Alliance Laundry Systems CA120N, DR120G2-, CK120N, CT120L, CT120N Installation & Operation Manual

...
Tumble Dryers
TMB1268C_SVG
120 Pound (54 Kilogram) Capacity 170 Pound (77 Kilogram) Capacity 200 Pound (91 Kilogram) Capacity
Starting Serial No. 0907003062
Refer to Page 8 for Model Identification
Installation/Operation/Maintenance
Original Instructions Keep These Instructions for Future Reference.
(If this machine changes ownership, this manual must accompany machine.)
www.alliancelaundry.com
Part No. 70458101ENR9
September 2014
Front Matter
Front Matter
Installation must conform with local codes or, in the absence of local codes, with:
In the U.S.A., installation must conform to the latest edition of the American National Standard Z223.1/ NFPA 54 “National Fuel Gas Code” and Standard ANSI/NFPA 70 “National Electric Code.”
In Canada, installation must comply with Standards CAN/CSA-B149.1 or Natural Gas and Propane Installation Code and CSA C22.1, latest edition, Canadian Electric Code, Part I.
In Australia and New Zealand, installation must comply with the Gas Installations Standard AS/NZS 5601 Part 1: General Installa­tions.
WARNING
FOR YOUR SAFETY, the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury or death.
W033
WARNING
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appli­ance.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Clear the room, building or area of all occupants.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
W052
IMPORTANT: Information must be obtained from a local gas supplier on instructions to be followed if the user smells gas. These instructions must be posted in a prominent location. Step-by-step instructions of the above safety information must be posted in a prominent location near the tumble dryer for customer use.
IMPORTANT: The installer must fully test the tumble dryer after installation and demonstrate to the owner how to operate the machine.
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumble dryer before servicing.
Close gas shut-off valve to gas tumble dryer before servicing.
Close steam valve to steam tumble dryer before servicing.
Never start the tumble dryer with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the tumble dryer is properly grounded.
Part No. 70458101ENR9
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 3
W002R1
Front Matter
WARNING
Installation of unit must be performed by a qualified installer.
Install tumble dryer according to manufacturer’s instructions and local codes.
DO NOT install a tumble dryer with flexible plastic venting materials. If flexible metal (foil type) duct is instal­led, it must be of a specific type identified by the appliance manufacturer as suitable for use with tumble dryer. Refer to section on connecting exhaust system. Flexible venting materials are known to collapse, be easily crushed, and trap lint. These conditions will obstruct tumble dryer airflow and increase the risk of fire.
W752R1
The following information applies to the state of Massachusetts, USA.
This appliance can only be installed by a Massachusetts licensed plumber or gas fitter.
This appliance must be installed with a 36 inch [91 cm] long flexible gas connector.
A “T-Handle” type gas shut-off valve must be installed in the gas supply line to this appliance.
This appliance must not be installed in a bedroom or bathroom.
4
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458101ENR9
Table of Contents
Introduction........................................................................................... 8
Model Identification .......................................................................................8
Contact Information...................................................................................... 10
Safety Information................................................................................11
Explanation of Safety Messages..................................................................... 11
Important Safety Instructions......................................................................... 11
Specifications and Dimensions.............................................................. 13
Specifications and Dimensions ...................................................................... 13
120 Series Tumble Dryer Dimensions and Exhaust Outlet Locations ................ 14
170 and 200 Series Tumble Dryer Dimensions and Exhaust Outlet Locations.....16
Electric and Gas Connection Locations for Gas Models Through 3/10/13...........17
Electric and Gas Connection Locations for Gas Models Starting 3/11/13............17
Electric and Steam Connection Locations for Steam Models Through 3/10/13....18
Electric and Steam Connection Locations for Steam Models Starting 3/11/13.....19
Electric Connection Location for Electric Models............................................ 20
Installation........................................................................................... 22
Pre-Installation Inspection............................................................................. 22
Location Requirements..................................................................................22
Position and Level the Tumble Dryer..............................................................23
Fire Suppression System (Optional Equipment)............................................... 23
Check Local Codes and Permits..................................................................23
Water Requirements.................................................................................. 24
Water Connections.................................................................................... 24
Electrical Requirements............................................................................. 25
Auxiliary Alarm........................................................................................ 25
Before Placing Tumble Dryer into Service...................................................... 26
Required for CE Models Only.................................................................... 27
Installing CE Gas Drying Tumble Dryer......................................................... 27
General Information.................................................................................. 27
CE Orifices...............................................................................................28
Properties of CE Gases.............................................................................. 30
Changing Gas Configuration...................................................................... 30
Specific Conversion Procedures..................................................................31
Exhaust Requirements..........................................................................33
Exhaust Requirements...................................................................................33
Layout......................................................................................................... 33
©
Copyright 2014, Alliance Laundry Systems LLC All rights reserved. No part of the contents of this book may be reproduced or transmitted in any form or by any means without the expressed written consent of the publisher.
Part No. 70458101ENR9
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 5
Make-Up Air................................................................................................33
Venting........................................................................................................33
Alternate Venting for 120 Series Tumble Dryers.......................................... 34
Individual Venting.....................................................................................35
Manifold Venting...................................................................................... 35
Gas Requirements.................................................................................38
Gas Requirements.........................................................................................38
Gas Supply Pipe Sizing and Looping.............................................................. 40
High Altitude Orifice Sizing ......................................................................... 42
Electrical Requirements........................................................................45
Electrical Requirements.................................................................................45
Wiring Diagram............................................................................................45
Grounding Instructions..................................................................................45
For CE Models Only..................................................................................46
Service/Ground Location........................................................................... 46
To Connect Electrical Service To The Tumble Dryer....................................... 47
Jumper Configuration Instructions..................................................................48
Ferrite Ring Installation ................................................................................48
Electrical Specifications ............................................................................... 49
Steam Requirements.............................................................................52
Steam Requirements......................................................................................52
Piping Recommendations.............................................................................. 55
Installing Steam Trap and Making Condensate Return Connections...................55
Thermal Oil Prep.......................................................................................... 55
Operating Instructions..........................................................................56
Operating Instructions................................................................................... 56
Emergency Stop Button On CE Models.......................................................... 56
Operating Instructions................................................................................... 56
Reversing Operation......................................................................................57
Control Instructions.......................................................................................57
Dual Digital Timer Control........................................................................ 57
Electronic OPL Micro Control....................................................................58
LED OPL Control .................................................................................... 59
UniLinc Control ....................................................................................... 60
DX4 OPL Control..................................................................................... 61
Diagnostic Microprocessor Control ............................................................ 62
DMP OPL Models.....................................................................................62
Ignition Control Operation and Troubleshooting for Models Starting 3/11/13..... 64
Internal Control Failure..............................................................................65
Troubleshooting........................................................................................ 65
Proper Electrode Location..........................................................................66
Flame Current Measurement.......................................................................66
Ignition Control Operation for Non-CE Models Through 3/10/13...................... 66
Ignition Control Operation for CE Models Through 3/10/13............................. 66
System Tests.............................................................................................67
6
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458101ENR9
Diagnostic LED (DGN LED)/Error Codes...................................................67
Adjustments......................................................................................... 69
Adjustments................................................................................................. 69
Gas Burner Air Shutter.................................................................................. 69
Airflow Switch ............................................................................................ 70
Loading Door Switch.................................................................................... 70
Loading Door Catch (120 and 170 Series Models)........................................... 70
Loading Door Strike (200 Series Models)........................................................71
Belt Drive ................................................................................................... 71
Maintenance......................................................................................... 72
Daily........................................................................................................... 72
Monthly....................................................................................................... 72
Quarterly......................................................................................................72
Bi-Annually................................................................................................. 72
Annually...................................................................................................... 73
Fire Suppression System (Optional Equipment) Maintenance Test.................... 73
Before You Call for Service...................................................................75
Removing Tumble Dryer from Service..................................................76
Disposal of Unit.................................................................................... 77
Part No. 70458101ENR9
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 7
Introduction
Model Identification
Information in this manual is applicable to these models:
Gas Steam/Thermal Oil Electric
Introduction
120 Series CA120L
CA120N
CK120N
CT120L
CT120N
CU120L
CU120N
DR120G2-BA120L
DR120G2-BA120N
DR120G2-BK120N
DR120G2-BT120L
DR120G2-BT120N
DR120G2­BU120L
DR120G2­BU120N
HA120L
HA120N
HK120N
HT120L
HT120N
HU120L
HU120N
IPD120G2
IT120L
IT120N
SA120L
SA120N
SK120N
ST120L
ST120N
SU120L
SU120N
UA120L
UA120N
UK120N
UT120L
UT120N
UU120L
UU120N
XT120L
XT120N
XU120L
XU120N
YT120L
YT120N
CT120S
CT120T
CU120S
CU120T
DR120S2-BT120S
DR120S2-BT120T
DR120S2-BU120S
DR120S2-BU120T
HT120S
HT120T
HU120S
HU120T
IPD120S2
IT120S
IT120T
ST120S
ST120T
SU120S
SU120T
UT120S
UT120T
UU120S
UU120T
XT120S
XT120T
XU120S
XU120T
YT120S
YT120T
YU120S
YU120T
CT120E
CU120E
DR120E2-BT120E
DR120E2-BU120E
HT120E
HU120E
IT120E
ST120E
SU120E
UT120E
UU120E
YT120E
YU120E
YU120L
YU120N
Part No. 70458101ENR9
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 8
Gas Steam/Thermal Oil Electric
Introduction
170 Series CA170L
CA170N
CK170N
CT170L
CT170N
CU170L
CU170N
DR170G2-BA170L
DR170G2-BA170N
DR170G2-BK170N
DR170G2-BT170L
DR170G2-BT170N
DR170G2-BU170L
DR170G2-BU170N
HA170L
HA170N
HK170N
HT170L
HT170N
HU170L
HU170N
IPD170G2
IT170L
IT170N
SA170L
SA170N
SK170N
ST170L
ST170N
SU170L
SU170N
UA170L
UA170N
UK170N
UT170L
UT170N
UU170L
UU170N
XT170L
XT170N
XU170L
XU170N
YT170L
YT170N
YU170L
YU170N
CT170S
CT170T
CU170S
CU170T
DR170S2-BT170S
DR170S2-BT170T
DR170S2-BU170S
DR170S2-BU170T
HT170S
HT170T
HU170S
HU170T
IPD170S2
IT170S
IT170T
ST170S
ST170T
SU170S
SU170T
UT170S
UT170T
UU170S
UU170T
XT170S
XT170T
XU170S
XU170T
YT170S
YT170T
YU170S
YU170T
Not Applicable
200 Series CA200L
CA200N
CT200L
CT200N
CU200L
CU200N
DR200G2-BA200L
DR200G2-BA200N
DR200G2-BT200L
DR200G2-BT200N
DR200G2­BU200L
DR200G2­BU200N
HA200L
HA200N
HT200L
HT200N
HU200L
HU200N
IT200L
IT200N
Explanation of digit in 6th position of model number:
E = Electric
L = Liquid Petroleum (L.P.) Gas
N = Natural Gas
SA200L
SA200N
ST200L
ST200N
SU200L
SU200N
UA200L
UA200N
UT200L
UT200N
UU200L
UU200N
CT200S
CT200T
CU200S
CU200T
DR200S2-BT200S
DR200S2-BT200T
DR200S2-BU200S
DR200S2-BU200T
HT200S
HT200T
HU200S
HU200T
IT200S
IT200T
ST200S
ST200T
SU200S
SU200T
UT200S
UT200T
UU200S
UU200T
Not Applicable
S = Steam
Part No. 70458101ENR9
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 9
TMB2288N_SVG
1
120 170/200
1
Introduction
T = Thermal Oil
Includes models with the following control suffixes
R3 – reversing DX4 OPL RE – reversing LED OPL RQ – reversing dual digital timer
RD – reversing DMP OPL RM – reversing OPL micro RU – reversing UniLinc OPL
Contact Information
If service is required, contact the nearest Factory Authorized Service Center.
If you are unable to locate an authorized service center or are un­satisfied with the service performed on your unit, contact:
Alliance Laundry Systems Shepard Street P.O. Box 990 Ripon, WI 54971-0990 U.S.A. www.alliancelaundry.com Phone: +1 (920) 748-3121 Ripon, Wisconsin +32 56 41 20 54 Wevelgem, Belgium
When calling or writing about your unit, PLEASE GIVE THE MODEL AND SERIAL NUMBERS. The model and serial num­bers are located on the serial plate. The serial plate will be in the location shown in Figure 1 .
Date Purchased ______________________________
Model Number ______________________________
Serial Number _______________________________
Please include a copy of your bill of sale and any service receipts you have.
WARNING
To reduce the risk of serious injury or death, DO NOT repair or replace any part of the unit or attempt any servicing unless specifically recommended in the user-maintenance instructions or in published user-repair instructions that you understand and have the skills to carry out.
W329
If replacement parts are required, contact the source from where you purchased your unit or call +1 (920) 748-3950 or +32 56 41 20 54 for the name and address of the nearest authorized parts distributor.
1. Serial Plate
10
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458101ENR9
Figure 1
Safety Information
Safety Information
Explanation of Safety Messages
Precautionary statements (“DANGER,” “WARNING,” and “CAUTION”), followed by specific instructions, are found in this manual and on machine decals. These precautions are intended for the personal safety of the operator, user, servicer, and those maintaining the machine.
DANGER
Indicates an imminently hazardous situation that, if not avoided, will cause severe personal injury or death.
WARNING
Indicates a hazardous situation that, if not avoided, could cause severe personal injury or death.
CAUTION
Indicates a hazardous situation that, if not avoided, may cause minor or moderate personal injury or property damage.
Additional precautionary statements (“IMPORTANT” and “NOTE”) are followed by specific instructions.
IMPORTANT: The word “IMPORTANT” is used to in­form the reader of specific procedures where minor machine damage will occur if the procedure is not fol­lowed.
NOTE: The word “NOTE” is used to communicate in­stallation, operation, maintenance or servicing informa­tion that is important but not hazard related.
Important Safety Instructions
WARNING
To reduce the risk of fire, electric shock, serious in­jury or death to persons when using your tumbler, follow these basic precautions.
W776
Save These Instructions
Read all instructions before using the tumble dryer.
Install the tumble dryer according to the INSTALLATION in­structions. Refer to the EARTHING (grounding) instructions for the proper earthing (grounding) of the tumble dryer. All connections for electrical power, earthing (grounding) and gas supply must comply with local codes and be made by licensed personnel when required. It is recommended that the machine be installed by qualified technicians.
Do not install or store the tumble dryer where it will be ex­posed to water and/or weather. The tumble dryer cannot be used in a closed room where the air supply is insufficient. If necessary, ventilation grids must be installed in the doors or the windows.
This appliance must not be activated without lint/foam filter.
When you perceive a gas odor, immediately switch off the gas supply and ventilate the room. Do not switch on electrical ap­pliances and do not pull electrical switches. Do not use matches or lighters. Do not use a phone in the building. Warn the fitter, and if so desired, the gas company, as soon as possi­ble.
To avoid fire and explosion, keep surrounding areas free of flammable and combustible products. Regularly clean the dryer drum and exhaust tube should be cleaned periodically by competent maintenance personnel. Daily remove piled up dust from filter and inside of filter compartment.
Do not use or store flammable materials near this appliance.
Do not dry articles that have been previously cleaned in, washed in, soaked in or spotted with gasoline or machine oils, vegetable or cooking oils, cleaning waxes or chemicals, dry­cleaning solvents, thinner or other flammable or explosive substances as they give off vapors that could ignite, explode or cause fabric to catch on fire by itself.
Do not spray aerosols in the vicinity of this appliance while it is in operation.
Items such as foam rubber (latex foam), shower caps, water­proof textiles, rubber backed articles and clothes or pillows filled with foam rubber pads should not be dried in the tumble dryer. Do not use the appliance to dry materials with a low melting temperature (PVC, rubber, etc.).
Do not tumble fiberglass curtains and draperies unless the la­bel says it can be done. If they are dried, wipe out the cylinder with a damp cloth to remove particles of fiberglass.
Do not allow children on or in the tumble dryer. This appli­ance is not intended for use by young children or infirm per­sons without supervision. Young children should be super­vised to ensure that they do not play with the appliance.
Do not reach into the tumble dryer if the cylinder is revolving.
Use tumble dryer only for its intended purpose, drying fab­rics. Always follow the fabric care instructions supplied by the textile manufacturer and only use the dryer drum to dry textiles that have been washed in water. Only insert spin-dried linen in the dryer.
Part No. 70458101ENR9
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 11
Safety Information
Always read and follow manufacturer’s instructions on pack­ages of laundry and cleaning aids. Heed all warnings or pre­cautions. To reduce the risk of poisoning or chemical burns, keep them out of the reach of children at all times (preferably in a locked cabinet).
Do not use fabric softeners or products to eliminate static un­less recommended by the manufacturer of the fabric softener or product.
Remove laundry immediately after tumble dryer stops.
DO NOT operate the tumble dryer if it is smoking, grinding or has missing or broken parts or removed guards or panels. DO NOT tamper with the controls or bypass any safety devi­ces.
Tumble dryer will not operate with the loading door open. DO NOT bypass the door safety switch to permit the tumble dryer to operate with the door open. The tumble dryer will stop tumbling when the door is opened. Do not use the tumble dry­er if it does not stop tumbling when the door is opened or starts tumbling without pressing or turning the START mech­anism. Remove the tumble dryer from use and call for serv­ice.
Tumble dryer(s) will not operate with lint panel open. DO NOT bypass lint panel safety switch to permit the tumble dry­er to operate with the lint panel open.
Do not modify this appliance.
Always clean the lint filter daily. Keep area around the ex­haust opening and adjacent surrounding area free from the ac­cumulation of lint, dust and dirt. The interior of the tumble dryer and the exhaust duct should be cleaned periodically by qualified service personnel.
Solvent vapors from dry-cleaning machines create acids when drawn through the heater of the drying unit. These acids are corrosive to the tumble dryer as well as the laundry load being dried. Be sure make-up air is free of solvent vapors.
At the end of each working day, close off all main supplies of gas, steam and current.
Do not repair or replace any part of the tumble dryer, or at­tempt any servicing unless specifically recommended in the user-maintenance instructions or in published user-repair in­structions that the user understands and has the skills to carry out. ALWAYS disconnect and lockout the electrical power to the tumble dryer before servicing. Disconnect power by shut­ting off appropriate breaker or fuse.
Before the tumble dryer is removed from service or discarded, remove the door to the drying compartment and the door to the lint compartment.
Failure to install, maintain, and/or operate this tumble dryer according to the manufacturer’s instructions may result in conditions which can produce bodily injury and/or property damage.
NOTE: The WARNINGS and IMPORTANT SAFETY IN­STRUCTIONS appearing in this manual are not meant to cover all possible conditions and situations that may occur. Common sense, caution and care must be exer­cised when installing, maintaining, or operating the tumble dryer.
Always contact your dealer, distributor, service agent or the man­ufacturer on any problems or conditions you do not understand.
12
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458101ENR9
Specifications and Dimensions
Specifications and Dimensions
Specifications and Dimensions
Refer to machine serial plate for additional specifications.
Specifications 120 Series 170 Series 200 Series
Noise level measured during operation at operator position of 3.3 feet (1 meter) in front of machine and 5.2 feet (1.6 me­ters) from floor.
Cylinder Size: Inches [mm] 44 x 41 [1,118 x 1,041] 50.75 x 42.5 [1,289 x
Cylinder Capacity dry weight: Pounds [kg]
Standard Packag­ing Weight: Pounds [kg]
Standard Packaging Shipping Dimen­sions: Inch [mm]
Slat Crate Packag­ing Weight: Pounds [kg]
Slat Crate Shipping Dimensions: Inch [mm]
Cylinder Motor: HP [kW] 0.75 [0.560] 0.75 [0.560] 0.75 [0.560]
Gas and Electric 1,338 [607] 1,667 [756] 1,818 [825]
Steam 1,446 [656] 1,776 [806] 1,885 [855]
Gas and Electric 1,447 [656] 1,791 [812] 1,931 [876]
Steam 1,547 [702] 1,891 [858] 1,998 [906]
66 dBA 66 dBA 66 dBA
50.75 x 50 [1,289 x 1,270]
1,080]
120 [54.4] 170 [77.1] 200 [90.7]
48.5 x 71.5 x 90 [1,232 x 1,816 x 2,286]
53 x 74.5 x 90.75 [1,346 x 1,892 x 2,305]
55.63 x 73.75 x 99 [1,413 x 1,873 x 2,515]
60.13 x 76.75 x 99.75 [1,527 x 1,949 x 2,534]
55.63 x 81.25 x 99 [1,413 x 2,064 x 2,515]
60.13 x 84.25 x 101 [1,527 x 2,140 x 2,565]
Fan Motor: HP [kW] 1 [0.746] 3 [2.238] 3 [2.238]
Air Outlet Diameter: Inches [mm] 10 [254] 12 [300] 12 [300]
Maximum Static Back Pressure: W.C.I. [mbar, kPa]
Maximum Airflow: C.F.M. [L/sec.] 1,600 [755] 2,450 [1,156] 2,450 [1,156]
Gas Models
Net Weight (approximate): Pounds [kg] 1,275 [578] 1,575 [716] 1,741 [790]
Gas Connection Models through 3/10/13:
Gas Burner Rating:
Btu/hr. [Mj/hr., kW]
Part No. 70458101ENR9
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 13
0.8 [2.0, 0.2] 0.8 [2.0, 0.2] 0.8 [2.0, 0.2]
1 in. NPT 1 in. NPT
3/4 in. NPT
Models Starting 3/11/13: 1 in. NPT
270,000 [285, 79.13] 395,000 [417, 115.77] 425,000 [448, 124.56]
TMB2396N_SVG1
I
U
C
D
E
Y
Z
F
G
L
H
K
X
J
V
W
B
A
1
Specifications and Dimensions
Specifications 120 Series 170 Series 200 Series
Steam Models
Net Weight (approximate): Pounds [kg] 1,375 [624] 1,675 [761] 1,808 [820]
Steam Connection 3/4 in. NPT inlet
3/4 in. NPT outlet
Steam Coil Rating at 100 psig:
405,000 [183.1] 648,000 [294.2] 648,000 [294.2]
3/4 in. NPT inlet
1 in. NPT outlet
3/4 in. NPT inlet
1 in. NPT outlet
Btu/hr. [kg/hr.] (recommended operating pressure 80-100 psig)
Electric Models
Net Weight (approximate): Pounds [kg] 1,275 [578] Not Applicable Not Applicable
Heating Element Rating: Kilowatts
60 kW Not Applicable Not Applicable
(kW)
NOTE: All machines are shipped with extra nipple to convert to metric thread (from Standard).
120 Series Tumble Dryer Dimensions and Exhaust Outlet Locations
1. Top View of Exhaust Duct
Cabinet Dimensions
Models A B C D E F
14
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458101ENR9
Cabinet Dimensions
Specifications and Dimensions
120L/N/E 31.38 in. [797
mm]
120S 31.38 in. [797
mm]
32.5 in. [826 mm]
32.5 in. [826 mm]
48.91 in. [1,242 mm]
48.91 in. [1,242 mm]
49.91 in. [1,268 mm]
49.91 in. [1,268 mm]
67.92 in. [1,725 mm]
67.92 in. [1,725 mm]
45.38 in. [1,153 mm]
45.38 in. [1,153 mm]
Models G H I J* K* L*
120L/N/E 46.38 in. [1,178
mm]
120S 46.38 in. [1,178
mm]
85.7 in. [2,177 mm]
85.58 in. [2,174 mm]
70 in. [1,778 mm]
70 in. [1,778 mm]
41.6 in. [1,057 mm]
41.6 in. [1,057 mm]
43.2 in. [1,097 mm]
43.2 in. [1,097 mm]
61.5 in. [1,562 mm]
61.5 in. [1,562 mm]
* Fire suppression system optional - may not be on machine. Refer to Position and Level the Tumble Dryer to temporarily re-
duce the heights of these models.
Exhaust Outlet Dimensions and Locations
Models U V W X Y Z
120L/N/E 63.45 in. [1,612
mm]
120S 60.7 in. [1,542
mm]
8.44 in. [214 mm]
8.44 in. [214 mm]
10 in. [254 mm]
10 in. [254 mm]
8.18 in. [208 mm]
8.18 in. [208 mm]
6.82 in. [173 mm]
6.82 in. [173 mm]
8.18 in. [208 mm]
8.18 in. [208 mm]
Part No. 70458101ENR9
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 15
TMB2397N_SVG1
V
Y
X
W
G
F
L
H
J
K
E
D
C
I
B
A
1
Specifications and Dimensions
170 and 200 Series Tumble Dryer Dimensions and Exhaust Outlet Locations
1. Top View of Exhaust Duct
Cabinet Dimensions
Models A B C D E F
170L/N/S 33.86 in. [860
mm]
200L/N/S 32.1 in. [815
mm]
32.5 in. [ 826 mm]
35.6 in. [ 904 mm]
50.75 in. [1,289 mm]
58 in. [1,473 mm]
51.75 in. [1,314 mm]
59.25 in. [1,505 mm]
68.85 in. [1,749 mm]
76.35 in. [1,939 mm]
52.12 in. [1,324 mm]
52.12 in. [1,324 mm]
Models G H I J* K* L*
170L/N/S 53.12 in. [1,349
mm]
200L/N/S 53.12 in. [1,349
mm]
* Fire suppression system optional - may not be on machine. Refer to Position and Level the Tumble Dryer to temporarily re-
94 in. [2,388 mm]
94 in. [2,388 mm]
75.12 in. [1,908 mm]
75.12 in. [1,908 mm]
48.86 in. [1,241 mm]
48.86 in. [1,241 mm]
50.45 in. [1,281 mm]
50.45 in. [1,281 mm]
62.5 in. [1,588 mm]
62.5 in. [1,588 mm]
duce the heights of these models.
Exhaust Outlet Dimensions and Locations
Models V W X Y
170L/N/S 42.38 in. [1,076 mm] 6.75 in. [171 mm] 12 in. [305 mm] 7 in. [178 mm]
200L/N/S 42.38 in. [1076 mm] 6.75 in. [171 mm] 12 in. [305 mm] 7 in. [178 mm]
16
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458101ENR9
TMB2255N_SVG
D
B
C
A
B
D
C
A
21
TMB2382N_SVG
A
D
B
C
3
TMB2400N_SVG
B
D
D
B
C
C
A
A
21
Specifications and Dimensions
Electric and Gas Connection Locations for Gas Models Through 3/10/13
1. 120L/N
2. 170L/N
3. 200L/N
Electrical Connection Gas Connection
Models
120L/N 18.34 in. [466
170L/N 21 in. [533 mm] 81 in. [2,057 mm] 14.85 in. [377
A B C D Diameter
mm]
77.84 in. [1,977 mm]
12.5 in. [318 mm] 70.5 in. [1,791 mm]
77.4 in. [1,966
mm]
mm]
200L/N 21 in. [533 mm] 81 in. [2,057 mm] 13.7 in. [348 mm] 77.4 in. [1,966
mm]
Electric and Gas Connection Locations for Gas Models Starting 3/11/13
3/4 in. NPT
1 in. NPT
1 in. NPT
1. 120L/N
2. 170L/N and 200L/N
©
Part No. 70458101ENR9
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 17
TMB2401N_SVG
B2
B2
B1
B1
D
D
E
E
F
F
A2
A2
A1
A1
C
C
21
TMB2383N_SVG
B2
B1
D
3
E
F
A2
A1
C
Specifications and Dimensions
Electrical Connection Gas Connection
Models
120L/N 18.34 in. [466
170L/N 21 in. [533 mm] 81 in. [2,057 mm] 14.85 in. [377
200L/N 21 in. [533 mm] 81 in. [2,057 mm] 14.85 in. [377
A B C D Diameter
mm]
77.84 in. [1,977 mm]
12.5 in. [318 mm] 70.5 in. [1,791 mm]
77.4 in. [1,966
mm]
mm]
77.4 in. [1,966
mm]
mm]
1 in. NPT
1 in. NPT
1 in. NPT
Electric and Steam Connection Locations for Steam Models Through 3/10/13
1. 120S
2. 170S
3. 200S
Steam Inlet
Models
Diameter A1 A2 F
120S 3/4 in. NPT 35.875 in. [911 mm] 13.375 in. [340 mm] 82.75 in. [2,102 mm]
170S 3/4 in. NPT 37.625 in. [956 mm] 15.25 in. [387 mm] 88 in. [2,235 mm]
200S 3/4 in. NPT 37.625 in. [956 mm] 15.25 in. [387 mm] 88 in. [2,235 mm]
18
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458101ENR9
Steam Outlet
TMB2401N_SVG
B2
B2
B1
B1
D
D
E
E
F
F
A2
A2
A1
A1
C
C
21
Specifications and Dimensions
Models
Diameter B1 B2 D
120S 3/4 in. NPT 34.625 in. [879 mm] 13.125 in. [333 mm] 68.5 in. [1,740 mm]
170S 1 in. NPT 44.625 in. [1,133 mm] 8.75 in. [222 mm] 71.75 in. [1,822 mm]
200S 1 in. NPT 44.625 in. [1,133 mm] 8.75 in. [222 mm] 71.75 in. [1,822 mm]
Electrical Connection
Models
C E
120S 18.34 in. [466 mm] 77.84 in. [1,977 mm]
170S 21 in. [533 mm] 81 in. [2,057 mm]
200S 21 in. [533 mm] 81 in. [2,057 mm]
Electric and Steam Connection Locations for Steam Models Starting 3/11/13
1. 120S
2. 170S and 200S
Steam Inlet
Models
120S 3/4 in. NPT 35.875 in. [911 mm] 13.375 in. [340 mm] 82.75 in. [2,102 mm]
Diameter A1 A2 F
170S 3/4 in. NPT 37.625 in. [956 mm] 15.5 in. [394 mm] 87.625 in. [2,226 mm]
200S 3/4 in. NPT 37.625 in. [956 mm] 15.5 in. [394 mm] 87.625 in. [2,226 mm]
Part No. 70458101ENR9
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 19
TMB2336N_SVG
A
B
Specifications and Dimensions
Steam Outlet
Models
Diameter B1 B2 D
120S 3/4 in. NPT 34.625 in. [879 mm] 13.125 in. [333 mm] 68.5 in. [1,740 mm]
170S 1 in. NPT 44.125 in. [1,133 mm] 9 in. [229 mm] 72.125 in. [1,832 mm]
200S 1 in. NPT 44.125 in. [1,133 mm] 9 in. [229 mm] 72.125 in. [1,832 mm]
Electrical Connection
Models
C E
120S 18.34 in. [466 mm] 77.84 in. [1,977 mm]
170S 21 in. [533 mm] 81 in. [2,057 mm]
200S 21 in. [533 mm] 81 in. [2,057 mm]
Electric Connection Location for Electric Models
20
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458101ENR9
Specifications and Dimensions
Models A B
120E 35.81 in. [910 mm] 85.64 in. [2,175 mm]
Part No. 70458101ENR9
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 21
Installation
Installation
Pre-Installation Inspection
Upon delivery, visually inspect the crate, carton and parts for any visible shipping damage. If the crate, carton, or cover is damaged or signs of possible damage are evident, have the carrier note the condition on the shipping papers before the shipping receipt is signed, or advise the carrier of the condition as soon as it is dis­covered.
Remove the crate and protective cover as soon as possible and check the items listed on the packing list. Advise the carrier of any damaged or missing articles as soon as possible. A written claim should be filed with the carrier immediately if articles are damaged or missing.
IMPORTANT: Remove the shipping tape from the two back draft dampers located in the exhaust outlet.
IMPORTANT: Warranty is void unless tumble dryer is installed according to instructions in this manual. In­stallation should comply with minimum specifications and requirements detailed in this manual and applica­ble local gas fitting regulations, municipal building co­des, water supply regulations, electrical wiring regula­tions, and any other relevant statutory regulations. Due to varied requirements, applicable local codes should be thoroughly understood and all pre-installation work arranged for accordingly.
Materials Required (Obtain Locally)
Materials Required (Obtain Locally)
cm] working pressure for connecting steam coils. Refer to Figure 21 and Figure 22 for sizing and connection configurations.
Two steam traps for steam coil outlets to condensate return line.
Optional – Two vacuum breakers for con­densate return lines.
IMPORTANT: 3 Phase Only – Each tumble dryer must be connected to its own individual branch circuit breaker, not fuses, to avoid the possibility of “single phasing” and causing premature failure of the mo­tor(s).
Location Requirements
The tumble dryer must be installed on a level floor. Floor cover­ing materials such as carpeting or tile should be removed.
To assure compliance, consult local building code requirements. The tumble dryer must not be installed or stored in area where it will be exposed to water and/or weather.
IMPORTANT: DO NOT block the airflow at the rear of the tumble dryer with laundry or other articles. Doing so would prevent adequate air supply to the combus­tion chamber of the tumble dryer.
All Models One Single Pole fused disconnect switch or
circuit breaker on 1 Phase models.
Circuit breaker on 3 Phase models.
Gas Models One gas shut-off valve for gas service line
to each tumble dryer.
Steam Models One steam shut-off valve for steam service
line to be connected upstream of solenoid steam valve.
Two steam shut-off valves for each conden­sate return line.
Flexible steam hoses with a 125 psig [pounds per square inch gauge] [8.79 kg/sq.
A typical tumble dryer enclosure is shown in Figure 2 .
IMPORTANT: Install tumble dryers with sufficient clear­ance for servicing and operation, refer to Figure 2 .
WARNING
To reduce the risk of severe injury, clearance of tum­bler cabinet from combustible construction must conform to the minimum clearances, and/or local co­des and ordinances.
W770
Part No. 70458101ENR9
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 22
TMB2020N_SVG
4
3
1
5
6
7
8
2
Installation
NOTE: Shaded areas indicate adjacent structure.
1. 0.5 in. [13 mm] recommended between machines for removal or installation
2. Allow 2-4 in. [51-102 mm] opening at top of machine to aid in removal or installation. A removable trim piece may be used to
conceal the opening; zero clearance allowed for trim.
3. 4 in. [102 mm] maximum header thickness
4. Minimum clearance permitted for remainder:
120 Gas/Electric 4 in. [101.6 mm]
120 Steam 6 in. [152.4 mm]
170/200 Gas 4 in. [101.6 mm]
170/200 Steam 8 in. [203.2 mm]
5. Guard
6. Provision for make-up air
7. 24 in. [610 mm] minimum, 36 in. [914 mm] recommended for maintenance purposes
8. 0.25 in. [6 mm] recommended for removal or installation purposes, zero clearance allowed
Figure 2
Position and Level the Tumble Dryer
The tumble dryer may be moved with or without the skid. To re-
Fire Suppression System (Optional
Equipment)
move the skid, unscrew the four shipping bolts, and discard them.
To fit a 170 and 200 series tumble dryer (with shipping skid) through a 8 foot [2.43 meters] high door, you must remove the front access panel. The upper 3 inches [76 mm] of the stove must also be removed on 170 series gas tumble dryers. Removing the entire gas or steam heater assembly and the shipping skid, will re­duce the height of the 120 series tumble dryer to 70 inches [1,778 mm], and the 170 and 200 series tumble dryer to 75 inches [1,905 mm].
Level the tumble dryer to within 0.125 inch [3 mm] from front-
Electrical shock can result in death or serious injury. If the water dispensing system is activated, do not attempt to operate the tumble dryer. If the water dis­pensing system is activated, have the tumble dryer inspected by a qualified agency before operating the tumble dryer.
to-rear (level on cylinder rib), and side-to-side (level on top pan­el). Shim under corners to level and stabilize unit. Tumble dryer must not rock.
Check Local Codes and Permits
WARNING
W879
Part No. 70458101ENR9
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 23
TMB2012N_SVG
2
1
3
3
170/200
120
Installation
Call your local water company or the proper municipal authority for information regarding local codes.
IMPORTANT: It is your responsibility to have ALL plumbing connections made by a qualified professio­nal to assure that the plumbing is adequate and con­forms to local, state, and federal regulations or codes.
IMPORTANT: It is the installation or owner’s responsi­bility to see that the necessary or required water, water pressure, pipe size, or connections are provided. Man­ufacturer assumes no responsibility if the fire suppres­sion system is not connected, installed, or maintained properly.
Water Requirements
IMPORTANT: Water must be supplied to the fire sup­pression system, or the fire suppression system will not operate as intended.
Connection point to the electric water solenoid valve is a 3/4 inch [19 mm] hose. The fire suppression system equipped tumble dry­er must be supplied with a minimum water pipe size of 1/2 inch [12.7 mm] and be provided with a minimum of 20 psi [138 kPa] and a maximum of 120 psi [827 kPa] of pressure at all times. Flowrate must be no less than, but approximately 15 gallons [57 liters] per minute.
NOTE: Water pressure under 20 psi [138 kPa] will cause low flow and water leakage at water solenoid valve.
IMPORTANT: Temperature of the water supply must be kept between 40°F and 120°F [4.4°C and 48.9°C] . If wa­ter in the supply line or water solenoid valve freezes, the fire suppression system will not operate.
IMPORTANT: If temperature sensors inside the tumble dryer register a temperature below 40F° [4.4°C] , the fire suppression system control will lock out. This fea­ture protects against operation of the tumble dryer with a possible frozen water supply. Only when the temper­ature sensors register a temperature above 40F° [4.4°C] will the machine reset for operation.
IMPORTANT: Flexible supply line/coupling must be used. Solenoid valve failure due to hard plumbing con­nections will void the warranty. It is recommended that a filter or strainer be installed in the water supply line.
Water Connections
Connect machine to a backflow preventer (vacuum breaker) be­fore connecting to the public water main in all countries where local regulations require specific water approval certificates.
Two hoses and a Y-valve are provided with the tumble dryer to allow for connection of water supply to tumble dryer. The water connections are made to the bushings of the water solenoid valve, located on the rear of the tumble dryer. The Y-valve provides a single female hose connection (Standard US 3/4-11 1/2 NH thread). Refer to Figure 3 and Figure 4 .
If the rear of the tumble dryer or the water supply is located in an area where it will be exposed to cold/freezing temperatures, pro­visions must be made to protect these water lines from freezing.
1. Fire Suppression System Control Box
2. Water Solenoid Valve
3. Opening for Auxiliary Alarm Cable
Figure 3
24
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458101ENR9