12
V.A.C.
120 ± 12
V.A.C.
120 ± 12
V.A.C.
120 ± 12
V.A.C.
240 ± 12
V.A.C.
0
V.A.C.
1
2
3
4
4. Use the three screws from the accessories bag to attach the power cord wires to the terminal block. Refer to Figure 15.
1 “L1” Terminal 2 Neutral Terminal 3 “L2” Terminal
Figure 15
5. Tighten all screws firmly.
IMPORTANT: Failure to tighten these screws firmly may result in wire failure at the terminal block.
Connecting Power Cord with Four-Wire Plug
NOTE: Four-wire cord is required for new branch­circuit installations, mobile homes or where codes do not permit grounding through neutral.
D286I
DRY2016N
1 Typical Four-Wire Receptacle 2 Power Cord – Not Supplied with Dryer 3 Strain Relief Nut 4 Strain Relief
6. Secure the strain relief to the power cord, or wires, where they enter the dryer cabinet.
7. Check the continuity of the ground connection before plugging the cord into an outlet. Use an acceptable indicating device connected to the center grounding pin of the plug and the green screw on the back of the cabinet.
8. Reinstall access cover and screw.
513005
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Figure 16
19
Page 22
Installation
1
DRY1920N
5
7
1
2
4
6
3
1. Disconnect power to dryer.
2. Remove access cover from rear of dryer.
D695I
Figure 17
3. Remove ground screw and save for use in Step 5. Remove wire and use in Step 6.
5. Attach power cord ground (green) wire to rear bulkhead using ground screw removed in Step 3.
DRY1920N
1 White 2 “L2” Terminal 3 Black 4 Green 5 Red 6 Neutral Terminal 7 “L1” Terminal
1 Ground Screw
Figure 18
4. Use a strain relief and insert end of power cord through power supply hole.
20
Figure 19
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
D697I
D696I
Figure 20
6. Use the three screws from the accessories bag to attach the remaining power cord wires to the terminal block as follows:
a. Red wire to “L1” terminal.
b. Black wire to “L2” terminal.
c. White wire to Neutral terminal.
NOTE: When installing the white wire, loop the free eyelet end of the ground wire (removed in Step 3) and attach along with the white wire to the neutral (center) terminal on the terminal block.
7. Tighten all screws firmly.
IMPORTANT: Failure to tighten these screws firmly may result in wire failure at the terminal block.
8. Secure the strain relief to the power cord, or wires, where they enter the dryer cabinet.
9. Check the continuity of the ground connection before plugging the cord into an outlet. Use an acceptable indicating device connected to the center grounding pin of the plug and the green screw on the back of the cabinet.
10. Reinstall access cover and screw.
513005
Page 23
Installation
D675I
D675I
D272P
DRY1916N
B
A
DRY1916N
D273P
DRY1917N
DRY1917N
DRY1918N
B
A
DRY1918N
DRY1919N
DRY1919N
Step 5: Reverse Door, if Desired
The door on this dryer is completely reversible. To reverse door proceed as follows:
1. Remove four hinge attaching screws.
Figure 21
2. Remove all nine screws.
4. Rotate door panel 180 degrees as shown.
Figure 24
5. Remove door strike from door liner and reinstall on opposite side.
Figure 22
3. Pull bottom of door liner out, then pull down, removing door liner from door panel.
Figure 23
Figure 25
6. Insert liner under flange on bottom of door, then push top of door liner into place.
Figure 26
7. Reinstall nine screws removed in Step 2.
Figure 27
513005
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
21
Page 24
Installation
D317S
D317S
D606I
D606I
D604I
Connect to 30 Amp circuit.
To reduce the risk of fire, electric shock, serious injury or death, all wiring and grounding MUST conform with the latest edition of the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1, and such local regulations as might apply. It is the customer’s responsibility to have the wiring and fuses installed by a qualified electrician to make sure adequate electrical power is available to the dryer.
W521
WARNING
8. Using screwdriver, remove two door plugs, and reinstall on opposite side of door opening.
Figure 28
9. Reinstall four hinge attaching screws, removed in Step 1.
Step 7: Plug In the Dryer
Electric Dryer
Connect the dryer to an electrical power source. Refer to Step 4 for information on connecting power cord.
D275I
Figure 31
Gas Dryer
Dryer requires 120 Volt, 60 Hertz electrical supply and comes equipped with a 3-prong grounding plug. Refer to serial plate for specific electrical requirements.
Figure 29
Step 6: Wipe Out Inside of Dryer
Before using dryer for the first time, use an all-purpose cleaner, or a detergent and water solution, and a damp cloth to remove shipping dust from inside dryer drum.
22
Figure 30
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
D604I
NOTE: The wiring diagram is located inside the control hood.
When plugging in the dryer:
Do not overload circuits.
Do not use an adapter.
Do not use an extension cord.
Do not operate both a washer and gas dryer on
the same circuit. Use separately fused 15 amp circuits.
513005
Page 25
Installation
This dryer is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug.
W036
WARNING
Improper connection of the equipment­grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the dryer is properly grounded.
W038
WARNING
To reduce the risk of an electric shock or fire, DO NOT use an extension cord or an adapter to connect the dryer to the electrical power source.
W037
WARNING
D254I
DRY2
0 V.A.C
120±12
V.A.C
Plug cord into separately fused
15 Amp circuit.
3
2
1
4
5
120±12
V.A .C
The dryer is designed to be operated on a separate branch, polarized, three-wire, effectively grounded, 120 Volt, 60 Hertz, AC (alternating current) circuit protected by a 15 Ampere fuse, equivalent fusetron or circuit breaker.
The three-prong grounding plug on the power cord should be plugged directly into a polarized three-slot effectively grounded receptacle rated 120 Volts AC (alternating current) 15 Amps. Refer to Figure 32 to determine correct polarity of the wall receptacle.
Grounding Information
The dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. The dryer is equipped with a cord having an equipment-grounding conductor and a 3 prong grounding plug. The three-prong grounding plug on the power cord should be plugged directly into a polarized three-slot effectively grounded receptacle rated 110/120 Volts AC (alternating current) 15 Amps.
Do not operate other appliances on the same circuit when this appliance is operating.
Do not modify the plug provided with the dryer – if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
NOTE: Have a qualified electrician check the polarity of the wall receptacle. If a voltage reading is measured other than that illustrated, the qualified electrician should correct the problem.
513005
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
DRY2022N
1 “L1” 2 Ground 3 Neutral 4 Neutral Side 5 Round Grounding Prong
Figure 32
23
Page 26
Installation
For personal safety, lower front panel must be in place during normal operation.
W046
WARNING
1
4
3
6
2
5
Step 8: Recheck Steps 1-7
Refer to Installer Checklist on the back cover of this manual and make sure that dryer is installed correctly.
Step 9: Check Heat Source
Electric Dryers
Close the loading door and start the dryer in a heat setting (refer to the Operation section). After the dryer has operated for three minutes, the exhaust air or exhaust pipe should be warm.
Gas Dryers
IMPORTANT: This operation is to be conducted by qualified personnel only.
To view the burner flame, remove the lower front panel of the dryer.
Close the loading door, start the dryer in a heat setting (refer to the Operation section). The dryer will start, the igniter will glow red and the main burner will ignite.
IMPORTANT: If all air is not purged out of gas line, gas igniter may go off before gas is ignited. If this happens, after approximately two minutes igniter will again attempt gas ignition.
IMPORTANT: If igniter does not light, make sure gas is turned on.
After the dryer has operated for approximately five minutes, observe burner flame through lower front panel. Adjust the air shutter to obtain a soft, uniform blue flame. (A lazy, yellow-tipped flame indicates lack of air. A harsh, roaring, very blue flame indicates too much air.) Adjust the air shutter as follows:
1. Loosen the air shutter lockscrew.
2. Turn the air shutter to the left to get a luminous yellow-tipped flame, then turn it back slowly to the right to obtain a steady, soft blue flame.
3. After the air shutter is adjusted for proper flame, tighten the air shutter lockscrew securely.
4. Reinstall the lower front panel.
After the dryer has operated for approximately three minutes, exhaust air or exhaust pipe should be warm.
1 Closed Position 5 1/8 in. (3.1 mm) Pipe Plug 2 Shut-Off Valve Handle (For checking manifold pressure) 3 Air Shutter Lockscrew 6 Open Position 4 Air Shutter
24
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
DRY2235N
Figure 33
513005
Page 27
Vending
1
Meter Case
(Metered Models)
The factory mounted coin meter case does not include the service door lock, coin drawer, coin drawer lock and keys. These parts must be ordered (at extra cost) according to the purchaser’s requirements direct from the manufacturer of your choice.
NOTE: On models with standard capacity meter case and high capacity meter case models starting with Serial Nos. beginning 1010, you have the option of using a screw type lock or a 1/4 turn lock on the meter case service door. If you choose to use a screw lock, then the special bracket (located inside the meter case) must be used. DO NOT use the special bracket if a 1/4 turn lock is used. High capacity meter case models with Serial Nos. beginning 0910 through 1010 use 1/4 turn lock only.
Coin Drawer Security (Models with standard capacity meter case and high capacity meter case models starting with Serial Nos. beginning 1010) –
for additional security, drill out the two pilot holes on each front side of the meter case to 1/4 or 5/16 inch (6.4 or 8.0 mm) holes and install a bicycle lock through these holes.
Additional Dryer Security
Located on the service door of the dryer is a flat Phillips head screw. During shipment, this screw is used to attach the service door to the meter case. For additional security, this screw can be reinstalled inside the control hood of your dryer. Following is the procedure for installing this screw:
1. Remove the Phillips head screw from service door. (Refer to Figure 34.)
2. Remove two screws holding control panel to control hood.
3. Tilt control panel forward and lay on a protective pad to prevent scratching of cabinet top.
4. Insert Phillips head screw down through double “D” hole in left rear corner of cabinet top (inside control hood) until it engages retainer nut located on left rear corner gusset of cabinet.
5. Finger tighten screw.
IMPORTANT: Do not use a power driver to tighten screw. Torque of a power driver could over-tighten screw causing damage to cabinet assembly.
513005
1 Double “D” Hole
Figure 34
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
DRY2359N
25
Page 28
Operation
To reduce the risk of fire, electric shock, or injury to persons, read the IMPORTANT SAFETY INSTRUCTIONS before operating this appliance.
W727
WARNING
D608I
D609I
D688I
Operation Instructions
IMPORTANT: Before using dryer for the first time, use an all-purpose cleaner, or a detergent and water solution, and a damp cloth to remove shipping dust from inside of dryer drum.
IMPORTANT: Remove all sharp objects from laundry to avoid tears and rips to items during normal machine operation.
Step 1: Clean Lint Filter
Clean lint filter before each use.
Step 2: Load Laundry
Load clothes loosely into dryer drum. Add fabric softener sheet if desired.
IMPORTANT: To avoid damage to dryer, do not use more than one fabric softener sheet per load.
D609I
Figure 36
Step 3: Close Loading Door
Close loading door. Dryer will not operate with the door open.
Figure 35
26
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 513005
D608I
D688I
Figure 37
Page 29
Operation
Step 4: Set Fabric Selector
Select HIGH TEMP, MED TEMP, LOW TEMP, DELICATES or NO HEAT by pushing touchpad.
DRY2320N
Figure 38
NOTE: Always follow manufacturer’s care label instructions.
Step 5: Insert Coin(s) or Card
To Insert Money
Insert coin(s) in coin slot. Check pricing as seen on digital display.
To Insert Card
Insert card into opening.
DRY1927N
Figure 40
If Additional Time Feature is turned on, additional dryer time may be purchased at cycle start or while dryer is running.
Remove knits when slightly damp because overdrying may cause shrinkage. Do not tumble dry knit woolens.
513005
W387I
Figure 39
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
27
Page 30
Operation
Step 6: Start Dryer
To start dryer, push START pad.
To stop dryer at any time, open the door. To restart the dryer, close door and push START pad.
Cycle is completed when time remaining reaches 00 minutes.
DRY2321N
Figure 41
NOTE: This machine includes an extended tumble feature. Starting 20 minutes after a cycle ends, the cylinder will tumble for two minutes every hour without heat, up to 18 hours or until door is opened.
Indicator Lights
INSERT COINS/CARD
INSERT COINS/CARD is lit to prompt the user to insert coins or a card to satisfy the vend price. When INSERT COINS/CARD is lit, the three digits will display the vend price remaining to be satisfied.
START
START is lit whenever the dryer is not in a cycle, the full vend price has been satisfied and the dryer door is closed. When the START pad is pressed, the cycle will begin or resume.
DRYING
DRYING is lit to indicate that one of the heated cycles (HIGH TEMP, MED TEMP, LOW TEMP or DELICATES) is currently in operation. DRYING will turn off at the end of a heated cycle or when the COOL DOWN cycle begins.
COOL DOWN
COOL DOWN is lit whenever the COOL DOWN portion of a heated cycle is active. It is also lit when the NO HEAT cycle is in operation.
28
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
513005
Page 31
Maintenance
To reduce the risk of an electric shock, serious injury or death, disconnect the electrical service to the dryer before cleaning the interior.
W132
WARNING
Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
W049
WARNING
To reduce the risk of electric shock, disconnect the electrical service to the dryer before cleaning.
W043
WARNING
Lubrication
All moving parts are sealed in a permanent supply of lubricant or are equipped with oilless bearings. Additional lubrication will not be necessary.
Care of Your Dryer
Dryer Interior
Wipe the surfaces using a soft cloth and household cleaner or a non-abrasive paste of powdered laundry detergent and hot water, followed by a short heat cycle with a load of rags.
To remove crayon or ball point ink off the dryer drum, put the heat on high and use old rags in the dryer to absorb the crayon or ink. If unsuccessful, contact the appliance dealer. DO NOT use any chemicals in the dryer.
Exhaust System
The exhaust duct should be inspected after one year of use and cleaned if necessary by a qualified service person to remove any lint build-up. Inspect and clean exhaust duct every one to two years as required thereafter.
The weather hood should be checked frequently to make sure the dampers move freely, dampers are not pushed in and that nothing has been set against them.
Keep dryer area clear and free from combustible materials, gasoline and other flammable vapors and liquids.
Do not obstruct the flow of combustion and ventilation air.
NOTE: Verify proper operation after servicing.
IMPORTANT: The use of chlorine bleach for removing any discolorations should be avoided because bleach could damage the finish.
Cabinet
Wipe the dryer cabinet as needed. If detergent, bleach or other washing products have been spilled on the dryer, wipe immediately. Some products will cause permanent damage if spilled on the cabinet.
Control Panel
Use only a damp or sudsy cloth for cleaning the control panel. Some spray pretreat products may harm the finish on the control panel.
NOTE: The wiring diagram is located inside the control panel.
513005
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
29
Page 32
Maintenance
D608I
1
Lint Filter
CLEAN THE LINT FILTER BEFORE DRYING EACH LOAD. (Refer to Figure 42 for lint filter location.) Cleaning the lint filter is important because a layer or pad of lint on the filter will block the flow of air through the dryer, thus reducing the efficiency of the dryer. The clothes will take longer to dry and energy will be wasted.
The lint filter may be washed if needed. Annually remove lint filter and screw to vacuum the duct under it.
D608I
1 Lint Filter
For Energy Conservation
Make sure the lint filter is always clean.
Do not overload dryer.
Do not overdry clothes.
Remove items to be ironed while still damp.
Large loads of similar fabrics dry the most
efficiently. However, dry permanent press in smaller loads to prevent wrinkling.
Use the correct temperature FABRIC
SELECTOR setting for the type of fabric being dried.
Locate your dryer so the exhaust duct is as short
and straight as possible.
Do not open the door during the drying cycle.
Plan to do your laundry on low humidity days;
your clothes will dry faster.
Should you plan to dry several loads, do them
one after another, then you do not have to reheat the dryer unit’s interior parts each time.
Figure 42
Motor Overload Protector
The dryer’s motor overload protector stops the motor automatically in the event of an overload. After cooling, the overload protector will reset itself. Dryer can be restarted by pressing the START pad. If overload protector cycles again, remove the dryer from use and call the service person to correct the problem.
30
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
513005
Page 33
Troubleshooting
Try these troubleshooting tips before making a service call. They may save you time and money.
Dryer Symptom Possible Cause/Solution
Dryer won’t start
Dryer won’t heat
Dryer doesn’t dry clothes satisfactorily
Insert coin(s) or card.
For dryers equipped with a power cord, make sure the power cord is plugged all the way into the electrical outlet.
Make sure loading door is closed.
Press START pad.
Make sure the laundry room fuse(s) isn’t blown or loose, or circuit breakers aren’t open. The dryer itself does not have an electrical fuse. An electric dryer has an electrical circuit with two fuses.
Check if motor overload protector has cycled. Wait 10 minutes and try again.
Make sure the laundry room fuse(s) isn’t blown or loose, or circuit breakers aren’t open. The dryer itself does not have an electrical fuse. An electric dryer has an electrical circuit with two fuses.
Make sure controls are in a HEAT setting.
Gas dryer only – Make sure equipment and main gas line valve is turned on.
Check exhaust duct to outside to see if it is kinked, blocked or needs cleaning.
Check weather hood to make sure flapper moves freely, has not been pushed in or has not been blocked.
Check exhaust duct to outside to see if it is kinked, blocked or needs cleaning.
Check weather hood to make sure flapper moves freely, has not been pushed in or has not been blocked.
Clean the lint filter.
Make sure the load isn’t too small. Small loads may not tumble properly or dry evenly.
Check load being dried. Heavy items dried with lightweight items will not dry as quickly as the rest of the load.
Dryer is noisy
Clothes are too wrinkled
Clothes have odor
Check dryer for foreign objects (nails, coins, bobby pins, metal, plastic toys, etc.). Remove items from dryer.
Make sure dryer is level. Uneven leveling can cause vibration.
Normal operating sounds include the tick of timer advancing, heat source going on and off, and humming of air moving through the dryer and exhaust system.
Check heat setting. Overdrying can cause wrinkling.
Check load size. Large loads may not tumble properly and may cause wrinkling.
Check room for odors before drying clothes. Any odor (fried foods, paint, varnish, cleaners, burning wood, etc.) will transfer to clothing as the dryer draws air from the room. Ventilate room before drying clothes.
513005
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
31
Page 34
Contact Information
1
To reduce the risk of serious injury or death, DO NOT repair or replace any part of the dryer or attempt any servicing unless specifically recommended in the user-maintenance instructions or in published user-repair instructions that you understand and have the skills to carry out.
W133
WARNING
If service is required, contact the nearest Factory Authorized Service Center.
If you are unable to locate an authorized service center or are unsatisfied with the service performed on your dryer, contact:
Alliance Laundry Systems Shepard Street P. O . B o x 9 90 Ripon, WI 54971-0990 U.S.A. www. comlaundry. com Phone: (920) 748-3121
Date Purchased ___________________________
Model Number ___________________________
Serial Number ___________________________
When calling or writing about your dryer, PLEASE GIVE THE MODEL AND SERIAL NUMBERS
The model and serial numbers are located on the nameplate. The nameplate will be in the location shown in the illustration below. Please include a copy of your bill of sale and any service receipts you have.
.
If replacement parts are required, contact the source from which you purchased your dryer or contact us at (920) 748-3950 for the name and address of the nearest authorized parts distributor.
1 Nameplate
Figure 43
32
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 513005
D063K
Page 35
Page 36
Installer Checklist
LEVEL
D255I
• Position and Level the Dryer.
1
D256I
CHECK
D259I
D255I
DRY2357N
2
CHECK
• Connect Dryer Exhaust System.
DRY2357NDRY2356N
3
GAS ONLY
D258I
CHECK
• Connect Gas Supply Pipe.
• Check for Gas Leaks.
4
D699I
W315IE0A
ELECTRIC ONLY
• Connect Electrical Cord.
CHECK
• Reverse Door, if Desired.
5
D675I
CHECK
W675I
6
D610I
•Wipe Out Inside of Dryer.
D610I
CHECK
7
D254I
D275I
D254I
CHECK
Electric
Gas
• Plug In the Dryer.
• Recheck Steps 1-7.
8
CHECK
9
CHECK
DRY2235N
• Check Heat Source.
DRY2235N
Fast Track for Installing the Dryer
(Refer to the manual for more detailed information)
D275I
DRY2356N
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Loading...