(If this machine changes ownership, this manual must accompany machine.)
www.comlaundry.com
TMB795C
Part No. 70420301ENR8
July 2012
Installation must conform with local codes or, in the absence of local codes, with:
• Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or
any other appliance.
• WHAT TO DO IF YOU SMELL GAS:
– Do not try to light any appliance.
– Do not touch any electrical switch; do not use any phone in your building.
– Clear the room, building or area of all occupants.
– Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s
instructions.
– If you cannot reach your gas supplier, call the fire department.
• Installation and service must be performed by a qualified installer, service agency or the gas
supplier.
W052
FOR YOUR SAFETY, the information in this manual must be followed to minimize the risk
of fire or explosion or to prevent property damage, personal injury or death.
W033
WARNING
In the U.S.A.
NFPA 54 “National Fuel Gas Code” and Standard ANSI/NFPA 70 “National Electric Code.”
In Canada
Installation Code and CSA C22.1, latest edition, Canadian Electric Code, Part I.
In Australia and New Zealand
Part 1: General Installations.
, installation must conform to the latest edition of the American National Standard Z223.1/
, installation must comply with Standards CAN/CSA-B149.1 or Natural Gas and Propane
, installation must comply with the Gas Installations Standard AS/NZS 5601
IMPORTANT: Information must be obtained from a local gas supplier on instructions to be followed if the
user smells gas. These instructions must be posted in a prominent location. Step-by-step instructions of the
above safety information must be posted in a prominent location near the tumble dryer for customer use.
The following information applies to the state of Massachusetts, USA.
• Installation of unit must be performed by a qualified installer.
• Install tumble dryer according to manufacturer’s instructions and local codes.
• DO NOT install a tumble dryer with flexible plastic venting materials. If flexible metal (foil
type) duct is installed, it must be of a specific type identified by the appliance manufacturer
as suitable for use with tumble dryer. Refer to section on connecting exhaust system.
Flexible venting materials are known to collapse, be easily crushed, and trap lint. These
conditions will obstruct tumble dryer airflow and increase the risk of fire.
W752R1
WARNING
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or
any other appliance.
W053
•This appliance can only be installed by a Massachusetts licensed plumber or gas fitter.
•This appliance must be installed with a 36 inch (91 cm) long flexible gas connector.
•A “T-Handle” type gas shut-off valve must be installed in the gas supply line to this appliance.
•This appliance must not be installed in a bedroom or bathroom.
If literature or replacement parts are required, contact
the source from which the machine was purchased or
contact Alliance Laundry Systems at (920) 748-3950
for the name and address of the nearest authorized
parts distributor.
For technical assistance, call (920) 748-3121.
Wiring Diagram
The wiring diagram is located in the junction or
contactor box.
The wiring diagram part number is in the lower
portion of the electrical data on the serial plate.
Serial Plate Location
When calling or writing for information about your
product, be sure to mention model and serial numbers.
Model and serial numbers are found on serial plate on
the rear of machine and inside door.
Indicates an imminently hazardous
situation that, if not avoided, will cause
severe personal injury or death.
DANGER
Indicates a hazardous situation that, if not
avoided, could cause severe personal
injury or death.
WARNING
Indicates a hazardous situation that, if not
avoided, may cause minor or moderate
personal injury or property damage.
CAUTION
Failure to install, maintain, and/or operate
this machine according to manufacturer’s
instructions may result in conditions which
can produce serious injury, death and/or
property damage.
W051R1
WARNING
Precautionary statements (“DANGER,” “WARNING,”
and “CAUTION”), followed by specific instructions,
are found in this manual and on machine decals. These
precautions are intended for the personal safety of the
operator, user, servicer, and those maintaining the
machine.
NOTE: The word “NOTE” is used to communicate
installation, operation, maintenance or servicing
information that is important but not hazard
related.
NOTE: The WARNING and IMPORTANT
instructions appearing in this manual are not
meant to cover all possible conditions and
situations that may occur. It must be understood
that common sense, caution and carefulness are
factors which CANNOT be built into this tumble
dryer. These factors MUST BE supplied by the
person(s) installing, maintaining or operating the
tumble dryer.
Additional precautionary statements (“IMPORTANT”
and “NOTE”) are followed by specific instructions.
IMPORTANT: The word “IMPORTANT” is used
to inform the reader of specific procedures where
minor machine damage will occur if the procedure
is not followed.
Always contact your dealer, distributor, service agent
or the manufacturer on any problems or conditions you
do not understand.
Hazardous Voltage. Can cause shock, burn
or cause death. Allow machine power to
remain off for two minutes prior to working
in and around AC inverter drive.
W359
WARNING
Safety Information
Important Safety Instructions
1. Read all instructions before using the tumble
dryer.
2. Refer to the GROUNDING INSTRUCTIONS
for the proper grounding of the tumble dryer.
3. Do not dry articles that have been previously
cleaned in, washed in, soaked in, or spotted with
gasoline, dry cleaning solvents, other flammable
or explosive substances as they give off vapors
that could ignite or explode.
4. Do not allow children on or in the tumble dryer.
This appliance is not intended for use by young
children or infirm persons without supervision.
Young children should be supervised to ensure
that they do not play with the appliance.
5. Before the tumble dryer is removed from service
or discarded, remove the door to the drying
compartment and the door to the lint
compartment.
6. Do not reach into the tumble dryer if the cylinder
is revolving.
7. Do not install or store the tumble dryer where it
will be exposed to water and/or weather.
8. Do not tamper with the controls.
9. Do not repair or replace any part of the tumble
dryer, or attempt any servicing unless specifically
recommended in the user-maintenance
instructions or in published user-repair
instructions that you understand and have the
skills to carry out.
13. Keep area around the exhaust opening and
adjacent surrounding area free from the
accumulation of lint, dust and dirt.
14. The interior of the tumble dryer and the exhaust
duct should be cleaned periodically by qualified
service personnel.
15. If not installed, operated and maintained in
accordance with the manufacturer’s instructions
or if there is damage to or mishandling of this
product’s components, use of this product could
expose you to substances in the fuel or from fuel
combustion which can cause death or serious
illness and which are known to the State of
California to cause cancer, birth defects or other
reproductive harm.
16. Tumble dryer will not operate with the loading
door open. DO NOT bypass the door safety
switch to permit the tumble dryer to operate with
the door open. The tumble dryer will stop
tumbling when the door is opened. Do not use the
tumble dryer if it does not stop tumbling when
the door is opened or starts tumbling without
pressing or turning the START mechanism.
Remove the tumble dryer from use and call for
service.
17. Tumble dryer will not operate with lint panel
open. DO NOT bypass lint panel safety switch to
permit the tumble dryer to operate with the lint
panel open.
18. Do not put articles soiled with vegetable or cooking
oil in the tumble dryer, as these oils may not be
removed during washing. Due to the remaining
oil, the fabric may catch on fire by itself.
19. To reduce the risk of fire, DO NOT put clothes
which have traces of any flammable substances
such as machine oil, flammable chemicals,
thinner, etc. or anything containing wax or
chemicals such as in mops and cleaning cloths, or
anything dry-cleaned at home with dry-cleaning
solvent in the tumble dryer.
10. Do not use fabric softeners or products to
eliminate static unless recommended by the
manufacturer of the fabric softener or product.
11. To reduce the risk of fire, DO NOT DRY plastics
or articles containing foam rubber or similarly
textured rubberlike materials.
20. Use the tumble dryer only for its intended
purpose, drying fabrics.
21. ALWAYS disconnect and lockout the electrical
power to the tumble dryer before servicing.
Disconnect power by shutting off appropriate
breaker or fuse.
9
Safety Information
WARNING
To reduce the risk of serious injury, install
lockable door(s) to prevent public access
to rear of tumble dryers.
W055R1
22. Install this tumble dryer according to the
INSTALLATION INSTRUCTIONS. All
connections for electrical power, grounding, and
gas supply must comply with local codes and be
made by licensed personnel when required.
23. Remove laundry immediately after tumble dryer
stops.
24. Always read and follow manufacturer’s
instructions on packages of laundry and cleaning
aids. Heed all warnings or precautions. To reduce
the risk of poisoning or chemical burns, keep
them out of reach of children at all times
(preferably in a locked cabinet).
25. Do not tumble fiberglass curtains and draperies
unless the label says it can be done. If they are
dried, wipe out the cylinder with a damp cloth to
remove particles of fiberglass.
26. Always follow the fabric care instructions
supplied by the garment manufacturer.
27. Never operate the tumble dryer with any guards
and/or panels removed.
28. DO NOT operate the tumble dryer if it is
smoking, grinding, has missing or broken parts.
29. DO NOT bypass any safety devices.
30. Solvent vapors from dry-cleaning machines
create acids when drawn through the heater of the
drying unit. These acids are corrosive to the
tumble dryer as well as to the laundry load being
dried. Be sure make-up air is free of solvent
vapors.
31. Failure to install, maintain, and/or operate this
machine according to the manufacturer’s
instructions may result in conditions which can
produce bodily injury and/or property damage.
Upon delivery, visually inspect the crate, carton and
parts for any visible shipping damage. If the crate,
carton, or cover is damaged or signs of possible
damage are evident, have the carrier note the condition
on the shipping papers before the shipping receipt is
signed, or advise the carrier of the condition as soon as
it is discovered.
Remove the crate and protective cover as soon as
possible and check the items listed on the packing list.
Advise the carrier of any damaged or missing articles
as soon as possible. A written claim should be filed
with the carrier immediately if articles are damaged or
missing.
IMPORTANT: Remove the shipping tape from the
two back draft dampers located in the exhaust
outlet.
IMPORTANT: Warranty is void unless tumble
dryer is installed according to instructions in this
manual. Installation should comply with minimum
specifications and requirements detailed in this
manual and applicable local gas fitting regulations,
municipal building codes, water supply regulations,
electrical wiring regulations, and any other
relevant statutory regulations. Due to varied
requirements, applicable local codes should be
thoroughly understood and all pre-installation
work arranged for accordingly.
Materials Required (Obtain Locally)
One Single Pole fused disconnect
All Models
Gas Models
Steam Models
switch or circuit breaker on 1 Phase
models.
Circuit breaker on 3 Phase models.
One gas shut-off valve for gas service
line to each tumble dryer.
One steam shut-off valve for steam
service line to be connected upstream of
solenoid steam valve.
Two steam shut-off valves for each
condensate return line.
Flexible steam hoses with a 125 psig
(pounds per square inch gauge)
(8.79 kg/sq. cm) working pressure for
connecting steam coils. Refer to
Figure 22for sizing and connection
configurations.
Two steam traps for steam coil outlets
to condensate return line.
Optional – Two vacuum breakers for
condensate return lines.
IMPORTANT: Keep tumble dryer area clear and
free from combustible materials, gasoline and other
flammable vapors and liquids.
NOTE: 3 Phase Only – Each tumble dryer must be
connected to its own individual branch circuit
breaker, not fuses, to avoid the possibility of “single
phasing” and causing premature failure of the
motor(s).