(If this machine changes ownership, this manual must accompany machine.)
www.comlaundry.com
TMB1268C
Part No. 70420801R8EN
November 2011
Page 2
Page 3
Installation must conform with local codes or, in the absence of local codes, with:
• Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or
any other appliance.
• WHAT TO DO IF YOU SMELL GAS:
– Do not try to light any appliance.
– Do not touch any electrical switch; do not use any phone in your building.
– Clear the room, building or area of all occupants.
– Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s
instructions.
– If you cannot reach your gas supplier, call the fire department.
• Installation and service must be performed by a qualified installer, service agency or the gas
supplier.
W052
FOR YOUR SAFETY, the information in this manual must be followed to minimize the risk
of fire or explosion or to prevent property damage, personal injury or death.
W033
WARNING
In the U.S.A.
, installation must conform to the latest edition of the American National Standard Z223.1/
NFPA 54 “National Fuel Gas Code” and Standard ANSI/NFPA 70 “National Electric Code.”
In Canada
, installation must comply with Standards CAN/CSA-B149.1 or Natural Gas and Propane
Installation Code and CSA C22.1, latest edition, Canadian Electric Code, Part I.
In Australia and New Zealand
, installation must comply with the Gas Installations Standard AS/NZS 5601
Part 1: General Installations.
IMPORTANT: Information must be obtained from a local gas supplier on instructions to be followed if the
user smells gas. These instructions must be posted in a prominent location. Step-by-step instructions of the
above safety information must be posted in a prominent location near the tumble dryer for customer use.
The following information applies to the state of Massachusetts, USA.
• Installation of unit must be performed by a qualified installer.
• Install tumble dryer according to manufacturer’s instructions and local codes.
• DO NOT install a tumble dryer with flexible plastic venting materials. If flexible metal (foil
type) duct is installed, it must be of a specific type identified by the appliance manufacturer
as suitable for use with tumble dryer. Refer to section on connecting exhaust system.
Flexible venting materials are known to collapse, be easily crushed, and trap lint. These
conditions will obstruct tumble dryer airflow and increase the risk of fire.
W752R1
WARNING
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or
any other appliance.
W053
This appliance can only be installed by a Massachusetts licensed plumber or gas fitter.
This appliance must be installed with a 36 inch (91 cm) long flexible gas connector.
A "T-Handle" type gas shut-off valve must be installed in the gas supply line to this appliance.
This appliance must not be installed in a bedroom or bathroom.
All rights reserved. No part of the contents of this book may be reproduced or transmitted in any form or by any
means without the expressed written consent of the publisher.
If literature or replacement parts are required, contact
the source from which the machine was purchased or
contact Alliance Laundry Systems at (920) 748-3950
for the name and address of the nearest authorized
parts distributor.
DANGER – Indicates an imminently
hazardous situation that, if not avoided,
will cause severe personal injury or
death.
DANGER
WARNING – Indicates a hazardous
situation that, if not avoided, could cause
severe personal injury or death.
WARNING
CAUTION – Indicates a hazardous
situation that, if not avoided, may cause
minor or moderate personal injury or
property damage.
CAUTION
Failure to install, maintain, and/or operate
this machine according to manufacturer’s
instructions may result in conditions which
can produce serious injury, death and/or
property damage.
W051R1
WARNING
Precautionary statements (“DANGER,” “WARNING,”
and “CAUTION”), followed by specific instructions,
are found in this manual and on machine decals. These
precautions are intended for the personal safety of the
operator, user, servicer, and those maintaining the
machine.
NOTE: The WARNINGS and IMPORTANT
instructions appearing in this manual are not
meant to cover all possible conditions and
situations that may occur. It must be understood
that common sense, caution and carefulness are
factors which CANNOT be built into this tumble
dryer. These factors MUST BE supplied by the
person(s) installing, maintaining or operating the
tumble dryer.
Always contact your dealer, distributor, service agent
or the manufacturer on any problems or conditions you
do not understand.
Additional precautionary statements (“IMPORTANT”
and “NOTE”) are followed by specific instructions.
IMPORTANT: The word “IMPORTANT” is used
to inform the reader of specific procedures where
minor machine damage will occur if the procedure
is not followed.
NOTE: The word “NOTE” is used to communicate
installation, operation, maintenance or servicing
information that is important but not hazard
related.
Hazardous Voltage. Can cause shock, burn
or cause death. Allow machine power to
remain off for two minutes prior to working
in and around AC inverter drive.
W359
WARNING
Save These Instructions
Important Safety Instructions
1. Read all instructions before using the tumble
dryer.
2. Refer to the Grounding Instructions for the
proper grounding of the tumble dryer.
3. Do not dry articles that have been previously
cleaned in, washed in, soaked in, or spotted with
gasoline, dry cleaning solvents, other flammable
or explosive substances as they give off vapors
that could ignite or explode.
4. Do not allow children on or in the tumble dryer.
This appliance is not intended for use by young
children or infirm persons without supervision.
Young children should be supervised to ensure
that they do not play with the appliance.
5. Before the tumble dryer is removed from service
or discarded, remove the door to the drying
compartment and the door to the lint
compartment.
6. Do not reach into the tumble dryer if the cylinder
is revolving.
7. Do not install or store the tumble dryer where it
will be exposed to water and/or weather.
8. Do not tamper with the controls.
13. Keep area around the exhaust opening and
adjacent surrounding area free from the
accumulation of lint, dust and dirt.
14. The interior of the tumble dryer and the exhaust
duct should be cleaned periodically by qualified
service personnel.
15. If not installed, operated and maintained in
accordance with the manufacturer’s instructions
or if there is damage to or mishandling of this
product’s components, use of this product could
expose you to substances in the fuel or from fuel
combustion which can cause death or serious
illness and which are known to the State of
California to cause cancer, birth defects or other
reproductive harm.
16. Tumble dryer will not operate with the loading
door open. DO NOT bypass the door safety
switch to permit the tumble dryer to operate with
the door open. The cylinder will stop rotating
when the door is opened. Do not use the tumble
dryer if the cylinder does not stop rotating when
the door is opened or starts rotating without
pressing or turning the START mechanism.
Remove the tumble dryer from use and call for
service.
17. Tumble dryer will not operate with lint panel
open. DO NOT bypass lint panel safety switch to
permit tumble dryer to operate with the lint panel
open.
18. Do not put articles soiled with vegetable or
cooking oil in the tumble dryer, as these oils may
not be removed during washing. Due to the
remaining oil, the fabric may catch on fire by
itself.
9. Do not repair or replace any part of the tumble
dryer, or attempt any servicing unless specifically
recommended in the user-maintenance
instructions or in published user-repair
instructions that you understand and have the
skills to carry out.
10. Do not use fabric softeners or products to
eliminate static unless recommended by the
manufacturer of the fabric softener or product.
11. To reduce the risk of fire, DO NOT DRY plastics
or articles containing foam rubber or similarly
textured rubberlike materials.
19. To reduce the risk of fire, DO NOT put clothes
which have traces of any flammable substances
such as machine oil, flammable chemicals,
thinner, etc. or anything containing wax or
chemicals such as in mops and cleaning cloths, or
anything dry-cleaned at home with dry-cleaning
solvent in the tumble dryer.
20. Use the tumble dryer only for its intended
purpose, drying fabrics.
21. ALWAYS disconnect the electrical power to the
tumble dryer before servicing. Disconnect power
by shutting off appropriate breaker or fuse.
70420801 (EN)
Page 11
Safety Information
To reduce the risk of serious injury, install
lockable door(s) to prevent public access
to rear of tumble dryers.
W055R1
WARNING
22. Install this tumble dryer according to this
Installation Manual. All connections for
electrical power, grounding and gas supply must
comply with local codes and be made by licensed
personnel when required.
23. Remove laundry immediately after tumble dryer
stops.
24. Always read and follow manufacturer’s
instructions on packages of laundry and cleaning
aids. Heed all warnings or precautions. To reduce
the risk of poisoning or chemical burns, keep
them out of reach of children at all times
(preferably in a locked cabinet).
25. Do not tumble fiberglass curtains and draperies
unless the label says it can be done. If they are
dried, wipe out the cylinder with a damp cloth to
remove particles of fiberglass.
26. Always follow the fabric care instructions
supplied by the garment manufacturer.
27. Never operate the tumble dryer with any guards
and/or panels removed.
28. DO NOT operate the tumble dryer if it is
smoking, grinding, has missing or broken parts.
29. DO NOT bypass any safety devices.
30. Failure to install, maintain, and/or operate this
machine according to the manufacturer’s
instructions may result in conditions which can
produce bodily injury and/or property damage.
31. Solvent vapors from dry-cleaning machines
create acids when drawn through the heater of the
unit. These acids are corrosive to the tumble
dryer as well as to the laundry load being dried.
Be sure make-up air is free of solvent vapors.
Upon delivery, visually inspect the crate, carton and
parts for any visible shipping damage. If the crate,
carton or cover is damaged or signs of possible
damage are evident, have the carrier note the condition
on the shipping papers before the shipping receipt is
signed, or advise the carrier of the condition as soon as
it is discovered.
Remove the crate and protective cover as soon as
possible and check the items listed on the packing list.
Advise the carrier of any damaged or missing articles
as soon as possible. A written claim should be filed
with the carrier immediately if articles are damaged
or missing.
IMPORTANT: Warranty is void unless tumble
dryer is installed according to instructions in this
manual. Installation should comply with minimum
specifications and requirements detailed in this
manual and applicable local gas fitting regulations,
municipal building codes, water supply regulations,
electrical wiring regulations, and any other
relevant statutory regulations. Due to varied
requirements, applicable local codes should be
thoroughly understood and all pre-installation
work arranged for accordingly.
Materials Required (Obtain locally)
All Models
Gas Models
Steam Models
One Single Pole fused disconnect
switch or circuit breaker on 1 Phase
models.
Circuit breaker on 3 Phase models.
One gas shut-off valve for gas
service line to each tumble dryer.
One steam shut-off valve for steam
service line to be connected upstream
of solenoid steam valve.
Two steam shut-off valves for each
condensate return line.
Flexible steam hoses with a 125 psig
(pounds per square inch gauge)
(8.79 kg/sq. cm) working pressure
for connecting steam coils. Refer to
Figure 14 and Figure 15 or sizing
and connection configurations.
Three steam traps for steam coil
outlet to condensate return line.
Optional – Three vacuum breakers
for condensate return lines.
IMPORTANT: Keep tumble dryer area clear and
free from combustible materials, gasoline and other
flammable vapors and liquids.
Location Requirements
The tumble dryer must be installed on a level floor.
Floor covering materials such as carpeting or tile must
be removed.
To assure compliance, consult local building code
requirements. The tumble dryer must not be installed
or stored in area where it will be exposed to water and/
or weather.
IMPORTANT: DO NOT block the airflow at the
rear of the tumble dryer with laundry or other
articles. Doing so would prevent adequate air
supply to the combustion chamber of the tumble
dryer.
A typical tumble dryer enclosure is shown in Figure 1.
Note the minimum and maximum dimensions. Local
codes and ordinances must be complied with.
The tumble dryer may be moved with or without the
skid. To remove the skid, unscrew the four shipping
bolts, and discard them.
To fit a 170 pound tumble dryer (with shipping skid)
through an 8 foot (2.43 meters) high door, you must
remove the front access panel. The upper 3 inches
(76 mm) of the stove must also be removed on
170 pound gas tumble dryers. Removing the entire gas
or steam heater assembly and the shipping skid, will
reduce the height of the 120 pound tumble dryer to 70
inches (1778 mm), and the 170 pound tumble dryer to
75 inches (1905 mm).
Level the tumble dryer to within 0.125 inch (3 mm)
from front-to-rear (level on cylinder rib), and side-toside (level on top panel). Shim under corners to level
and stabilize unit. Tumble dryer must not rock.
Before Placing Tumble Dryer into
Service
1. Remove or open all panels and check accessible
bolts, nuts, screws, terminals and fittings for
tightness.
2. Check V-belt tension and adjust if necessary.
Refer to appropriate paragraphs in Adjustments
Section.
3. Replace all panels and guards.
4. Turn on electrical supply to tumble dryer.
5. Open supply valve for gas or steam heated
tumble dryers.
6. After performing the previous checks, start
the tumble dryer by pressing START (hold for
approximately 3 seconds). Release the start
button and open the loading door. The cylinder
should stop rotating within 7 seconds after the
door is opened.
7. Gas tumble dryers: Start the tumble dryer and
check the burner flame. Adjust the gas inlet
shutter as required. Refer to Adjustments section.
IMPORTANT: The Electronic Ignition system will
attempt to light the gas by sparking for the “trial
for ignition” period. If gas does not ignite within
this period, the ignition control will go into a safety
lockout and the valve will no longer open until the
control is reset. Refer to Tab le 1. It may be
necessary to restart several times to bleed air out of
gas lines. To reset, open and close loading door,
then start.
Reset
Lockout
Condition
By:
Press and
hold reset
button on
junction box
until light
goes out.
Open loading
door.
Location
CE and
Australia
All others
Prepurge
Time
(seconds)
1810
1-310
Table 1
Tri al fo r
Ignition
(seconds)
If lockout condition persists, check that the manual
gas shut-off valve is in the open position and that
the gas service is properly connected. If condition
still persists, remove tumble dryer from service.
8. Load the cylinder with a full load of clean rags
and run to remove oil or dirt from cylinder.
The tumble dryer must not be operated if
the airflow switch does not operate
properly. Faulty airflow switch operation
may cause an explosive gas mixture to
collect in the tumble dryer.
W072R1
WARNING
Required for CE Models Only
Once machine is installed, please be sure to complete
the following items:
Review and verify machine operation with
customer.
Leave all literature and a signed Declaration of
Conformity with customer.
9. Check the airflow switch operation by opening
the lint panel; be sure to remove shipping tape
from airflow switch prior to operation.
Temporarily tape down the lint panel safety
switch located behind the upper left corner of the
lint panel. The heating systems should shut off
when the lint panel is opened a maximum of
6 inches (152.4 mm). The airflow switch
operation may be affected by lack of make-up air
or an obstruction in the exhaust duct. These
should be checked; if there is a problem, contact
an authorized service person.
10. Wipe out the cylinder using an all-purpose
cleaner or detergent and water solution.
If tumble dryer does not meet any of the listed
requirements, remove tumble dryer from service.
Refer to Removing Tumble Dryer from Service
section.
Review machine warranty information with
customer.
Apply warning sticker on front panel of machine,
in language appropriate to country of sale
(included in literature packet).
To reduce the risk of electric shock, fire,
explosion, serious injury or death:
• Disconnect electric power to the tumble
dryer before servicing.
• Close gas shut-off valve to gas tumble
dryer before servicing.
• Close steam valve to steam tumble
dryer before servicing.
• Never start the tumble dryer with any
guards/panels removed.
• Whenever ground wires are removed
during servicing, these ground wires
must be reconnected to ensure that the
tumble dryer is properly grounded.
W002R1
Installing CE Gas Drying Tumble
Dryers
General Information
This information is to be used when installing gas
tumble dryers in countries, and/or on gases, different
than the machine’s factory configuration. Tumble
dryers are supplied from the factory for operation on
Natural Gas 1000 Btu/cu. ft. (8914 kcal/m
Gas 2500 Btu/cu. ft. (22,250 kcal/m
of GB/IE/PT/ES/IT/GR/LU/CH. To install machines
in any other country or on any other gas requires some
level of modification.
3
3
), or L.P.
) in the countries
Models are built in two different configurations:
Regulated Natural Gas – Injector is sized for
Natural Gas, second family, group H (E) at
20 mbar inlet pressure. Regulator/governor is
operational. Gas valve CAN be field converted to
a non-regulating type.
Unregulated L.P. (Liquefied Petroleum) Gas –
Injector is sized for L.P. Gas, third family, group
3+ at 28.37 mbar inlet pressure. Regulator/
governor is blocked open. Gas valve CAN be
field-converted to a regulating type.
Serial plates supplied from the factory are configured
for the countries of GB/IE/PT/ES/IT/GR/LU/CH.
These instructions pertain to the situations when the
country of use or gas supply is different than that on
the serial plate.
Tab l e 2 describes the different gases that are available
in different CE countries, and how the machines need
to be configured to operate with those gases. In the
CE, there are Natural Gas configurations that do not
allow for machine regulation, and L.P. Gas
configurations that must be regulated. For L.P. Gas,
third family B/P at 50 mbar, order Regulated Natural
Gas machines and convert according to Tab l e 2 .
** For L.P. Gas, Group B/P with 50 mbar supply pressure,
convert using Natural Gas model and appropriate burner
orifices.
21
Page 24
Installation
WARNING
When converting the tumble dryer to a
different gas or pressure, first verify that
the supply inlet pressure is equipped with
a pressure regulator (located ahead of the
tumble dryer) that will maintain the gas
supply at the inlet pressure specified.
W430R1
SPECIFIED
LOCAL INLET
PRESSURE
2
1
Basic Configuration
1. Determine the necessary conversion operations
to convert from the factory-supplied
configuration to the desired configuration.
2. Perform the conversions required so the machine
is properly configured for the desired country and
gas (refer to Specific Conversion Procedures
section):
How to Convert Gas Valve from Regulated to
Unregulated
NOTE: Conversion from regulated to unregulated
is only needed when regulated tumble dryers were
ordered, but unregulated tumble dryers were
needed.
How to Change Burner Orifice Size
How to Adjust Gas Valve Governor/Regulator
3. If applicable, peel off the appropriate country
sticker (included with machine) and apply it to
the serial plate over the existing country
information.
4. If applicable, peel off the appropriate conversion
sticker (included with machine) and apply it to
the serial plate over the “ADJUSTED FOR
______ GAS: ______” information.
How to Convert Gas Valve from Regulated to
Unregulated
NOTE: Conversion from regulated to unregulated
is only needed when regulated tumble dryers were
ordered, but unregulated tumble dryers were
needed.
Refer to Table 2.
1. Disconnect electrical power from tumble dryer.
Close gas shut-off valve to tumble dryer. Refer to
Figure 2.
2. Follow instructions in Conversion Kit.
3. Change burner orifice size as required by the
appropriate table according to How to Change Burner Orifice Size.
4. Commission tumble dryer for use.
How to Change Burner Orifice Size
1. Disconnect electrical power from tumble dryer.
Close gas shut-off valve to tumble dryer. Refer to
Figure 2.
2. Remove gas valve:
Remove the burner orifice(s) from the spud
holder. When converting from Natural Gas to
L.P. Gas, the left-most burner and orifice (viewed
from front) must be removed. In place of the
removed orifice, a blank orifice (Part No.
M400995) and a Burner Opening Cover (Part
No. M413099) must be installed.
3. Install the new, correct orifices. Refer to
Figure 4. Torque each to 9-10 Nm.
4. Reinstall spud holder assembly to gas valve,
making certain orifice(s) are in line with burner
tube opening.
5. Commission tumble dryer for use.
NOTE: Blank burner orifices are available as
Part No. M400995.
1. Check gas burner orifice (manifold) pressure as
follows. Refer to Figure 3.
2. Remove screw plug from inside pressure tap.
3. Connect a “U”-tube manometer (or similar
pressure gauge) to the orifice (manifold) pressure
tap.
4. Start tumble dryer and note pressure once flame
is burning. Remove regulator cap and adjust
regulator screw until the burner orifice pressure
per applicable table is achieved. Replace
regulator cap.
A drying tumble dryer produces
combustible lint. To reduce the risk of fire,
the tumble dryer must be exhausted to the
outdoors.
W057R1
To reduce the risk of fire and accumulation
of combustible gases, DO NOT exhaust
tumbler air into a window well, gas vent,
chimney or enclosed, unventilated area
such as an attic, ceiling, crawl space under
a building, or concealed space of a
building.
W506
WARNING
WARNING
To reduce the risk of fire due to increased
static pressure, we do not recommend
installation of in-line secondary lint filters
or lint collectors. If secondary systems
are mandated, frequently clean the
system to assure safe operation.
W749
Layout
Wherever possible, install tumble dryers along an
outside wall, where duct length can be kept to a
minimum and makeup air can be easily accessed.
Construction must not block the airflow at the top rear
of the tumble dryer. Doing so would prevent adequate
air supply to the tumble dryer combustion chamber.
Make-up air openings with louvers will restrict air
flow. The opening must be increased to compensate
for area taken up by louvers.
Make-up air openings in rooms containing tumble
dryer(s) and/or gas fired hot water heater or other
gravity vented appliances must be increased
sufficiently to prevent downdrafts in any of the vents
when all tumble dryers are in operation. Do not locate
gravity vented appliances between tumble dryer(s) and
make-up air openings. If it is necessary to duct makeup air to tumble dryer(s), increase area of duct work by
25% to compensate for any restriction in air
movement.
Venting
Make-Up Air
A tumble dryer is forced air exhausted and requires
provisions for make-up air to replace air exhausted
by tumble dryer. Refer to Ta bl e 3 .
IMPORTANT: Do not obstruct flow of combustion
and ventilation air.
IMPORTANT: Installing in-line filters or lint
collectors will cause increased static pressure.
Failure to maintain the secondary lint system will
decrease tumble dryer efficiency and may void
machine warranty.
For maximum efficiency and minimum lint
accumulation, tumble dryer must be exhausted to the
outdoors by the shortest possible route.
Proper sized exhaust ducts are essential for proper
operation. All elbows should be sweep type. Exhaust
ducts must be assembled so the interior surfaces are
smooth, so the joints do not permit the accumulation
of lint. DO NOT use plastic, thin foil or Type B
flexible ducts – rigid metal ducts are recommended.
Use exhaust ducts made of sheet metal or other
noncombustible material. Use of duct tape or poprivets on all seams and joints is recommended, if
allowed by local codes.
Verify that old ducts are thoroughly cleaned before
installing new tumble dryer(s).
25
Page 28
Exhaust Requirements
Improperly sized or assembled ductwork
causes excess back pressure which
results in slow drying, lint collecting in the
duct, lint blowing back into the room, and
increased fire hazard.
W355
WARNING
T496I
2
1
CUT
CUT
NOTE: Exhaust ducts must be constructed of sheet
metal or other noncombustible material. Such
ducts must be equivalent in strength and corrosion
resistance to ducts made of galvanized sheet steel
not less than 0.0195 inch (0.495 mm) thick.
Where the exhaust duct pierces a combustible wall or
ceiling, the opening must be sized per local codes. The
space around the duct shall be sealed with
noncombustible material.
NOTE: For best performance, provide an
individual exhaust duct for each tumble dryer. Do
not install a hot water heater in a room containing
tumble dryers. It is better to have the water heater
in a separate room with a separate air inlet.
Alternate Venting for 120 Pound tumble dryers
The 120 pound tumble dryer is equipped from the
factory to exhaust from the top; however, it may be
converted to exhaust out the rear by doing the
following (refer to Specifications and Dimensions
section):
1. Remove belt guard cover.
2. Remove 10 inch (254 mm) diameter elbow and
vertical duct.
3. Cut out shape from belt guard cover. Refer to
Figure 5.
4. Screw octagonal piece over 10 inch (254 mm)
diameter opening in top of belt guard.
5. Attach new exhaust duct to exhaust thimble on
rear panel, following all requirements in this
section.
For maximum efficiency and performance, it is
preferred to exhaust tumble dryer(s) individually to
the outdoors.
IMPORTANT: At no point may the cross sectional
area of installed venting be less than the cross
sectional area of the exhaust outlet of the tumble
dryer.
The exhaust duct must be designed so the static back
pressure measured 12 inches (305 mm) from the
exhaust outlet does not exceed the maximum
allowable pressure specified on the installation sticker
on the rear of the tumble dryer.
NOTE: Static back pressure must be measured
with the tumble dryer running.
The maximum allowable length of venting of the same
diameter as the exhaust thimble is 14 feet (4.3 meters)
and two 90° elbows or equivalent. If the equivalent
length of a duct required for an installation exceeds the
maximum allowable equivalent length, the diameter of
a round duct must be increased by 10% for each
additional 20 feet (6.1 meters). Cross section area of a
rectangular duct must be increased by 20% for each
additional 20 feet (6.1 meters). Refer to Tabl e 4 to
determine equivalent venting:
NOTE: The maximum length of a flexible metal
duct must not exceed 7.87 ft. (2.4 m) as required to
meet UL2158, claus 7.3.2A.
Manifold Venting
While it is preferable to exhaust tumble dryers
individually to the outdoors, a main collector duct may
be used if it is sized according to Figure 8. This
illustration indicates minimum diameters, and should
be increased if collector length exceeds 20 feet (6.1
meters). Manifold duct may be rectangular in cross
section, as long as area is not reduced. Provisions
should be made for lint removal and cleaning of duct.
Manifold duct must be tapered, as shown in Figure 6.
Individual tumble dryer ducts must enter manifold
duct at a 45° angle in the direction if airflow.
NOTE: Never connect a tumble dryer duct at a 90°
angle to a collector duct. Refer to Figure 6. Doing
so will cause excessive back pressure, resulting in
poor performance. Never connect two tumble
dryer exhaust ducts directly across from each other
at the point of entry to manifold duct.
Duct Diameter
10 in. (254 mm)
12 in. (305 mm)
14 in. (356 mm)
16 in. (406 mm)
18 in. (457 mm)
Equivalent Length (ft.) = 1.17 x Duct Diameter (in.)
Example: A 12 inch (305 mm) diameter duct’s
equivalent length of 14 feet (4.3 meters) of duct and two
90° elbows is:
Equivalent Length: = 14 ft. (4.3 m) + (2) 90° elbows
One 90° elbow = 11.6 ft. (3.5 m)
One 90° elbow = 14 ft. (4.3 m)
One 90° elbow = 16 ft. (4.9 m)
One 90° elbow = 18.7 ft. (5.7 m)
One 90° elbow = 21 ft. (6.4 m)
Equivalent Length
of Rigid Straight Duct
Table 4
= 14 ft. (4.3 m) + 14 ft. (4.3 m)
+ 14 ft. (4.3 m)
= 42 ft. (12.8 m)
With the tumble dryer in operation, airflow at any
point in the duct should be at least 1200 feet per
minute (366 meters per minute) to ensure that lint
remains airborne. If 1200 feet per minute (366 meters
per minute) cannot be maintained, schedule monthly
inspections and cleaning of the ductwork.
T438I
Figure 6
Exhaust system must be designed so static back
pressure measured 12 inches (305 mm) from exhaust
thimble does not exceed maximum allowable pressure
specified on installation sticker on rear of tumble
dryer. This must be measured with all tumble dryers
running that are vented into collector.
With the tumble dryer in operation, airflow at any
point in the duct should be at least 1200 feet per
minute (366 meters per minute) to ensure that lint
remains airborne. If 1200 feet per minute (366 meters
per minute) cannot be maintained, schedule monthly
inspections and cleaning of the ductwork.
To reduce the risk of fire or explosion, DO
NOT CONNECT THE GAS LINE TO THE
TUMBLE DRYER IF THE GAS SERVICE IS
NOT THE SAME AS THAT SPECIFIED ON
THE TUMBLE DRYER SERIAL PLATE! It
will first be necessary to convert the gas
burner orifice and gas valve. Appropriate
conversion kits are available.
W060R1
WARNING
The tumbler and its individual shut-off
valve must be disconnected from the gas
supply piping system during any
pressure testing of that system at test
pressures in excess of 0.5 psig (3.45 kPa).
The tumbler must be isolated from the
gas supply piping system by closing its
individual manual shut-off valve during
any pressure testing of the gas supply
piping system at test pressure equal to or
less than 0.5 psig (3.45 kPa).
W061R2
WARNING
To reduce the risk of fire or explosion, if
the tumble dryer is to be connected to
Liquefied Petroleum (L.P.) gas, a vent to
the outdoors must be provided in the
room where the tumble dryer is installed.
W062R1
IMPORTANT: Any product revisions or conversions
must be made by the Manufacturer’s Authorized
Dealers, Distributors or local service personnel.
The following must be furnished and installed by the
customer for the gas service line to each tumble dryer.
Refer to Figure 10.
Sediment traps
Shut-off valves
Supply pressure taps
It is important that equal pressure be maintained at all
tumble dryer gas connections. This can be done by
installing a one inch (25 mm) pipe gas loop. Refer to
Figure 11.
IMPORTANT: The installation must comply with
local codes or, in the absence of local codes:
with the latest edition of the “National Fuel
Gas Code,” ANSI Z223.1/NFPA 54 in the
U.S.A.
with CAN/CSA-B149.1 Natural Gas and
Propane Installation Code in Canada
and Gas Installations Standard AS/NZS 5601
Part 1: General Installations in Australia and
New Zealand
Obtain specific gas service pipe size from the gas
supplier. Refer to Tab l e 7 for general pipe size.
NATURAL GAS recommended line pressure is 6.5
water column inches (1.62 kPa), with no less than 5
water column inches (1.24 kPa) and no more than 10.5
water column inches (2.61 kPa), with all gas
appliances running (tumble dryers, water heaters,
space heaters, furnace, etc.). An in-line pressure
regulator may be required if the line pressure exceeds
10.5 water column inches (2.61 kPa) with all gas
appliances running.
LIQUID PETROLEUM GAS (L.P.) line pressure must
be maintained at 11 water column inches (2.74 kPa),
with no less than 10 water column inches (2.49 kPa)
and no more than 13 water column inches (3.23kPa),
with all gas appliances running (tumble dryers, water
heaters, space heaters, furnace, etc.).
For converting Non-CE Models from Natural Gas to
L.P. Gas:
120 Pound Models - M4973P3
170 Pound Models - M4974P3
CE GASES refers to Installing CE Gas Drying Tumble Dryers section, the above data does not apply
to the CE.
31
Page 34
Gas Requirements
1
2
3
4
5
6
WARNING
Check all pipe connections, internal and
external, for gas leaks using a noncorrosive leak detection fluid. To reduce
the risk of explosion or fire, DO NOT USE
AN OPEN FLAME TO CHECK FOR GAS
LEAKS! Gas connections should be
checked twice a year for leakage.
W635
1Gas Line to tumble dryer Controls
2Gas Supply Piping System
3Gas “T” Fitting
46 in. (152 mm) Minimum Gas Pipe
5Gas Pipe Cap
6Sediment Trap
TMB2317N
Figure 10
Turn on gas and check all pipe connections (internal
and external) for gas leaks with a non-corrosive leak
detection fluid. Purge air in gas service line by
operating the tumble dryer in the drying mode. If
burner does not light and unit goes into lockout, open
and close the door and restart. Repeat these steps until
burner ignites. Use pipe compound, resistant to
2Gas Water Heaters (400,000 Btu/hr. each)9Main Regulator
3Gas Space Heaters (70,000 Btu/hr. each)10Gas Meter
4Sediment Traps, Supply Pressure Taps and
Shut-Off Valves. Refer to Figure 10.
619ft.(5.8 m)'
7Minimum Pipe Size to Tumble dryer is 0.75 in. for
120 Pound Gas, 1 in. for 170 Pound Gas
11Pressure Regulator (If required)
12120 Pound tumble dryers (270,000 Btu/hr. each)
170 Pound tumble dryers (395,000 Btu/hr. each)51 in. (25.4 mm) Gas Pipe Loop
Gas Requirements
TMB2126N
SAMPLE CALCULATIONS:
Equivalent length = Total length of main gas supply pipe to the far end of the tumble dryers.
= 25 ft. + 19 ft. (7.6 m + 5.8 m) gas supply pipe
= 44 ft. (13.4 m) total gas line
Total Btu/hr. = The sum of the Btu/hr. of all 120 pound tumble dryers being fed by the main gas supply pipe.
= 9 x 270,000
= 2,430,000 Btu/hr.
Using Table 7, the main supply pipe diameter should be 3 in. (76 mm).
IMPORTANT: Gas loop piping must be installed as illustrated to equalize gas pressure for all tumble
dryers connected to single gas service. Other gas using appliances should be connected upstream from
loop.
To reduce the risk of electric shock, fire,
explosion, serious injury or death:
• Disconnect electric power to the tumble
dryer before servicing.
• Close gas shut-off valve to gas tumble
dryer before servicing.
• Close steam valve to steam tumble dryer
before servicing.
• Never start the tumble dryer with any
guards/panels removed.
• Whenever ground wires are removed
during servicing, these ground wires
must be reconnected to ensure that the
tumble dryer is properly grounded.
W002R1
To reduce the risk of fire and electric
shock, check with a qualified serviceman
for proper grounding procedures.
Improper connection of the equipment
grounding conductor may result in a risk
of electric shock.
W068
To reduce the risk of fire and electric
shock, if electrical supply is coming from a
three phase service, DO NOT connect a
“High Leg” or “Stinger Leg” to a single
phase machine. On a three phase machine,
if there is a “High Leg” or “Stinger Leg” it
should be connected to L3.
W069
WARNING
WARNING
In case of servicing (or putting the tumble
dryer out of order), disconnect the tumble
dryer from the main supply by switching
off the circuit breaker.
W796
IMPORTANT: Electrical connections must be
made by a qualified electrician using data on serial
plate, installation manuals and wiring diagram
provided with machine and according to local
codes. Install a circuit breaker as close to the
tumble dryer as possible. If more than one tumble
dryer is being installed, a circuit breaker must be
provided for each.
NOTE: Connect machine to an individual branch
circuit not shared with lighting or other equipment.
NOTE: 3 Phase Machines Only - Do not use fuses
to avoid the possibility of “single phasing” and
causing premature failure of the motors.
NOTE: To ensure protection against shock, this
tumble dryer MUST be electrically grounded in
accordance with the local codes or, in the absence of
local codes, with the latest edition of the National
Electrical Code ANSI/NFPA No. 70. In Canada the
electrical connections are to be made in accordance
with CSA C22.1 latest edition Canadian Electrical
Code, Part I and/or local codes. Electrical work
should be done by a qualified electrician.
This tumble dryer must be grounded. In the event of
malfunction or breakdown, grounding will reduce the
risk of electric shock by providing a path of least
resistance for electric current. This tumble dryer must
be connected to a grounded metal, permanent wiring
system; or an equipment grounding conductor must be
run with the circuit conductors and connected to the
appropriate ground location.
Metal conduit and/or BX cable is not considered
ground. Connecting the Neutral from the electrical
service box to the tumble dryer ground screw does not
constitute a ground. A dedicated ground conduit (wire)
must be connected between the electrical service box
ground bar and the tumble dryer ground screw.
70420801 (EN)
Page 39
For CE Models Only
All electrical connections should be made
by a qualified electrician.
To reduce the risk of electrical shock, deenergize the electrical circuit being
connected to the tumble dryer before
making any electrical connections. Never
attempt to connect a live circuit.
W070R1
WARNING
Label all wires prior to disconnection when
servicing controls. Wiring errors can
cause improper and dangerous operation.
Verify proper operation after servicing.
W071
CAUTION
Electrical Requirements
All models are factory-equipped with an emergency
stop button on the front panel.
NOTE: Activation of the emergency stop switch
stops all machine control circuit functions, but
DOES NOT remove all electrical power from
machine.
To Connect Electrical Service to the
Tumble Dry er
NOTE: The wiring diagram is located in the
junction or contactor box.
1. Install a circuit breaker as close to the tumble
dryer as possible. If more than one tumble dryer
is being installed, a circuit breaker should be
provided for each. This will make it possible to
disconnect each tumble dryer for maintenance
purposes.
2. Connect conduit-encased leads to the circuit
breaker. Connect wire leads to the appropriate
labeled terminal on the terminal block. The
ground wire must be connected to the ground
connection as shown in Figure 12.
3. Check the electrical service phase sequence
(three phase only). If one of the power leads is a
“high leg,” connect it to lead L3 in the tumble
dryer. The cylinder must rotate clockwise and the
fan must rotate counterclockwise (as viewed
from the front of the tumble dryer – with selector
switch in non-reverse position). If not,
interchange leads L1 and L2 in the tumble dryer
connection box.
Changing the transformer configuration jumper is
required, PRIOR TO SUPPLYING POWER TO
THE MACHINE, if any of the following apply:
IMPORTANT: Failure to install the proper
configuration jumper may result in damage to
sensitive electronic controls and may void
warranty.
Location Voltage 200 – 208 Volt service and are
connecting a model rated for 240 Volt operation.
Replace the 240 Volt jumper with the 208 Volt
jumper per the conversion label, located on the
rear of the tumble dryer, sign and date conversion
label to document the conversion.
You have 400 – 415 Volt service and are
connecting a model rated for 380 Volt operation.
Ferrite Ring Installation
Models with RM Control Suffix Only
The ferrite ring provided in the literature packet must
be installed over the power leads during connection of
electrical service. The ferrite protects the sensitive
electronic controls from destructive electrical
disturbances which may be present on power lines to
the machine. Failure to properly install the ferrite ring
may result in damage to the electronic controls and
will void control warranty.
To Install:
1. Immediately after connection of power leads and
before applying power to machine, locate each of
the incoming service leads including ground.
2. Snap the ferrite ring closed over all the service
leads inside of the contactor box as shown. It is
important that the ferrite ring be installed inside
the contactor box. Refer to Figure 13. Do not
install the ferrite outside of the box or other area.
Make sure that service leads are in the center of
the ferrite before closing the ring so not to pinch
or damage leads.
NOTE: Minimum wire sizes are obtained from
Canadian Electrical Code and are intended for use
as a guideline only. Electrical connections should be
made only by a qualified electrical contractor in
accordance with all applicable local and national
requirements.
NOTE: Electrical specifications below are subject
to change without notice. Always refer to product
serial plate for most current specifications of
product being installed.
For 120 Pound Gas and Steam Tumble Dryer Models
Serial Plate Rating
200-208V/60Hz/3ph
230V/50Hz/3ph
240V/60Hz/3ph
380V/50 or 60Hz/3ph
400-415V/50Hz/3ph
440V/60Hz/3ph
460-480V/60Hz/3ph
* Current ratings vary slightly depending on model; refer to serial plate.
L1,L2,L3 and ground7.715A - 3 pole14 (2.08)
L1,L2,L3 and ground7.315A - 3 pole14 (2.08)
L1,L2,L3 and ground7.315A - 3 pole14 (2.08)
L1,L2,L3 and ground4.110A - 3 pole14 (2.08)
L1,L2,L3 and ground3.810A - 3 pole14 (2.08)
L1,L2,L3 and ground3.810A - 3 pole14 (2.08)
L1,L2,L3 and ground3.910A - 3 pole14 (2.08)
Terminal Block
Connections Required
NOTE: Use copper conductors only.
NOTE: 3 Phase Only– Each tumble dryer must be
connected to its own individual branch circuit
breaker, not fuses, to avoid the possibility of “single
phasing” and causing premature failure of the
motor(s).
Rated
Current*
(amps)
Breaker
Rating
Recommended Wire
Size AWG (mm²)
For 120 Pound Electric Tumble Dryer Models
Serial Plate Rating
240V/60Hz/3ph
380V/50 or 60Hz/3ph
400-415V/50Hz/3ph
480V/60Hz/3ph
* Current ratings vary slightly depending on model; refer to serial plate.
L1,L2,L3 and ground152175A - 3 pole3/0 (85)
L1,L2,L3 and ground94.5125A - 3 pole1 (42.4)
L1,L2,L3 and ground87125A - 3 pole1 (42.4)
L1,L2,L3 and ground76.1100A - 3 pole3 (26.2)
Terminal Block
Connections Required
For 170 Pound Tumble Dryer Models
Serial Plate Rating
200-208V/60Hz/3ph
240V/60Hz/3ph
380V/50 or 60Hz/3ph
400-415V/50Hz/3ph
440V/60Hz/3ph
460-480V/60Hz/3ph
* Current ratings vary slightly depending on model; refer to serial plate.
All system components must have a
125 psig (8.6 bar) working pressure.
Shut-off valves must be installed upstream
of the steam solenoid valve and
downstream of each steam trap so
components can be isolated for
maintenance or emergency purposes.
All components (solenoid valve, traps)
must be supported to minimize loads on
the tumble dryer steam coil connections.
W480R2
NOTE: Machines require a constant 80 to 100 psig
(5.62 to 7.03 kg/sq. cm) steam service for optimum
operation. The maximum allowable steam pressure
for use with 60 Hertz or 50 Hertz tumble dryers is
125 psig (8.6 bar). In no case may the pressure
exceed the above value. Drying performance is
significantly reduced at lower steam pressures.
Obtain specific steam service pipe sizes from steam
system supplier or a qualified steam fitter.
Refer to Figure 14 and Figure 15 for proper
steam pipe configurations.
To prevent condensate draining from headers to
tumble dryer, piping should have a minimum
12 inch (305 mm) rise above respective header.
Do not make steam connection to header with a
horizontal or downward facing tee or elbow.
Whenever possible, horizontal runs of steam
lines must drain, by gravity, to respective steam
header. Water pockets or an improperly drained
steam header will provide wet steam, causing
improper operation of tumble dryer. If pockets or
improper drainage cannot be eliminated, install a
bypass trap to drain condensate from the low
point in the steam header to the return.
NOTE: To prevent water hammering, route return
lines below outlets of steam coils.
Piping Recommendations
Trap each steam coil individually. Always keep
the trap clean and in good working condition.
When tumble dryer is on the end of a line of
equipment, extend header at least 4 feet
(1.2 meters) beyond tumble dryer. Install shut-off
valve, union, check valve and bypass trap at end
of line. If gravity return to boiler, omit trap.
Insulate steam supply and return line for safety of
operator and safety while servicing tumble dryer.
Keep tumble dryer in good working condition.
Repair or replace any worn or defective parts.
In both steam supply and steam return line, it is
recommended that each have a pipe union and
shut-off valve. This will enable you to disconnect
the steam connections and service the tumble
dryer while your laundry facility is in operation.
Connect the steam solenoid valve to the related
steam coil inlet connection with nipples, flex
hoses, unions and tee.
Strainers may require cleaning due to materials
from hoses or pipes.
Install vacuum breaker (optional), bucket trap
with built-in strainer and check valve. For
successful operation of tumble dryer, install trap
18 inches (457 mm) below coil and as near to the
tumble dryer as possible. Inspect trap carefully
for inlet and outlet markings and install
according to trap manufacturer's instructions. If
steam is gravity returned to boiler, omit trap but
install vacuum breaker and check valve in return
line near tumble dryer.
Gravity return requires entire return plumbing be
below steam coil outlets.
Install union and shut-off valve in return line and
All system components must have a
125 psig (8.6 bar) working pressure.
Shut-off valves must be installed
upstream of the steam solenoid valve and
downstream of each steam trap so
components can be isolated for
maintenance or emergency purposes.
All components (solenoid valve, traps)
must be supported to minimize loads on
the tumble dryer steam coil connections.
W480R2
Installing Steam Trap and Making
Condensate Return Connections
The steam trap must be installed and the coil outlet
connections must be connected to the condensate
return lines. The following steps outline the procedure
for installing the steam trap and connecting the
condensate return lines. Refer to Figure 14 and
Figure 15 for typical installations.
1. Use flexible lines between steam inlet solenoid
and steam coils, as well as outlet between steam
coil and traps.
2. If necessary, install a strainer to the end of each
flexible hose.
3. Install a steam trap to each strainer.
IMPORTANT: Steam trap must be installed a
minimum of 18 inches (457 mm) below the steam
coil outlet connections.
4. Install a shut-off valve to each steam trap.
5. Connect to the condensate return lines.
6. For steam solenoid valve wiring connections,
refer to Wiring Diagram supplied with tumble
dryer.
Thermal Oil Prep
It is the responsibility of the customer to install
appropriate coil and heating system for thermal oil
prep models. Alliance Laundry Systems, LLC. is not
responsible for the performance or safety of the
customer installed thermal oil system. To ensure
proper operation, refer to the Specifications and Dimensions section for the BTU input of equivalent
steam models. Thermal oil systems that do not deliver
appropriate BTUs will dry slower. For solenoid valve
wiring connections, refer to the Wiring Diagram
supplied with tumble dryer.
To reduce the risk of electric shock, fire,
explosion, serious injury or death:
• Disconnect electric power to the tumble
dryer before servicing.
• Close gas shut-off valve to gas tumble
dryer before servicing.
• Close steam valve to steam tumble dryer
before servicing.
• Never start the tumble dryer with any
guards/panels removed.
• Whenever ground wires are removed
during servicing, these ground wires
must be reconnected to ensure that the
tumble dryer is properly grounded.
W002R1
WARNING
PROPER AIRFLOW
INSUFFICIENT AIRFLOW
NO AIRFLOW
1
1
1
Gas Burner Air Shutter
NOTE: Air inlet shutters on the burner must be
adjusted so sufficient air is metered into the system
for proper combustion and maximum efficiency.
Before adjusting the inlet shutters, be sure that all
lint is removed from lint compartments and lint
screen.
Air shutter adjustment will vary from location to
location and will depend on the vent system, number
of units installed, make-up air and line gas pressure.
Opening the shutter increases the amount of primary
air supplied to the burner, while closing the shutter
decreases the primary air supply. Adjust air shutter as
follows:
4. Open or close air shutter as necessary to obtain
proper flame intensity.
5. After air shutter is adjusted for proper flame,
tighten air shutter adjusting screw securely.
Refer to Figure 16.
1. Remove the upper access panel and burner
inspection hole plate.
2. Start the tumble dryer and check the flame
pattern. If the flame pattern is straight up,
insufficient air is flowing through the tumble
dryer. A flame pattern that flares to the right and
left indicates no air is flowing through the tumble
dryer. Correct air and gas mixture is indicated if
the flame pattern is primarily blue, with small
yellow tips, and bends to the left of the heater
section. Too little air is indicated if the flame is
yellow, lazy and smoky.
3. To adjust the air shutter, loosen air inlet shutter
adjusting screw.
The tumble dryer must not be operated if
the airflow switch does not operate
properly. Faulty airflow switch operation
may cause an explosive gas mixture to
collect in the tumble dryer.
W072R1
2
3
1
Airflow Switch
The airflow switch is set at the factory for proper
operation. No adjustment necessary.
The airflow switch operation may be affected by
shipping tape still in place, lack of make-up air, or an
obstruction in the exhaust duct. These should be
checked and the required corrective action taken.
IMPORTANT: Airflow switch vane must remain
closed during operation. If it opens and closes
during the drying cycle, this indicates insufficient
airflow through the tumble dryer. If switch remains
open, or pops open and closed during the cycle, the
heating system will shut off. The cylinder and fan
will continue to operate even though the airflow
switch is indicating insufficient airflow.
NOTE: To properly mount the airflow switch
bracket, or in case of a load not drying, the airflow
switch bracket may need to be checked for proper
alignment. Be sure the locator pins are securely in
their respective holes before tightening the bracket
1Door Strike
2Door Latch
3Jam Nut
T048I
mounting screws. This will assure proper
alignment of the airflow switch arm in the channel
of the airflow switch bracket and prevent binding
of the arm.
Loading Door Strike
The loading door strike must be adjusted to have
Loading Door Switch
Loading door switch is factory set; no field adjustment
necessary.
Figure 17
sufficient tension to hold loading door closed against
force of load tumbling against it. Proper adjustment is
when 8-15 pounds (35.6-66.7 N) pull is required to
open door.
If adjustment is required, refer to Figure 17 and
proceed as follows:
To adjust, open door, loosen jam nut and turn door
strike screw in or out as required. Retighten jam nut.
The drive assemblies consist of motors, belts, eyebolts
and a step pulley.
The pulley diameters are sized to produce a cylinder
speed of 37-39 RPM for 120 pound models or
29-31 RPM for 170 pound models.
The step pulley assembly is used for speed reduction
as well as a means of adjusting belt tension. The pulley
mounting plate is attached to the cabinet. The frame
mounting plate has vertically slotted holes allowing up
and down movement of the step pulley mounting plate
for belt adjustment.
Adjust the belt tension as follows:
1. Disconnect electrical power to the tumble dryer
before attempting any adjustments to the drive
assembly.
2. Loosen pulley mounting plate bolts.
3. Loosen the upper nut on the final drive eyebolt.
4. Rotate the lower nut of the final drive eyebolt
clockwise until proper belt tension is achieved.
5. Rotate upper nut clockwise against the lower nut
in order to lock it into place.
6. Tighten pulley mounting plate bolts. Recheck
belt tension.
7. If necessary, adjust the drive motor belt tension
eyebolt using a similar procedure.
8. Adjust blower belt tension on 120 pound
50 Hertz tumble dryers and all 170 pound tumble
dryers using a similar procedure.
NOTE: Proper tensions for new belts are
45-55 pounds for the motor belt, 55-65 pounds for
the final drive, 60-65 pounds for 120 pound blower,
and 75-80 pounds for 170 pound blower measured
with a Borroughs Belt Tension Gauge. Using a
Browning Belt Tension Gauge, the motor belt
deflection should be 0.31 inch at five pounds
pressure, and final drive belt deflection should be
0.25 inch at five pounds pressure.
Belts should not slip or make any noise when starting
up under normal load.