Installer Checklist ........................................................... Back Cover
Date Purchased ________________
Model Number ________________
Serial Number _________________
Para bajar una copia de estas instrucciones en español, visite www.comlaundry.com.
Keep these instructions for future reference.
(If this machine changes ownership, this manual must accompany machine.)
www.comlaundry.com
Part No. 802715
December 2006
WARNING
FOR YOUR SAFETY, the information in this manual must be followed to minimize the risk of
fire or explosion or to prevent property damage, personal injury or death.
W033
• Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or
any other appliance.
• WHAT TO DO IF YOU SMELL GAS:
– Do not try to light any appliance.
– Do not touch any electrical switch; do not use any phone in your building.
– Clear the room, building or area of all occupants.
– Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s
instructions.
– If you cannot reach your gas supplier, call the fire department.
• Installation and service must be performed by a qualified installer, service agency or the gas
supplier.
W052
WARNING
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance.
The following information applies to the state of Massachusetts, USA.
•This appliance can only be installed by a Massachusetts licensed plumber or gas fitter.
•This appliance must be installed with a 36 inch (91 cm) long flexible gas connector.
•A “T-Handle” type gas shut-off valve must be installed in the gas supply line to this appliance.
•This appliance must not be installed in a bedroom or bathroom.
For most installations, the basic supplies you will need
are:
1
2
5
4
8
9
3
6
9
/
1
6
"
7
WARNING
Any disassembly requiring the use of
tools must be performed by a suitably
qualified service person.
W299
NOTE: If the the unit is delivered on a cold day
(below freezing), or is stored in an unheated room
or area during the cold months, do not attempt to
operate it until the unit has had a chance to warm
up.
NOTE: Some moisture in the wash drum is normal.
Water is used during testing at the manufacturer.
Move unit as close to the desired area of installation as
possible.
WARNING
Washer and dryer are not designed to be
operated as separated, side-by-side units.
W187
NOTE: For best performance and to minimize
vibration or movement, install washer on a solid,
sturdy and level floor. Some floors may need to be
reinforced, especially on a second floor or over a
basement. Do not install the washer on carpeting,
soft tile, a platform or other weakly supported
structures.
Step 2: Connect Fill Hoses
WARNING
Under certain conditions, hydrogen gas
may be produced in a hot water system
that has not been used for two weeks or
more. HYDROGEN GAS IS EXPLOSIVE. If
the hot water system has not been used
for such a period and before using the
washer, turn on all hot water faucets and
let the water flow from each for several
minutes. This will release any
accumulated hydrogen gas. The gas is
flammable. Do not smoke or use an open
flame during this time.
W029
Water supply faucets must fit standard 3/4 inch
(19.1 mm) female garden hose couplings. DO NOT
USE SLIP-ON OR CLAMP-ON CONNECTIONS.
Water supply faucets should be readily accessible to
permit turning them off when washer is not being
used.
o
Recommended cold water temperature is 60
o
80
Fahrenheit (16o to 27o Celsius). Recommended
hot water temperature is 120
o
(49
to 60o Celsius). Warm water is a mixture of hot
o
to 140o Fahrenheit
to
and cold water. Warm water temperature is dependent
upon water temperature and pressure of both the hot
and cold water supply lines.
Water pressure must be a minimum of 20 to a
maximum of 120 pounds per square inch (138 to
827 kPa) static pressure measured at the faucet.
NOTE: Water pressure under 20 pounds per
square inch (138 kPa) will cause an extended fill
time in the washer and may not properly flush out
the detergent dispenser.
Turn on the water faucets and flush the lines for
approximately two minutes to remove any foreign
material that could clog the screens in the water
mixing valve.
NOTE: When installing in newly constructed or
renovated buildings, it is very important to flush
the lines since build-up may have occurred during
construction.
Remove the two plain rubber washers and two filter
screens from the accessories bag. Install them into
each end of the fill hoses as shown in Figure 2. The
screen must be facing outward.
Screw hose couplings with the filter screens onto the
water faucets until they are finger-tight. Then, using a
pliers, screw approximately 1/4 turn.
Screw hose couplings from other end of hoses onto the
water mixing valve until they are finger-tight. Then,
using a pliers, screw approximately 1/4 turn. Refer to
Figure 3.
IMPORTANT: Do not cross thread or overtighten
couplings. This will cause them to leak.
Turn water on and check for leaks. If leaks are found,
turn off the water, unscrew hoses and reinstall them
until there are no leaks.
IMPORTANT: Turn off water supply whenever
there will be an extended period of non-use.
1
COLD
HOT
5
2
3
IMPORTANT: Hoses and other natural rubber
parts deteriorate after extended use. Hoses may
develop cracks, blisters or material wear from the
temperature and constant high pressure they are
subject to.
All hoses should be checked on a yearly basis for
any visible signs of deterioration. Any hose showing
the signs of deterioration listed above should be
replaced immediately. All hoses should be replaced
every five years.
1
4
1 Water Faucets
2Cold Water Connection
3Hot Water Connection
4Water Fill Hoses
IMPORTANT: Turn off water supply faucets after
check-out and demonstration. Owner should turn
off water supply whenever there will be an
extended period of non-use.
NOTE: Longer fill hoses are available (as optional
equipment at extra cost) if the hoses supplied with
the washer are not long enough for the installation.
Figure 3
Figure 2
Order hoses as follows:
No. 20617 Fill Hose (8 feet) (2.44 m)
No. 20618 Fill Hose (10 feet) (3.05 m)
Risers (or air cushions) may have to be installed if the
pipes knock or pound when flow of water stops. The
risers are more efficient when installed as close as
possible to the water supply faucets (refer to Figure 4).
2
1
1 Water Supply Faucets
2Risers (Air Cushions)
Figure 4
W005I
W005I
Step 3: Connect Drain Hose to Drain
Receptacle
Remove the drain hose from its shipping position on
the rear of the washer by unhooking the hose from the
retainer clamp and by removing the shipping tape.
Install the drain hose into the drain receptacle
(standpipe, wall or laundry tub) following the
instructions below.
IMPORTANT: Drain receptacle must be capable of
handling a minimum of 1-1/4 inch (32 cm) outside
diameter drain hose.
Standpipe Installation:
Place the drain hose into the standpipe.
Remove the beaded strap from accessories bag and
place around standpipe and drain hose and tighten
strap to hold hose to standpipe. Refer to Figure 5. This
will prevent the drain hose from dislodging from drain
receptacle during use.
1
802715
24 in. to 36 in.
(61 to 91.44 cm)
Recommended
Height
2
3
1 Drain Hose
2Beaded Tie-Down Strap
3Standpipe 2 in. (5.08 cm) or 1-1/2 in. (4 cm)
For installations of this type, the drain hose MUST be
secured to one of the fill hoses using the beaded strap
from accessories bag. Refer to Figure 6.
NOTE: End of drain hose must be below 24 in.
(61 cm).
1
2
3
H023I
1 Drain Hose
2Beaded Strap (tape if necessary)
3Fill Hoses
For this type of installation, the drain hose MUST be
secured to the stationary tub to prevent hose from
dislodging during use. Refer to Figure 7. Use the
beaded strap (supplied in accessories bag) to secure
hose.