Preliminary Installation Information
Subject 200 Pound Tumble Dryer
Use With 70420801 Installation Manual
Model Identification
Gas Steam/Thermal Oil
200 Pound
DR200G2-BA200L
DR200G2-BA200N
DR200G2-BT200L
DR200G2-BT200N
DR200G2-BU200L
DR200G2-BU200N
CA200L
CA200N
CT200L
CT200N
CU200L
CU200N
HA200L
HA200N
HT200L
HT200N
HU200L
HU200N
IT200L
IT200N
SA200L
SA200N
ST200L
ST200N
SU200L
SU200N
UA200L
UA200N
UT200L
UT200N
UU200L
UU200N
DR200S2-BT200S
DR200S2-BT200T
DR200S2-BU200S
DR200S2-BU200T
CT200S
CT200T
CU200S
CU200T
HT200S
HT200T
HU200S
HU200T
IT200S
IT200T
ST200S
ST200T
SU200S
SU200T
UT200S
UT200T
UU200S
UU200T
Includes models with the following control suffixes:
R3 – reversing DX4 OPL RE – reversing OPL Micro RQ – reversing dual digital timer
RD – reversing DMP OPL RM – reversing OPL Micro RU – reversing UniLinc OPL
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Page 1 of 12
Part No. 70470101R1
April 2012

Specifications and Dimensions
Specifications 200 Pound
Noise level measured during operation at operator position of 3.3 feet
(1 meter) in front of machine and 5.2 feet (1.6 meters) from floor.
66 dBA
Cylinder Size: Inches (mm)
Cylinder Capacity dry weight: Pounds (kg)
Cylinder Motor Horsepower
Fan Motor Horsepower
Air Outlet Diameter: Inches (mm)
Maximum Static Back Pressure: W.C.I. (mbar)
Maximum Airflow: C.F.M (L/sec.)
Gas Models
Net Weight (approximate): Pounds (kg)
Gas Connection
Gas Burner Rating: Btu/hr. (Mj/hr.)
Steam Models
Net Weight (approximate): Pounds (kg)
Steam Conn ection
Steam Coil Rating at 100 psig :Boiler Horsepower (Btu/hr.)
(recommended operating pressure 80-100 psig)
50.75 x 50
(1289 x 1270)
200
(90.7)
0.75
3
12
(300)
0.3
(0.8)
2450
(1156)
1707
(774)
1 in. NPT
425,000
(448)
1807
(820)
3/4 in. NPT inlet
1 in. NPT outlet
18.8
(648,000)
Heating Element Rating:Kilowatts (kW)
N/A = Not Applicable
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Electric Models
N/A
Page 2 of 12

200 Pound Tumble Dryer
A
B
C
D
W
H
F
Y
X
V
TOP VIEW OF
EXHAUST
DUCT
E
G
I
Dimensions and Exhaust Outlet
Locations
Cabinet Dimensions
Models A B C D E F G H I
200L/N/S
32.1 in.
(815 mm)
35.6 in.
(904 mm)
58 in.
(1473 mm)
59.25 in.
(1505 mm)
76.68 in.
(1948 mm)
52.12 in.
(1324 mm)
53.12 in.
(1349 mm)
94 in.
(2388 mm)
Refer to Position and Level the Tumble Dryer to temporarily reduce the heights of these models.
Exhaust Outlet Dimensions and Locations
Models V W X Y
200L/N/S
67.19 in.
(1707 mm)
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
7.03 in.
(179 mm)
Page 3 of 12
(229 mm)
9 in.
TMB2363N
75.12 in.
(1908 mm)
7 in.
(178 mm)

Electric and Gas Connection
Locations for Gas Models
Models
Electrical Connection Gas Connection
ABCDDiameter
200L/N
21 in.
(533 mm)
81 in.
(2057 mm)
NOTE: These figures are approximate dimensions only.
13.7 in.
(348 mm)
77.4 in.
(1966 mm)
TMB2357N
1 in. NPT
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Page 4 of 12