ALLERSEARCH - THE AUSTRALIAN LEADER IN HOME NEBULISER SYSTEMS
INSTRUCTIONS
NOMAD® NexGen
Travel nebuliser system
Congratulations on your purchase of the Allersearch NOMAD® NexGen nebuliser pump.
Our goal is to satisfy customers requirement by offering cutting-edge systems for treating of asthma.
Carefully read these instructions and keep them in a safe place for future reference.
Use the unit only as described in this instruction manual.
COMPONENT LIST:
1. Aerosol therapy unit
1a. On-Off Switch
1b. Air inlet filter
1c. Air outlet port
1d. Nebuliser bowl holder
1e. Power supply female connector
1f. Battery contact cover
2. Universal power supply unit
(multi-voltage)
3. Car lighter cable (12V DC)
4. Optional attachable battery
(purchased separately)
4a. LED
4b. Charging connection
4c. Battery locking tabs
7c.
Product Code No. AE 650-043
5. Air tube
6. Connector for air tube-jet nebuliser
bowl connection
7. Jet nebuliser bowl (see also page 5)
7a. Bottom section
7b. Centre jet
7c. Top section
8. Mouthpiece
9. Adult face mask
10. Child face mask
11. Carrying bag
12. Spares kit
11.
7b.
4c.
4.
4b.
7a.
6.
5.
8.
12.
1.
1d.
7.
2.
4a.
6.
1f.
1c.
9.
10.
1a.
1e.
1b.
3.
5.
1
TABLE OF CONTENTS
1. MAIN SPECIFICATIONS page 2
2. IMPORTANT SAFEGUARDS page 2
3. COMPRESSOR OPERATING
INSTRUCTIONS page 3-4
3.1 Mains operation page 3
3.2 Operation with cigarette-lighter
socket page 3
3.3 Fitting the battery (OPTIONAL) page 3
3.4 Operation with battery (OPTIONAL) page 4
3.5 Battery recharge (OPTIONAL) page 4
4. NEBULISER OPERATING
INSTRUCTIONS page 5-6
4.1 Jet Nebuliser Bowl page 5
4.2 Instructions for aerosol therapy page 6
4.3 Cleaning and disinfection page 6
5. AIR FILTER page 7
6. TROUBLESHOOTING page 7
7. SPARE PARTS page 7
8. TECHNICAL SPECIFICATIONS page 8-9
1. MAIN SPECIFICATIONS
The NOMAD® NexGen has been designed and developed as a handy, lightweight and portable nebuliser
therapy system. Its main feature is practicality in use, especially for travellers and those who require nebuliser
therapy away from home and frequently. The NOMAD
the car lighter socket in cars, caravans, boats or from its own rechargeable battery (battery purchased as
a separate item).
The NOMAD
features a high nebuliser output performance, optimal particle size to ensure deep penetration into the lungs
and a non-spill feature that ensures no loss of medication if the nebuliser is accidentally dropped.
®
NexGen nebuliser system is complemented by a new-generation jet nebuliser bowl which
®
NexGen can be operated from mains voltage, through
2. IMPORTANT SAFEGUARDS
This is a medical device for home use and may only be used with medication prescribed or
recommended by a doctor.
Before using the unit for the first time, and periodically throughout its life, check the power supply cord for
any damage; if damage is apparent do not use. Take the unit immediately to an authorised service centre
or your dealer.
• Children and disabled persons should always use the unit under strict supervision of an adult who has
read this manual.
• Some components are small enough that children could swallow them; keep the unit out of reach of
children.
• The unit must not be used in the presence of inflammable gases such as oxygen nitrous oxide or anesthetic
substances.
• The power supply unit provided with the NOMAD
adapters for the specific country where it is to be used. Ask for information at the nearest authorized
service centre or your dealer.
Do not handle the plug of the power supply unit with wet hands and do not use the unit in wet
environments (for example while in the bath or shower). Never immerse the unit in water; should
this accidentally occur, unplug it immediately. Do not touch the unit until the plug has been removed from
the power socket. Take the unit immediately to an authorized service centre or your dealer.
• The case of the nebuliser therapy unit, power supply and battery are not protected against the ingress of
liquids. Never wash the unit under running water or by soaking. Keep away from sprays of water or other
liquids.
• Do not expose the Battery version unit to cold temperatures.
• Do not place the aerosol therapy unit, battery and power supply unit near sources of heat, in direct sunlight
or in excessively warm environments.
• Do not obstruct or place objects in the air inlet or front of air filter.
• Repairs should be carried out by authorised personnel only. Unauthorised repairs will invalidate the
warranty and may represent a hazard to the user.
• The Manufacturer, the Retailer and the Importer are responsible for safety, reliability and performance
only if: a) the unit is used following the instructions for use; b) the electrical system of the premises where
the unit is used is in conformity with current laws.
®
NexGen can be used worldwide by using suitable
2
3. COMPRESSOR OPERATING INSTRUCTIONS
2.
1e.
A
3.
3.1 MAINS OPERATION
For home use, plug the unit into an electrical socket via
the power supply unit provided (2.) as shown in figure
A.
If using this unit overseas please ensure that an appropriate
adaptor for the country of visit is purchased prior to
departure.
The unit can be operated with the battery fitted; however,
this does not charge the battery. For Battery Charging
Instructions see section 3.5
3.2 CAR LIGHTER SOCKET
For use in cars, caravans and boats, connect the unit to
the lighter socket (12V DC) (3.) with 12V DC lighter cable
(fig. B).
The unit can be operated with the battery fitted; however,
this does not charge the battery. For Battery Charging
Instructions see section 3.5
B
1e.
Sections C-H are only applicable when you purchase the battery as a separate item
3.3 FITTING THE BATTERY
• Before fitting the battery, remove the battery contact
cover located at rear of the unit (fig. C).
C
• Attach the battery correctly by using the locating spigot
and ensuring that the locking tabs are in place (fig. D).
D
3