(If this machine changes ownership, this manual must accompany machine.)
www.comlaundry.com
Part No. 70380401R5
September 2008
Installation must conform with local codes or in the absence of local codes with:
In the U.S.A.
, installation must conform to the latest edition of the American National Standard Z223.1/
NFPA 54 “National Fuel Gas Code” and Standard ANSI/NFPA 70 “National Electric Code.”
In Canada
, installation must comply with Standards CAN/CSA-B149.1 or Natural Gas and Propane Code
CSA C22.1, latest edition, Canadian Electric Code, Part I.
In Australia
, installation must comply with the Australian Gas Association Installation Code for Gas
Burning Appliances and Equipment.
WARNING
FOR YOUR SAFETY, the information in this
manual must be followed to minimize the
risk of fire or explosion or to prevent
property damage, personal injury or death.
W033
POUR VOTRE SÉCURITÉ, les informations
de ce guide doivent être respectées afin de
réduire les risques d’incendie, d’explosion
ou d’éviter les dommages matériels,
personnels ou blessures mortelles.
WARNING
• Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
• WHAT TO DO IF YOU SMELL GAS:
– Do not try to light any appliance.
– Do not touch any electrical switch; do
not use any phone in your building.
– Clear the room, building or area of all
occupants.
– Immediately call your gas supplier from
a neighbor’s phone. Follow the gas
supplier’s instructions.
– If you cannot reach your gas supplier,
call the fire department.
• Installation and service must be
performed by a qualified installer, service
agency or the gas supplier.
W052
• Ne pas entreposer ou utiliser d’essence
ou toutes autres vapeurs et liquides
inflammables à proximité de cette
machine ou de tout autre appareil.
• QUE FAIRE EN CAS D’ODEUR DE GAZ :
– Ne pas mettre d’appareil en marche.
– Ne pas toucher aux interrupteurs
électriques ; ne pas utiliser le
téléphone des lieux.
– Évacuer la pièce, le bâtiment ou la zone
de tous les occupants.
– Appeler immédiatement le fournisseur
de gaz de la maison d’un voisin.
Respecter les instructions
communiquées par le fournisseur.
– Si vous ne pouvez pas joindre le
fournisseur de gaz, appeler le service
d’incendie.
FOR YOUR SAFETY
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
W053
• L’installation et l’entretien doivent être
effectués par un installateur, service
d’entretien qualifiés ou par le fournisseur
de gaz.
W033R3QU
W052R5QU
POUR VOTRE SÉCURITÉ
Ne pas entreposer ou utiliser d’essence ou
toutes autres vapeurs et liquides
inflammables à proximité de cette unité ou
de tout autre appareil.
W053R2QU
IMPORTANT: Information must be obtained from a local gas supplier on instructions to be followed if the
user smells gas. These instructions must be posted in a prominent location. Step-by-step instructions of the
above safety information must be posted in a prominent location near the tumbler for customer use.
If literature or replacement parts are required, contact
the source from which the machine was purchased or
contact Alliance Laundry Systems at (920) 748-3950
for the name and address of the nearest authorized
parts distributor.
For technical assistance, call (920) 748-3121.
Serial Plate Location
When calling or writing for information about your
product, be sure to mention model and serial numbers.
Model and serial numbers are found on serial plate on
rear of machine, and inside door hinge. Refer to
Figure 1.
Wiring Diagram
The wiring diagram is located in the junction or
contactor box. The wiring diagram part number in the
lower portion of the electrical data on the serial plate.
Precautionary statements (“DANGER,” “WARNING,”
and “CAUTION”), followed by specific instructions,
are found in this manual and on machine decals. These
precautions are intended for the personal safety of the
operator, user, servicer, and those maintaining the
machine.
DANGER
Indicates an imminently hazardous
situation that, if not avoided, will cause
severe personal injury or death.
WARNING
Indicates a hazardous situation that, if not
avoided, could cause severe personal
injury or death.
CAUTION
Indicates a hazardous situation that, if not
avoided, may cause minor or moderate
personal injury or property damage.
Additional precautionary statements (“IMPORTANT”
and “NOTE”) are followed by specific instructions.
IMPORTANT: The word “IMPORTANT” is used
to inform the reader of specific procedures where
minor machine damage will occur if the procedure
is not followed.
IMPORTANT: Warranty is void unless tumbler
is installed according to instructions in the
Installation Manual. Compliance with minimum
specifications and requirements detailed herein,
and with applicable local gas fitting regulations,
municipal building codes, water supply regulations,
electrical wiring regulations, and any other
relevant statutory regulations. Because of varied
requirements, applicable local codes should be
thoroughly understood and all pre-installation
work arranged for accordingly.
WARNING
Failure to install, maintain, and/or operate
this machine according to manufacturer’s
instructions may result in conditions which
can produce serious injury, death and/or
property damage.
W051R1
NOTE: The WARNING and IMPORTANT
instructions appearing in this manual are not
meant to cover all possible conditions and
situations that may occur. It must be understood
that common sense, caution and carefulness are
factors which CANNOT be built into this tumbler.
These factors MUST BE supplied by the person(s)
installing, maintaining or operating the tumbler.
Always contact your dealer, distributor, service agent
or the manufacturer on any problems or conditions you
do not understand.
NOTE: The word “NOTE” is used to communicate
installation, operation, maintenance or servicing
information that is important but not hazard
related.
Hazardous Voltage. Can cause shock, burn
or cause death. Allow machine power to
remain off for two minutes prior to working
in and around AC inverter drive.
W359
1. Read all instructions before using the tumbler.
2. Refer to the GROUNDING INSTRUCTIONS
for the proper grounding of the tumbler.
3. Do not dry articles that have been previously
cleaned in, washed in, soaked in, or spotted with
gasoline, dry cleaning solvents, other flammable
or explosive substances as they give off vapors
that could ignite or explode.
4. Do not allow children on or in the tumbler. This
appliance is not intended for use by young
children or infirm persons without supervision.
Young children should be supervised to ensure
that they do not play with the appliance.
5. Before the tumbler is removed from service or
discarded, remove the door to the drying
compartment and the door to the lint
compartment.
6. Do not reach into the tumbler if the cylinder is
revolving.
7. Do not install or store the tumbler where it will
be exposed to water and/or weather.
8. Do not tamper with the controls.
9. Do not repair or replace any part of the tumbler,
or attempt any servicing unless specifically
recommended in the user-maintenance
instructions or in published user-repair
instructions that you understand and have the
skills to carry out.
10. Do not use fabric softeners or products to
eliminate static unless recommended by the
manufacturer of the fabric softener or product.
11. To reduce the risk of fire, DO NOT DRY plastics
or articles containing foam rubber or similarly
textured rubberlike materials.
14. The interior of the tumbler and the exhaust duct
should be cleaned periodically by qualified
service personnel.
15. If not installed, operated and maintained in
accordance with the manufacturer’s instructions
or if there is damage to or mishandling of this
product’s components, use of this product could
expose you to substances in the fuel or from fuel
combustion which can cause death or serious
illness and which are known to the State of
California to cause cancer, birth defects or other
reproductive harm.
16. Tumbler will not operate with the loading door
open. DO NOT bypass the door safety switch to
permit the tumbler to operate with the door open.
The tumbler will stop tumbling when the door is
opened. Do not use the tumbler if it does not stop
tumbling when the door is opened or starts
tumbling without pressing or turning the START
mechanism. Remove the tumbler from use and
call for service.
17. Tumbler will not operate with lint panel open.
DO NOT bypass lint panel safety switch to
permit the tumbler to operate with the lint panel
open.
18. Do not put articles soiled with vegetable or cooking
oil in the tumbler, as these oils may not be
removed during washing. Due to the remaining
oil, the fabric may catch on fire by itself.
19. To reduce the risk of fire, DO NOT put clothes
which have traces of any flammable substances
such as machine oil, flammable chemicals,
thinner, etc. or anything containing wax or
chemicals such as in mops and cleaning cloths, or
anything dry-cleaned at home with dry-cleaning
solvent in the tumbler.
20. Use the tumbler only for its intended purpose,
drying fabrics.
21. ALWAYS disconnect and lockout the electrical
power to the tumbler before servicing. Disconnect
power by shutting off appropriate breaker or fuse.
22. Install this tumbler according to the
INSTALLATION INSTRUCTIONS. All
connections for electrical power, grounding, and
gas supply must comply with local codes and be
made by licensed personnel when required.
12. Always clean the lint filter daily.
13. Keep area around the exhaust opening and
adjacent surrounding area free from the
accumulation of lint, dust and dirt.
23. Remove laundry immediately after tumbler stops.
24. Always read and follow manufacturer’s
instructions on packages of laundry and cleaning
aids. Heed all warnings or precautions. To reduce
the risk of poisoning or chemical burns, keep
them out of reach of children at all times
(preferably in a locked cabinet).
25. Do not tumble fiberglass curtains and draperies
unless the label says it can be done. If they are
dried, wipe out the cylinder with a damp cloth to
remove particles of fiberglass.
26. Always follow the fabric care instructions
supplied by the garment manufacturer.
27. Never operate the tumbler with any guards and/or
panels removed.
28. DO NOT operate the tumbler if it is smoking,
grinding, has missing or broken parts.
29. DO NOT bypass any safety devices.
30. Solvent vapors from dry-cleaning machines
create acids when drawn through the heater of the
drying unit. These acids are corrosive to the
tumbler as well as to the laundry load being
dried. Be sure make-up air is free of solvent
vapors.
31. Failure to install, maintain, and/or operate this
machine according to the manufacturer’s
instructions may result in conditions which can
produce bodily injury and/or property damage.
WARNING
To reduce the risk of serious injury, install
lockable door(s) to prevent public access
to rear of tumblers.
• DO NOT DRY articles containing foam rubber or similarly textured rubberlike materials.
• DO NOT DRY plastics, anything containing wax or chemicals such as mops and cleaning
cloths, or anything dry-cleaned at home with a dry-cleaning solvent.
• DO NOT TUMBLE fiberglass curtains and draperies unless the label says it can be done. If
they are dried, wipe out the cylinder with a damp cloth to remove particles of fiberglass.
To reduce the risk of serious injury, allow cylinder to stop before cleaning lint screen.
W076
W412
Emergency Stop Button on CE
Models
All CE approved OPL tumblers are factory equipped
with an emergency stop button located on the front
panel. Refer to Figure 2.
1
TMB1664N
Emergency Stop Button
1
Figure 2
To operate emergency stop button:
a. Press red emergency stop button to stop all
action.
b. To restart machine, pull red emergency stop
button out and press START pad or button.
NOTE: Activation of the emergency stop button
stops all machine control circuit functions, but
DOES NOT remove all electrical power from
machine.
Operating Instructions
Step 1: Clean Lint Screen/Compartment
Remove any accumulated lint from the lint screen and
compartment. Close panel tightly against tumbler
frame and lock panel securely, if applicable.
IMPORTANT: Clean lint screen and lint
compartment daily. Failure to clean the lint screen
daily will result in higher than normal
temperatures that may damage laundry.
Step 2: Load Laundry
Open loading door and load cylinder with laundry. DO
NOT OVERLOAD.
NOTE: Overloading causes slow drying and
wrinkling.
Close loading door. Tumbler will not operate with the
door open.
Step 3: Determine Control Type and
Temperature Setting
Refer to the various controls, pages 9 - 17, follow
instructions for the appropriate control type.
The type of fabric being dried will determine the
temperature setting. Consult the fabric care label or
fabric manufacturer to determine proper temperature
setting.
IMPORTANT: Always follow the fabric care
instructions supplied by the garment manufacturer.
Step 4: Remove Laundry
When the cycle is complete, open door and remove the
laundry.
1. Select HIGH, MED, LOW or NO HEAT by
turning the temperature knob.
HIGH temperature190°F (87°C)
MED temperature170°F (77°C)
LOW temperature120°F (49°C)
2. Set the HEAT TIME for the number of minutes
(from 0 - 60) desired.
3. Set the COOL DOWN TIME for the number of
minutes (from 0 - 15) desired.
4. Display will show minutes remaining before end
of cycle.
NOTE: One touch drying is available for repetitive
loads. If the START button is pressed while the
machine is in Idle Mode, when the display is dark,
the tumbler will repeat the last drying cycle. If the
cycle time is adjusted before the cycle is started, the
time displayed when the start button was pressed
will be used for future cycles.
TMB2133N
Figure 3
IMPORTANT: To stop the tumbler at any time
during the cycle, OPEN DOOR. If the loading door
or lint panel door is opened during the cycle, the
heating system will shut off and the motor will stop.
To restart the cycle, both doors must be closed and
the START button must be pressed in.
If the load cools to 90° F before cool down time
expires, the control will flash “Lr” (load ready) in the
heat time display. If the door is not opened, the
tumbler completes the selected cool down time. If the
door is opened after reaching “Lr” temperature, the
cycle will be terminated.
NOTE: If display shows an error code, refer to
Error Codes section.
5. When the cycle is complete, open door and
remove the laundry. Anti-wrinkle feature will
tumble the load without heat for 30 seconds every
2 minutes for 1 hour OR until the loading door is
opened.
NOTE: This machine includes an anti-wrinkle/
extended tumble feature. After the drying cycle is
complete, the cylinder will tumble without heat
every few minutes. The intermittent tumbling will
continue for one hour or until the door is opened.
1. To use an Automatic Cycle, press an ON/
SELECT pad. Select HIGH, MEDIUM,
MED LOW, LOW or NO HEAT for items that
should not be dried with heat. A light to the left
of the selected pad lights up.
To use a Time Dry or Custom Cycle, refer to the
Programming Manual.
NOTE: Do not press directly on lights or the center
of pad. For proper selection, press on pad slightly
to the right of center. Refer to Figure 5.
STATUS
DRYING
COOL DOWN
DOOR OPEN
CUSTOM
Figure 4
PROGRAM
*
AUTO
AUTO
SPECIAL
CYCLE
AUTO
TEMP
MORE
TIME
SPECIAL
TIME
COOL
*
DOWN
LESS
+--
CONDITION
2. Press START pad to start tumbler.
NOTE: All pads can be pressed in any sequence
without damaging control or tumbler. To stop the
tumbler at any time, open the door or press STOP/
RESET. The window display will flash. Press
STOP/RESET twice (within 3 seconds) to end the
cycle and reset the control to idle status. To restart
the tumbler, CLOSE door and press START pad.
IMPORTANT: If the loading door or lint panel
door is opened during the cycle, the heating system
will shut off and the motor will stop. To restart the
cycle, both doors must be closed and the PUSH TO
START button must be pressed in.
SAVE
CUSTOM
PROG
TMB1789N
TMB1789N
70380401
3. When the cycle is complete, open door and
remove the laundry.
NOTE: This machine includes an anti-wrinkle/
extended tumble feature. After the drying cycle is
complete, the cylinder will tumble without heat
every few minutes. The intermittent tumbling will
continue for one hour or until the door is opened.
1. Select HIGH, MED, LOW or NO HEAT by
turning the temperature knob.
HIGH temperature190°F (87°C)
MED temperature160°F (71°C)
LOW temperature130°F (54°C)
2. Insert the coin(s) in the coin slot.
3. Press START button to start tumbler.
IMPORTANT: To stop the tumbler at any time
during the cycle, OPEN DOOR. To restart the
tumbler, CLOSE door and press START button.
NOTE: If display show an error code, refer to Error Codes section.
4. When the cycle is complete, open door and
remove the laundry.
NOTE: This machine includes an extended tumble
feature. Starting 20 minutes after a cycle ends, the
cylinder will tumble for two minutes every hour
without heat, up to 18 hours or until door is
opened.
TMB2123N
Figure 6
Preliminary Control Information
Power-Up Mode
When power is applied to the tumbler the control will
enter Ready Mode, unless a cycle was in process prior
to a disruption of power. If a power disruption is less
than 5 seconds, with a cycle in process, the control will
enter Run Mode once power is restored and continue
the cycle. If a power disruption is more than 5 seconds,
with a cycle in process, the control will enter Start
Mode once power is restored.
If the dry time dipswitch settings have not changed
from the factory default, the IN USE LED will flash
two to five times, depending on model.
Ready Mode
In Ready Mode, the control waits for the vend to be
satisfied before entering Start Mode.
Start Mode
In Start Mode, the vend has been satisfied, but the
Start button has not been pressed. The IN USE LED
will be lit. The timer will not count down until the
Start button is pressed.
Run Mode
In Run Mode, the control is running a cycle. The IN
USE LED is lit.
In Door Open Mode, the control turns off the heater
and motor when the door is opened during a run cycle.
The timer will continue to count down time and the IN USE LED is lit.
End of Cycle Mode
In End of Cycle Mode, a cycle is complete and the IN
USE LED is off. The control remains in this mode
until the door is opened or additional vend has been
satisfied.
Topoffs
Any time the control receives a coin drop pulse during
a cycle it will add the programmed dry time to the time
currently remaining in the cycle. The maximum cycle
time is 99 minutes, the control will not add time
beyond 99 minutes. The cool down time will not
change.
If the control receives a coin drop pulse during cool
down the IN USE LED will flash briefly to indicate the
coin input, the machine will exit cool down and it will
start heating. The cycle time will be equal to the
programmed dry time
NOTE: To change dipswitch settings refer to
Installation Manual.
To Program a Short Test Cycle:
1. Unplug machine power cord.
2. Write down machine control dip switch settings,
then set them all to the off position. Refer to
Figure 7.
3. Plug machine in and start a cycle.
NOTE: With all control dip switches off, the total
cycle time will be 1 minute long.
4. Once all testing is complete, unplug machine and
re-set dip switches to their original settings.
5. Plug machine in.
1 2 3 4 5 6 7 8
O
N
Temperature Selector Switch
For five minutes after the control is powered up, there
78
6
2345
1
is a diagnostic feature that allows the temperature
selector switches to be tested.
When the temperature selector is changed, the new
setting is displayed by flashing the IN USE LED as
follows:
High/Normal: 4 flashes
Figure 7
Medium/PP: 3 flashes
Low/Delicate: 2 flashes
No Heat: 1 flash
Error Codes
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
After 24 VAC is applied to the ignition control pins
24V and GND, the Diagnostic LED on the ignition
control will turn orange/yellow. If a fault is detected
the ignition control will enter Lockout Mode. If no
faults are detected, the Diagnostic LED will turn
Green and the ignition control will enter Standby
Mode.
Standby Mode
While in Standby Mode, the ignition control will
continually monitor the system for faults. Once
24VACis applied to terminals TH and GND on the
control, the ignition control will enter Start Up Mode.
Start Up Mode
During Start Up Mode, the ignition control will
monitor the system for faults and begin the ignition
sequence. If no faults are present, the ignition control
will begin the ignition sequence by entering an 18
second waiting period. During this time the Green
LED on the ignition control will switch between Red
and Green, before maintaining a Green color.
After the waiting period, the ignition control will turn
on the igniter and gas valve. The igniter will remain on
until a flame is sensed, or up to 10 seconds.
Once a flame has been sensed the ignition control will
stop sparking, the gas valve will remain on and
ignition control will enter Run Mode.
If a flame is not sensed, the ignition control will then
begin two additional retrials for ignition. The ignition
control will re-enter the 18 seconds waiting period
before the ignition control makes another attempt at
ignition. If the three attempts at ignition fail, the
ignition control will enter Lockout Mode.
Run Mode
While in Run Mode the ignition control leaves the gas
valve on, monitors the flame signal, and leaves the
igniter off.
If a flame signal is lost during Run Mode, one
additional retrial for ignition will take place within one
second. The ignition control will restore the spark for
approximately 10 seconds. If the ignition re-attempt
fails, the ignition control will enter Lockout Mode.
The ignition control will remain in Run Mode until
24VAC is removed from terminals TH and GND on
the control.
Termination of Flame
The flame will go out when power is removed from
ignition control. The ignition control will turn off the
gas valve and enter Standby Mode.
Lockout Mode
When Lockout Mode is entered, the ignition control
will remove power to the gas valve, the igniter will
turn off, the Lockout/Reset Light will turn on, and the
Diagnostic LED will display the appropriate Error
Code.
Lockout Manual Reset
Lockout Mode is cleared by pressing an external reset
switch for three seconds. The ignition control will
clear all error codes and enter Standby Mode. During
Lockout Manual Reset, the Diagnostic LED on the
ignition control flashes red and orange, and the Reset
Light remains on until the ignition control is reset.
After the Reset Light turns off, stop pressing the
switch. Holding the reset for three seconds after
lockout has been cleared will cause a fault and result in
entering Lockout Mode again.
The following system tests are performed during
normal operation. System tests are performed at a
minimum of every 24 hours.
Low Voltage Detection
If the voltage between terminals TH and GND on the
control is below 18.75VAC +/- 0.75VAC for more than
3 seconds the ignition control will turn off the gas
valve and will not attempt to spark. The Diagnostic
LED will display Error Code 5. The ignition control
will not enter Lockout Mode if a low voltage condition
is detected, but will enter Standby Mode and wait for
the low voltage condition to be cleared.
If the voltage between terminals TH and GND on the
control rises above 19.75VAC +/- 0.1VAC for at least 3
seconds, the ignition control will then enter Start Up
Mode.
Low Voltage Detection test is disabled during Run
Mode.
Gas Valve
The ignition control verifies that the gas valve is
connected. Failure of this test results in the ignition
control entering Lockout Mode with the Diagnostic
LED displaying Error Code 2.
Flame Probe Tests
Unexpected Presence of Flame
The Unexpected Presence of Flame test is performed
when no flame is expected. Failure of this test results
in the ignition control entering Lockout Mode with the
Diagnostic LED displaying Error Code 3.
Flame Monitoring
During the Flame Monitoring test, the flame is
checked to ensure the gas is being burned when the gas
valve is on. Failure of this test will result in the
ignition control entering Lockout Mode with the
Diagnostic LED displaying Error Code 3.
Diagnostic LED (DGN LED)/ Error Codes
The Diagnostic LED or DGN LED is located by the
power connector on the ignition control. Refer to
Figure 12. The Diagnostic LED will indicate the status
of the ignition control. Refer to Table 1.
LED ColorDescription
Orange-YellowInitialization
GreenStandby / Normal Operation
RedFault Indication Code
Table 1
The Diagnostic LED will flash error codes one half
second on and one half second off. Error codes are
separated by a one second pause before the code is
repeated.
Error
Code
1
2
3
4
5
6
1Diagnostic (DGN) LED
Red Ignition Control Internal Failure
2 Red FlashesGas Valve Not Connected
3 Red FlashesIgnition/Flame Sense Failure
4 Red FlashesReset Switch is Shorted
Slow Red and Green FlashesLow Voltage Detection
Fast Red and Orange FlashesIgnition Control is in Reset Delay
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
Daily
1. Inspect the area surrounding tumblers, remove all
combustible materials, including lint, before
operating the machines.
2. Check cylinder for foreign objects to avoid
damage to clothing and equipment.
3. Clean lint from lint compartment and screen to
maintain proper airflow and avoid overheating.
WARNING
To reduce the risk of serious injury, do not
open the lint panel while the tumbler is in
operation. Before cleaning the lint screen,
open tumbler door and allow cylinder to
completely stop.
a. Open the lint panel.
b. Remove all accumulated lint in the lint
compartment area. Lightly brush any lint that
may be left on the lint screen. Lint left in the
lint compartment is drawn back onto the lint
screen and will restrict airflow.
c. Be sure the lint screen is not torn. If it is,
replace immediately. A torn lint screen allows
lint to pass from the tumbler to the ductwork
system and may restrict airflow.
d. The lint screen is designed to completely
cover the entire opening in the lint screen
panel. Be sure that it does so. Excessive gaps
between the lint screen and the lint screen
panel allow lint to pass into the ductwork
system and may restrict airflow.
e. Carefully wipe any accumulated lint off of the
cabinet high limit thermostat and thermistor.
Failure to do so will allow a buildup of lint in
this area to act as an insulator, causing the
tumbler to overheat. Refer to Figure 13.
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
Monthly
1. Remove lint and debris from inside exhaust duct
to maintain proper airflow and avoid overheating.
a. Remove external duct and duct access covers,
if present.
b. Clean inside of duct with a vacuum.
c. Clean dampers and make sure they operate
freely.
d. Replace duct and all access covers before
returning tumbler to operation.
2. Ensure even lint distribution over lint screen,
replace if distribution of lint is uneven to
maintain proper airflow and avoid overheating.
3. Carefully wipe any accumulated lint off the
cabinet high limit thermostat and thermistor,
including perforated cover. Lint buildup will act
as an insulator, causing machine to overheat.
4. Clean lint and debris buildup from blower to
maintain proper airflow, to avoid overheating and
prevent possible vibration.
Bi-Annually
1. Check mounting hardware for any loose nuts,
bolts or screws.
2. Check gas connections for leakage.
3. Check for loose electrical connections.
4. Check steam connections for looseness and
leakage.
5. Remove all front panels and vacuum, including
coin drop mechanisms.
6. Check cylinder and front panel seals.
7. Inspect cabinet and inner panels for any damage,
replace or repair as needed.
Annually
1. Remove cylinder. Use a vacuum to clean lint
from area around rear seal and idler assembly.
Check seal and idler assembly for wear.
2. Remove burner tubes and clean using water and a
brush.
Quarterly
1. Use a vacuum to clean air vents on drive motors.
2. Use a vacuum to clean lint from rear limit
thermostat cover.
3. Check and clean steam coils, if applicable.
4. Check flow of combustion and ventilation air.
5. Check belt tension and condition. Replace worn
or cracked belts.
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
Daily Maintenance
Inspect the area surrounding tumblers,
remove all combustible materials,
including lint, before operating the
machine.
Check cylinder for foreign objects to
avoid damage to clothing and
equipment.
Maintenance
W002
Clean lint from lint compartment and
screen to maintain proper airflow and
avoid overheating.
Monthly Maintenance
Remove lint and debris from inside
exhaust duct to maintain proper airflow
and avoid overheating.
Ensure even lint distribution over lint
screen, replace if distribution of lint is
uneven to maintain proper airflow and
avoid overheating.
Carefully wipe any accumulated lint
off the cabinet high limit thermostat
and thermistor, including perforated
cover. Lint buildup will act as an
insulator, causing machine to overheat.
Clean lint and debris buildup from
blower to maintain proper airflow, to
avoid overheating and prevent possible
vibration.
Insert correct coin(s) or valid card if applicable.
Close the loading door tightly.
Close lint panel tightly.
Press the START pad/button.
Be sure power cord is plugged all the way into the electrical outlet.
Check the main fuse and circuit breaker.
Check fuses located in the machine.
Insufficient airflow.
Gas shut-off valve in OFF position.
Are controls properly set?
Broken drive belt. Call the service person.
••
••
••
Tumbler is in Cool Down Mode.
Lint screen clogged. Clean lint screen.
Exhaust duct to outside is blocked. Clean out.
Customer Service
If literature or replacement parts are required, contact
the source from which the machine was purchased or
contact Alliance Laundry Systems at (920) 748-3950
for the name and address of the nearest authorized
parts distributor.