Page 1
Drying Tumblers
Refer to Page 3 for Model Identification
H
I
G
H
T
E
M
P
S
T
AR
T
L
O
W
T
E
M
P
M
E
D
T
E
M
P
N
O
H
E
A
T
C
25
1
S
E
L
2
E
C
T
T
I
E
N
M
S
E
P
R
C
O
I
N
1
S
E
L
2
E
C
T
T
I
E
N
M
S
E
P
3
R
T
C
O
P
H
I
U
N
I
S
G
H
H
S
T
T
E
A
M
R
P
T
ST
AR
T
L
O
W
T
E
M
P
M
E
D
T
E
M
3
T
P
U
S
H
S
T
A
R
T
P
N
O
H
E
A
T
C
25
Troubleshooting
T478C
T478C
Keep These Instructions for Future Reference.
(If this machine changes ownership, this manual must accompany machine.)
www.comlaundry.com
T477C
T477C
Part No. 70172201
November 2001
Page 2
Table of
Contents
Introduction ......................................................................................... 3
Model Identification ............................................................................. 3
Theory of Operation of Instant Electronic Ignition .............................. 3
Safety Information.............................................................................. 5
Cannot Perform Infrared (IR) Communication.............................. 7
Coins Ignored When Entered ............................................................ 9
Control Display ................................................................................... 11
Door Open Light “On” ......................................................................... 11
No Visible Display – OPL Microprocessor Models............................. 12
No Visible Display – Power On ........................................................... 13
Will Not Start ...................................................................................... 15
Electric.................................................................................................. 15
Manual Timer................................................................................... 15
Rotary Coin Drop............................................................................. 16
Gas ........................................................................................................ 18
Manual Timer................................................................................... 18
Rotary Coin Drop............................................................................. 19
Steam .................................................................................................... 21
Manual Timer................................................................................... 21
Rotary Coin Drop............................................................................. 22
Will Not Start/Continue Running ..................................................... 25
EDC Control ......................................................................................... 25
OPL Microprocessor Control ............................................................... 28
Will Not Run ....................................................................................... 31
Electric.................................................................................................. 31
Manual Timer................................................................................... 31
Rotary Coin Drop............................................................................. 34
Gas ........................................................................................................ 37
Manual Timer................................................................................... 37
Rotary Coin Drop............................................................................. 39
Steam .................................................................................................... 41
Manual Timer................................................................................... 41
Rotary Coin Drop............................................................................. 43
Will Not Heat ....................................................................................... 45
Electric.................................................................................................. 45
Manual Timer................................................................................... 45
Rotary Coin Drop............................................................................. 47
Rotary Coin Drop (with and without time delay board) ................. 49
Electric/Gas........................................................................................... 51
OPL Microprocessor........................................................................ 51
Gas ........................................................................................................ 54
EDC Models..................................................................................... 54
Manual Timer................................................................................... 56
Rotary Coin Drop............................................................................. 58
© Copyright 2001, Alliance Laundry Systems LLC
All rights reserved. No part of the contents of this book may be reproduced or transmitted in any form or by any
means without the expressed written consent of the publisher.
70172201
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
1
Page 3
Steam .................................................................................................... 60
EDC Models..................................................................................... 60
Manual Timer................................................................................... 62
OPL Microprocessor........................................................................ 64
Rotary Coin Drop............................................................................. 67
2
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70172201
Page 4
Introduction
Model Identification
Information in this manual is applicable to these tumbler models:
Gas Steam/Thermal Oil Electric
25 Pound
(220 Liter)
30 Pound
(270 Liter)
30 Pound
Stacked
(300 Liter)
35 Pound
(350 Liter)
DC0220SFG
DC0220SRG
DT0220SFG
DT0220SRG
JC0220SFG
JC0220SRG
DC0270SFG
DC0270SRG
DT0270SFG
DT0270SRG
JC0270SFG
JC0270SRG
DC0300DFG
DC0300DRG
DT0300DFG
DT0300DRG
JC0300DFG
JC0300DRG
JT0300DFG
AT0350SRG
DC0350SFG
DC0350SRG
DT0350SFG
DT0350SRG
JC0350SFG
JC0350SRG
JT0220SFG
JT0220SRG
SC0220SFG
SC0220SRG
ST0220SFG
ST0220SRG
JT0270SFG
JT0270SRG
SC0270SFG
SC0270SRG
ST0270SFG
ST0270SRG
JT0300DRG
NT0300DRG
SC0300DFG
SC0300DRG
ST0300DFG
ST0300DRG
JT0350SFG
JT0350SRG
SC0350SFG
SC0350SRG
ST0350SFG
ST0350SRG
DC0220SSL
DT0220SSH
DT0220SSL
JC0220SSL
JT0220SSH
DC0270SSL
DT0270SSH
DT0270SSL
JC0270SSL
JT0270SSH
DC0300DSL
DT0300DSH
DT0300DSL
JC0300DSL
JT0300DSH
AT0350SSL
DC0350SSL
DT0350SSH
DT0350SSL
JC0350SSL
JT0220SSL
SC0220SSL
ST0220SSH
ST0220SSL
JT0270SSL
SC0270SSL
ST0270SSH
ST0270SSL
JT0300DSL
SC0300DSL
ST0300DSH
ST0300DSL
JT0350SSH
JT0350SSL
SC0350SSL
ST0350SSH
ST3050SSL
DC0220SEL
DT0220SEL
JC0220SEL
DC0270SEL
DT0270SEL
JC0270SEL
DC0300DEL
DT0300DEL
JC0300DEL
DC0350SEL
DT0350SEL
JC0350SEL
JT0220SEL
SC0220SEL
ST0220SEL
JT0270SEL
SC0270SEL
ST0270SEL
JT0300DEL
SC0300DEL
ST0300DEL
JT0350SEL
SC0350SEL
ST0350SEL
Theory of Operation of Instant
Electronic Ignition
IMPORTANT: The Non-CE Marked Instant
Electronic Ignition system will attempt to light the
gas by sparking for approximately 15 seconds. If
gas ignition does not take place within
approximately 15 seconds, the Instant Electronic
Ignition control will go into safety lockout and the
valve will no longer open until Instant Electronic
Ignition control is reset. To reset Instant Electronic
Ignition control, remove power from control by
opening and closing the tumbler door. If condition
persists, check that the gas shut-off valve is in “on”
position and that the gas service is properly
connected.
70172201
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
If condition persists:
1. Check resistance of high tension lead
(approximately 1000 ohms/inch), and replace if
not within resistance range.
2. Check voltage present at valve.
3. Check that machine is properly grounded.
4. Check the gap between igniter and burner tube
(gap should be 1/4-3/8 inch).
5. Check that burner ports are not blocked or
plugged under the igniter.
3
Page 5
Safety Information
DANGER indicates the presence of a
hazard that will cause severe personal
injury, death, or substantial property
damage if the danger is ignored.
DANGER
WARNING indicates the presence of a
hazard that can cause severe personal
injury, death, or substantial property
damage if the warning is ignored.
WARNING
CAUTION indicates the presence of a
hazard that will or can cause minor
personal injury or property damage if the
caution is ignored.
CAUTION
Precautionary statements ( “DANGER, ”
“WARNING,” and “CAUTION”), followed by
specific instructions, are found in this manual and on
machine decals. These precautions are intended for the
personal safety of the operator, user, servicer, and
those maintaining the machine.
IMPORTANT: The word “IMPORTANT” is used
to inform the reader of specific procedures where
minor machine damage will occur if the procedure
is not followed.
NOTE: The word “NOTE” is used to communicate
installation, operation, maintenance or servicing
information that is important but not hazard
related.
WARNING
Failure to install, maintain, and/or operate
this machine according to manufacturer’s
instructions may result in conditions which
can produce serious injury, death and/or
property damage.
W051
NOTE: The WARNINGS and IMPORTANT
instructions appearing in this manual are not
meant to cover all possible conditions and
situations that may occur. It must be understood
that common sense, caution and carefulness are
factors which CANNOT be built into this tumbler.
These factors MUST BE supplied by the person(s)
installing, maintaining or operating the tumbler.
Additional precautionary statements (“IMPORTANT”
and “ NOTE” ) are followed by specific instructions.
Always contact your dealer, distributor, service agent
or the manufacturer on any problems or conditions you
do not understand.
70172201
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
5
Page 6
Cannot Perform Infrared (IR)
Communication
Single and stacked.
Gas and electric heat.
Attempt to
communicate with
the electronic
control from the
micro wand.
Is there a response of
any kind from the
electronic control?
YES
Single and three phase
supply.
NO
Aim micro wand
closer and try again.
Does the control
respond?
YES
NO
Check the following:
- low battery on micro wand
- is the IR window covered or
blocked on the control.
- if needed replace the EDC
- is the IR cap properly attached
control
to the micro wand.
Does the electronic
control display "E:OF"
or "-C-"?
"E:OF"
Check the following:
- IR communication disabled by
manual programming.
- Is the IR window on the control
covered or blocked.
- if needed, change EDC board.
"-C-"
Communication
sequence checks
out.
T027D
T027D
70172201
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
7
Page 7
Coins Ignored When Entered
Single and stacked
units. Gas and electric
heat. Single and three
phase voltage.
Start coin drop
diagnostic tests.
Does the display on the
EDC control increment
properly?
NO
Is connector H2 firmly
seated in its
receptacle?
YES
Is the 3 pin connector
between coin drop and
control connected
correctly?
YES
Are wires exiting coin
drop optical sensor
cracked or broken?
YES
NO
NO
YES
Exit diagnostic
testing and reset
control. (Prompting
for vend price)
Reconnect and run
diagnostic test
again.
Reconnect and run
diagnostic test
again.
Replace coin drop.
70172201
NO
Replace coin drop.
If problem still
exists then replace
the EDC control.
T026D
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
T026D
9
Page 8
Door Open Light “On”
Control Display
Is there voltage at
"H4-6 on the EDC
control?
NO
Is there power supplied
to the unit?
YES
Is there voltage to input
of primary fuses?
YES
Is there voltage to
output side of the
primary fuses?
YES
Single and stacked
units. Gas and electric
heat. Single and three
phase supply.
YES
NO
NO
NO
Reference voltage
checks to transformer
Replace EDC
Control.
Plug unit in and
run it.
Correct wiring
between primary
fuses and power
supply.
Replace primary
fuse(s).
neutral.
Is there voltage at
the input of the
secondary fuse?
YES
Is there voltage to
output side of
secondary fuse?
YES
Is there voltage to
N.O. of door
switch?
YES
With door closed is
there voltage to
COM of door
switch?
YES
NO
NO
NO
NO
Correct wiring
between secondary
fuse and
transformer.
Replace secondary
fuse.
Correct wiring
between N.O. and
output of secondary
fuse.
Check for proper
function of door
switch replace if
necessary.
70172201
Is there voltage across
terminals "1" & "2" of
transformer primary?
YES
Is there voltage across
terminals "2" & "3" of
transformer
secondary?
YES
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
NO
NO
Correct wiring
between primary
fuses and
transformer.
Replace
transformer.
Is there voltage to
N.O. of lint drawer
switch?
YES
Is there voltage to
COM of lint drawer
switch with lint
panel closed?
YES
Correct wiring
between "H4-6" of
EDC control and
COM of lint drawer
switch.
NO
NO
Correct wiring
between N.O. on lint
drawer and COM on
door switch.
Check for proper
operation replace if
necessary.
T028D
T028D
11
Page 9
Control Display
No Visible Display – OPL Microprocessor Models
Gas, steam
and electric heat.
Single and three
phase supply.
Is there voltage
supplied to the unit?
YES
Note: Reference voltage to
Is there voltage to the
input side of the
primary fuse(s)?
YES
Is there voltage to the
output side of the
primary fuse(s)?
YES
Is there voltage
to primary side of
the transformer
terminal "1"?
NO
supply neutral.
NO
NO
NO
Connect supply
voltage and run unit.
Correct wiring
between primary
fuse and supply.
Replace primary
fuse.
Correct wiring
between transformer
and primary fuse.
Is there voltage across
fuse on OPL Micro?
YES
Replace fuse.
NO
Replace OPL Micro.
YES
Is there voltage across
"1" & "4" of transformer
secondary?
YES
Is there voltage across
terminals "H3-3" &
"H3-4" on OPL Micro?
YES
NO
NO
Replace transformer
Correct wiring
between OPL Micro
and transformer
secondary.
T007D
T007D
12
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70172201
Page 10
No Visible Display – Power On
Single and stacked
units. Gas and electric
heat. Single and three
phase supply.
Is there voltage across
"H4-2 & H4-5" on the
EDC control?
Replace EDC
Control.
Is there voltage at
the input of the
secondary fuse?
NO YES
Control Display
Correct wiring
between secondary
fuse and
transformer.
NO
Is there power supplied
to the unit?
YES
Is there voltage to input
of primary fuses?
YES
Is there voltage to
output side of the
primary fuses?
YES
Is there voltage across
terminals "1" & "2" of
transformer primary?
NO
NO
NO
NO
Plug unit in and run
it.
Correct wiring
between primary
fuses and power
supply.
Replace primary
fuse(s).
Correct wiring
between primary
fuse and
transformer.
YES
Is there voltage to
output side of
secondary fuse?
YES
Correct wiring
between "H4-2" and
secondary fuse.
NO
Replace secondary
fuse.
70172201
YES
Is there voltage across
terminals "2" & "3" of
transformer
secondary?
YES
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
NO
Replace
transformer.
T025D
T025D
13
Page 11
Electric
Manual Timer
Manual Timer, with and without Time Delay Board, Single and
Will Not Start
Stacked units, Single and 3 Phase power supply.
Is there power supply
voltage coming to the
tumbler?
YES
Is there
voltage at the primary side
of the transformer at
terminals 1 and 2?
YES
Is
there voltage at the
secondary side of the
transformer at terminal
2 and 3?
YES
Is there voltage to the
output side of the
secondary fuse?
NOTE: White wires are
YES
transformer "neutral"
Is there voltage to the
"N.O." terminal of the
door switch?
NO
NO
NO
NO
YES
Connect power
and run the cycle.
Change the primary
fuse to the
transformer.
Replace the
transformer.
Change the
secondary fuse.
With door closed Is
there voltage at "COM"
of the door switch?
Still no voltage
For stacked units.
Correct the wiring
NO
secondary fuse and
the transformer.
Correct wiring
between power
supply and
transformer.
Correct wiring
between upper and
lower pocket.
between the
YES
Is there voltage to the
"COM" of the lint panel
switch?
YES
70172201
NO
Correct the wiring
between the door
switch and the
secondary fuse.
With lint panel
closed is there votlage to
"N.O." terminal of the
liint panel switch?
NO
YES
Replace lint
panel switch.
NO
Check for proper
operation,
replace the door
switch if
necessary.
Refer to NO
MOTOR RUN
(run circuit.)
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
NO
Correct wiring
between lint panel
switch and door
switch.
T050D
T050D
15
Page 12
Will Not Start
Electric
Rotary Coin Drop (Sheet 1 of 2)
Coin Drop with and without Time Delay Boards.
Single and Stacked units. Single and 3 phase
power supply.
Is there power supply
voltage coming to the
unit?
YES
Is there voltage at the
primary side of the
transformer at terminals
"1" & "2"?
YES
Is there voltage at the
secondary side of the
transformer at terminal
"2" and "3"?
YES
Is there voltage to the
output side of the
secondary fuse?
YES
Note: Reference voltage
to transformer neutral.
(White wire)
Is there voltage to
"N.C." terminal of
switch "A" on rotary
coin drop?
YES
Is the unit equipped
with time delay
boards?
NO
Note: The following
checks are made with
the vend price satisfied.
Is there voltage on the
"COM" terminal of switch
"A"?
NO
NO
NO
NO
NO
YES
NO
Connect power to
the unit and run
cycle.
Is the primary
fuse good?
YES
Correct wiring
between transformer
and power supply.
Replace the
transformer.
Is the
secondary
fuse good?
YES
Correct wiring
between secondary
of transformer and
fuse.
Correct wiring
between rotary
coin drop and
secondary fuse.
Continued on next
page at step 1.
Replace switch "A".
NO
NO
Replace
fuse and
run
machine.
Replace
fuse and
run
machine.
Is there voltage across
coinmeter timer motor?
YES
Does the coinmeter
timer motor
advance?
YES
Is there voltage at
N.O. terminal of the
door switch?
YES
With the door
closed is there
voltage across the
door switch?
NO
Is there voltage to
the N.O. terminal of
the lint panel
switch?
YES
With the lint
panel closed is there
voltage across the
lint panel switch?
NO
Continued on next
page at step 2.
Step 3 continuation.
NO
NO
NO
YES
NO
YES
Correct wiring
between
coinmeter timer
motor and COM
on switch "A".
Replace coinmeter
timer motor.
Correct wiring
between N.O on
door switch and
COM on switch"A".
Check door switch
for proper operation,
replace if necessary.
Correct wiring
between N.O. on the
lint panel switch and
COM of door switch.
Check lint panel
switch for proper
operation and
replace if necessary.
16
YES
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
T075D
T075D
70172201
Page 13
Electric
Rotary Coin Drop (Sheet 2 of 2)
Will Not Start
STEP 1
Is there voltage to
"H1-2" on TMR1
board?
YES
Note: Following tests
are conducted with
vend price satisfied.
With vend price
satisfied is there
voltage across "N.C." &
COM of switch "A"?
NO
Is there voltage across
the timer motor?
YES
Does Coinmeter Timer
Motor advance?
YES
NO
YES
NO
NO
Correct wiring
between
"H1-2" and
output of
secondary
fuse.
Replace Switch "A"
Correct wiring
between timer
motor and COM on
switch "A"
Replace Timer
Motor.
3 phase
STEP 2
Is there voltage at
"2A" of the start
switch?
YES
Does the unit have
single phase or three
phase power supply?
Single phase
Is there voltage at
terminal "7" of the
motor relay?
YES
NO
between "2A" of start
NO
Refer to NO
MOTOR RUN
(run circuit).
Correct wiring
switch and COM of
lint panel switch.
Correct wiring
between "7" of
motor relay and COM
of lint panel switch.
Is there voltage across
"H1-6" & "H1-8" of
TMR1?
YES
Is there voltage across
"H1-2" & "H1-3" of
TMR1"?
NO
Is there voltage to N.O.
of door switch?
YES
Continue at step 3
on previous page.
NO
YES
NO
Correct wiring
between "H1-6" and
COM on switch "A"
Replace TMR1.
Correct wiring
between N.O. of
door switch and
"H1-3" of TMR1.
Is there voltage at
terminal "14" of the
motor control relay?
YES
Refer to NO
MOTOR RUN (Run
Circuit).
NO
Correct wiring to
terminal "14" of
motor control
relay.
T076D
T076D
70172201
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
17
Page 14
Will Not Start
Gas
Manual Timer
No motor run (start circuit) Manual Tumblers. Single and stacked units
with and without time delay. GAS UNITS
Is there power supply
voltage coming to the
tumbler?
YES
Is there voltage at the
primary side of the
transformer at
terminals 1 and 2?
YES
Is there voltage at the
secondary side of the
transformer at terminal
2 and 3?
YES
Is there voltage to the
output side of the
secondary fuse?
NO
NO
NO
NO
Connect power
and run the cycle.
Change the primary
fuse to the
transformer.
Replace the
transformer.
Change the
secondary fuse.
Still no voltage
For stacked units.
Correct the wiring
NO
secondary fuse and
the transformer
Correct wiring
between power
supply and
transformer.
Correct wiring
between upper and
lower pocket.
between the
.
NOTE: White wires are
YES
Is there voltage to the
input side of the door
switch?
NO
Correct the wiring
between the door
switch and the
secondary fuse.
Is there voltage to the
output side of the lint
panel switch?
NO
transformer "neutral"
YES
YES
Is there voltage to the
output side of the door
switch?
Replace the
door switch.
Replace lint
panel switch.
NO
YES
Refer to NO
MOTOR RUN
(run circuit).
Is there voltage to the
input side of the lint
panel switch?
NO
Correct wiring
between lint panel
switch and door
switch.
YES
T041D
T041D
18
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70172201
Page 15
Gas
Rotary Coin Drop (Sheet 1 of 2)
Single &
Stacked Tumblers
with and without time delay
Gas units.
Will Not Start
Is there power supply
voltage coming to the
unit?
YES
Is there voltage
at the primary side of the
transformer at terminals
"1" & "2"?
YES
Is there voltage at the
secondary side of the
transformer at terminal
"2" and "3"?
YES
Is there voltage to the
output side of the
secondary fuse?
YES
Note: Reference voltage to
transformer neutral.
Is there voltage to
"N.C." terminal of
switch "A" on rotary
coin drop?
YES
NO
NO
NO
NO
(White wire)
NO
Connect power to
the unit and run
cycle.
Is the primary
fuse good?
YES
Correct wiring
between transformer
and power supply.
Replace the
transformer.
Is the
secondary
fuse good?
YES
Correct wiring
between secondary
of transformer and
fuse.
Correct wiring
between rotary coin
drop and secondary
fuse.
NO
NO
Replace
fuse and
run
machine.
Replace
fuse and
run
machine.
Is there voltage across
coinmeter timer motor?
YES
Does the coinmeter
timer motor
advance?
YES
Is there voltage at
N.O. terminal of the
door switch?
YES
With the door
closed is there
voltage across the
door switch?
NO
Is there voltage to
the N.O. terminal of
the lint panel
switch?
YES
NO
NO
NO
YES
NO
Correct wiring
between
coinmeter timer
motor and COM
on switch "A".
Replace coinmeter
timer motor.
Correct wiring
between N.O on
door switch and
COM on switch"A".
Check door switch
for proper operation,
replace if necessary.
Correct wiring
between N.O. on the
lint panel switch and
COM of door switch.
70172201
Is the unit equipped
with time delay
boards?
NO
Note: The following
checks are made with
the vend price satisfied.
Is there voltage on the
COM terminal of switch
"A"?
YES
With the lint
YES
NO
Continued on next
page at step 1.
Replace switch "A".
panel closed is there
voltage across the lint
panel switch?
NO
Continued on next
page at step 2.
Step 3 continuation.
YES
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Check lint panel
switch for proper
operation and
replace if necessary.
T086D
T086D
19
Page 16
Will Not Start
Gas
Rotary Coin Drop (Sheet 2 of 2)
STEP 1
Is there voltage to
"H1-2" on TMR1
board?
YES
Note: Following tests
are conducted with
vend price satisfied.
With vend price
satisfied is there
voltage across "N.C." &
COM of switch "A"?
NO
Is there voltage across
the timer motor?
YES
Does Coinmeter Timer
Motor advance?
YES
NO
YES
NO
NO
Correct wiring
between
"H1-2" and
output of
secondary
fuse.
Replace Switch "A"
Correct wiring
between timer motor
and COM on switch
"A"
Replace Timer
Motor.
STEP 2
Is there voltage at
2A of the start
switch?
YES
Is there voltage at
terminal 7 of the
motor relay?
YES
NO
NO
Refer to NO
MOTOR RUN
(run circuit).
Correct wiring
between 2A of start
switch and COM of
lint panel switch.
Correct wiring
between 7 of motor
relay and COM of
lint panel switch.
Is there voltage across
"H1-6" & "H1-8" of
TMR1?
YES
Is there voltage across
"H1-2" & "H1-3" of
TMR1?
NO
Is there voltage to N.O.
of door switch?
YES
Continue at step 3
on previous page.
NO
YES
NO
Correct wiring
between "H1-6" and
COM on switch "A"
Replace TMR1.
Correct wiring
between N.O. of
door switch and
"H1-3" of TMR1.
T087D
T087D
20
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70172201
Page 17
Steam
Manual Timer
Single and stacked units with and without
time delay boards. Steam Heat.
Will Not Start
Is there power supply
voltage coming to the
tumbler?
YES
Is there voltage at the
primary side of the
transformer at
terminals 1 and 2?
YES
Is there voltage at the
secondary side of the
transformer at terminal
2 and 3?
YES
Is there voltage to the
output side of the
secondary fuse?
NOTE: White wires are
YES
transformer "neutral"
NO
NO
NO
NO
Connect power
and run the cycle.
Change the primary
fuse to the
transformer
Replace the
transformer.
Change the
secondary fuse.
Still no voltage
For stacked units.
Correct the wiring
NO
secondary fuse and
the transformer.
Correct wiring
between power
supply and
transformer.
Correct wiring
between upper and
lower pocket.
between the
70172201
Is there voltage to the
N.O. terminal of the
door switch?
NO
Correct the wiring
between the door
switch and the
secondary fuse
Is there voltage to the
N.O. terminal of the
lint panel switch?
NO
YES
YES
Is there voltage to the
COM terminal of the
door switch?
Replace the
door switch.
Replace lint
panel switch.
NO
YES
Refer to NO
MOTOR RUN
(run circuit) .
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Is there voltage to the
COM terminal of the
lint panel switch?
NO
Correct wiring
between lint panel
switch and door
switch.
YES
T016D
T016D
21
Page 18
Will Not Start
Steam
Rotary Coin Drop (Sheet 1 of 2)
Single &
Stacked Tumblers
with and without time delay
Steam units.
Is there power supply
to the unit?
YES
Is there voltage
at the primary side of the
transformer at terminals
"1" & "2"?
YES
Is there voltage
at the secondary side of the
transformer at terminal
"2" and "3"?
YES
Is there voltage to the
output side of the
secondary fuse?
YES
Note: Reference voltage to
transformer neutral.
Is there voltage to
"N.C." terminal of
switch "A" on rotary
coin drop?
YES
NO
NO
NO
NO
(White wire)
NO
Connect power to
the unit and run
cycle.
Is the primary
fuse good?
YES
Correct wiring
between transformer
and power supply.
Replace the
transformer.
Is the
secondary
fuse good?
YES
Correct wiring
between secondary
of transformer and
fuse.
Correct wiring
between rotary coin
drop and secondary
fuse.
NO
NO
Replace
fuse and
run
machine.
Replace
fuse and
run
machine.
Is there voltage across
coinmeter timer motor?
YES
Does the coinmeter
timer motor
advance?
YES
Is there voltage at
N.O. terminal of the
door switch?
YES
With the door
closed is there
voltage across the
door switch?
NO
Is there voltage to
the N.O. terminal of
the lint panel
switch?
YES
NO
NO
NO
YES
NO
Correct wiring
between
coinmeter timer
motor and COM
on switch "A".
Replace coinmeter
timer motor.
Correct wiring
between N.O on
door switch and
COM on switch"A".
Check door switch
for proper operation,
replace if necessary.
Correct wiring
between N.O. on the
lint panel switch and
COM of door switch.
22
Is the unit equipped
with time delay
boards?
NO
Note: The following
checks are made with
the vend price satisfied.
Is there voltage on the
COM terminal of switch
"A"?
YES
With the lint
YES
NO
Continued on next
page column 1.
Replace switch "A".
panel closed is there
voltage across the
lint panel switch?
NO
Continued on next
page column 2.
Step 3 continuation.
YES
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Check lint panel
switch for proper
operation and
replace if necessary.
T062D
T062D
70172201
Page 19
Steam
Rotary Coin Drop (Sheet 2 of 2)
Will Not Start
COLUMN 1
Is there voltage to
"H1-2" on TMR1
board?
YES
Note: Following tests
vend price satisfied.
With vend price
satisfied is there
voltage across "N.C." &
COM of switch "A"?
NO
Is there voltage across
the timer motor?
YES
Does Coinmeter Timer
Motor advance?
YES
NO
are conducted with
YES
NO
NO
Correct wiring
between
"H1-2" and
output of
secondary
fuse.
Replace Switch "A"
Correct wiring
between timer motor
and COM on switch
"A"
Replace Timer
Motor.
COLUMN 2
Is there voltage at
"2A" of the start
switch?
YES
Is there voltage at
terminal "7" of the
motor relay?
YES
NO
NO
Refer to NO
MOTOR RUN
(run circuit).
Correct wiring
between "2A" of
start switch and COM
of lint panel switch.
Correct wiring
between "7" of
motor relay and COM
of lint panel switch.
Is there voltage across
"H1-6" & "H1-8" of
TMR1?
YES
Is there voltage across
"H1-2" & "H1-3" of
TMR1"?
NO
Is there voltage to N.O.
of door switch?
YES
Continue at step 3
on previous page.
NO
YES
NO
Correct wiring
between "H1-6" and
COM on switch "A"
Replace TMR1.
Correct wiring
between N.O. of
door switch and
"H1-3" of TMR1.
T063D
T063D
70172201
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
23
Page 20
Will Not Start/Continue Running
EDC Control (Sheet 1 of 3)
Note: test conducted with vend
price satisfied and start button
pressed.
Is there voltage at
"H4-4" on the EDC
control to transformer
neutral?
YES
Single and stacked
units. Gas, electric and
steam heat. Single and
three phase supply.
Continued on next
page.
Is there voltage at the
input of the secondary
fuse?
NO
Correct wiring
between secondary
fuse and
transformer.
NO
Is there power supplied
to the unit?
YES
Is there voltage to input
of primary fuse(s)?
YES
Is there voltage to
output side of the
primary fuse(s)?
YES
Is there voltage across
terminals "1" & "2" of
transformer primary?
YES
NO
NO
NO
NO
Plug unit in and run
it.
Correct wiring
between primary
fuse(s) and power
supply.
Replace primary
fuse.
Correct wiring
between primary
fuse and
transformer.
YES
Is there voltage to
output side of
secondary fuse?
YES
Is there voltage to N.O.
of door switch?
YES
With door closed is
there voltage to COM
of door switch?
YES
Is there voltage to N.O.
of lint drawer switch?
YES
Is there voltage to
COM of lint drawer
switch with lint panel
closed?
YES
NO
NO
NO
NO
NO
Replace secondary
fuse.
Correct wiring
between N.O. and
output of secondary
fuse.
Check for proper
function of door
switch replace if
necessary.
Correct wiring
between N.O. on lint
drawer and COM on
door switch.
Check for proper
operation replace if
necessary.
70172201
Is there voltage across
terminals "2" & "3" of
transformer
secondary?
YES
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
NO
Replace
transformer.
Is there voltage at
"H4-1" on the EDC
control board?
YES
Replace EDC
Control.
NO
Correct wiring
between "H4-1" and
COM of lint drawer
switch.
T029D
T029D
25
Page 21
Will Not Start/Continue Running
EDC Control (Sheet 2 of 3)
Note: Tests conducted with vend
price satisfied and start button
pressed.
Is there voltage on "B"
terminal of motor
control relay?
NO
Correct wiring
between "B" and
"H4-4".
Is there voltage across
terminals "1" & "4" of
the fan motor?
YES
NO
Correct wiring
between fan motor
and motor control
relay.
3 phase. See
note on next
page
YES
Is the unit equipped
with single phase or
three phase power?
Single phase
Is there voltage to
terminal "5" of the
motor control relay?
YES
Is there voltage to
terminal "8" of motor
control relay?
YES
Is there supply voltage
to L1 and L2 of the
motor control relay?
YES
NO
NO
NO
between L1, L2 and
Correct wiring
between terminal "5"
and power supply.
Replace motor
control relay.
Correct wiring
power supply.
Does the fan motor
run?
YES
Is unit equipped with
single phase or three
phase power supply?
Three phase. See
note on next page.
Is there supply voltage
to L2 & L3 of motor
control relay?
YES
Is there voltage across
terminals L2 & T2 and
L3 & T3?
NO
Is there voltage at
terminal "6" of motor
control relay?
NO
Single phase
NO
YES
NO
Replace fan motor.
Correct wiring
between L2, L3 and
supply.
Replace motor
control relay.
Correct wiring
between terminal "6"
of motor control
relay and supply.
26
Is there votlage across
L1 & T1 and L2 & T2?
NO
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
YES
Replace motor
control relay.
YES
Is there voltage at
terminal "9" of motor
control relay?
YES
NO
Continued on next
page.
Replace motor
control relay.
T030D
T030D
70172201
Page 22
EDC Control (Sheet 3 of 3)
Will Not Start/Continue Running
Is there voltage across
terminals "1" & "4" of
cylinder motor?
YES
Does the cylinder
motor run?
YES
Motors are
operational.
Note: For high voltage three phase supply (380 volts
or higher), the cylinder and fan motors are supplied
by L1, L2, L3 through the motor relay terminals T1,
T2, T3. Make the appropriate adjustments when
doing voltage checks.
NO
NO
Correct wiring
between cylinder
motor and motor
control relay.
Replace cylinder
motor.
T031D
T031D
70172201
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
27
Page 23
Will Not Start/Continue Running
OPL Microprocessor Control
(Sheet 1 of 3)
Gas, steam and
electric heat.
Single and three phase
supply.
Reference voltage to
supply neutral.
Is power supplied to
unit?
NO
Connect supply
and run unit.
Is there voltage to
output of secondary
fuse?
NO
Replace secondary
fuse.
YES
Is there voltage to input
of primary fuse(s)?
YES
Is there voltage to
output of primary
fuse(s)?
YES
Is there voltage across
terminals "1" & "2" on
primary of
transformer?
YES
Is there voltage across
terminals "2" & "3" of
transformer
secondary?
NO
NO
NO
between transformer
NO
Correct wiring
between primary
fuse and supply.
Change primary
fuse.
Correct wiring
and primary fuse.
Replace
transformer.
YES
Is there voltage to
"N.O." terminal of door
switch?
YES
With door closed is
there voltage to "COM"
of door switch?
YES
Is there voltage to
"N.O." of lint panel
switch?
YES
Is there voltage to
"COM" of lint panel
switch with lint panel
closed?
NO
NO
NO
NO
Correct wiring
between "N.O."
terminal of door
switch and
secondary fuse.
Check for proper
operation, replace
door switch if
necessary.
Correct wiring
between "N.O." of
lint panel switch
and "COM" of
door switch.
Check for proper
operation and
replace lint panel
switch if necessary.
28
YES
Note: Reference voltage to
transformer secondary neutral
Is there voltage to input
of secondary fuse?
YES
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
terminal "3".
NO
Correct wiring
between secondary
fuse and
transformer.
YES
Is there voltage at
terminal "8" of OPL
Micro?
YES
Continued on next
page.
NO
Correct wiring
between terminal
"8" of OPL Micro
and "COM" of lint
panel switch.
T099D
T099D
70172201
Page 24
OPL Microprocessor Control
(Sheet 2 of 3)
OPL Start - Run Circuitry continued.
Tests conducted with cycle selected and
start key pad activated.
Is there voltage at
terminal "7" on OPL
Micro?
NO
Replace OPL Micro.
Is there voltage
across terminals
"1" & "4" of fan
motor?
YES
Will Not Start/Continue Running
NO
Correct wiring
between fan motor
and motor control
relay.
YES
Is
there voltage
across terminals
"B" & "A" of motor control relay
for "OM" model and terminals
"0" & "1" for "RM"
models?
YES
Is unit supplied with
single phase or three
phase power?
Three phase. See note on next page.
Is there voltage to L1
and L2 of the motor
control relay?
YES
Is ther voltage to T1
and T2 of the motor
control relay?
YES
Reference voltage to
supply neutral.
NO
motor control relay.
Single phase
NO
between L1, L2 and
NO
Correct wiring to
Correct wiring
power supply.
Replace motor
control relay.
Single phase
Does the fan
motor run?
YES
Does the unit
have reversing
capabilities?
NO
Does the unit
have single
phase or three
phase supply?
Three phase. See note on next page.
Is
there voltage
to L2 and L3 on
the motor control
relay?
YES
Is
there voltage
to T2 and T3 on
the motor control
relay?
NO
YES
NO
NO
Replace fan motor.
See cylinder
rotation. Either
forward or reverse.
Correct wiring
between L2, L3 and
power supply.
Replace motor
control relay.
70172201
Is there
voltage at terminal
"5" on the motor control
relay for "OM" models and
terminal "2" for "RM"
models?
YES
Is there
voltage across
terminals "5" & "8" of
the motor control relay for "OM"
models and terminals "2"
& "4" for "RM"
models?
NO
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
NO
YES
Correct wiring
between motor
control relay and
power supply.
Replace motor
control relay.
Is there voltage to
terminal "6" of motor
control relay?
YES
Is there voltage
across terminals "6" & "9" of
motor control relay?
NO
between terminal
NO
"6" motor control
relay and supply
YES
Continued on next
page.
Correct wiring
voltage.
Replace motor
control relay.
T008D
29
Page 25
Will Not Start/Continue Running
OPL Microprocessor Control
(Sheet 3 of 3)
Is there voltage across
terminals "1" & "4" of
the cylinder motor?
YES
Does the cylinder
motor run?
YES
Unit operational.
NOTE: For three phase high voltage (380volts or
higher), the cylinder and fan motors are supplied L1, L2,
L3 through the motor relay terminals T1, T2, T3. Make
the appropriate voltage checks while doing trouble
shooting.
NO
NO
Correct the wiring
between the
cylinder motor and
control relay.
Replace cylinder
motor.
T009D
30
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70172201
Page 26
Electric
Manual Timer (Sheet 1 of 3)
Will Not Run
With and without Time Delay Boards.
Single and Stacked units.
Single and 3 phase power supply.
Is there voltage at
terminal "C" on the
drying timer?
YES
NOTE: make sure drying
timer is in the "on"
Is there voltage at
terminal "B" on the
drying timer?
YES
Is there voltage across
terminals "7" and "8" of
CR1 relay?
YES
Is there voltage across
terminal "3" and "5" of
CR1 relay?
NO
position.
NO
NO
YES
Correct wiring
between drying
timer and lint panel
switch.
Replace drying
timer.
Correct the wiring
between CR1 relay
and terminal "B" on
drying timer.
Replace CR1 relay.
NO
Is the unit equipped
with a Time Delay
Board?
YES
Is there voltage across
"H1-6" & "H1-8" on
TMR1?
YES
**
Is there voltage across
terminals "H1-4" &
"H1-8" on TMR2?
YES
**
Is there voltage across
"DOB" contacts on
TMR2?
NO
NO
YES
Correct wiring to
TMR1.
Check for proper
operation of Air
Flow Switch.
Replace Time
Delay Board.
70172201
NO
NOTE: This test to be
made with Push to Start
Switch pressed in.
Is there voltage
across terminals "2A"
& "1A" of push to
start switch?
NO
NOTE: The "N.O." contact is closed in the rest
**
Is there voltage across
"COM" and "N.O." of
the air flow switch?
NO
Tested with the start switch pressed in.
**
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
YES
position due to the physical
Replace Push to
Start Switch.
mounting of the switch.
Adjust the air flow
YES
switch or replace if
inoperative.
CONTINUED
ON NEXT
PAGE.
YES
NO
**
Is there voltage across
terminals "7" & "8" of
CR2 Relay?
YES
Is there voltage across
terminals "5" & "3" on
the CR2 Relay?
NO
**
Is there voltage across
coils "B" & "A" of the
Motor Control Relay?
NO
YES
NO
Correct wiring
between CR2
Relay and Air
Flow Switch.
Replace CR2
Relay.
Correct wiring
between Motor
Control Relay
and Air Flow
Switch.
T051D
T051D
31
Page 27
Will Not Run
Electric
Manual Timer (Sheet 2 of 3)
Is this a single phase
or 3 phase unit?
Single phase
**
Is there voltage across
terminal "7" & "4" of the
Motor Control Relay?
NO
NO
Is there voltage at
terminal "5" on the
motor control relay to
to supply neutral?
YES
Is there voltage across
terminal "5" & "8" of the
motor control relay?
NO
3 phase
YES
NO
YES
Replace Motor
Control Relay.
Correct wiring
between terminal "5"
and supply voltage.
Replace motor
control relay.
Is there voltage across
terminals "14" & "13" of
motor control relay?
NO
Is there voltage to "L1"
of motor control relay?
YES
Is there voltage to "L2"
of motor control relay?
YES
Is there voltage across
"L1" to "T1" and "L2" to
"T2" on the motor
control relay?
NO
YES
NO
NO
YES
Replace motor
control relay.
Correct wiring
between "L1" and
power supply.
Correct wiring
between "L2" and
power supply.
Replace motor
control relay.
Is there voltage across
terminals "1" & "4" of
Fan Motor?
YES
Does the Fan Motor
Run?
YES
**
Tested with the start switch pressed in.
NO
NO
Correct wiring
between Fan
Motor and contact
"8" on the Motor
Control Relay.
Replace the Fan
Motor.
Is there voltage across
terminals "3" & "5" of
the fan motor
centrifugal switch with
the fan motor running?
NO
Continued on next
page.
Note: Only for non time
delay machines
YES
Replace Fan
Motor.
T052D
T052D
32
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70172201
Page 28
Electric
Manual Timer (Sheet 3 of 3)
Will Not Run
Is unit single phase or
3 phase?
Single phase.
Is there voltage to
terminal "6" on the
motor control relay?
YES
Is there voltage across
terminal "6" & "9" of the
motor control relay?
NO
Is there voltage at
terminals "1" & "4" of
the Cylinder Motor?
YES
Three phase.
NO
YES
NO
Correct wiring
between terminal
"6" and power
supply.
Replace motor
control relay.
Correct wiring
between Cylinder
Motor and contact
"9" on the Motor
Control Relay.
Is there voltage to "L2"
on motor control relay?
YES
Is there voltage to "L3"
on motor control relay?
YES
Is there voltage across
"L2 to T2" and "L3 to
T3" on the motor
control relay?
NO
NO
NO
YES
Correct wiring
between motor
control relay and
supply.
Correct wiring
between motor
control relay and
supply.
Replace motor
control relay.
70172201
Does the Cylinder
Motor Run?
YES
The Cylinder and
Fan Motors are
operational.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
NO
Replace the
Cylinder Motor.
T053D
T053D
33
Page 29
Will Not Run
Electric
Rotary Coin Drop (Sheet 1 of 3)
Tumblers Single & Stack with and without
time delay. Single and Three phase power.
Tested with vend price
**
satisfied and with start
**
Is there voltage across
terminals "2A" & "1A"
of push to start
switch?
NO
Is there voltage to
COM of the Air Flow
Switch?
YES
**
Is there voltage across
COM and "N.O." of
the air flow switch?
NO
switch pressed in.
YES
Note: Reference
voltage to transformer
neutral.
NO
NOTE: The N.O. contact is closed in the rest
position due to the physical mounting
of the switch.
YES
Replace Push to
Start Switch.
Correct wiring
between COM of Air
Flow Switch and
"1A" on Start Switch.
Replace inoperative
switch or correct air
flow vane operation.
**
Is there voltage across
terminals "7" & "8" of
CR2 Relay?
YES
**
Is there voltage across
terminals "5" & "3" on
the CR2 Relay?
NO
**
Is there voltage across
the coil of the Motor
Control Relay?
YES
Is unit Single
phase or Three
phase?
Single Phase
NO
YES
NO
Three phase
please see not.
Correct wiring
between CR2
Relay and Air
Flow Switch.
Replace CR2
Relay.
Correct wiring
between Motor
Control Relay
and Air Flow
Switch.
Continued on
next page
COLUMN 2.
Is the unit equipped
with a Time Delay
Board?
YES
**
Is there voltage across
terminals "H1-4" &
"H1-8" on TMR2?
YES
**
Is there voltage across
"DOB" contacts on
TMR2?
NO
NO
NO
YES
Check for proper
operation of Air
Flow Switch and
check wiring.
Replace Time
Delay Board.
Tested with the start switch pressed in.
**
**
Is there voltage across
terminal "7" & "4" of the
Motor Control Relay?
NO
Is there voltage at
terminal "5" on the
motor control relay?
YES
Continued on next
page COLUMN 1.
YES
NO
Replace Motor
Control Relay.
Correct wiring
between
terminal "5"
and supply
voltage.
T072D
T072D
34
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70172201
Page 30
Electric
Rotary Coin Drop (Sheet 2 of 3)
Will Not Run
COLUMN 1
Is there voltage across
terminal "5" & "8" of the
motor control relay?
NO
Is there voltage across
terminals "1" & "4" of
Fan Motor?
YES
Does the Fan Motor
Run?
YES
Is there voltage across
terminals "3" & "5" of
the fan motor
centrifugal switch with
the fan motor running?
YES
Replace motor
control relay.
Correct wiring
NO
NO
YES
between Fan
Motor and contact
"8" on the Motor
Control Relay.
Replace the Fan
For units without Time
Delay Boards.
Replace Fan
Motor.
Motor.
COLUMN 2
Is there voltage across
terminal "14" & "13" of
motor control relay?
NO
Is there voltage to "L1" &
"L2" terminals on motor
control relay?
YES
Is there voltage to "T1" &
"T2" terminals on motor
control relay?
NOTE: For Hi voltage three phase supply
(380volts or higher), the cylinder and fan motor
are supplied "L1", "L2", "L3" through the motor relay
terminals "T1", "T2", "T3". Make the appropriate
adjustments when doing trouble shooting.
YES
NO
NO YES
between "L1", "L2"
Replace motor
control relay.
Correct wiring
and supply.
Replace motor
control relay.
NO
Is the machine
supplied with single
phase or three phase
power?
Single Phase
Is there voltage to
terminal "6" on the
motor control relay?
YES
Continued on next
page COLUMN 1.
Three Phase
Please see note.
Correct wiring
NO
between terminal
"6" and power
supply.
Is there voltage to
"L2" & "L3" terminals
on motor control
relay?
YES
Is there voltage
across "L2" to "T2" and
"L3" to "T3"?
NO
Does the cylinder
motor run?
YES
CYLINDER AND
FAN MOTORS ARE
OPERATIONAL.
NO
YES
NO
Correct wiring
between supply
and "L2" & "L3"
terminals.
Replace motor
control relay.
Replace cylinder
motor.
T073D
T073D
70172201
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
35
Page 31
Will Not Run
Electric
Rotary Coin Drop (Sheet 3 of 3)
COLUMN 1
Is there voltage across
terminals "6" & "9" of
motor control relay?
NO
Is there voltage at
terminals "1" & "4" of
the Cylinder Motor?
YES
Does the Cylinder
Motor Run?
YES
The Cylinder and
Fan Motors are
operational.
YES
NO
NO
Replace motor
control relay.
Correct wiring
between Cylinder
Motor and contact
"9" on the Motor
Control Relay.
Replace the
Cylinder Motor.
T074D
T074D
36
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70172201
Page 32
Gas
Manual Timer (Sheet 1 of 2)
Will Not Run
No motor run (run circuit) Manual T
and stacked units with and without Time Delay
Boards. GAS UNIT.
Is there voltage at
terminal “c” on the
drying timer?
YES
Is there voltage at
terminal “b” on the
drying timer?
YES
Is there voltage across
terminals “7” and “8” of
CR1 relay?
YES
Is there voltage across
terminal “3” and “5” of
CR1 relay?
umblers Single
NO
NOTE: make sure drying
timer is in the “ on”
position.
NO
NO
YES
Correct wiring
between drying
timer and lint panel
switch.
Replace drying
timer.
Correct the wiring
between CR1 relay
and terminal “b” on
drying timer.
Replace CR1 relay.
NO
Is the unit equipped
with a Time Delay
Board?
YES
Is there voltage across
“ H1-6” & “ H1-8” on
TMR1?
YES
**
Is there voltage across
terminals “ H1-4” &
“ H1-8” on TMR2?
YES
**
Is there voltage across
"DOB" contacts on
TMR2?
NO
NO
YES
Correct wiring to
TMR1.
Check for proper
operation of
Airflow Switch.
Replace Time
Delay Board.
NO
NOTE: This test to be
made with Push to Start
Switch pressed in.
Is there voltage
across terminals “ 2A”
& “ 1A” of push to
Start switch?
NO
**
Is there voltage across
“ COM” and “ N.O.” of
the Airflow switch?
NO
Tested with the start switch pressed in.
**
YES
NOTE: The N.O. contact is closed in the rest
position due to the physical mounting
of the switch.
YES
Replace Push to
Start Switch.
Adjust the Airflow
switch or replace if
inoperative.
CONTINUED
ON NEXT
PAGE.
YES
NO
**
Is there voltage across
terminals “7” & “8” of
CR2 Relay?
YES
Is there voltage across
terminals “5” & “3” on
the CR2 Relay?
NO
**
Is there voltage across
coils “B” & “A” of the
Motor Control Relay?
NO
YES
NO
Correct wiring
between CR2
Relay and
Airflow Switch.
Replace CR2
Relay.
Correct wiring
between Motor
Control Relay
and Airflow
Switch.
T042D
T042D
70172201
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
37
Page 33
Will Not Run
Gas
Manual Timer (Sheet 2 of 2)
**
Is there voltage across
terminal "7" & "4" of the
Motor Control Relay?
YES
Does the Fan Motor
Run?
NO
Replace the Fan
Motor.
NO
Is there voltage at
terminal "5" on the
motor control relay to
to supply neutral?
YES
Is there voltage across
terminal "5" & "8" of the
motor control relay?
NO
Is there voltage across
terminals "1" & "4" of
Fan Motor?
NO
YES
NO
Replace Motor
Control Relay.
Correct wiring
between terminal "5"
and supply voltage.
Replace motor
control relay.
Correct wiring
between Fan
Motor and contact
"8" on the Motor
Control Relay.
YES
Is there voltage across
terminals "3" & "5" of
the fan motor
centrifugal switch with
the fan motor running?
NO
Is there voltage to
terminal "6" on the
motor control relay and
supply neutral?
YES
Is there voltage across
terminal "6" & "9" of the
motor control relay?
NO
Is there voltage at
terminals "1" & "4" of
the Cylinder Motor?
YES
Note: Only for non time
delay machines
YES
Replace Fan
Motor.
Correct wiring
NO
between terminal
"6" and power
supply.
YES
NO
Replace motor
control relay.
Correct wiring
between Cylinder
Motor and contact
"9" on the Motor
Control Relay.
38
YES
Tested with the start switch pressed in.
**
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Does the Cylinder
Motor Run?
YES
The Cylinder and
Fan Motors are
operational.
NO
Replace the
Cylinder Motor.
T043D
T043D
70172201
Page 34
Gas
Rotary Coin Drop (Sheet 1 of 2)
Will Not Run
& Stack with and without time delay.
Single
Gas units.
**
**
Is there voltage across
terminals "2A" & "1A"
of push to start
switch?
NO
voltage to transformer
Is there voltage to
COM of the Air Flow
Switch?
YES
NOTE: The N.O. contact is closed in
the rest position due to the physical
**
Is there voltage across
"COM" and "N.O." of
the air flow switch?
NO
Tested with start switch
Note: Reference
neutral.
mounting of the switch.
pressed in.
YES
NO
YES
Replace Push to
Start Switch.
Correct wiring
between COM of Air
Flow Switch and
"1A" on Start Switch.
Adjust the air flow
switch or replace if
inoperative.
**
Is there voltage across
"DOB" contacts (H1-4
and H1-5) on TMR2?
NO
**
Is there voltage across
terminals "7" & "8" of
CR2 Relay?
YES
**
Is there voltage across
terminals "5" & "3" on
the CR2 Relay?
NO
**
Is there voltage across
coils "B" & "A" of the
Motor Control Relay?
YES
NO
YES
NO
Replace Time
Delay Board.
Correct wiring
between CR2
Relay and Air
Flow Switch.
Replace CR2
Relay.
Correct wiring
between Motor
Control Relay
and Air Flow
Switch.
Is the unit equipped
with a Time Delay
Board?
YES
Is there voltage across
"H1-6" & "H1-8" on
TMR1?
YES
**
Is there voltage across
terminals "H1-4" &
"H1-8" on TMR2?
YES
NO
NO
NO
Correct wiring to
TMR1.
Check for proper
operation of Air
Flow Switch and
check wiring.
**
Tested with the start switch pressed in.
YES
**
Is there voltage across
terminal "7" & "4" of the
Motor Control Relay?
NO
Is there voltage at
terminal "5" on the
motor control relay?
YES
CONTINUED
ON NEXT
PAGE.
YES
NO
Replace Motor
Control Relay.
Correct wiring
between
terminal "5"
and supply
voltage.
T088D
T088D
70172201
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
39
Page 35
Will Not Run
Gas
Rotary Coin Drop (Sheet 2 of 2)
No Motor Run (run circuit)
Is there voltage across
terminal "5" & "8" of the
motor control relay?
NO
Is there voltage across
terminals "1" & "4" of
Fan Motor?
YES
Does the Fan Motor
Run?
YES
Is there voltage
across terminals "3" &
"5" of the fan motor centrifugal
switch with the fan
motor running?
YES
NO
NO
YES
Replace motor
control relay.
Correct wiring
between Fan
Motor and contact
"8" on the Motor
Control Relay.
Replace the Fan
Motor.
Replace Fan
Motor.
Is there voltage at
terminals "1" & "4" of
the Cylinder Motor?
YES
Does the Cylinder
Motor Run?
YES
The Cylinder and
Fan Motors are
operational.
NO
NO
Correct wiring
between Cylinder
Motor and contact
"9" on the Motor
Control Relay.
Replace the
Cylinder Motor.
NO
Is there voltage to
terminal "6" on the
motor control relay?
YES
Is there voltage across
terminal "6" & "9" of the
motor control relay?
NO
NO
YES
Correct wiring
between terminal
"6" and power
supply.
Replace motor
control relay.
**
Tested with the start switch pressed in.
T089D
T089D
40
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70172201
Page 36
Steam
Manual Timer (Sheet 1 of 2)
No motor run (run circuit) Manual Tumblers.
Single and stacked units with and without
time delay board. Steam heat.
Will Not Run
Is there voltage at
terminal “C” on the
drying timer?
YES
Is there voltage at
terminal “B” on the
drying timer?
YES
Is there voltage across
terminals “7” and “8” of
CR1 relay?
YES
Is there voltage across
terminal “3” and “5” of
CR1 relay?
NO
Is there voltage
across terminals “ 2A”
& “ 1A” of push to
Start switch?
NO
timer and lint panel
NOTE: Make sure drying
timer is in the "on"
position.
NO
Correct the wiring
NO
between CR1 relay
and terminal “B” on
YES
Replace CR1 relay.
NOTE: This test to be
made with Push to Start
Switch pressed in.
YES
Replace Push to
Correct wiring
between drying
switch.
Replace drying
timer.
drying timer.
Start Switch.
NO
Is the unit equipped
with a Time Delay
Board?
YES
Is there voltage across
“ H1-6” & “ H1-8” on
TMR1?
YES
**
Is there voltage across
terminals “ H1-4” &
“ H1-8” on TMR2?
YES
**
Is there voltage across
“ DOB” contacts on
TMR2?
NO
**
Is there voltage across
terminals “7” & “8” of
CR2 Relay?
NO
NO
YES
NO
Correct wiring to
TMR1.
Check for proper
operation of
Airflow Switch.
Replace Time
Delay Board.
Correct wiring
between CR2
Relay and
Airflow Switch.
70172201
NO
NOTE: The N.O. contact is closed in
the rest position due to the physical
**
Is there voltage across
“ COM” and “ N.O.” of
the Airflow switch?
NO
Tested with the start switch pressed in.
**
mounting of the switch.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
YES
Adjust the Airflow
switch or replace if
inoperative.
CONTINUED
ON NEXT
PAGE.
YES
YES
Is there voltage across
terminals “5” & “3” on
the CR2 Relay?
NO
**
Is there voltage across
“ B” & “ A” of the Motor
Control Relay ?
YES
NO
Replace CR2
Relay.
Correct wiring
between Motor
Control Relay
and Airflow
Switch.
T017D
T017D
41
Page 37
Will Not Run
Steam
Manual Timer (Sheet 2 of 2)
**
Is there voltage across
terminal "7" & "4" of the
Motor Control Relay?
YES
Does the Fan Motor
Run?
NO
Replace the Fan
Motor.
NO
Is there voltage at
terminal "5" on the
motor control relay to
to supply neutral?
YES
Is there voltage across
terminal "5" & "8" of the
motor control relay?
NO
Is there voltage across
terminals "1" & "4" of
Fan Motor?
NO
YES
NO
Replace Motor
Control Relay.
Correct wiring
between terminal
"5" and supply
voltage.
Replace motor
control relay.
Correct wiring
between Fan
Motor and contact
"8" on the Motor
Control Relay.
YES
Is there voltage across
terminals "3" & "5" of
the fan motor
centrifugal switch with
the fan motor running?
NO
Is there voltage to
terminal "6" on the
motor control relay and
supply neutral?
YES
Is there voltage across
terminal "6" & "9" of the
motor control relay?
NO
Is there voltage at
terminals "1" & "4" of
the Cylinder Motor?
YES
Note: only for non time
delay machines
YES
Replace Fan
Motor.
Correct wiring
NO
between terminal
"6" and power
supply.
YES
Replace motor
control relay.
Correct wiring
NO
between Cylinder
Motor and contact
"9" on the Motor
Control Relay.
42
YES
Tested with the start switch pressed in.
**
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Does the Cylinder
Motor Run?
YES
The Cylinder and
Fan Motors are
operational.
NO
Replace the
Cylinder Motor.
T018D
T018D
70172201
Page 38
Steam
Rotary Coin Drop (Sheet 1 of 2)
Single & Stack
with and without time delay.
Steam units.
Is there voltage across
terminals "2A" & "1A"
of push to start
Is there voltage to
COM of the Air Flow
**
switch?
Switch?
**
Tested with start switch
pressed in and vend
NO
Note: Reference
voltage to transformer
satisfied.
neutral.
YES
NO
between COM of Air
"1A" on Start Switch.
Replace Push to
Start Switch.
Correct wiring
Flow Switch and
**
Is there voltage across
"DOB" contacts on
TMR2?
NO
**
Is there voltage across
terminals "7" & "8" of
CR2 Relay?
YES
YES
NO
Replace Time
Delay Board.
Correct wiring
between CR2
Relay and Air
Flow Switch.
Will Not Run
YES
NOTE: The N.O. contact is closed in the rest
**
Is there voltage across
"COM" and "N.O." of
the air flow switch?
NO
Is the unit equipped
with a Time Delay
Board?
YES
Is there voltage across
"H1-6" & "H1-8" on
TMR1?
YES
**
Is there voltage across
terminals "H1-4" &
"H1-8" on TMR2?
YES
position due to the physical mounting
of the switch.
Adjust the air flow
YES
switch or replace if
inoperative.
NO
NO
Correct wiring to
TMR1.
Check for proper
NO
operation of Air
Flow Switch and
check wiring.
**
Is there voltage across
terminals "5" & "3" on
the CR2 Relay?
NO
**
Is there voltage across
"B" & "A" of the Motor
Control Relay?
YES
**
Is there voltage across
terminal "7" & "4" of the
Motor Control Relay?
NO
Is there voltage at
terminal "5" on the
motor control relay?
YES
CONTINUED
ON NEXT
PAGE.
YES
NO
YES
NO
Replace CR2
Relay.
Correct wiring
between Motor
Control Relay
and Air Flow
Switch.
Replace Motor
Control Relay.
Correct wiring
between
terminal "5"
and supply
voltage.
70172201
**
Tested with the start switch pressed in.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
T064D
T064D
43
Page 39
Will Not Run
Steam
Rotary Coin Drop (Sheet 2 of 2)
No Motor Run (run circuit)
Is there voltage across
terminal "5" & "8" of the
motor control relay?
NO
Is there voltage across
terminals "1" & "4" of
Fan Motor?
YES
Does the Fan Motor
Run?
YES
Is there voltage across
terminals "3" & "5" of
the fan motor
centrifugal switch with
the fan motor running?
YES
Replace motor
control relay.
Correct wiring
NO
NO
Only for units without
time delay boards.
YES
between Fan
Motor and contact
"8" on the Motor
Control Relay.
Replace the Fan
Motor.
Replace Fan
Motor.
Is there voltage at
terminals "1" & "4" of
the Cylinder Motor?
YES
Does the Cylinder
Motor Run?
YES
The Cylinder and
Fan Motors are
operational.
NO
NO
Correct wiring
between Cylinder
Motor and contact
"9" on the Motor
Control Relay.
Replace the
Cylinder Motor.
NO
Is there voltage to
terminal "6" on the
motor control relay?
YES
Is there voltage across
terminal "6" & "9" of the
motor control relay?
NO
NO
YES
Correct wiring
between terminal
"6" and power
supply.
Replace motor
control relay.
**
Tested with the start switch pressed in.
T065D
T065D
44
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70172201
Page 40
Electric
Manual Timer (Sheet 1 of 2)
NOTE: The following tests are conducted with
the Heat Timer in the "ON" position with the
machine running and calling for heat. Voltage
checks are referenced to transformer neutral.
Will Not Heat
With and without Time Delay
Board, Single and Stacked units, Single and
3 Phase power supply.
YES
Is there voltage across
terminals "1" & "6" of
the Temp Control Bd?
YES
Is there voltage across
terminals "5" & "6" of
the Temp Control Bd?
NO
Is the thermistor
shorted or open?
NO
Is temperature
selection switch
shorted or open?
NO
Replace the
Temperature
Control Board.
NO
YES
YES
Is there
voltage to
terminal "3" of
fan motor?
Replace thermistor.
Replace selection
switch.
NO
YES
Correct wiring
between fan motor
terminal "3" and
CR1 terminal "4".
YES
Is there voltage at Air
Flow Switch (AFS)
"N.C." terminal to
transformer neutral?
YES
Is there voltage at
terminal "6" on CR1 to
transformer neutral?
YES
Is there voltage from
terminal "4" on CR1 to
transformer neutral?
YES
Is unit equipped with
time delay board?
NO
Is there voltage from
terminal "6" on CR2 to
transformer neutral?
YES
Replace inoperative
NO
switch or correct air
flow vane operation.
Correct wiring
NO
between A.F.S. and
terminal "6" on CR1.
NO
Replace CR1.
Correct wiring
NO
between terminal "6"
on CR2 to terminal
"4" on CR1.
70172201
CONTINUED
ON NEXT
PAGE
Is there voltage from
terminal "4" on CR2 to
Is there voltage
at terminal 3 & 5
of fan motor?
YES
Correct wiring
between motor
terminal "5" and
Temp Control
Board terminal "1".
NO
Replace fan motor.
transformer neutral?
YES
Correct wiring
between CR2
terminal "4" &
terminal "1" on
Temp Control
Board.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
NO
Replace CR2.
T054D
T054D
45
Page 41
Will Not Heat
Electric
Manual Timer (Sheet 2 of 2)
NO HEAT CONTINUED
Note: Voltage checks are referenced to
transformer neutral.
Is there voltage to the
input side of the
Cabinet Limit?
YES
Is there voltage to the
output side of the
Cabinet Limit?
YES
Is there voltage to the
input side of the Stove
Limit?
YES
Is there voltage to the
output side of the Stove
Limit?
NO
NO
NO
NO
Correct wiring
between Cabinet
Limit and Temp
Control Board.
Replace the Cabinet
Limit.
Correct wiring
between Stove limit
and Cabinet Limit.
Replace the Stove
Limit.
Do the elements
produce heat?
YES
UNIT
OPERATIONAL
NO
Replace elements.
YES
Is there voltage across
"HC1" & "HC2"
element contactor
coils?
YES
Is there votlage across
the elements?
YES
NO
NO
Correct wiring
between element
contactor coils and
stove limit.
Check wiring
between elements,
contactors and
supply. Correct if
necessary.
T055D
T055D
46
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70172201
Page 42
Electric
Rotary Coin Drop (Sheet 1 of 2)
Will Not Heat
Note: Tests are conducted with unit running
and calling for heat.
All voltage checks are referenced to
transformer neutral.
Replace
thermistor.
NO
thermistor
operational?
NO
Is there voltage on
"FS-2" of EDC control?
YES
Is there voltage
on "FS-1" of
EDC control?
YES
Is there voltage on
COM of air flow
switch?
YES
Correct wiring
between "FS-2" and
COM of lint drawer.
NO NO
Is the
Correct wiring
between COM of air
flow switch and
"FS-1" of EDC
Single and stacked units with single and three
Replace EDC
control.
YES
control.
phase supply.
Is there voltage to the
Is there voltage on
terminal "3" of fan
motor centrifugal
switch?
YES
Is there voltage at
terminal "5" of fan
motor centrifugal
switch?
YES
input side of the
cabinet limit?
YES
NO
NO
NO
Correct wiring
between terminal
"3" of fan motor
centrifugal switch
and terminal "4" of
motor control relay.
Replace fan motor.
Correct wiring
between cabinet
limit and terminal
"5" of fan motor
centrifugal switch.
Is there voltage at
"N.C." terminal of air
flow switch?
YES
Is there voltage on
terminal "7" of motor
control relay?
YES
Is there voltage at
terminal"4" of motor
control relay?
YES
NO
NO
NO
Check for proper
function of air flow
switch and replace
if necessary.
Correct wiring
between terminal 7
on motor control
relay and N.C.
terminal on air flow
switch.
Replace motor
control relay.
Is there voltage at the
output of the cabinet
limit?
YES
Is there voltage to the
input side of the stove
limit?
YES
Continued on next
page.
NO
NO
Replace cabinet
limit.
Correct wiring
between stove limit
and cabinet limit.
T034D
T034D
70172201
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
47
Page 43
Will Not Heat
Electric
Rotary Coin Drop (Sheet 2 of 2)
EDC No Heat
continued.
Is there voltage to the
output side of the stove
limit?
YES
Is there voltage across
coils "HC1" & "HC2"?
YES
Is there voltage across
the heating elements?
YES
Do the elements
produce heat?
YES
NO
NO
NO
NO
Replace the stove
limit.
Correct wiring to
the coils of "HC1"
and "HC2".
Correct wiring
between elements
and supply. Replace
"HC1" and or "HC2"
if necessary
Replace elements.
48
Unit operational.
T035D
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
T035D
70172201
Page 44
Electric
Rotary Coin Drop (with and without time delay board)
(Sheet 1 of 2)
Single & Stacked
Tumblers with and
without time delay.
Single and Three phase
uiits.
Will Not Heat
YES
Is there voltage across
across terminals "1" &
"6" of the Temp
Control Board?
YES
Is there voltage across
terminals "5" & "6" of
the Temp Control Bd?
NO
Is the thermistor
shorted or open?
NO
Is temperature
selection switch
shorted or open?
NO
Replace the
Temperature
Control Board.
Is there voltage
on terminal "3" of fan
motor to transformer
neutral?
YES
NO
YES
Replace thermistor.
YES
NO
Replace selection
switch.
Correct wiring
between terminal
"3" of fan motor
and N.C. terminal
on Switch "B".
YES
Is there voltage at Air
Flow Switch "N.C."
terminal to transformer
neutral?
YES
Is there voltage at
COM on Switch "B" to
transformer neutral?
YES
Is there voltage from
"N.C." on Switch "B" to
transformer neutral?
YES
Is the unit equipped
with a Time Delay
Board?
NO
Is there voltage from
terminal "6" on CR2 to
transformer neutral?
YES
Adjust the Air Flow
NO
Switch or replace if
Correct wiring
NO
between air flow
switch and COM on
NO
Replace Switch "B".
Correct wiring
NO
between terminal "6"
on CR2 to terminal
"N.C." on Switch "B".
inoperative.
Switch "B".
70172201
CONTINUED
ON NEXT
PAGE
With fan motor
running is there voltage
from terminal "5" to
transformer neutral?
YES
Is there voltage on
terminal "1" of Temp
Board to transformer
neutral?
YES
Power supply to
Temp Control Board
is good.
NO
Replace Fan Motor.
Correct wiring
between terminal
NO
"1" of Temp Board
to terminal "5"
of fan motor.
Is there voltage from
terminal "4" on CR2 to
transformer neutral?
YES
Correct wiring
between terminal
"4" on CR2 &
terminal "1" on
Temp Control
Board.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
NO
Replace CR2.
T077D
T077D
49
Page 45
Will Not Heat
Electric
Rotary Coin Drop (with and without time delay board)
(Sheet 2 of 2)
NO HEAT CONTINUED
Note: Voltage checks are referenced to
transformer neutral.
Is there voltage to the
input side of the
Cabinet Limit?
YES
Is there voltage to the
output side of the
Cabinet Limit?
YES
Is there voltage to the
input side of the Stove
Limit?
YES
Is there voltage to the
output side of the Stove
Limit?
NO
NO
NO
NO
Correct wiring
between Cabinet
Limit and Temp
Control Board.
Replace the
Cabinet Limit.
Correct wiring
between Stove limit
and Cabinet Limit.
Replace the Stove
Limit.
Do the elements
produce heat?
YES
UNIT
OPERATIONAL
NO
Replace elements.
50
YES
Is there voltage across
the coils of "HC1" &
"HC2"?
YES
Is there voltage across
the elements?
YES
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
NO
NO
Correct the wiring
to the coils.
Check the wiring
between elements,
contactors and
supply. Correct if
necessary.
T078D
T078D
70172201
Page 46
Electric/Gas
OPL Microprocessor (Sheet 1 of 3)
Single and three phase supply.
Reference voltage to
transformer neutral
Is there votlage at
terminal "5" on OPL
Micro?
terminal "3".
Note: Testing conducted with unit running
YES
Continued on next
page column 2.
and calling for heat.
Is there voltage across
terminals "2" & "3" of
transformer
secondary?
NO
Replace
transformer.
Will Not Heat
NO
Is the thermister
operating properly?
YES
Reference voltage to
supply neutral.
Is power supplied to
unit?
YES
Is there voltage to input
of primary fuse(s)?
YES
Is there voltage to
output of primary
fuse(s)?
Test conducted with unit
running and calling for heat.
NO
Replace thermister.
NO
Connect supply and
run unit.
NO
NO
Correct wiring
between primary
fuse and supply.
Change primary
fuse.
YES
Note: Reference voltage to
transformer secondary neutral
Is there voltage to input
of secondary fuse?
YES
Is there voltage to
output of secondary
fuse?
YES
Is there voltage to
"N.O." terminal of door
switch?
YES
With door closed is
there voltage to "COM"
of door switch?
terminal "3".
NO
NO
NO
NO
Correct wiring
between secondary
fuse and
transformer.
Replace secondary
fuse.
Correct wiring
between "N.O."
terminal of door
switch and
secondary fuse.
Check for proper
operation, replace
door switch if
necessary.
70172201
YES
Is there voltage across
terminals "1" & "2" on
primary of
transformer?
YES
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
NO
between transformer
Correct wiring
and primary fuse.
YES
Is there voltage to
"N.O." of lint panel
switch?
YES
Continued on next
page column 1.
NO
Correct wiring
between "N.O." of
lint panel switch
and "COM" of door
switch.
T010D
T010D
51
Page 47
Will Not Heat
Electric/Gas
OPL Microprocessor (Sheet 2 of 3)
NO HEAT
Column 1
Column 2
The following tests are
conducted with the unit running
and calling for heat.
Is there voltage to
"COM" of lint panel
switch with lint panel
closed?
YES
Is there voltage at
terminal "8" of OPL
Micro?
YES
Is there voltage to
terminal "13" of OPL
Micro?
YES
Is there voltage at
terminal "6" of OPL
Micro?
YES
Replace OPL Micro.
Is there voltage to
terminal 14 on motor
control relay?
YES
NO
NO
NO
NO
NO
Check for proper
operation and
replace lint panel
switch if necessary.
Correct wiring
between terminal
"8" of OPL Micro
and "COM" of lint
panel switch.
Replace OPL Micro.
Correct wiring
between terminal
"6" & "13" on OPL
Micro.
Correct wiring
between terminal
"14" on motor
control relay and
N.C. terminal of air
flow switch.
Three phase
Is there voltage at
"COM" of air flow
switch?
YES
Is there voltage at
"N.C." terminal of air
flow switch?
YES
Is the unit supplied with
single phase or three
phase power?
single phase
Is there voltage at
terminal "7" of motor
control relay for "OM"
models or terminal "8"
for "RM" models?
YES
Is there voltage at
terminal "4" of motor
control relay for "OM"
models or terminal "6"
for "RM" models?
YES
Is there voltage at
terminal "3" of fan
motor centrifugal
switch?
NO
NO
NO
NO
NO
Correct wiring
between "COM" &
OPL Micro.
Check for proper
operation and
replace if
necessary.
Correct wiring
between terminal
"7/8" of motor
control relay and
"N.C." of air flow
switch.
Replace motor
control relay.
Correct wiring
between fan motor
centrifugal switch
and motor control
relay.
52
Is there votlage across
terminals 14 & 13 of
motor control relay?
YES
Replace motor
control relay.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
NO
YES
Is there voltage at
terminal "5" of fan
motor centrifugal
switch?
YES
Continued on next
page.
NO
Replace fan motor.
T011D
T011D
70172201
Page 48
Electric/Gas
OPL Microprocessor (Sheet 3 of 3)
Continued from column 2 of
previous page.
Will Not Heat
Is there voltage to the
input of the cabinet
limit?
YES
Is there voltage to
output of cabinet limit?
YES
Is there voltage to input
of stove limit?
YES
Is there voltage to the
output side of the stove
limit?
YES
NO
NO
NO
NO
Correct wiring
between cabinet
limit and terminal
"5" of fan motor
centrifugal switch.
Replace cabinet
limit.
Correct wiring
between stove limit
and cabinet limit.
Replace stove limit.
Is there voltage to
terminal "1" of ICM
board?
YES
Is there voltage across
the coils of the gas
valve?
YES
Is there gas flow
through the valve?
YES
NO
Does the ignitor spark?
NO
NO
NO
YES
YES
Replace ICM board.
Correct wiring to
gas valve coils.
Replace the coils or
complete gas valve.
Unit is operational. Is there a flame?
Check gas
pressures and
adjust if necessary.
Is the unit equipped
with gas heat or
electric heat?
GAS
Is there voltage to
terminal "2" of ICM
board?
YES
ELECTRIC
NO
Correct wiring
between ICM board
and stove limit.
UNIT
OPERATIONAL.
NO
Replace igniter or
ignition cable.
Is there voltage across
HC1 & HC2 coils?
YES
Do the elements
produce heat?
YES
NO
NO
Correct the wiring
to the HC1 and/or
HC2 coils.
Correct wiring
between supply,
contacts and
elements. Replace
contactors and/or
elements if
necessary.
T012D
T012D
70172201
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
53
Page 49
Will Not Heat
Gas
EDC Models (Sheet 1 of 2)
Note: Tests are conducted with unit
running and calling for heat.
All voltage checks are referenced
to transformer neutral.
Is there voltage on
"FS-2" of EDC control?
YES
Replace
thermistor.
Is there voltage
on "FS-1" of
EDC control?
YES
Is there voltage on
COM of air flow
NO
switch?
YES
Single and stacked gas
between "FS-2" and
COM of lint drawer.
NO
Is the
thermistor
between COM of air
Correct wiring
Correct wiring
flow switch and
"FS-1" of EDC
NO
operational?
NO
units.
Replace EDC
control.
YES
control.
Is there voltage on
terminal "3" of fan
motor centrifugal
switch?
YES
Is there voltage across
terminals "3" & "5" of
fan motor centrifugal
switch?
NO
Is there voltage to the
input side of the
cabinet limit?
YES
NO
YES
NO
Correct wiring
between terminal
"3" of fan motor
centrifugal switch
and terminal "4" of
motor control relay.
Replace fan motor.
Correct wiring
between cabinet
limit and terminal
"5" of fan motor
centrifugal switch.
Is there voltage across
COM & "N.C." terminal
of air flow switch?
NO
Is there voltage on
terminal "7" of motor
control relay?
YES
Is there voltage across
terminals "7" & "4" of
motor control relay?
NO
YES
NO
YES
Check for proper
function of air flow
switch and replace
if necessary.
Correct wiring
between terminal
"7" on motor
control relay and
N.C. terminal on
air flow switch.
Replace motor
control relay.
Is there voltage across
cabinet limit?
NO
Is there voltage to the
input side of the stove
limit?
YES
Continued on next
page.
YES
NO
Replace cabinet
limit.
Correct wiring
between stove limit
and cabinet limit.
T032D
T032D
54
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70172201
Page 50
Gas
EDC Models (Sheet 2 of 2)
EDC No Heat
continued.
Will Not Heat
Is there voltage to the
output side of the stove
limit?
YES
Is there voltage to
terminal "2" of the ICM
board?
YES
Is there voltage at
terminal "1" of ICM
board?
YES
Is there voltage across
the coils of the gas
valve?
YES
NO
NO
NO
NO
Replace the stove
limit.
Correct wiring
between terminal
"2" of ICM board
and stove limit.
Replace ICM board.
Correct wiring
between gas valve
and ICM board.
NO
YES
Unit operational. Is there a flame?
70172201
Is there gas flow
through the gas valve?
YES
Does the igniter spark?
YES
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
NO
NO
Replace gas valve
coils or complete
gas valve.
Replace high
voltage ignition
cable or igniter.
T033D
T033D
55
Page 51
Will Not Heat
Gas
Manual Timer (Sheet 1 of 2)
NOTE: The following tests are conducted with
the Heat Timer in the "ON" position with the
machine running and calling for heat. Voltage
checks are referenced to transformer neutral.
Is there voltage across
terminals "1" & "6" of
the Temp Control Bd?
YES
YES
Is there voltage across
terminals "5" & "6" of
the Temp Control Bd?
NO
Is the thermistor
shorted or open?
NO
NO
YES
Single and stacked units with and without time
Replace thermistor.
delayboards.
YES
Is there voltage at Air
Flow Switch (AFS)
"N.C." terminal to
transformer neutral?
YES
Is there voltage at
terminal "6" on CR1 to
transformer neutral?
YES
Is there voltage from
terminal "4" on CR1 to
transformer neutral?
YES
Is unit equipped with
time delay board?
Replace inoperative
NO
switch or correct air
flow vane operation.
Correct wiring
NO
between A.F.S. and
terminal "6" on CR1.
NO
Replace CR1.
Is the temperature
selection switch
shorted or open?
Temperature
Control Board.
CONTINUED
ON NEXT
PAGE
NO
Replace the
YES
Replace selection
switch.
Is there
voltage to
terminal 3 of
fan motor?
YES
Is there voltage
across terminal
3 & 5 of fan
motor?
NO
Correct wiring
between motor
terminal 5 and
Temp Control Board
terminal 1.
Correct wiring
NO
between fan motor
terminal 3 and CR1
terminal 4.
YES
Replace fan motor.
NO
Is there voltage from
terminal "6" on CR2 to
transformer neutral?
YES
Is there voltage from
terminal "4" on CR2 to
transformer neutral?
YES
Correct wiring
between CR2
terminal "4" &
terminal "1" on
Temp Control
Board.
Correct wiring
NO
between terminal "6"
on CR2 to terminal
NO
Replace CR2.
"4" on CR1.
T044D
T044D
56
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70172201
Page 52
Gas
Manual Timer (Sheet 2 of 2)
NO HEAT CONTINUED
Note: Voltage checks are referenced to
transformer neutral.
Will Not Heat
Is there voltage to the
input side of the
Cabinet Limit?
YES
Is there voltage to the
output side of the
Cabinet Limit?
YES
Is there voltage to the
input side of the Stove
Limit?
YES
Is there voltage to the
output side of the Stove
Limit?
NO
NO
NO
NO
Correct wiring
between Cabinet
Limit and Temp
Control Board.
Replace the Cabinet
Limit.
Correct wiring
between Stove limit
and Cabinet Limit.
Replace the Stove
Limit.
NO
Is there voltage across
the coils of the gas
valve?
YES
Is there gas flow
through the gas valve?
YES
Does the igniter spark?
YES
Is there a flame?
NO
NO
NO
Correct wiring
between gas valve
and ICM board.
Replace gas valve
or gas valve coils.
Replace high
voltage cable or
igniter.
YES
Is there voltage across
terminals "2" & "3" of
ICM board?
YES
Is there voltage across
terminals "1" & "3" of
the ICM board?
YES
NO
NO
Correct wiring
betwee ICM board
and Stove limit.
Replace ICM board
YES
UNIT OPERATIONAL
T045D
T045D
70172201
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
57
Page 53
Will Not Heat
Gas
Rotary Coin Drop (Sheet 1 of 2)
Single & Stacked
Tumblers with
and without time delay.
YES
Is there voltage across
terminals "1" & "6" of
the Temp Control Bd?
YES
Is there voltage across
terminals "5" & "6" of
the Temp Control Bd?
NO
Is the thermistor
shorted or open?
NO
Is temperature
selection switch
shorted or open?
NO
Replace the
Temperature
Control Board.
Is there voltage on
terminal "3" of fan motor
to transformer
neutral?
YES
NO
YES
YES
NO
Replace thermistor.
Replace selection
switch.
Correct wiring
between terminal
"3" of fan motor
and "N.C." terminal
on switch "B".
YES
Is there voltage at Air
Flow Switch "N.C."
terminal to transformer
neutral?
YES
Is there voltage at
COM on Switch "B" to
transformer neutral?
YES
Is there voltage from
"N.C." on Switch "B" to
transformer neutral?
YES
Is the unit equipped
with a Time Delay
Board?
NO
Is there voltage from
terminal "6" on CR2 to
transformer neutral?
YES
Replace inoperative
NO
switch or correct air
flow vane operation.
Correct wiring
NO
between air flow
switch and COM on
NO
Replace Switch "B".
Correct wiring
NO
between terminal "6"
on CR2 to terminal
"N.C." on Switch "B".
Switch "B".
58
CONTINUED
ON NEXT
PAGE
With fan motor
running is there voltage
from terminal "5" to
transformer
neutral?
YES
Is there voltage on
terminal "1" of Temp
Board to transformer
neutral?
YES
Power supply to
Temp Control
Board is good.
NO
Replace Fan Motor.
Correct wiring
between terminal
NO
"1" of Temp Board
to terminal "5"
of fan motor.
Is there voltage from
terminal "4" on CR2 to
transformer neutral?
YES
Correct wiring
between terminal
"4" on CR2 &
terminal "1" on
Temp Control
Board.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
NO
Replace CR2.
T090D
T090D
70172201
Page 54
Gas
Rotary Coin Drop (Sheet 2 of 2)
NO HEAT CONTINUED
Note: Voltage checks are referenced to
transformer neutral.
Will Not Heat
Is there voltage to the
input side of the
Cabinet Limit?
YES
Is there voltage to the
output side of the
Cabinet Limit?
YES
Is there voltage to the
input side of the Stove
Limit?
YES
Is there voltage to the
output side of the Stove
Limit?
NO
NO
NO
NO
Correct wiring
between Cabinet
Limit and Temp
Control Board.
Replace the
Cabinet Limit.
Correct wiring
between Stove limit
and Cabinet Limit.
Replace the Stove
Limit.
Is there voltage across
through the gas valve?
Does the igniter spark?
NO
the coils of the gas
valve?
YES
Is there gas flow
YES
YES
Is there a flame?
NO
NO
NO
Correct wiring
between gas valve
and ICM Board.
Replace gas valve
coils or complete
gas valve.
Replace high
voltage ignition
cable or igniter.
YES
Is there voltage across
terminals "2" & "3" of
the ICM Board?
YES
Is there voltage across
terminals "1" & "3" of
the ICM Board?
YES
NO
NO
Correct wiring
between ICM
board and Stove
Limit or neutral.
Replace the ICM
Board.
YES
UNIT
OPERATIONAL
T091D
T091D
70172201
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
59
Page 55
Will Not Heat
Steam
EDC Models (Sheet 1 of 2)
Note: Tests are conducted with unit running
and calling for heat.
All voltage checks are referenced to
transformer neutral.
Single and Stacked
units.
Is there voltage on
“ FS-2” of EDC control?
Is there voltage
on “ FS-1” of
EDC control?
YES
Is there voltage on
COM of Airflow
switch?
Is there voltage across
COM & “ N.C.” terminal
of Airflow switch?
YES
YES
NO
Replace
thermistor.
NO
Is the
thermistor
operational?
NO
YES
Correct wiring
between “ FS-2” and
COM of lint drawer.
Replace EDC
control.
NO
YES
Correct wiring
between COM of
Airflow switch and
“ FS-1” of EDC
control.
Check for proper
function of Airflow
switch and replace if
necessary.
Is there voltage on
terminal “3” of fan
motor centrifugal
switch?
YES
Is there voltage across
terminals “3” & “5” of
fan motor centrifugal
switch?
NO
Is there voltage to the
input side of the
cabinet limit?
YES
Is there voltage across
cabinet limit?
NO
YES
NO
YES
Correct wiring
between terminal “3”
of fan motor
centrifugal switch
and terminal “4” of
motor control relay.
Replace fan motor.
Correct wiring
between cabinet
limit and terminal “5”
of fan motor
centrifugal switch.
Replace cabinet
limit.
60
NO
Is there voltage on
terminal “7” of motor
control relay?
YES
Is there voltage across
terminals “7” & “4” of
motor control relay?
NO
NO
Correct wiring
NO
YES
between terminal 7
on motor control
relay and N.C.
terminal on Airflow
switch.
Replace motor
control relay.
Is there voltage to the
input side of the stove
limit?
YES
Continued on next
page.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
NO
Correct wiring
between stove limit
and cabinet limit.
T096D
T096D
70172201
Page 56
Steam
EDC Models (Sheet 2 of 2)
Will Not Heat
Is there voltage to the
output side of the stove
limit?
YES
Is there voltage across
steam valve coil?
YES
Does steam valve
operate properly?
YES
NO
NO
NO
Replace the stove
limit.
Correct wiring to
steam valve coil.
Repair or replace
steam valve.
70172201
Is heat produced?
YES
Unit operational.
NO
Check for proper
steam supply.
Correct if necessary.
T097D
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
T097D
61
Page 57
Will Not Heat
Steam
Manual Timer (Sheet 1 of 2)
NOTE: The following tests are conducted with
the Heat Timer in the "ON" position with the
machine running and calling for heat. Voltage
checks are referenced to transformer neutral.
Is there voltage across
terminals "1" & "6" of
the Temp Control Bd?
YES
YES
Is there voltage across
terminals "5" & "6" of
the Temp Control Bd?
NO
Is the thermistor
shorted or open?
NO
NO
YES
Single and stacked units with and without time
delayboards, manual timers.
Replace thermistor.
YES
Is there voltage at Air
Flow Switch "N.C."
terminal to transformer
neutral?
YES
Is there voltage at
terminal "6" on CR1 to
transformer neutral?
YES
Is there voltage from
terminal "4" on CR1 to
transformer neutral?
YES
Is unit equipped with
time delay board?
Adjust the Air Flow
NO
Switch or replace if
NO
between A.F.S. and
terminal "6" on CR1.
NO
inoperative.
Correct wiring
Replace CR1.
Is temperature
selection switch
shorted or open?
Temperature
Control Board.
CONTINUED
ON NEXT
PAGE
NO
Replace the
YES
Replace selection
Is there
voltage to
terminal "3" of
fan motor?
YES
Is there voltage
across terminal
"3" & "5" of fan
motor?
NO
Correct wiring
between motor
terminal "5" and
Temp Control
Board terminal "1".
switch.
NO
Correct wiring
between fan motor
terminal "3" and
CR1 terminal "4".
YES
Replace fan motor.
NO
Is there voltage from
terminal "6" on CR2 to
transformer neutral?
YES
Is there voltage from
terminal "4" on CR2 to
transformer neutral?
YES
Correct wiring
between CR2
terminal "4" &
terminal "1" on
Temp Control
Board.
Correct wiring
NO
between terminal "6"
on CR2 to terminal
NO
Replace CR2.
"4" on CR1.
T019D
T019D
62
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70172201
Page 58
Steam
Manual Timer (Sheet 2 of 2)
NO HEAT CONTINUED
Note: Voltage checks are referenced to
transformer neutral.
Will Not Heat
Is there voltage to the
input side of the
Cabinet Limit?
YES
Is there voltage to the
output side of the
Cabinet Limit?
YES
Is there voltage to the
input side of the Stove
Limit?
YES
Is there voltage to the
output side of the Stove
Limit?
NO
NO
NO
NO
Correct wiring
between Cabinet
Limit and Temp
Control Board.
Replace the Cabinet
Limit.
Correct wiring
between Stove limit
and Cabinet Limit.
Replace the Stove
Limit.
Is heat produced?
YES
UNIT OPERATIONAL
Check for proper
NO
steam supply.
Correct if necessary.
YES
Is there voltage across
the coil of the steam
valve?
YES
Do the steam valves
operate properly?
YES
NO
NO
Correct wiring to
the steam valve.
Replace steam
valve.
T020D
T020D
70172201
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
63
Page 59
Will Not Heat
Steam
OPL Microprocessor (Sheet 1 of 3)
Testing conducted with unit
running and calling for heat.
Reference voltage to
transformer neutral
Is there votlage at
terminal "5" on OPL
Micro?
terminal "3".
YES
Continued on next
page column 2.
Is there voltage across
terminals "2" & "3" of
transformer
secondary?
NO
Replace
transformer.
NO
Is the thermister
operating properly?
YES
Reference voltage to
supply neutral.
Is power supplied to
unit?
YES
Is there voltage to input
of primary fuse(s)?
YES
Is there voltage to
output of primary
fuse(s)?
NO
NO
NO
NO
Replace thermister.
Connect supply
and run unit.
Correct wiring
between primary
fuse and supply.
Change primary
fuse.
YES
Note: Reference voltage to
transformer secondary neutral
Is there voltage to input
of secondary fuse?
YES
Is there voltage to
output of secondary
fuse?
YES
Is there voltage to
"N.O" terminal of door
switch?
YES
With door closed is
there voltage to "COM"
of door switch?
terminal "3".
NO
NO
NO
NO
Correct wiring
between secondary
fuse and
transformer.
Replace secondary
fuse.
Correct wiring
between "N.O."
terminal of door
switch and
secondary fuse.
Check for proper
operation, replace
door switch if
necessary.
64
YES
Is there voltage across
terminals "1" & "2" on
primary of
transformer?
YES
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
NO
between transformer
Correct wiring
and primary fuse.
YES
Is there voltage to
"N.O." of lint panel
switch?
YES
Continued on next
page column 1.
NO
Correct wiring
between "N.O." of
lint panel switch
and "COM" of door
switch.
T003D
T003D
70172201
Page 60
Steam
OPL Microprocessor (Sheet 2 of 3)
NO HEAT
Column 1
Column 2
The following tests are
conducted with the unit running
and calling for heat.
Will Not Heat
Is there voltage to
"COM" of lint panel
switch with lint panel
closed?
YES
Is there voltage at
terminal "8" of OPL
Micro?
YES
Is there voltage to
terminal "13" of OPL
Micro?
YES
Is there voltage at
terminal "6" of OPL
Micro?
YES
Replace OPL Micro.
NO
NO
NO
NO
Check for proper
operation and
replace lint panel
switch if necessary.
Correct wiring
between terminal
"8" of OPL Micro
and "COM" of lint
panel switch.
Replace OPL Micro.
Correct wiring
between terminal
"6" & "13" on OPL
Micro.
Three phase
Is there voltage at
"COM" of air flow
switch?
YES
Is there voltage at
"N.C." terminal of air
flow switch?
YES
Is the unit supplied with
single phase or three
phase power?
Single phase
Is there voltage at
terminal "7" of motor
control relay ?
YES
NO
NO
replace if necessary.
NO
"7" of motor control
relay and "N.C." of
Correct wiring
between "COM" &
OPL Micro.
Check for proper
oprerationand
Correct wiring
between terminal
air flow switch.
Is there voltage to
terminal 14 on motor
control relay?
YES
Is there votlage to
terminal 13 of motor
control relay?
NO
Replace motor
control relay.
between terminal 14
NO
YES
Correct wiring
on motor control
relay and N.C.
terminal of air flow
switch.
Is there voltage at
terminal "4" of motor
control relay?
YES
Is there voltage at
terminal "3" of fan
motor centrifugal
switch?
YES
Is there voltage at
terminal "5" of fan
motor centrifugal
switch?
YES
Continued on next
page.
NO
NO
NO
Replace motor
control relay.
Correct wiring
between fan motor
centrifugal switch
and motor control
relay.
Replace fan motor.
T004D
T004D
70172201
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
65
Page 61
Will Not Heat
Steam
OPL Microprocessor (Sheet 3 of 3)
Continued from column 2 of
previous page.
Is there voltage to the
input of the cabinet
limit?
YES
Is there voltage to
output of cabinet limit?
YES
Is there voltage to input
of stove limit?
YES
Is there voltage to the
output side of the stove
limit?
NO
NO
NO
NO
Correct wiring
between cabinet
limit and terminal "5"
of fan motor
centrifugal switch.
Replace cabinet
limit.
Correct wiring
between stove limit
and cabinet limit.
Replace stove limit.
Is heat produced?
YES
UNIT
OPERATIONAL.
NO
Check for proper
steam supply.
Correct if necessary.
66
YES
Is there voltage across
steam valve coil?
YES
Does the steam valve
operate properly?
YES
NO
NO
Correct wiring to
steam valve coil.
Replace steam
valve.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
T005D
T005D
70172201
Page 62
Steam
Rotary Coin Drop (Sheet 1 of 2)
Single & Stacked
Tumblers with
and without time delay.
Will Not Heat
Is there voltage across
terminals "1" & "6" of
YES
Is there voltage across
terminals "5" & "6" of
terminal "3" of fan motor to
transformer neutral?
the Temp Control
Board?
YES
the Temp Control
Board?
NO
Is the thermistor
shorted or open?
NO
Is temerature
selection switch
shorted or open?
NO
Replace the
Temperature
Control Board.
Is there voltage on
YES
NO
YES
Replace thermistor.
YES
NO
Replace selection
switch.
Correct wiring
between terminal
"3" of fan motor
and N.C. terminal
on switch B.
YES
Is there voltage at Air
Flow Switch "N.C."
terminal to transformer
neutral?
YES
Is there voltage at
COM on Switch "B" to
transformer neutral?
YES
Is there voltage from
"N.C." on Switch "B" to
transformer neutral?
YES
Is the unit equipped
with a Time Delay
Board?
NO
Is there voltage from
terminal "6" on CR2 to
transformer neutral?
YES
Adjust the Air Flow
NO
Switch or replace if
Correct wiring
NO
between A.F.S. and
COM on Switch "B".
NO
Replace Switch "B".
NO
between terminal "6"
on CR2 to terminal
"N.C." on Switch "B".
inoperative.
Correct wiring
70172201
CONTINUED
ON NEXT
PAGE
With fan motor
running is there voltage
from terminal "5" to
transformer
neutral?
YES
Is there voltage on
terminal "1"of Temp
Board to transformer
neutral?
YES
Power supply to
Temp Control
Board is good.
NO
Replace Fan Motor.
Correct wiring
between terminal
NO
"1" of Temp Board
to terminal "5" of
fan motor.
Is there voltage from
terminal "4" on CR2 to
transformer neutral?
YES
Correct wiring
between terminal
"4" on CR2 &
terminal "1" on
Temp Control
Board.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
NO
Replace CR2.
T066D
T066D
67
Page 63
Will Not Heat
Steam
Rotary Coin Drop (Sheet 2 of 2)
NO HEAT CONTINUED
Note: Voltage checks are referenced to
transformer neutral.
Is there voltage to the
input side of the
Cabinet Limit?
YES
Is there voltage to the
output side of the
Cabinet Limit?
YES
Is there voltage to the
input side of the Stove
Limit?
YES
Is there voltage to the
output side of the Stove
Limit?
NO
NO
NO
NO
Correct wiring
between Cabinet
Limit and Temp
Control Board.
Replace the Cabinet
Limit.
Correct wiring
between Stove limit
and Cabinet Limit.
Replace the Stove
Limit.
Is heat produced?
YES
UNIT
OPERATIONAL
Check for proper
NO
steam supply.
Correct if necessary.
YES
Is there voltage across
coil of steam valve?
YES
Does the steam valve
operate properly?
YES
NO
NO
Correct wiring to
steam valve
Replace steam
valve.
T067D
T067D
68
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT